Military Engineer Services-MES has published Repair / Maintenance Of Summer Cooling Appliances Solar Heater Etc At 1 Afsb Dehradun Under Ge ( Af ) Sarsawa. Submission Date for this Tender is 30-07-2020. Solar Heater Tenders in GE(AF) SARSAWA Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 23-Jul-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 30-07-2020 |
Name of Work: Repair / Maintenance of Summer Cooling Appliances Solar heater etc At 1 AFSB Dehradun Under GE(AF) Sarsawa | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Comprehensive maintenance of air conditionerwindo type 1.5 tonne capacity of any make including performing following tasks at different locations at 1 AFSB Stn :- (a) Inspection, taking down, removing grills and outer housing. (b) Descaling, brushing and cleaning thoroughly and replacing filter pad of AC. (c ) Servicing the cooling fan by greasing/oiling the bearing, bushes after opening the motor, cleaning the armature, checking and tightening all nuts and bolts etc. (d) Checking, rectifying the connection, working of thermostat assembly, relay, condenser, heater assembly, compressor and earth connection etc including replacing defective wire and sleves etc. (e) Re-fixing AC and outer unit of in position, after assembling including packing as required at site and testing complete to make it functional. Note :- Supplying and replacement of parts shall be measured and paid separately. | Item1 | 1 | Each Job |
2 | 2 | Comprehensive maintenance of air conditioner split type 1.5/2 tonne capacity of any make including performing following tasks at different locations at 1 AFSB Stn :- (a) Inspection, taking down, removing grills and outer housing. (b) Descaling, brushing and cleaning thoroughly and replacing filter pad of AC. (c ) Servicing the cooling fan by greasing/oiling the bearing, bushes after opening the motor, cleaning the armature, checking and tightening all nuts and bolts etc. (d) Checking, rectifying the connection, working of thermostat assembly, relay, condenser, heater assembly, compressor and earth connection etc including replacing defective wire and sleves etc. (e) Re-fixing AC and outer unit of in position, after assembling including packing as required at site and testing complete to make it functional. Note :- Supplying and replacement of parts shall be measured and paid separately | Item2 | 90 | Each Job |
3 | 3 | Gas charging of window type AC with gas R-22 after cleaning including making necessary connection, vacumising, brazing, soldering, welding the copper tube and testing on completion all as specified and as directed. | Item3 | 1 | Each Job |
4 | 4 | Gas charging of spilit type AC with gas R-22 after cleaning including making necessary connection, vacumising, brazing, soldering, welding the copper tube and testing on completion all as specified and as directed. | Item4 | 30 | Each Job |
5 | 5 | S & F of running capacitor 36/45/50 MFD including testing complete all as specified and as directed. | Item5 | 5 | Each |
6 | 6 | S&F of starting capacitor 100/120 MFD including testing complete all as specified and as directed. | Item6 | 2 | Each |
7 | 7 | S&F of starting relay for AC of capacity 1.5/2 TR complete all as specified and as directed. | Item7 | 5 | Each |
8 | 8 | Supply and fixing in replacement compressor assembly (sealed unit) for air conditioner window type 1.5 tonne capacity including filling/charging of gas complete all as specified and as directed. (Note : Gas charging shall be measured and paid separately) | Item8 | 1 | Each |
9 | 9 | Supply and fixing in replacement compressor assembly (sealed unit) for air conditioner spilit type 1.5 tonne capacity including filling/charging of gas complete all as specified and as directed. (Note : Gas charging shall be measured and paid separately) | Item9 | 4 | Each |
10 | 10 | Supply and fixing in replacement compressor assembly (sealed unit) for air conditioner spilit type 2 tonne capacity including filling/charging of gas complete all as specified and as directed. (Note : Gas charging shall be measured and paid separately) | Item10 | 4 | Each |
