Providing Of Servo Control Voltage Stabilizer Along With 30 Kva Ups , Prov Of Package And Ductable Acs And Connected Infrastructure For Dental Surgery Rooms And Provn Of Package Air Conditioner Along With Heating Ahu For Ortho Wards At Base Hospital Und, GE E/M BASE HOSPTIAL DELHI CANTT-Delhi

Military Engineer Services-MES has published Providing Of Servo Control Voltage Stabilizer Along With 30 Kva Ups , Prov Of Package And Ductable Acs And Connected Infrastructure For Dental Surgery Rooms And Provn Of Package Air Conditioner Along With Heating Ahu For Ortho Wards At Base Hospital Und. Submission Date for this Tender is 25-07-2020. UPS Tenders in GE E/M BASE HOSPTIAL DELHI CANTT Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

24793931
Corrigendum : Providing Of Servo Control Voltage Stabilizer Along With 30 Kva Ups , Prov Of Package And Ductable Acs And Connected Infrastructure For Dental Surgery Rooms And Provn Of Package Air Conditioner Along With Heating Ahu For Ortho Wards At Base Hospital Und
Open Tender
Indian
Delhi
GE E/M BASE HOSPTIAL DELHI CANTT
25-07-2020

Tender Details

Providing Of Servo Control Voltage Stabilizer Along With 30 Kva Ups , Prov Of Package And Ductable Acs And Connected Infrastructure For Dental Surgery Rooms And Provn Of Package Air Conditioner Along With Heating Ahu For Ortho Wards At Base Hospital Under

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Jul-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-07-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 67600.0 /-
Tender Value
INR 43.80 Lakhs /-

BOQ Items

Name of Work: Provn of Servo Control Voltage Stabilizer along with 30 KVA UPS, Prov of Package and Ductable ACs and connected infrastructure for Dental Surgery rooms and Provn of Package Air Conditioner along with Heating AHU for Ortho Wards at Base Hospital under GE E/M Base Hospital Delhi Cantt-10
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for point wiring, on surface, in casing capping complete using 1.5 Sqmm PVC insulated FRLS unsheathed, multi-stranded copper conductor cable, 1100 Volts grade, ISI marked, with PVC fittings such as bend, tee, junction boxes, elbows etc including pressed steel terminal sunken boxes of thickness 1.2mm, covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with Brass screws and unsheathed copper conductor stranded cable earth continuity wire connected to DBs/ Sunken boxes/ fittings of size 1.5 Sqmm Cross sectional area complete all as specified and directed. 25 Per Point
2 2 All as per item No. 1 here in before but point wiring using copper cable multi stranded 2.5 Sqmm size for 6 Amp/ 16 Amps multipurpose socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed. 45 Each
3 3 All as per item No. 1 here in before but point wiring using copper cable multi stranded 4.00 Sqmm size for AC point wiring on independent board with 4.0 Sqmm size earth conductor complete all as specified and directed. 45 Each
4 4 S&F Switch socket combination white polycarbonate body, 6A / 16A- 230 V, Multipurpose, including connecting complete all as specified and directed. 90 Each
5 5 S&F Switch socket combination white polycarbonate body, 6A- 230 V, 2/3 pin combined, including connecting complete all as specified and directed. 25 Each
6 6 M & L Sub main wiring using two run of single core PVC insulated FRLS cable 4.00 Sqmm copper conductor multi stranded and 4.00 Sqmm copper conductor insulated cable using as earth wire, drawing in to and including 25 mm dia, medium grade PVC conduit with boxes (junction/terminal) all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with PVC saddles complete all as specified and directed. \nNote:- Two runs of 4.00 Sqmm copper FRLS cable & one run of 4.00 Sqmm copper earth wire in and including 25mm dia PVC conduit, medium grade shall be measured as one unit. 45 Per RM
7 7 M & L Sub main wiring using two run of single core PVC insulated FRLS cable 6.00 Sqmm copper conductor multi stranded and 6.00 Sqmm copper conductor insulated cable using as earth wire, drawing in to and including 25 mm dia, medium grade PVC conduit with boxes (junction/terminal) all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with PVC saddles complete all as specified and directed. \nNote:- Two runs of 6.00 Sqmm copper FRLS cable & one run of 6.00 Sqmm copper earth wire in and including 25mm dia PVC conduit, medium grade shall be measured as one unit. 45 Per RM
8 8 M & L Sub main wiring using four run of single core PVC insulated FRLS cable 10.00 Sqmm copper conductor multi stranded and 10.00 Sqmm copper conductor insulated cable using as earth wire, drawing in to and including 32 mm dia, medium grade PVC conduit with boxes (junction/terminal) all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with PVC saddles complete all as specified and directed. \nNote:- Four runs of 10.00 Sqmm copper FRLS cable & one run of 10.00 Sqmm copper earth wire in and including 32 mm dia PVC conduit, medium grade shall be measured as one unit. 45 Per RM
9 9 S & F distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCCB DB, TPN 8 way with 250 Amps rated copper bus bar, 415 Volts with in built MCCB 125 Amps, 10 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and as directed. Make : Legrand Model: 5077 47 or equivalent model of Siemens/ Schneider (Acti-9)/HPL. 8 Each
10 10 S & F distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCCB DB, TPN 4 way with 250 Amps rated copper bus bar, 415 Volts with in built MCCB 125 Amps, 10 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and as directed. Make : Legrand Model: 5077 45 or equivalent model of Siemens/ Schneider (Acti-9)/HPL. 2 Each
11 11 S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 4 way with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 10 or equivalent model of Siemens/ Schneider (Multi-9)/HPL. 29 Each
12 12 S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 8 way with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 11 or equivalent model of Siemens/ Schneider (Multi-9)/HPL. 2 Each
13 13 S &F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 12 way with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 12 or equivalent model of Siemens/ Schneider (Multi-9)/HPL. 1 Each
14 14 S & F distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCCB DB, TPN, 12 way with 250 Amps rated copper bus bar, 415 Volts with in built MCCB 125 Amps, 10 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 5077 48 or equivalent model of Siemens/ Schneider (Acti-9)/HPL. 1 Each
15 15 S & F MCB SP 240 Volts, 6 Amps complete all as specified and directed.\n 45 Each
16 16 S & F MCB SP 240 Volts, 16 to 63 Amps complete all as specified and directed.\n 25 Each
17 17 S & F MCB SPN, 240 Volts, 32 to 63 Amps complete all as specified and directed. 20 Each
18 18 S & F MCB TPN 63 Amp complete all as specified and directed.\n 43 Each
19 19 S & F MCB TPN 100 Amp complete all as specified and directed.\n 4 Each
20 20 M&L Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate up to main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed. 10 Each Job
21 21 M&L Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 32X6 mm GI earth strip electrode welded and revetted to earth plate up to a distance of 7.5 mtr long, GI earth strip encased in and including 40mm bore GI light grade pipe, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed. 8 Each
22 22 Supplying, installation, testing and commissioning 150 KVA Servo controlled Voltage Stabilizer in sheet steel ventilated natural oil cooled construction (complete with first filling of transformer oil) having construction in such a manner that all the 3 units of single phase line voltage stabilizers connected in star. The set shall cater for unbalanced load and unbalance supply provided the input voltage between any phase and neutral and output current in any phase are with in limits. Detailed specifications are as specified below complete all as specified and as directed. 1 Each
23 22.01 I/P VOLTAGE : 300V-480V 3 PHASE UNBALANCE \nI/P FREQUENCY : 47-53 HZ \nO/P VOLTAGE : 415V ± 1%, 3PHASE,50 HZ O/P SHOULD BE STAR CONNECTED AS PER IS 9815 \nO/P ADJUSTMENT : ± 5% OF RATED O/P \nO/P VOLTAGE ACCURACY : BETTER THAN + 1% \nRATING : 150 KVA AT UPF \nLOAD : UNBALANCE \nSPEED OF CORRECTION : 8V / SEC (PH-PH) \nEFFICIENCY : BETTER THAN 96% \nWAVEFORM DISTORTION : NIL \nEFFECT OF LOAD : NIL \nENVIRONMENT : INDOOR TROPICAL USE \nAMBIENT : 0-50 DEG. C.\nMATERIAL FOR WINDINGS : COPPER
24 22.02 The Servo controlled voltage stabilizer shall have following additional features:-\nFull solid state control circuit, No effect ON load Power factor, Auto/manual operation facility, Tripping indication : High/Low I/P voltage tripping with overload /short circuit tripping facility, By pass arrangement with changes over switch, Audio visual alarm circuit, Indicator for I/P/O/P Volt O/P Amp frequency meter Digital/Analog.
25 23 Supply, laying and connecting XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables, heavy duty, 1100 Volts grade with standard aluminium conductor of the following size complete all as specified and directed:-
26 23.01 185 Sqmm 3 ½ core 10 RM
27 23.02 95 Sqmm 3 ½ core 55 RM
28 23.03 35 Sqmm 3 ½ core 50 RM
29 23.04 25 Sqmm 3 ½ core 5 RM
30 23.05 16 Sqmm , 4 core 90 RM
31 23.06 10 Sqmm , 4 core 55 RM
32 23.07 16 Sqmm , 2 core 37 RM
33 24 Supply, installation, testing and commissioning of 30 KVA on line UPS with inbuilt isolation transformer and connected Battery Rack and link & Accessories including battery bank suitable for 15 Minuts back up with 2 Set of 17 Nos, 12V/42AH Batteries with and including connected accessories as per OEM standards complete all as specified and as directed. 1 Each Set
34 25 Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and as directed. 10 Cum
35 26 Returning filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick complete all as specified and as directed. 5 Cum
36 27 Removing excavated Soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.. 5 Cum
37 28 M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer complete all as specified and as directed. \nNote: For measurement purpose punned thickness of sand shall only be considered. 3 Cum
38 29 Supply and Laying burn brick, sub class 'B' size 225 mm X 113 mm X 75 mm as in protection to cable complete all as specified and directed. 300 Each
39 30 Supply, fixing and connecting 20 Amp Industrial type Plug and socket suitable for OT equipment connection suitable for Flush Mounting and surface mounting with Neutral Links with provision for mounting modular devices with inbuilt MCB DP 16 Amp complete all as specified and as directed. Make :- Legrand, Model No 5078 60 or equivalent Model of Siemens/ ABB/ Schneider 2 Each
40 31 Supply, fixing and connecting 32 Amp Industrial type Plug and socket suitable for OT equipment connection suitable for Flush Mounting and surface mounting with Neutral Links with provision for mounting modular devices with inbuilt MCB TP 32 Amp complete all as specified and as directed. Make :- Legrand, Model No 5078 61 or equivalent Model of Siemens/ ABB/ Schneider 7 Each
41 32 Supply, fixing and connecting 32 Amp Industrial type Plug and socket suitable for OT equipment connection suitable for Flush Mounting and surface mounting with Neutral Links with provision for mounting modular devices with inbuilt MCB DP 32 Amp complete all as specified and as directed. Make :- Legrand, Model No 5078 63 or equivalent Model of Siemens/ ABB/ Schneider 2 Each
42 33 Supply, installation, commissioning and testing Air Cooled type, Package Type Air conditioners with Nominal cooling capacity 11 TR, Capacity 132000 Btu/Hr, with charged refrigerant Gas R410A/ 407C, 3 Phase, 415 V, 50 HZ made with Pure polyester powder coated GI steel, comprising of Scroll compressor equipped, copper refrigerant piping as per OEM recommendation up to 25 Mtr (set of two for suction and discharge for each compressor circuit from indoor to outdoor), Anti -corrosion condenser Fin coating for out door unit condenser unit with suitable size condenser coil, fan motor etc electrical interconnection between indoor and outdoor units as per OEM recommendation, with precharged refrigerant 407C/R - 410A , antivibration pads with following detailed specifications complete all as specified and as directed. Make :- Blue star Model No :- DPA 1322 R2 series or equivalent model of Carrier/ Hitachi/ Daikin/ O-GENERAL 4 Unit
43 33.01 The intelligent microprocessor controller of Air Conditioners shall be consisting of following :-\n(a) Seven segment LCD display \n(b) Touch - Key on/off switch\n(c) Auto restart after power failure\n(d) Single phasing/ Phase loss/ Phase reversal\n(e) Over voltage/ Under Voltage protection\n(f) Over load / Over current protection\n(g) Fault display\n(h) Time delay for compressor operation\n(j) Run time equalisation\n(k) Provision for fire alarm input
44 33.02 The Touch screen controller installed at indoor unit of Air Conditioners shall be consisting of following features :-\n(a) Compressor status indication\n(b) Room temperature display\n(c) Wide temperature range 19-32 °C\n(d) ON -OFF timer \n(e) Error Indication\n(f) Error Reset\n(g) High speed two way communication:-\n High speed two way communication (RS485) between indoor controller and outdoor unit.
