Repair Maintenance Of Electrical Installation And Fans And Pump Sets Including Compound Lights At Delhi Archive Building , Qutub Institutional Area , New Delhi During The Year 2019-20 ( Sh Minor Repair And Replacement Of Ei And Fans ), Delhi Archive-Delhi

Public Works Department-PWD has published Repair Maintenance Of Electrical Installation And Fans And Pump Sets Including Compound Lights At Delhi Archive Building , Qutub Institutional Area , New Delhi During The Year 2019-20 ( Sh Minor Repair And Replacement Of Ei And Fans ). Submission Date for this Tender is 13-07-2020. Electrical Maintenance Tenders in Delhi Archive Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

24805538
Repair Maintenance Of Electrical Installation And Fans And Pump Sets Including Compound Lights At Delhi Archive Building , Qutub Institutional Area , New Delhi During The Year 2019-20 ( Sh Minor Repair And Replacement Of Ei And Fans )
Open Tender
Indian
Delhi
Delhi Archive
13-07-2020

Tender Details

repair maintenance of Electrical installation And Fans And Pump Sets Including Compound Lights At Delhi Archive Building , Qutub Institutional Area , New Delhi During The Year 2019-20 ( Sh Minor Repair And Replacement Of Ei And Fans )

Key Value

Document Fees
Refer document
EMD
INR 3085.0 /-
Tender Value
INR 1.54 Lakhs /-

BOQ Items

Name of Work: RMO EI & Fans and Pump Sets i/c Compound lights at Delhi Archive Building, Qutub Institutional Area, New Delhi during the year 2019-20 (SH- Minor repair and replacement of EI & Fans )
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. BI01010001010000000000000515BI0100001112
2 1.01 (a) Group C BI01010001010000000000000515BI0100001113 40 Pts.
3 2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. BI01010001010000000000000515BI0100001112
4 2.01 (a) Group C BI01010001010000000000000515BI0100001113 20 Pts.
5 3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel / PVC conduit as required. BI01010001010000000000000515BI0100001112
6 3.01 a) 3 X 1.5 sq.mm BI01010001010000000000000515BI0100001113 90 Mts
7 3.02 b) 6 X 1.5 sq.mm BI01010001010000000000000515BI0100001113 30 Mts
8 3.03 c) 3 X 4 sq.mm BI01010001010000000000000515BI0100001113 60 Mts
9 4 Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
10 4.01 a) Single Pole BI01010001010000000000000515BI0100001113 40 Nos
11 4.02 b) Single Pole and neutral BI01010001010000000000000515BI0100001113 10 Nos.
12 5 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required BI01010001010000000000000515BI0100001112 10 Nos.
13 6 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required BI01010001010000000000000515BI0100001112
14 6.01 a) 4 Module BI01010001010000000000000515BI0100001113 10 Nos
15 6.02 b) 6 Module BI01010001010000000000000515BI0100001113 5 Nos.
16 6.03 c) 12 Module BI01010001010000000000000515BI0100001113 5 Nos.
17 7 Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required BI01010001010000000000000515BI0100001112
18 7.01 a) 5/6 amp Switch BI01010001010000000000000515BI0100001113 100 Nos
19 7.02 b) 5/6 amp socket BI01010001010000000000000515BI0100001113 50 Nos
20 7.03 c) 15/16 amp switch BI01010001010000000000000515BI0100001113 70 Nos
21 7.04 d) 6 pin 15/16 amp socket BI01010001010000000000000515BI0100001113 70 Nos
22 8 Supplying and fixing suitable GI box with modular plate and cover in front on surface or in recess i/c providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve i/c connection, painting etc as reqd BI01010001010000000000000515BI0100001112 5 Nos.
23 9 Supplying, installation, testing and commissioning of 900 rpm 300mm sweep exhaust fan complete with louvers/ shutters in the existing opening i/c making the hole to suit the size of the above fan making good the damage & connections etc. as reqd. (Orient Model No 300mm (12") Industrial heavy duty/ Havells Model No Turbo Force SP/ Crompton Model No EXHD300-6-1) BI01010001010000000000000515BI0100001112 5 Nos.
24 10 Supplying, installation, testing & Commissioning of Surface/Wall Mounted 1 X 20W LED Tube With 4 feet MS Batten Fitting, LED Tube should have extruded aluminium housing for efficient heat dissipation. Total system Lumen of 18W Led should be 1700 or above in Cool day Light(5700K to 6500K), Power factor>0.95, CRI>80. Complete with Mounting Brackets & accessories as required with connections i/c credit of old dismantle material etc. complete as required. (Make Havells No LUMILINEPLUSBS20WLED865SPCSS / Crompton Greaves Model No LTT8-20 / Polycab INTEM50 DLX LED Batten 4 FEET/ Halonix HLB-08-20-CW-AL) BI01010001010000000000000515BI0100001112 30 Nos.
25 11 Supplying, installation, testing and commissioning of prewired 100 Watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminum extrusion with minimum luminaries of 100 per watt suitable for cool day whit light having minimum CCT 5700K, powerfactor >0.90, CRI>70%, driver efficiency >85 C, surge protection line to 4W-5KV & line to ground -10KV IP rating =IP66, thermal & impact resistance >1K-06, working life time >50000 hours, (including dismantling the old fitting if any) complete with all accessories etc. directly on ceiling / wall pole inclduing connection with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing i/c less credit of old dismantle material as and where basis etc. as required. (Make Havells Model No JETAIRISFLS100WLED757ASYMLTUL / Crompton Greaves Model No LFLN-100CDL/60 / Polycab Model No PCGLFT10210057/ Halonix Model No HLFLD-ML17-100-CW/Bajaj Model No BJFL100WLED1) BI01010001010000000000000515BI0100001112 3 Nos.
26 12 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required BI01010001010000000000000515BI0100001112 50 Nos.
27 13 Supplying and fixing brass batten/ angle holder including connections etc. as required. BI01010001010000000000000515BI0100001112 50 Nos.
28 14 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.\na) 63 A\n BI01010001010000000000000515BI0100001112 10 Nos.