Repair / Replacement/ Maintenance Of Control Panels , Level Sensors , Valve Automation And Other Essential Repairs In Water Supply Installations At Ge ( U ) Chandimandir, Chandimandir Cantt-Haryana

Military Engineer Services-MES has published Repair / Replacement/ Maintenance Of Control Panels , Level Sensors , Valve Automation And Other Essential Repairs In Water Supply Installations At Ge ( U ) Chandimandir. Submission Date for this Tender is 21-07-2020. Control Panel Tenders in Chandimandir Cantt Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

24754052
Corrigendum : Repair / Replacement/ Maintenance Of Control Panels , Level Sensors , Valve Automation And Other Essential Repairs In Water Supply Installations At Ge ( U ) Chandimandir
Open Tender
Indian
Haryana
Chandimandir Cantt
21-07-2020

Tender Details

Repair / Replacement/ Maintenance Of Control Panels , Level Sensors , Valve Automation And Other Essential Repairs In Water Supply Installations At Ge ( U ) Chandimandir

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Jul-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-07-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work: REPAIR / REPLACEMENT/ MAINT OF CONTROL PANELS, LEVEL SENSORS, VALVE AUTOMATION AND OTHER ESSENTIAL REPAIRS IN WATER SUPPLY INSTALLATIONS AT CHANDIMANDIR CANTT
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply, Installing,Testing and Commissioning in replacement Ultrasonic Level Transmitter at Overhead tank/Underground sump for measurement of level with following specification:- \nRange : not less than 6 mtrs \nAccuracy : 0.5 % minimum \nSupply Voltage : 24V DC \nOutput : 4-20 mA , 0-10V DC \nMake: PEPPERL+ FUCHS / NIVELCO / SIEMENS EMERSON / USGC / ENDRESS+HAUSER item1 20 Each
2 2 Supply, installation, testing and commissioning of Water Level Indicator and controller suitable for monitoring of 01 Nos. Ultrasonic Level Transmitter. The front facia of the panel shall be made out of ink jet printed laminated latex on vinyl . The panel should be Indoor/outdoor type factory made 2 mm CRCA sheet and properly powder coated mounted on wall or grouted in floor using angle iron base frame of appropriate size and grouted using PCC 1:2:4. Make of panel:- GE Automation & Control/ABB Automation/ Universal Switch Gear Control/ Siemens/ Endress + Hauser. The Panel should comprise the following items :-\n(a) Water Level Sensing & Display. (b) Suitable number of interposing relays 24 V DC and 220V AC coil rating and 1 A contact rating. (Make: OEN / OMRON / ALLEN BRADLEY / SCHNEIDER / SIEMENS). (c) 01 Nos. Numeric Controller for Parameterization interface, Synchronization, Display and Control of the analog variables having Digital Numeric Display. (Make: AUTONICS / OMRON / UNIVERSAL / Endress + Hauser). (d) 01 No. SMPS of 1.5 A rating (Make: SCHNEIDER / OMRON/ ABB / SIEMENS). (f) MCB rating 6A (Make:- Legrand/ Schneider / Siemens/ ABB ). (g) Indicating lamp:- As per requirement(Make:- Schneider / ESBEE / Siemens/ ABB ). (h) Selector switches:- As per requirement (Make:- Schneider/ ESBEE / ABB / Siemens). (i) Buzzer 220V AC / 24V DC (Make:- Universal / MIMIC) \n item2 20 Each Job
3 3 S & F 4 pair CAT 6 UTP cable for Sensors complete all as specifed and directed.\nMake : D Link/ Finolex/ Polycab or equivalent as approved by GE item3 700 RM
4 4 Supply and Fix 6 Core 1.5sq.mm. PVC sheathed PVC insulated copper armoured cable complete all as specified and directed.\nMake: Havells/Polycab/Gloster or equivalent as approved by GE. item4 250 RM
5 5 S & F in replacement single phase electrically actuated ductile iron butterfly valve suitable with nominal dia 150mm PN-16, suitable for potable water application, 230 V AC/24 V DC, alongwith starter/control panel, positioner transmitter complete all as specified and directed. item5 3 Each
6 6 M & L for repair / servicing of brush cutter petrol type, 4 stroke Make: Honda Model No: UMK 435T after dismantling all parts and replacement of unserviceable minor parts such as bearing and bushing, piston, pinions, valves, belts, lubricants and major parts complete to make it fully functional complete all as required by Engineer-in-Charge. Note: 1. Quoted rates shall be includes cost of minor parts. 2. Major spare parts shall be measured separately as supply only here in after. item6 3 Each Job
7 7 Supply only carburetor assy part No: BE - 16100-Z0T-911 complete all as specified and directed. item7 3 Each
8 8 Supply only ignition coil assy part No: 30500-ZL8-014 complete all as specified and directed. item8 3 Each
9 9 Supply only air cleaner element part No: 17210-ZF5-505 complete all as specified and directed. item9 3 Each
10 10 Supply only starter assy part No: 28400-ZE2-W02ZN complete all as specified and directed. item10 3 Each
11 11 Supply only brush cutter machine string of existing make all as directed. (Note: Each packets contains of 50m strings) item11 4 Each Pkt
12 12 Taking out sluice valve and opening up of leaking sluice valve of size 80mm bore refacing, regrinding and refixing after repacking of stuffing box and including replacement of SS spindle, gland packing, nuts, bolts and washers etc complete all as specified. item12 15 Each
13 13 All as per item Sr No: 12 but 100 mm bore item13 10 Each
14 14 All as per item Sr No: 12 but 150 mm bore item14 20 Each
15 15 All as per item Sr No: 12 but 200 mm bore item15 10 Each
16 16 All as per item Sr No: 12 but 250 mm bore item16 5 Each
17 17 All as per item Sr No: 12 but 300 mm bore item17 2 Each
18 18 Taking down carefully exisiting Pressure pump of 1 HP capacity, 50 Hz, 230 V AC, Single phase with Pressure setting from 2 Bar-5 Bar, along with 19 Ltr Pneumatic pressure tank and shifting motor-pump set to workshop for repair/servicing comprising strip opening of pumps/motor, replacement of defective parts carrying out necessary lathe work, re-assembling motor-pump set and shifting from work shop to site for and including re-installation with necessary bolts, nuts & washers, complete all as specified and as directed by Engineer-in- charge. Note: Spare parts shall be measured and paid separately under respective items here-in-after as supply only. item18 4 Each Job
19 19 Supply only spring loaded pressure switch/relay for automatic operation of pump in case of pressure drop complete all as specifed and directed. item19 4 Each
20 20 Supply only pressure gauge of appropriate size for sensing line pressure complete all as specifed and directed. item20 4 Each
21 21 Supply only 19-24 Ltr Pneumatic pressure tank with diaphragm for separation of air and water complete all as specifed and directed. item21 3 Each
22 22 Supply only SS impeller as per IS 3444 Grade 4 for pump complete all as specifed and directed. item22 2 Each
23 23 Supply only SS casing wear ring, impeller wear ring, pump shaft and shaft sleeve complete all as specifed and directed. item23 4 Each set
24 24 Demolition of cement concrete (Un-reinforced) of any description and in any position not otherwise specifically provided for including disposal of unserviceable material complete all as specified and as directed. item24 20 Cum
25 25 M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate for packing of pump sets foundations /to support the pipe line etc, including necessary form work, complete all as specified and directed. item25 20 Cum
26 26 Demolition of brick work built in cement mortar including all quoins, arches, piller etc complete all as specified and as directed. item26 10 Cum
27 27 M & L for brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius, built in 1:4 cement mortar complete all as specified and directed item27 10 Cum
28 28 M&L for 15mm thick cement plaster in CM 1:4 on fair faces of brick work or concrete surface finish even and smooth without using extra cement complete all as specified and directed item28 100 Sqm
29 29 M&L for injection pressure grouting in weak areas in internal floor /walls of over head tank/reservoir at any height by drilling 12 mm dia grout holes to 70 % depth inclined at an angle, fixing non ferrous metallic nozzle (having suitable locking arrangement) with approved instant setting compound, injecting the slurry of water and cement admixture with plasticised grout admixture at 140 psi as specified till rejection of the material using a grout pump having suitable gauge for indicating pressure sealing of top 25 to 50 mm of the grout hole with instant setting compound as recommended and and cutting the projected portion of nozzle in level with existing surfaces complete all as specified and directed . The spacing between two grout holes shall not be more than 100 cm c/c. Note: Quoted rate shall deemed to be inclusive of item29 800 Each Nozzle Point
30 30 Supply only cement 43 grade of approved manufacturer for preparing the slurry complete all as specified item30 40 Bag of 50 Kgs
31 31 Supply only plasticised grout admixture complete all as specified and directed. Make - Cebex 100-Fosroc/Drip Seal/MC Bauchamie India Pvt Ltd or equivalent as approved by GE item31 900 Kg
32 32 Note: 1 For Makes of all items refer Appx 'A' and 'B' of tender documents. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit Revised in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site. item32
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail