Procurement Of Solar Power Supply System , Supply Installation Testing & Commissioning Of Solar Powersystem With Battery Back-Up , Solar Panel System For Golaghat Terminal Lsolar Power Supply System -5 Kva , 415 V , Ac , 3 Ph , N , ( Solar Panels Have Redundancy Parallel Redundant 2 Nos X 100 % Rating & Charge Controller Have 2 Nos X 200% Ratings ) Along With Additional Battery Charger & Nickel Cadmium Battery Bank With Battery Rack ( Suitable For Solar Charging , As Per Specification And Datasheet ) . Battery Bank Suitable For Sufficient Backup Time At Full Load Shall Be Provided For Meeting Critical Loads That Cannot Withstand Even A Momentary Interruption In Voltage . Battery Banks - ( 2Nos . X 50% Ni-Cd Battery Bank - 10 Hours Battery Backup For 4 Kw Continious Load & 15 Minute Back-Up For 4 Kw Intermittent Load ) :Delivery Of Complete Solar Power System Shall Be At Golaghat Terminal , Agcl . Refer Sld -1009-Gg-El- Sld -4001 _0 . Solar Power System Shall Be Complete In All Respect . & Systems Functional Responsibility Shall Be In Vendors Scope . Construction Of Battery Room ( Building ) Including Complete Civil Work And Electrical Work As Per Dwg-1009-Cs -Arc-6003 Rev -C1 . Shall Be In Contractors Scope . , Solar Panel System For Uriumghat Terminal Solar Power Supply System -5 Kva , 415 V , Ac , 3 Ph , N , ( Solar Panels Have Redundancy Parallel Redundant 2 Nos X 100 % Rating & Charge Controller Have 2 Nos X 200% Ratings ) Along With Additional Battery Charger & Nickel Cadmium Battery Bank With Battery Rack ( Suitable For Solar Charging , As Per Specification And Datasheet ) . Battery Bank Suitable For Sufficient Backup Time At Full Load Shall Be Provided For Meeting Critical Loads That Cannot Withstand Even A Momentary Interruption In Voltage . Battery Banks - ( 2Nos . X 50% Ni-Cd Battery Bank - 10 Hours Battery Backup For 4 Kw Continious Load & 15 Minute Back-Up For 4 Kw Intermittent Load ) :Delivery Of Complete Solar Power System Shall Be At Urimghat Terminal , Agcl . Refer Sld -1009-Ur-El- Sld -4001 _0 . Solar Power System Shall Be Complete In All Respect . & Systems Functional Responsibility Shall Be In Vendors Scope . Construction Of Battery Room ( Building ) Including Complete Civil Work And Electrical Work As Per Dwg-1009-Cs -Arc-6003 Rev -C1 . Shall Be In Contractors Scope , Solar Panel System For Numaligarh Terminal Solar Power Supply System -5 Kva , 415 V , Ac , 3 Ph , N , ( Solar Panels Have Redundancy Parallel Redundant 2 Nos X 100 % Rating & Charge Controller Have 2 Nos X 200% Ratings ) Along With Additional Battery Charger & Nickel Cadmium Battery Bank With Battery Rack ( Suitable For Solar Charging , As Per Specification And Datasheet ) . Battery Bank Suitable For Sufficient Backup Time At Full Load Shall Be Provided For Meeting Critical Loads That Cannot Withstand Even A Momentary Interruption In Voltage . Battery Banks - ( 2Nos . X 50% Ni-Cd Battery Bank -10 Hours Battery Backup For 4 Kw Continious Load & 15 Minute Back-Up For 4 Kw Intermittent Load ) :Delivery Of Complete Solar Power System Shall Be At Naumalighar Terminal , Agcl . Refer Sld -1009-Nu-El- Sld -4001 _0 . Solar Power System Shall Be Complete In All Respect . & Systems Functional Responsibility Shall Be In Vendors Scope . Construction Of Battery Room ( Building ) Including Complete Civil Work And Electrical Work As Per Dwg-1009-Cs -Arc-6003 Rev -C1 . Shall Be In Contractors Scope , Solar Panel System For Halmiramukh Terminal Solar Power Supply System -5 Kva , 415 V , Ac , 3 Ph , N , ( Solar Panels Have Redundancy Parallel Redundant 2 Nos X 100 % Rating & Charge Controller Have 2 Nos X 200% Ratings ) Along With Additional Battery Charger & Nickel Cadmium Battery Bank With Battery Rack ( Suitable For Solar Charging , As Per Specification And Datasheet ) . Battery Bank Suitable For Sufficient Backup Time At Full Load Shall