Military Engineer Services-MES has published Repair Replacement Of Lt Distribution Network Lt Oh Conductor Lt Pole Insulator Guard Wire Stay And Service Connection In East Side Etc Under Ge East Agra. Submission Date for this Tender is 22-07-2020. Conductor Tenders in AGRA Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: Repair / replacement of Lt Distribution network, LT OH conductor , LT pole , insulator , guard wire , stay and service connection in East side etc under GE (E) Agra. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Note: Please refer schedule 'A' notes given on serial page No. 13 to 15 before quoting the tender. | |||
2 | 2 | Dismantling of ACSR conductor of any size/type from existing OH Line and depositing to AGE E/M Yard complete all as specified and directed | 5 | Qtl | |
3 | 3 | Dismantling of GI earth wire and depositing to AGE E/M yard complete all as specified and directed | 2 | Qtl | |
4 | 4 | Dismantling of insulators any size type from existing OH Line and depositing to AGE E/M Yard complete all as specified and directed | 300 | Each | |
5 | 5 | Dismantling of cross arms from existing HT/LT OH Lines of M.S. work/guard cradles etc. of any size of Channel or angle iron sections, clamps, nuts, bolts etc and depositing to AGE E/M Yard complete all as specified and directed | 2 | Qtl | |
6 | 6 | Dismantling of unserviceable stay assembly of any type and size including stay wire insulator etc complete all as specified and directed | 10 | Each Set | |
7 | 7 | Dismantling of existing unserviceable steel tubular/cement concrete broken pole of any type and any size and depositing to AGE E/M yard complete all as specified and directed | 20 | Each | |
8 | 8 | Removing of old paint by removers scrubing from LT electric panel ( Feeder Piller Box ) any type complete including angle iron legs etc for painting and M & L for painting with two coat of superior quality synthetic paint with approved colours on exposed surface of panel complete Including one coat of primer and writing letters or figures (Block, Roman, Italic or Indian) n exc. 20 cm high and drawing stops, commas, short lines, dashes, hyphens, brackets etc. with synthetic enamel paint complete all as specifiedand directed. Note - 1) Colour of synthetic enameld paint will be approved by GE. 2) Stages passing by GE will required after each activity i.e removal of old paints, primer , painting , 1st coat of painting & 2nd coat of painting of synthetic enameld paint. | 20 | sqm | |
9 | 9 | Repairing, servicing ,and making serviceable LT electric panel ( Feeder Piller Box ) any type complete including dressing/proper connection to control wiring with new stranded copper wir not less than 2.5 sqmm wires/ tightening loose connections, and including replacement of defective minor items such as nuts, bolts,lugs,cable gland as required and washers etc complete all as specified and directed .\nNote : Replacement of major defective items such as voltmeter, MCCB, MCB, Bus bar , CRCA sheet , painting , amp meter etc shall be measured and paid seperately under respective item. | 10 | Each | |
10 | 10 | Supply , instalation ,testing ,commissioning Volt meter digital with inbuilt selector switch suitable for 3 phase, 50 HZ , 440 Volts and having accuracy 0.5 CL including necessary wiring , cutting, bending and taking down unservicable voltmeter as specified and directed . Make : Schneider product code DM 3210 or equivalent in L&T / ABB /AE | 4 | Each | |
11 | 11 | Supply , instalation ,testing ,commissioning Amp meter 0 - 800 Amp with CT & inbuilt selector switch suitable for 3 phase, 50 HZ , 440 Volts and having accuracy .0.5 CL including necessary wiring , cutting bending complete all as specified and directed . Make : Schneider product code DM 3110 or equivalent in L&T / ABB /AE | 4 | Each | |
12 | 12 | M&L for plain cement concrete type C-2 1:3:6 (using 40mm stone aggregate) in foundations, filling and mass concrete for foundation, base for transformer, electric piller box etc complete all as specified and directed. | 2 | Cum | |
13 | 13 | M&L for 100 mm thick Cement concrete type B-1 :2:4 (using 20 mm graded stone aggregate) in hard standing and plinth protection etc complete all as specified and directed. | 100 | Sqm | |
14 | 14 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (Fe-290(Gde E-165)- (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. | 100 | Kg | |
15 | 15 | Supplying and fixing in repair MCCB, 400 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu =Ics = 75% 36 KA with Tharmal Magnetic release complete all as specified and directed. Make Cat No 4220 07 of Legrand or equivalent in Schiider/ ABB | 3 | Each | |
16 | 16 | Supplying and fixing in repair MCCB, 320 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu =Ics = 75% 36 KA with Tharmal Magnetic release complete all as specified and directed.. Make Cat No 4220 06 of Legrand or equivalent in Schiider/ ABB | 2 | Each | |
17 | 17 | Supplying and fixing in repair MCCB, 250 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu =Ics = 75% ,36 KA withTharmal Magnetic release complete all as specified and directed.. Make Cat No 4202 49 of Legrand or equivalent in Schiider/ ABB | 4 | Each | |
18 | 18 | Supplying and fixing in repair MCCB, 100 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu =Ics = 75% ,25 KA withTharmal Magnetic release complete all as specified and directed.. Make Cat No 420055 of Legrand or equivalent in Schiider/ ABB | 4 | Each | |
19 | 19 | M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burned directly in ground ( earth pit not less than 2.5 M below normal ground level ) with top edge of the plate not less than 1.75 M below normal ground level connected to and including galvanized steel Strip of size 32 x 6 mm as earth lead Earth plate to bldg test point including 40mm GI light grade pipe for earth protection from earth point to earth plate surrounded by 150mm thick alternate layers of charcoal dust mix all with 35% common salt, 20mm bore medium grade GI Pipe for watering PCC pit type 1:3:6 type C-1 using 20mm graded stone aggregate, with RCC 50mm thick cover in 1:2:4 TYPE B-1 reinforced with 8mm dia CTD bars @8mm e/c both way. GI check nut, funnel with wire mesh necessary excavation and earth work in any type of soil all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 .Note : 1. Result of earhiing shall not be more than 1 ohms , all earthing work will be rework if result not achieved\n2. Earth lead with GI Protection Pipe upto 7.5 meter shall be included in quoted rate of the item. | 20 | Each Set | |
20 | 20 | Supply and errection of steel tubular swaged pole 09 M long type 410-SP-31 confirming to latest applicable IS complete with CI base plate. Finial taper plug, bolts, nuts and screws etc Painting inside with black bitumen paint and out side with two coats of aluminum paint over one coat of red oxide Primer and numbering of poles by white colur on black base and black & white striping up to 1.5 Mtr height, 300mm wide complete all as specified and directed Make NTC/ Bharat conduit/Jindal steel\nNote Earth work and PCC shall be mesured and paid seperetly | 20 | Each Job | |
21 | 21 | Fixing only retrieved cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including providing new nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide and two coats of aluminium paint, complete all as specified. | 1 | Qtl | |
22 | 22 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide and two coats of aluminium paint, complete all as specified.Make Tata/Jindal/ Sail | 1 | Qtl | |
23 | 23 | Restringing of existing OH line, of ACSR/GI earth wire of any size/type on existing OH line restraching properly and fixing on existing insulators on OH cross arms of poles including disconnection service connection street light fitting etc and reconnecting the same after restraching complete all as specified and directed \nNote : All conductor on LT line will be measured as one length) | 5000 | RM | |
24 | 24 | Supplying, fixing, stringing of aluminum conductor steel reinforced (ACSR) including binding wire for binding to aluminum conductor properly on insulators at least 50mm on existing/ new pole over head lines, jumpring, connection and jointing and testing complete all as specified and directed. Make:Indial alluminium Co/Bharat conductor/Alind \nNote : (i) cost of Jumper is deemed to be included in the rate | 5 | Qtl | |
25 | 25 | Supplying, fixing, stringing of GI continuous earth wire of any size 3.15mm or 4.00mm dia on existing overhead line along pole/earthing etc complete all as specified and directed. | 2 | Qtl | |
26 | 26 | S & F shackle type insulator, porcelain vitreous white, brown or green insulator including one galvanized mild steel strip 31x3mm size, washer ,insulator bolts, 12mm dia nut for working pressure 1100 volts grade 75mm height ,90mm max dia complete complete all as specified and directed. Make Jaipuriya/ Rashtriya/ BHEL | 100 | Each | |
27 | 27 | S&F pin type insulator vitreous, white, brown or green including one galvanized MS spindle two G I washer and one G I nut of size 100mm height 65mm dia for 1100 Volt grade complete all as specified and directed. Jaipuriya/ Rashtriya/ BHEL | 200 | Each | |
28 | 28 | M&L for stay assembly complete comprising of 7/3.15mm galvanized stay stranded wire of required length to pole with and including flat iron clamp bolt, nuts and washers etc. including galvanized 14mm dia 400mm long stay bow with 20mm dia 215 cm and long stay rod with threaded ends G.I. nuts and washers galvanized steel plate of size 300x300x 6mm thick , 2 Nos thimble, MS clamps made out of 50 x6 mm flat iron loop insulator 90mmx140mm dia hole, 25mm porcelain complete all as specified and shown in electrical plate No. 1 of SSr Part-I \nNote: Earth work and PCC shall be measured separately | 10 | Each Set | |
29 | 29 | Trimming of tree branches upto 100mm thick and around 1.5 mtr HT/LT OH line complete all as specified and directed \nNote :- Shut down of area shall not be given for more than 4 Hours/ day. | 4000 | RM | |
30 | 30 | Removing of old paint by removers scrubing from LT steel poles 9 meter long, cross arms clamps etc for painting and M &L for painting with one coat of superior quality aluminum paint on exposed surface of poles and street light bracket mounted on the poles,junction box etc and making black strip upto1.5 Mtr height from ground level and writing pole Nos etc. written on it with black synthetic enamel paint compete all as specified and directed \n Make of paint : Asian Paint(Apcolite), Shalimar(Superlac Hi Gloss), Nerolac Paint (Nerolac full Gloss). | 200 | Each | |
31 | 31 | Disconnecting/taking out of existing old unserviceable under ground cable any description, any size and in any position complete all as specified and directed. | 1300 | RM | |
32 | 32 | Excavation in trenches in soft/loose soil N. exc 1.5 Mtr wide and not exc. 1.5 Meter deep and getting out including forming bottom surface for laying of cable complete all as specified and directed. | 450 | Cum | |
33 | 33 | Returning filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified. | 300 | Cum | |
34 | 34 | Removing surplus soil to a distance n.exc 50 Mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified. | 150 | Cum | |
35 | 35 | Supplying and laying sand cushioning for cable protection in trenches /filling in ducts at Sub Stations complete all as specified and directed. | 160 | Cum | |
36 | 36 | Supplying and laying bricks old size sub class ‘B’ laid flat across the cable with length of whole brick for protection of cable complete all as specified and directed. | 15 | Per 1000Nos | |
37 | 37 | M&L for drilling suitable dia horizontal bore holes for insertion/ laying of 80mm/50mm bore HDPE pipe of any description below/under existing road surfaces / floors at a level not less than 0.60 mtr etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed by Engineer-in-Charge. \nNote : (i) Cost of equipment tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the Govt. | 40 | RM | |
38 | 38 | M & L for HDPE pipe light grade 75 mm dia laid in bore holes/trenches/drain/culvert or fixed along with pole/wall including necessary clamps = including nut, bolts etc. complete all as directed. | 40 | RM | |
39 | 39 | M & L for GI pipe light grade 80 mm dia with all fitting laid in bore holes/trenches/drain/ culvert or fixed along with pole/wall including 02 Nos FI clamps of 25x3 mm including nut, bolts etc. complete all as directed. Make TATA/Jindal/ Prakash | 20 | RM | |
40 | 40 | M & L for GI pipe light grade 50 mm dia with all fitting laid in bore holes/trenches/drain/ culvert or fixed along with pole/wall including 02 Nos FI clamps of 25x3 mm including nut, bolts etc. complete all as directed. Make TATA/Jindal/ Prakash | 30 | RM | |
41 | 41 | Supply and laying in trenches/pipi/on wall and connecting and testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100V grade ISI Marked IS 7098 (Pt-I) of size 400 Sq mm 3.5 core complete all as specified and directed. Make Havells/ Gloaster/Polycab/Grandlay | 100 | RM | |
42 | 42 | All as per item No 41.00 above but 120 Sq mm 3.5 core complete | 200 | RM | |
43 | 43 | All as per item No 41.00 above bu 70 Sq mm 3.5 core complete | 300 | RM | |
44 | 44 | All as per item No 41.00 above bu 50 Sq mm 3.5 core complete | 300 | RM | |
45 | 45 | All as per item No 41.00 above bu 35 Sq mm 3.5 core complete | 300 | RM | |
46 | 46 | All as per item No 41.00 above bu 16 Sq mm 4 core complete | 1000 | RM | |
47 | 47 | Supply and fix in repair PVC seperator for over head line for 4 conductor complete with jointing material and accessories compete all as specified and directed | 50 | Each | |
48 | 48 | Supply and fix in repair PVC seperator for over head line for 2 conductor complete with jointing material and accessories compete all as specified and directed | 50 | Each | |
49 | 49 | Supply and fix cable jointing kit suitable for 1100 Volts grade LT cable for indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 16 to 35 sqmm. Make : 3M / M-seal/ Denson/Reychem | 20 | Each\nJob | |
50 | 50 | All as per item No 49.00 above but 50 Sq mm to 95 Sqmm | 20 | Each\nJob | |
51 | 51 | All as per item No 49.00 above but 120 Sq mm to 240 Sqmm | 10 | Each\nJob | |
52 | 52 | All as per item No 49.00 above but 400 Sqmm | 4 | Each\nJob | |
53 | 53 | S & F in repairs of sheet metal enclosure suitable for MCCB 160 Amp type complete all as specified and directed Make- Legrand cat No 5078 01 equivalent to Schneider/ ABB | 4 | Each | |
54 | 54 | S & F in repairs of sheet metal enclosure suitable for MCCB 250 Amp type complete all as specified and directed Make- Legrand cat No 5078 02 equivalent to Schneider/ ABB | 4 | Each | |
55 | 55 | S&F MS sheet metal enclosure Busbar Chamber of 200 amps 4 way including electric connection ,etc with and including FI clamp made out of 50 mmx 3 mm , nut and bolts complete all as specified and directed. Make havells Cat pt No IHBC020004 OR EQUIVALANT TO LEGRAND/SCHIEDER | 4 | Each | |
56 | 56 | S&F MS sheet metal enclosure Busbar Chamber of 315 amps 4 way including electric connection ,etc with and including FI clamp made out of 50 mmx 3 mm , nut and bolts complete all as specified and directed. Make havells Cat pt No IHBC031504 OR EQUIVALANT TO LEGRAND/SCHIEDER | 2 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail