Cartage , Installation , Testing And Commissioning Of Ht Vcb Panel , Supply Installation Testing An Commissioning Of Metering Ct And Pt At Icmr , Ansari Nagar East , New Delhi ., ICMR, Ansari Nagar East, New Delhi-Delhi

New Delhi Municipal Council-NDMC has published Cartage , Installation , Testing And Commissioning Of Ht Vcb Panel , Supply Installation Testing An Commissioning Of Metering Ct And Pt At Icmr , Ansari Nagar East , New Delhi .. Submission Date for this Tender is 09-07-2020. Circuit Breakers Tenders in ICMR, Ansari Nagar East, New Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

24773523
Cartage , Installation , Testing And Commissioning Of Ht Vcb Panel , Supply Installation Testing An Commissioning Of Metering Ct And Pt At Icmr , Ansari Nagar East , New Delhi .
Open Tender
Indian
Delhi
ICMR, Ansari Nagar East, New Delhi
09-07-2020

Tender Details

Cartage , Installation , Testing And Commissioning Of Ht Vcb Panel , Supply Installation Testing An Commissioning Of Metering Ct And Pt At Icmr , Ansari Nagar East , New Delhi .

Key Value

Document Fees
Refer document
EMD
INR 8576.0 /-
Tender Value
INR 4.28 Lakhs /-

BOQ Items

Name of Work:Sanction of new electric connection of 915.63 KW after surrendering of 327.48KW at ICMR, Ansari Nagar East, New Delhi.SH: Cartage, Installation, Testing and commissioning of HT VCB panel, SITC of metering CT&PT at ICMR, Ansari Nagar East, New Delhi.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Cartage, Installation, testing and commissioning of HT Panels. \n(HT Panel shall be provided by NDMC)\n\n\n\n\n BI01010001010000000000000515BI0100001113 2 Nos.
2 2 Supply & fixing of adaptor box for coupling of HT VCB 11 KV panel with existing 11 KV panel by providing 14 SWG MS Sheet box powder coated, main connection bus bar made of copper size 50x10mm bus bar with insulated sleeve insulator with fabrication work and minor material such as nut, bolts, washer etc as req. at site.\n BI01010001010000000000000515BI0100001114 2 Nos.
3 3 SITC of 11 KV indoor epoxy resin casted CT single wound for protection/metering CT ratio suitable as per load class 0.5 p10 VA burden 15, short time current 18.4KA/1 sec insulation level 12/18/75KVP as per ISS 2705/1992 for 11 KV HT panel. (3 Nos. in one set) BI01010001010000000000000515BI0100001114 1 Set
4 4 Supply, testing & commissioning of metering PT & erection on panel complete as required 1000/110V ratio 100VA burden per phase with 0.5 accuracy with complete housing suitable for HT VCB panel.(3 Nos. in one set) BI01010001010000000000000515BI0100001114 1 Set
5 5 Providing & fixing 32x5mm cu strip on surface or in recess for connection etc as required.\n BI01010001010000000000000515BI0100001114 10 Mtrs