Be Provided For Meeting Critical Loads That Cannot Withstand Even A Momentary Interruption In Voltage . Battery Banks - ( 2Nos . X 50% Ni-Cd Battery Bank - 10 Hours Battery Backup For 4 Kw Continious Load & 15 Minute Back-Up For 3 Kw Intermittent Load ) :Delivery Of Complete Solar Power System Shall Be At Halmiramukh Terminal , Agcl . Refer Sld -1009-Ha-El- Sld -4001 _0 . Solar Power System Shall Be Complete In All Respect . & Systems Functional Responsibility Shall Be In Vendors Scope . Construction Of Battery Room ( Building ) Including Complete Civil Work And Electrical Work As Per Dwg-1009-Cs -Arc-6003 Rev -C1 . Shall Be In Contractors Scope , Solar Panel System For Thoramukh Terminal Solar Power Supply System -5 Kva , 415 V , Ac , 3 Ph , N , ( Solar Panels Have Redundancy Parallel Redundant 2 Nos X 100 % Rating & Charge Controller Have 2 Nos X 200% Ratings ) Along With Additional Battery Charger & Nickel Cadmium Battery Bank With Battery Rack ( Suitable For Solar Charging , As Per Specification And Datasheet ) . Battery Bank Suitable For Sufficient Backup Time At Full Load Shall Be Provided For Meeting Critical Loads That Cannot Withstand Even A Momentary Interruption In Voltage . Battery Banks - ( 2Nos . X 50% Ni-Cd Battery Bank -10 Hours Battery Backup For 4 Kw Continious Load & 15 Minute Back-Up For 3 Kw Intermittent Load ) :Delivery Of Complete Solar Power System Shall Be At Thoramukh Terminal , Agcl . Refer Sld -1009-Th-El- Sld -4001 _0 . Solar Power System Shall Be Complete In All Respect . & Systems Functional Responsibility Shall Be In Vendors Scope . Construction Of Battery Room ( Building ) Including Complete Civil Work And Electrical Work As Per Dwg-1009-Cs -Arc-6003 Rev -C1 . Shall Be In Contractors Scope , Solar Panel System For Sectionalizing Valve Station ( Between Thoramukh And Numaligarh ) Solar Power Supply System -3 Kva , 415 V , Ac , 3 Ph , N , ( Solar Panels Have Redundancy- Parallel Redundant 2 Nos X 100 % Rating & Charge Controller Have 2 Nos X 200% Ratings ) Along With Additional Battery Charger & Nickel Cadmium Battery Bank With Battery Rack ( Suitable For Solar Charging , As Per Specification And Datasheet ) . Battery Bank Suitable For Sufficient Backup Time At Full Load Shall Be Provided For Meeting Critical Loads That Cannot Withstand Even A Momentary Interruption In Voltage . Battery Banks - ( 2Nos . X 50% Ni-Cd Battery Bank For 10 Hours Battery Backup For 3 Kw Continious Load & 15 Minute Back-Up For 2 Kw Intermittent Load ) . Delivery Of Complete Solar Power System Shall Be At Sv-1 ( Between Thoramukh And Numalighar ) , Agcl . Refer Sld -1009-Sv-1-El- Sld -4001 _0 . Solar Power System Shall Be Complete In All Respect . & Systems Functional Responsibility Shall Be In Vendors Scope . Construction Of Battery Room ( Building ) Including Complete Civil Work And Electrical Work As Per Dwg-1009-Cs -Arc-6003 Rev -C1 . Shall Be In Contractors Scope . , Solar Panel System For Sectionalizing Valve Station ( Between Uriumghat And Golaghat ) Solar Power Supply System -3 Kva , 415 V , Ac , 3 Ph , N , ( Solar Panels Have Redundancy- Parallel Redundant 2 Nos X 100 % Rating & Charge Controller Have 2 Nos X 200% Ratings ) Along With Additional Battery Charger & Nickel Cadmium Battery Bank With Battery Rack ( Suitable For Solar Charging , As Per Specification And Datasheet ) . Battery Bank Suitable For Sufficient Backup Time At Full Load Shall Be Provided For Meeting Critical Loads That Cannot Withstand Even A Momentary Interruption In Voltage . Battery Banks - ( 2Nos . X 50% Ni-Cd Battery Bank For 10 Hours Battery Backup For 3 Kw Continious Load & 15 Minute Back-Up For 2 Kw Intermittent Load ) . Delivery Of Complete Solar Power System Shall Be At Sv-2 ( Between Urimghat And Golaghat ) , Agclrefer Sld -1009-Sv-2-El- Sld -4001 _0 . Solar Power System Shall Be Complete In All Respect . & Systems