45 34 Supply, installation, commissioning and testing Air Cooled type, Package Type Air conditioners with Nominal cooling capacity 16.5 to 17TR , Capacity 198000 Btu/Hr with charged refrigerant Gas R410A/ 407C, 3 Phase, 415 V, 50 HZ made with Pure polyester powder coated GI steel, comprising of Scroll compressor, copper refrigerant piping as per OEM recommendation up to 25 Mtr (set of two for suction and discharge for each compressor circuit from indoor to outdoor), Anti -corrosion condenser Fin coating for out door unit condenser unit with suitable size condenser coil, fan motor etc electrical interconnection between indoor and outdoor units as per OEM recommendation, with precharged refrigerant 407C/R - 410A , antivibration pads with following detailed specifications complete all as specified and as directed. Make :- Blue star Model No :- DPA 1983 R2 series or equivalent model of Carrier/ Hitachi/ Daikin/ O-GENERAL 4 Unit
46 34.01 The intelligent microprocessor controller of Air Conditioners shall be consisting of following\n(a) Seven segment LCD display \n(b) Touch - Key on/off switch\n(c) Auto restart after power failure\n(d) Single phasing/ Phase loss/ Phase reversal\n(e) Over voltage/ Under Voltage protection\n(f) Over load / Over current protection\n(g) Fault display\n(h) Time delay for compressor operation\n(j) Run time equalisation\n(k) Provision for fire alarm input
47 34.02 The Touch screen controller installed at indoor unit of Air Conditioners shall be with following features :-\n(a) Compressor status indication\n(b) Room temperature display\n(c) Wide temperature range 19-32 °C\n(d) ON -OFF timer \n(e) Error Indication\n(f) Error Reset\n(g) High speed two way communication:-\nHigh speed two way communication (RS485) between indoor controller and outdoor unit
48 35 Supply, installation, commissioning and testing Air Cooled type, Inverter type ductable Type Air conditioners with Nominal cooling capacity 5.0 TR, Capacity 60000 Btu/Hr with charged refrigerant R410A/ 407C, 3 Phase, 415 V, 50 HZ made with Pure polyester powder coated GI steel, comprising of Inverter compressor, copper refrigerant piping as per OEM recommendation up to 25 Mtr Appx (set of two for suction and discharge for each compressor circuit from indoor to outdoor), Anti -corrosion condenser Fin coating for out door unit condenser unit with suitable size condenser coil, fan motor etc electrical interconnection between indoor and outdoor units as per OEM recommendation, with precharged refrigerant 407C/R - 410A , antivibration pads with following detailed specifications complete all as specified and as directed. Make :- Blue star Model No :- DSAI 601R3A series or equivalent model of Carrier/ Hitachi/ Daikin/ O-GENERAL 2 Each
49 35.01 The intelligent microprocessor controller of Air Conditioners shall be consisting of following: -\n(a) Seven segment LCD display \n(b) Touch - Key on/off switch\n© Auto restart after power failure\n(d) Single phasing/ Phase loss/ Phase reversal\n(e) Over voltage/ Under Voltage protection\n(f) Over load / Over current protection\n(g) Fault display\n(h) Time delay for compressor operation\n(j) Run time equalisation\n(k) Provision for fire alarm input
50 35.02 The Touch screen controller installed at indoor unit of Air Conditioners shall be with following features :-\n(a) Compressor status indication\n(b) Room temperature display\n(c) Wide temperature range 19-32 °C\n(d) ON -OFF timer \n(e) Error Indication\n(f) Error Reset\n(g) High speed two way communication:-\nHigh speed two way communication (RS485) between indoor controller and outdoor unit.
51 36 Supply, installation, commissioning and testing Air Cooled type Inverter type ductable Type Air conditioners with Nominal cooling capacity 8.0 TR, Capacity 96000 Btu/Hr with charged refrigerant R410A/ 407C, 3 Phase, 415 V, 50 HZ made with Pure polyester powder coated GI steel, comprising of Inverter compressor, copper refrigerant piping as per OEM recommendation up to 25 Mtr Appx (set of two for suction and discharge for each compressor circuit from indoor to outdoor ), Anti -corrosion condenser Fin coating for out door unit condenser unit with suitable size condenser coil, fan motor etc electrical interconnection between indoor and outdoor units as per OEM recommendation, with precharged refrigerant 407C/R - 410A , antivibration pads with following detailed specifications complete all as specified and as directed. Make :- Blue star Model No :- DSAI 961R3A series or equivalent model of Carrier/ Hitachi/ Daikin/ O-GENERAL 1 Each
52 36.01 The intelligent microprocessor controller of Air Conditioners shall be consisting of following :-\n(a) Seven segment LCD display \n(b) Touch - Key on/off switch\n(c) Auto restart after power failure\n(d) Single phasing/ Phase loss/ Phase reversal\n(e) Over voltage/ Under Voltage protection\n(f) Over load / Over current protection\n(g) Fault display\n(h) Time delay for compressor operation\n(j) Run time equalisation\n(k) Provision for fire alarm input
53 36.02 The Touch screen controller installed at indoor unit of Air Conditioners shall be with following features :-\n(a) Compressor status indication\n(b) Room temperature display\n(c) Wide temperature range 19-32 °C\n(d) ON -OFF timer \n(e) Error Indication\n(f) Error Reset\n(g) High speed two way communication:-\nHigh speed two way communication (RS485) between indoor controller and outdoor unit.
54 37 OUT DOOR TYPE ALL WEATHER AIR HANDLING UNIT CFM & STATIC : 4400 CFM & 35mm static\nSupply, installation testing, commissioning of outdoor type ALL WEATHER AIR HANDLING UNIT with 4400 CFM & 35mm static, installed on anti vibration pads and supports as per OEM recommendation with inbuilt dampers including foundation with block masonry and PCC work complete all as recommended by OEM and Engg -in-charge complete up to 3 Ft height ( For supply, Return, Fresh Air and Exhaust Ducts) with following equipments and detailed specifications complete all as specified and as directed: - \n MAKE : ZECO / CITIZEN / LOYDDS\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n 3 Each
55 37.01 AHU CAPACITY – Air Handling Unit shall be capable to deliver 4400 CFM at 35mm Static Pressure.\nCASING – The housing / casing of Air Handling unit shall be of double skin construction. Casing frame work shall be of extruded aluminium section with thermal break barrier aluminium profiles. Thermal Break Double skin panel shall be made of outer skin 0.8mm pre coated GI sheet and inner skin 0.6mm plain stainless steel sheet, insulation in both skin shall be 45mm thick CFC free puff injected insulation of 40KG/ cubic meter density.\nPanel shall be screwed to the frame work with soft gasket to make air tight joint. Suitable doors with powder coated hinge shall be provided for access to maintenance. \nLow leakage of AL constructed volume control dampers shall be providing for Return Air / Fresh Air / Exhaust Air / Supply Air.\n
56 37.02 FAN – FC fan motor shall be provide with direct couple arrangement as per OEM recommendation. \nFan Dia :- 18x18-S1\nFan RPM :- 710\nFan outlet velocity :- 7.8 M/S\nShaft absorbing power :- 1.36\nMotor Rating :- 1.5 KW\nMotor Pole :- 4 pole\n
57 37.03 HEATER :- 6 kw
58 37.04 FILTER – Synthetic (non Woven type) \nEfficiency of pre -filters (EU-4) :- 90 % down to 10 micron\n
59 37.05 SAFTY :-Limit Switch – fan section all doors should be provided with fitment of limit switch and lamps. Fan section door should be providing with wire guard to protect any casual entry inside the AHU. Fan suction port should have diffusion plate.\n
60 37.06 AHU CONTROL PANEL :\nAHU control panels shall be with following specifications - \nMCB for AHU, MCB for Contractors for controlling temperature and heater bank, Temperature controller with sensors, Contactors etc all as recommended and specified by OEM. \n
61 38 Supply, assembly and erection of GI sheet of thickness as mentioned below with C & SS rectangular/square duct made out of 'L' shaped hollow profile, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc, complete with necessary angle iron work for supporting /hanging of duct with fastener/ grouting in wall with necessary cement work and making good complete all as specified and as directed :-
62 38.01 (a) 24 Gauge GI sheet 187 Sqm
63 38.02 (b) 22 Gauge GI sheet. 22 Sqm
64 39 S&F fire proof, double layered, canvass cloth connection for AHU outlet including inspection opening complete with flanges made our of 22 GSS Sheet on both side for connection to AHE and duct with nuts, bolts complete all as specified and as directed. 8 Each Job
65 40 Supply, installation, testing and commission of fire dampers complete with smoke detector/ thermister linkage etc and actuator as required for operation complete all as specified and as directed. 2.5 Sqm
66 41 Supply, installation, testing and balancing of square shape supply air diffusers with removable core and antismudge ring and volume control dampers powder coated extruded aluminium construction complete all as specified and as directed. 10.05 Sqm
67 42 Supply, installation, testing and balancing of square shape return air diffusers with removable core and antismudge ring and without control dampers with powder coated extruded aluminium construction complete all as specified and as directed. 10.5 Sqm
68 43 Supply, erection and fixing in position 25 mm thick nitrile duct insulation with Aluminium foil. The thermal insulation shall be 25 mm thick non-fibrous, fire retardant, closed cell, tri- dimensional chemically cross linked polyethylene foam, conforms to class O' for fire propagation and class 1 for surface spread of flame & factory laminated aluminium foil complete all as specified and as directed. 226 Sqm
69 44 Supply and fixing Acoustic treatment/ lining of area of AHU room with 22G, GI channels of 50x50 mm size fitted at 600x600mm girds. These girds shall be fitted with 50mm thick 32 kg/cum fibber glass insulation covered by fibber glass tissue and 24 G Al perforated sheet and as required. The joint should be minimum overlapping of 75mm with 30mmx 3mm aluminium strip covering. All corners shall be provided with 20x20x2mm aluminium angle with stainless steel counter sunk screws complete all as specified and as directed. 21 Sqm
70 45 Supply and fixing acoustic lining of supply air ducting complete with GI frame, tissue paper, 26 Gauge perforated AL Sheet 25mm thick of density 32 kg/cum fibre glass insulation. 37 Sqm
71 46 M&L for sub main wiring with 4 runs of 16 Sqmm single core, FRLS PVC insulated & unsheathed cable 1100 Volts grade, with multi stranded copper conductor drawing in to and including concealed conduit including PVC rigid conduit medium grade 40 mm dia as per IS with boxes (junction/terminal) all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories, pipe hook etc including all fixtures /fittings and one run of 16 Sqmm size FRLS PVC insulated copper conductor as earth wire complete all as specified and directed. (Note: Four runs of 16.00 Sqmm copper FRLS cable & one run of 16.00 Sqmm copper earth wire in and including 40mm dia PVC conduit, medium grade shall be measured as one unit) \n 164 RM
72 47 S&F angle iron, MS flat to support duct with angle iron, flats, nut bolt washers etc. with anchor fastener. Necessary welding work involved shall also deemed to be included in quoted rate include cutting fabrication welding of angle iron / MS Flat, repair to RCC wall, cost of anchor fastener etc complete all as specified and directed. 101 Kg
73 48 S&F motorized spring return actuator for device with control panel and temperature sensor complete all as specified and as directed. 2 Each
74 49 Supply, installation, testing & commissioning Outdoor type feeder pillar Box made out of 3.15 mm thick CRCA sheet, 415 Volt, 3 phase, 50 HZ supply, factory made with MS angle section 40 x40x 5mm frame, with front and back openable double door with provision of locking arrangement, dust & vermin proof, gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly spray painted inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel paint grey & Consisting of the following equipments complete all as specified and directed:- 1 Each
75 49.01 (i) MCCB, 4 pole , 35 KA, 200 Amps - 01 No. ( Incoming)
76 49.02 (ii) MCB, 4 pole, 10 KA, 63 Amps - 04 Nos.
77 49.03 (iii) Digital voltmeter of size 96 x96 mm (0-500v) with built in selector switch
78 49.04 (iv) Digital Ammeter of size 96 x96 mm (0-150A) with built in selector switch
79 49.05 (v) Indication Lamp 22.5 mm dia LED type 240 Volts AC to show three phase availability- 01 set
80 49.06 (vi) Solid aluminium bus bar 400 Amp for 3 phase, 100 Amp for neutral.
81 49.07 (vii) PCC and block Masonry work for grouting of panel complete all as specified and directed by Engr-in-Charge.
Disclaimer :