Construction Of Boundary Wall And Tube Well At Nursing College , Dhadholi , Distt . Alwar ( Under Msdp ) , Alwar-Rajasthan

Medical Health And Family Welfare has published Construction Of Boundary Wall And Tube Well At Nursing College , Dhadholi , Distt . Alwar ( Under Msdp ) . Submission Date for this Tender is 10-07-2020. Tube Well Tenders in Alwar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

24751957
Construction Of Boundary Wall And Tube Well At Nursing College , Dhadholi , Distt . Alwar ( Under Msdp )
Open Tender
Indian
Rajasthan
Alwar
10-07-2020

Tender Details

Construction Of Boundary Wall And Tube Well At Nursing College , Dhadholi , Distt . Alwar ( Under Msdp )

Key Value

Document Fees
INR 500 /-
EMD
INR 56280.0 /-
Tender Value
INR 28.14 Lakhs /-

BOQ Items

Name of Work: Construction of Boundary wall and Tube Well at Nursing College, Dhadholi, Distt. Alwar (Under MSDP)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Part 'A' : Civil Work BI01010001010000000000000515BI0100001112
2 1.01 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. \nAll kinds of soils BI01010001010000000000000515BI0100001113 349 Cum
3 2 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix\n1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate \n40 mm nominal size). BI01010001010000000000000515BI0100001114 58 Cum
4 3 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.\nM20 grade Nominal Mix / Design Mix BI01010001010000000000000515BI0100001115 3 Cum
5 4 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. BI01010001010000000000000515BI0100001116 16 Sqm
6 5 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) BI01010001010000000000000515BI0100001117 320 Kg
7 6 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). BI01010001010000000000000515BI0100001118 316 Cum
8 7 Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in :Cement Mortar 1:6 ( 1-Cement : 6-Sand). BI01010001010000000000000515BI0100001119 208 Cum
9 8 Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification .75mm thick. BI01010001010000000000000515BI0100001120 191 Sqm
10 9 Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification : BI01010001010000000000000515BI0100001121 166 Sqm.
11 10 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20 mm thick BI01010001010000000000000515BI0100001122 765 Sqm.
12 11 Pointing on stone masonry in cement sand mortar 1:3 (1 cement : 3 sand) :Raised and cut pointing. BI01010001010000000000000515BI0100001123 765 Sqm,
13 12 Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding.\n New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). BI01010001010000000000000515BI0100001124 1696 Sqm.
14 13 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : \nTwo or more coats on new work BI01010001010000000000000515BI0100001125 50 Sqm.
15 14 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. Extra if square,rectangular hollow tubelar sections are used or grill made by flats only BI01010001010000000000000515BI0100001126 369 Kg.
16 15 Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casing pipes as per IS:2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe :200 mm dia Nominal bore. BI01010001010000000000000515BI0100001127 240 Rmt
17 16 Construction of tube-well from ground levels and upto 100 Meter depth and above to accommodate housing and assembly pipe of following sizes in all types of alluvium strata by percussion / rotary drilling method and with gravel as per IS:4097-1967 and packing as per IS:2800 (Part I & II) 1979 as amended upto date (the work includes the cost of gravel & its primary packing and packing during development, lowering of housing & strainer assembly pipes, with supply and wrapping of coir rope, wherever necessary, for arresting fine sand particles. The work will not include cost of housing pipe and strainer pipe assembly and development work, but work would be completed after obtaining sand free water).200 mm Nominal bore. BI01010001010000000000000515BI0100001128 30 Rmt
18 17 Development of tube well as per IS specification using suitable compressor to give and free water for required yield of the gravel packed tube well. BI01010001010000000000000515BI0100001129 5 Hrs.
19 18 S & F tube well cover of tube well cover of M.S. sheet (6mm thick) with nuts and bolts complete for casing size :200mm dia. BI01010001010000000000000515BI0100001130 1 Each
20 19 S & F M.S. clamp, set of 50x6mm flat from ion with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. BI01010001010000000000000515BI0100001131 1 Each
21 20 Supplying and installation of 32 mm dia G.I. pipe medium class ISI marked in 3m length including all accessories and fittings required for installation of hand pump. BI01010001010000000000000515BI0100001132 160 Rmt
22 21 P & F Gun-metal Non-return Valve or Check Valve (IS:Make) of approved make, superior quality :32 mm nominal bore. Veritcal BI01010001010000000000000515BI0100001133 1 Each
23 22 P & F Full-way valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 32 mm nominal bore. BI01010001010000000000000515BI0100001134 1 Each
24 23 Supply of ERW M.S. black casting pipe ISI marked (IS:4270/1992) of grade Fe 410 of following sizes at site of work.200 mm nominal bore BI01010001010000000000000515BI0100001135 150 Mtr
25 24 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985.200 mm Nominal Bore. BI01010001010000000000000515BI0100001136 18 Mtr
26 25 P/Laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required.4.0 Sq.mm 3 core flat / Round BI01010001010000000000000515BI0100001137 170 Rmt
27 26 SITC of radial / mixed flow submersible motor pump sets ISI marked (IS:8034-1989) of approved make with required accessories including making connection suitable for T.W./ D.C.B./ Open well. The job includes lowering of riser pipe, G.I./ H.D.P.E. pipe with rope, cables, installation of complete fitting and accessories, jointing of electrical cables up to switch board. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. 100 mm diameter Submersible pump shall have following HP Rating, phase, Head, minimum Discharge respectively. \n5.0 HP, 1-Ø, (55-150)Mtr, (166-60)LPM BI01010001010000000000000515BI0100001138 1 Each
28 27 Supply and fixing of Oil / Air break Starter panel made out of sheet steel powder coated enclosure comprising of over load protection relay, short circuit & single phasing protection, ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. complete in all respect suitable for following rating motors.\nFor single phase Submersible / Monoblock pump 0.5 HP to 3.0 HP BI01010001010000000000000515BI0100001139 1 Each
29 28 P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required.\nDouble door (single phase) 6 Way BI01010001010000000000000515BI0100001140 1 Each
30 29 P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.\nDouble pole MCB \n6 A to 32 A rating BI01010001010000000000000515BI0100001141 1 Each
31 30 P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.\nSingle pole MCB\n6 A to 32 A rating BI01010001010000000000000515BI0100001142 4 Each