11 | 11 | Supply and replacement of capillary tube complete all as specified and as directed | Item11 | 50 | RM |
12 | 12 | Repairing Aircondition split type Aircondition any size any Make complete all as specified and directed. | Item12 | 3 | Each Job |
13 | 13 | Supply and fixing in replacement of all coils of blower motor of AC 1.5 tonne/2 ton split AC with super enamel copper winding wire of proper gauge, weight etc (having same No’s of turn) winding, using insulating material varnishing, heating, re-assembling the motor after making it functional and testing complete all as specified and as directed. | Item13 | 1 | Each |
14 | 14 | Supply and fixing in replacement of blower motor of AC window type 1.5 tonne capacity all as specified and as directed. | Item14 | 3 | Each |
15 | 15 | S&F in repair wiring kit for AC 1.5/2 ton cap of any make complete all as directed. | Item15 | 4 | Each |
16 | 16 | S&F in repair selector switch 3 way for AC 1.5/2 ton all as directed. | Item16 | 3 | Each |
17 | 17 | S&F in repair thermostate switch for AC 1.5/2 ton cap all as directed. | Item17 | 3 | Each |
18 | 18 | S&F in repair toggle switch for AC 1.5/2 ton cap all as directed. | Item18 | 3 | Each |
19 | 19 | S&F in repair sensor remote switch for AC 1.5/2 ton cap all as directed. | Item19 | 3 | Each |
20 | 20 | Taking out the old/unserviceable heating element from the machine and S&F new heating element for window type AC of Cap 2.5 KW complete all as directed. | Item20 | 1 | Each job |
21 | 21 | Ceiling fan /Exhaust fan/Cabin fan :- Comprehensive maintenance of ceiling fan 1200 mm/1400 mm sweep, any type, make fixed at different locations including taking down, cleaning all dirt, dust etc, opening the fan motor cleaning the winding armature, oiling and greasing the bearing replacement the warn out, unserviceable screws assembly, re-fixing and testing to make it functional complete all as specified and as directed. | Item21 | 50 | Each |
22 | 22 | All as per Serial Item No 21 here-in-before but exhaust fan upto 450 mm size complete all as specified and as directed. | Item22 | 15 | Each |
23 | 23 | S&F of down rod made out of MS conduit pipe, medium grade, 20 mm bore, 1 feet,2feet long, duly painted with nut, bolt, split pin on one side and fan having ‘U’ clamp complete with nut bolt washers, split pin and rubber reel on other side complete all as specified and as directed. | Item23 | 50 | Each |
24 | 24 | Supplying only of condenser 2.5 MFD AC 230 volt complete all as specified and as directed. | Item24 | 100 | Each |
25 | 25 | All as per Serial Item No 24 here-in-above but 4 MFDcomplete all as specified and as directed. | Item25 | 20 | Each |
26 | 26 | Supplying and fixing in replacement of all coils of ceiling fan motor, 230 volt of 1200 mm with super enamel copper winding wire of proper gauge, weight etc (having same nos of turns), winding using insulating materials varnishing, heating, baking, re-assembling the fan after making it functional and testing complete all as specified and as directed.\n(Weight of copper winding wire shall be same as existing ). | Item26 | 20 | Each |
27 | 27 | Supplying and fixing in replacement of all coils of ceiling fan motor, 230 volt 1400 mm sweep, with super enamel copper winding wire of proper gauge, weight etc (having same nos of turns), winding using insulating materials varnishing, heating, baking, re-assembling the fan after making it functional and testing complete all as specified and as directed. (Weight of copper winding wire shall be same as existing ). | Item27 | 10 | Each |
28 | 28 | All as per Serial Item No 26 here-in-above but exhaust fan upto 200/250mm size/sweep complete all as specified and as directed. | Item28 | 10 | Each |
29 | 29 | All as per Serial Item No 26 here-in-above but exhaust fan upto300/ 350 mm size/sweep complete all as specified and as directed. | Item29 | 10 | Each |
30 | 30 | All as per Serial Item No 26 here in above but exhaust fan 400mm/450 mm size/sweep complete all as specified and as directed. | Item30 | 10 | Each |
31 | 31 | S&F exhaust fan blade suitable for upto 450mm sweep complete all as specified and as directed. | Item31 | 8 | Each |
32 | 32 | All as per Serial Item No 26 here-in-above but Cabin fan of any size/sweep complete all as specified and as directed. | Item32 | 10 | each |
33 | 33 | Supplying only of ball bearing suitable for exhaust fan,up to 450 mm size complete all as specified and as directed. | Item33 | 10 | Each |
34 | 34 | Supplying only of ball bearing suitable for ceiling fan and pedestal fan complete all as specified and as directed. | Item34 | 20 | Each |
35 | 35 | Supplying only of gun metal bush suitable for ceiling fan, any sweep complete all as specified and as directed. | Item35 | 6 | Each |
36 | 36 | Supplying and replacement of ceiling fan regulator resistance type including taking out old regulator complete all as specified and directed. | Item36 | 20 | Each |
37 | 37 | Supplying and replacement of ceiling fan regulator electronic type including taking out old regulator complete all as specified and directed.(MAKE : USHA/crompton greaves/bajaj/ anchor). | Item37 | 100 | Each |
38 | 38 | Supply only of fan hanging mild steel ‘U’ clamps of suitable size duly painted for hanging of ceiling fan with nuts, bolts, split pins and rubber real complete all as specified and as directed. | Item38 | 30 | Each |
39 | 39 | Material and labour for spray painting one coat to ceiling fan any sweep fixed at different location with synthetic enamel paint including filling cavities with filler after cleaning all dust, dirt etc including writing MES No as exists and re-fixing complete all as specified and as directed. | Item39 | 50 | Each |
40 | 40 | Reairing Wall mounting fan 400 mm sweep with pull ON-OFF cord, 3 speed option with swing oscillation control wide 90 deg sweep angle with wall mounting bracked complete all as specified and directed. | Item40 | 20 | Each |
41 | 41 | Water heater (Geysers) :- Inspection and maintenance of water heater (Geysers) of capacity, 25 ltrs to 50 litres including performing the following task at different locations at AF Stn Sarsawa.\n(a) Removing the heather plate assembly and decaling the heating element/pipe either by use of acid or equa cleaner to make it functional complete.\n(b) Checking and setting of thermostat between 70 to 80 degree Celsius.\n(c) Check working of NRV stop cock, pressure release valve and servicing carefully to make it functional.\n(d) Repairing of earthing connection, power switch, socket connection replacement of indicator lamp to make it functional.\n(e) Examine water leakage and rectifying as required and replacement of rubber washer gasket etc to make it functional.\n(f) Inspect over flow vent pipe, safety valve and remove blockage if required to make it functional. \n | Item41 | 50 | Each |
42 | 42 | Supply only of heating element of rating 2 KW to geyser 25 to 50 litres capacity, any type, complete all as specified and as directed. | Item42 | 20 | Each |
43 | 43 | Supply only of heating element of rating 1.5 KW to geyser 25 to 50 litres capacity, any type, complete all as specified and as directed. | Item43 | 20 | Each |
44 | 44 | Supply & Fix in repair inner copper tank made out of cold rolled pure electrode type copper sheet double lapped welded internally and hydraulically tested for geyser 50 litres capacity complete all as specified and as directed. | Item44 | 6 | Each |
45 | 45 | Supply & Fix in repair inner copper tank made out of cold rolled pure electrode type copper sheet double lapped welded internally and hydraulically tested for geyser 35 litres capacity complete all as specified and as directed. | Item45 | 6 | Each |
46 | 46 | Supply & Fix in repair inner copper tank made out of cold rolled pure electrode type copper sheet double lapped welded internally and hydraulically tested for geyser 25 litres capacity complete all as specified and as directed. | Item46 | 6 | Each |
47 | 47 | Supply only of the thermostat (adjustable type) suitable for upto 50 litres capacity of geysers. | Item47 | 20 | Each |
48 | 48 | Supplying and fixing in replacement of geyser plate assembly suitable for 25 to 50 litres capacity geysers, of brass with inlet, outlet pipe, drain plug, thermostat chamber fixing heating element gasket nut, bolt etc are fixing the assembly to make it functional complete all as specified and as directed. | Item48 | 3 | Each |
49 | 49 | Supply only of flexible PVC pipe connection, nylon thread reinforced 15 mm dia, 450 mm long with brass union at both ends for 15 mm dia pipe complete all as specified and as directed. | Item49 | 30 | Each |
50 | 50 | Supply and replacement of fusable plug complete all as directed | Item50 | 6 | Each |
51 | 51 | Supply only gasket of thickness 5 mm for geyser assembly of 08 holes/09 holes complete all as specified & directed. | Item51 | 10 | Each |
52 | 52 | S&F in repair indicating lamp for geyser rectangular type complete all as specified & directed. | Item52 | 10 | Each |
53 | 53 | S&F in repair indicating lamp for geyser round type complete all as specified & directed. | Item53 | 5 | Each |
54 | 54 | Supply only metal clad top & socket 15 Amp cap complete all as directed. | Item54 | 10 | Each |
55 | 55 | S&F non return valve for geyser complete all as specified and as directed. | Item55 | 5 | Each |
56 | 56 | Supply only fastener mild steel 100/150/200 mm long complete all as specified & directed. | Item56 | 50 | Each |
57 | 57 | M & L for preparation of body of geyser for painting complete outer surface of any size/capacity with one coat of synthetic enameled paint complete all as specified & directed. | Item57 | 10 | Each |
58 | 58 | Dismantling/taking out the geyser assembly & copper tank and making soldering & brazing of tank and fixing the same in the geyser of any cap. | Item58 | 5 | Each job |
59 | 59 | Water cooler :- Comprehensive maintenance of water cooler various capacity including performing following tasks at different locations at AF Stn Dehradun :-\n(a) Inspection, dismantling front and rear shutters disconnecting electric and water connection.\n(b) Cleaning thoroughly the body of water cooler including cleaning of cold water tank with bleaching powder solution \n(c) Servicing of cooling fan by greasing to bearing, oiling to bushes after opening the motor.\n(d) Checking/rectifying the connection and working of thermostat relays, condenser, evaporator, capacities, switches, electrical connection, float valve, compressor earth connection including replacement of defective wire sleeves etc.\n(e) Replacement of PVC drain pipe from water cooler tray to neared drain.\n(f) Reconnecting power and water lines and testing to make it functional complete all as specified and as directed. \n(Note : Gas charging shall be measured and paid for separately) | Item59 | 6 | Each job |
60 | 60 | Gas charging the water cooler with gas F-22 capacity 40/80/60/150 litres capacity including making necessary connection, testing etc to make it functional complete all as specified and as directed. | Item60 | 6 | Each |
61 | 61 | Supply and replacement of starting relay for water cooler any cap to make functional complete. | Item61 | 6 | Each |
62 | 62 | Supply only of starting capacitor 60/80 MFD for water cooler complete all as specified and as directed | Item62 | 6 | Each |
63 | 63 | Supply and fixing in replacement compressor assembly (sealed unit) of water cooler40 ltr capacity including filling/charging of gas complte all as specified and directed. | Item63 | 3 | Each |
64 | 64 | REFRIGERATOR/Deep Freezer Comprehensive maintenance of refrigerator/Deep Freezer of any capacity make etc by performing the following tasks :-\n(a) Cleaning the refrigerator from inside with bleaching powder solution including cleaning the attached trays.\n(b) Cleaning the complete body thoroughly checking relay and rectifying the functioning of relays, compressor, thermostat electrical connection and condenser pipe including, checking and tighten of all bolt and clamp.\nNote : Supplying and replacement of parts shall be measured and paid separately. | Item64 | 6 | Each |
65 | 65 | Supply & Fix of starting relay suitable for refrigerator of any capacity complete all as specified and as directed. | Item65 | 6 | Each |
66 | 66 | Supply & Fix only of thermostatic switch with defrosting arrangement suitable for refrigerator of any capacity make and size all as specified and as directed. | Item66 | 6 | Each |
67 | 67 | Gas charging of refrigeratorof any capacity including making necessary connection, testing complete all as specified and as directed. | Item67 | 6 | Each |
68 | 68 | S&Replacement of electronic chip(PCB) including defrost timer,biometal for refrigerator of capacity 165 to 315 ltrs of LG/Samsung. | Item68 | 5 | Each |
69 | 69 | S&F in repair MCB SP 20 Amps with 3 pin top and metal clad socket 20 Amps with sheet metal enclosure mounted complete all as specified & directed. | Item69 | 5 | Each |
70 | 70 | Dismantling the voltage stabilizer 230/250 Volts 0.5 KVA and replace the unserviceable parts and reassembling the same after necessary repair & testing & commissioning the repaired stab in presence of Engr-in-charge complete all as specified & directed. (Note : Cost of UNSV parts will be included in the quoted rates) | Item70 | 5 | Each Job |
71 | 71 | All as per item No.70 above but 1.0 KVA cap complete all as specified and as directed. | Item71 | 5 | Job |
72 | 72 | All as per item No.70 above but 2.0 KVA cap complete all as specified and as directed. | Item72 | 5 | Job |
73 | 73 | All as per item No.70 above but 5.0 KVA cap complete all as specified and as directed. | Item73 | 5 | Job |
74 | 74 | Desert cooler Comprehensive maintenance of desert cooler of any type and any make, fixed at different location at 1 AFSB Dehradun including taking down, cleaning gall dirt, dust, oiling of motor and pump, checking of parts, including replacement of nuts bolts, screw etc and preparation of the desert cooler body and tank by scrubbing the old paint and spray painting with two coat of synthetic enamel paint and spray painting with two coats of synthetic enamel paint complete all as specified and as directed\nNote : Supply and replacement of parts shall be measured and paid separately.S&F socket outlet 2 in 1 , 5 pin , 5A all as specified & directed. | Item74 | 15 | Each |
75 | 75 | Supply only of show grill of any size make and capacity of desert cooler of PVC of make as approved by GE. | Item75 | 15 | Each |
76 | 76 | Supply only of wood wool pads of best quality as approved with and including wire mesh jalli for desert cooler of any size make and capacity all as specified and as directed. | Item76 | 20 | Set of three |
77 | 77 | Supply and fixing in replacement of PVC elbows of suitable size all as specified and as directed. | Item77 | 20 | Each |
78 | 78 | Supply and fixing in replacement of PVC pipe of superior quality 15mm dia suitable for desert cooler all as specified and as directed. | Item78 | 50 | RM |
79 | 79 | Supply and fixing in replacement of fan motor for desert cooler complete with blade, locknut, with all accessories 220/250 Volt of all as specified and as directed. | Item79 | 10 | Each |
80 | 80 | Supply and fixing in replacement of desert cooler pump motor 230/250 Volt, 50 C/S complete with mounting accessories all as specified and as directed. | Item80 | 10 | Each |
81 | 81 | Supply and fixing in replacement ply wood grade BWR, type BB, having one face decorated veneer, 3 mm thick fixed with screw to the size and shape in one piece as directed by the Engineer-in-Charge including necessary cutting fixed at site for desert cooler with including all packing material to make it air tight complete all as specified and as directed. | Item81 | 10 | Sqm |
82 | 82 | Supply and fixing in replacement of indicating lamp for motor and pump including holder all as specified and as directed. | Item82 | 50 | Each |
83 | 83 | Supply and fixing in replacement of plug top 5 amp 3 pin suitable for desert cooler all as specified and as directed. | Item83 | 20 | Each |
84 | 84 | Supply and fixing in replacement of fan mounting bracket set as required for desert cooler all as specified and as directed | Item84 | 5 | Each |
85 | 85 | Disconnecting and Dismantling old u/s solr water heating system complete set and reparing and servicing , and refitting the same location of 100 ltr to 500 ltr size any make, Necessary spares are including the quoted Rate complete all as specified and directed by engineer in charge. | Item85 | 12 | Each Job |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy