Replacement Of Lt Panel Board At 11 Block Kalkaji Bps ., EXECUTIVE ENGINEER (EM) WS SOUTH-I-Delhi

Delhi Jal Board-DJB has published Replacement Of Lt Panel Board At 11 Block Kalkaji Bps .. Submission Date for this Tender is 09-07-2020. Electrical Panel Tenders in EXECUTIVE ENGINEER (EM) WS SOUTH-I Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

24774809
Replacement Of Lt Panel Board At 11 Block Kalkaji Bps .
Open Tender
Indian
Delhi
EXECUTIVE ENGINEER (EM) WS SOUTH-I
09-07-2020

Tender Details

Replacement Of Lt Panel Board At 11 Block Kalkaji Bps . , lt distribution panel sheet steel enclosure made out of 2mm crca sheet totally enclosed , powder coated free standing , floor mounted type , dust& vermin proof , outward opening , lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide ip-54 protection . the each part of the fabricated panel will be strictly subjected to seven tank treatment . the various components , assemblies and sub equipments of the panel will be as per standard given in relevant is . the bus bar of the panel will be shaped out of high conductivity , electrolytic conductor and shall be liberal sized in aluminium . the control wiring of the panel will be done with pvc flexible copper wires of 1 . 5mm cross section . each wire will be terminating with a ferule crimped to the wire , size 1800mm x1600x375mm . having following components of approved make: l&t/siemens/epcos/ae/havells . , mccb 415v , tp 3phase high breaking capacity 50ka 50hz , 200ampwith spreader& handle . , mccb 415v , tp 3phase high breaking capacity 50ka 50hz , 100amp with spreader . , mcb single pole 6amp . , mcb triple pole 32amp , mcb triple pole 63amp , pvc insulated copper flexible cable single core 16sq . mm make: havells/finolex , power capacitors 415v unit of 10kvar make: epcos/l&t , over load relay 20-33 . , over load relay 6-10 amp range make: l&t/siemens , amp . meter digita . , volt meter digital . , motor protection relay . , power contactor 220v 3phase70amp . , power contactor 220v 3phase50amp . , power contactor 220v 3phase25amp . , star delta timer on delay . , indicating lights led type ryb& on/off . , current transformer200/5 , 100/5 , 30/5 make ae /advance , on load change over switch 200amp . open execution type . , fitting of the above components in panel enclosure with terminal blocks , channels , ferrules , thimble , support insulator on bus bar , required hard wares , control wiring in 1 . 5sq mm wire complete in all respect . , dismantling of old panel , structure , damaged components and installation of the panel at site by making foundation , termination of cable both incoming & out going side , mongeringof complete panel , including cable connection , . this includes cartage , loading& unloading etc . , testing & commissioning of the panel with relevant is as follow: - check equipments specification - continuity and earthing -mccb mechanism and alignment -meggaring of all equipments for phase to phase , neutral to body , neutral to earth and phase to earth . - all functional tests -checking for all tightness of nuts and bolts -alignments of doors etc . -interlocking tests

Key Value

Document Fees
INR 500 /-
EMD
INR 5100.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Replacement of LT Panel board at 11 Block Kalkaji BPS.
Sl. No. Item Description Item Code / Make Quantity Units
1 1.01 LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminium. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire, size 1800MM x1600x375MM. Having following components of approved make: L&T/Siemens/Epcos/AE/Havells. item1 1 Nos.
2 2 MCCB 415V, TP 3phase High breaking capacity 50KA 50Hz,200Amp  with spreader& Handle. item2 1 Nos.
3 2.99 MCCB 415V, TP 3phase High breaking capacity 50KA 50Hz,100Amp with spreader. item3 2 Nos.
4 3.98 MCB Single pole 6Amp. item4 6 Nos.
5 4.97 MCB Triple pole 32Amp item5 1 Nos.
6 5.96 MCB Triple pole 63Amp item6 1 Nos.
7 6.95 PVC insulated copper flexible cable single core 16 Sq.mm Make: Havells/Finolex item7 100 Mtr.
8 7.94 Power capacitors 415V unit of 10Kvar Make: Epcos/L&T item8 2 Nos.
9 8.93 Over load relay 20-33. item9 2 Nos.
10 9.92 Over load relay 6-10 Amp Range Make: L&T/Siemens item10 1 Nos.
11 10.91 Amp. Meter Digita. item11 4 Nos.
12 11.9 Volt Meter Digital. item12 1 Nos.
13 12.89 Motor protection Relay. item13 2 Nos.
14 13.88 Power contactor 220V 3phase70Amp. item14 4 Nos.
15 14.87 Power contactor 220V 3phase50Amp. item15 2 Nos.
16 15.86 Power contactor 220V 3phase25Amp. item16 1 Nos.
17 16.85 Star delta timer on delay. item17 2 Nos.
18 17.84 Indicating lights LED type RYB  & On/OFF. item18 8 Nos.
19 18.83 Current Transformer200/5,100/5,30/5 Make AE /Advance item19 9 Nos.
20 19.82 On load change over switch 200Amp. Open execution type. item20 1 Nos.
21 20.81 Fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hard wares, control wiring in 1.5sq mm wire complete in all respect. item21 1 Job.
22 21.8 Dismantling of old panel, structure, damaged components and Installation of the panel at site by making foundation ,termination of cable both incoming & out going side ,mongering  of complete panel , including cable connection,. This includes cartage, loading& unloading etc. item22 1 Job.
23 22.79 Testing & commissioning of the panel with relevant IS as follow:\n- Check equipments specification\n- Continuity and earthing\n-MCCB mechanism and alignment\n-Meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth.\n- All functional tests\n-Checking for all tightness of nuts and bolts\n-Alignments of doors etc.\n-interlocking tests\n item23 1 Job.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail