Manning And Operation And Maintenance Of 11 Kv Sub Station At Mrs Nausenabaugh And Other Misc Works At Nsb Ncs Key Personnel Colony Sho Nsb Area Under Age E/M-I Of Ge ( U-I ) Visakhapatnam, Garrison Engineer Utility-I Visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Manning And Operation And Maintenance Of 11 Kv Sub Station At Mrs Nausenabaugh And Other Misc Works At Nsb Ncs Key Personnel Colony Sho Nsb Area Under Age E/M-I Of Ge ( U-I ) Visakhapatnam. Submission Date for this Tender is 18-07-2020. Keys Tenders in Garrison Engineer Utility-I Visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

24743137
Manning And Operation And Maintenance Of 11 Kv Sub Station At Mrs Nausenabaugh And Other Misc Works At Nsb Ncs Key Personnel Colony Sho Nsb Area Under Age E/M-I Of Ge ( U-I ) Visakhapatnam
Open Tender
Indian
Andhra Pradesh
Garrison Engineer Utility-I Visakhapatnam
18-07-2020

Tender Details

Manning And Operation And Maintenance Of 11 Kv Sub Station At Mrs Nausenabaugh And Other Misc Works At Nsb Ncs Key Personnel Colony Sho Nsb Area Under Age E / M-I Of Ge ( U-I ) Visakhapatnam

Key Value

Document Fees
INR 500 /-
EMD
INR 97000.0 /-
Tender Value
INR 48.50 Lakhs /-

BOQ Items

NAME OF WORK : MANNING AND OPERATION AND MAINTENANCE OF 11 KV SUB STATION AT MRS NAUSENABAUGH AND OTHER MISC WORKS AT NSB NCS KEY PERSONNEL COLONY SHO NSB AREA UNDER AGE E/M-I OF GE(U-I) VISAKHAPATNAM
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Out sourcing for operation and maintenance of HT/LT Electrical Sub Stations at NausenaBaugh to the equipments installed round the clock in 03 shifts of 08 hours each all as per the details given below:- \nOut sourcing : Minimum one skilled electrician and one mate electrician per shift of 08 hours \n \n 1005 Per Shift of 08 Hrs
2 1.01 Details of plants and Equipments:
3 1.02 (I) HT VCB's - 5 No
4 1.03 (ii) HT OCB - 1 No
5 1.04 (iiI) Transformers 150 KVA to 800 KVA -13 Nos.
6 1.05 (iv) RMUs- 17 No
7 1.06 (v) LT Panels of various sizes - 68 Nos
8 1.07 Note :
9 1.08 (i) Contractor is responsible to keep the installations clean and tidy by using cleaning agents / Cloths etc daily as directed.
10 1.09 (ii) The contractor is responsible for the operation of all RMUs under this Out sourcing
11 1.1 (iii) The operator should liaise with at command swimming pool sub-station for any major break down/ failure/ shut down for early restoratioin of electric supply.
12 1.11 (iv ) contractor is responsible for arranging technical manpower to rectify the defects inside the sub stn LT panells etc as required at site at the earliest
13 1.12 (v) The contractor is also responsible for the monitoring and operation of street lights in the above areas.
14 2 M&L for preparation of old painted steel surfaces of 11 m long steel poles including removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with 125 mm dia adhesive sticker with white letters/ blackground etc complete all as directed 60 Each
15 3 S & F FRP Loop In Loop Out Boxes copatible to fix MCB with mounting rails,cable connector inclusing provn of suitable GI clamps for fixing to pole,PVC glands of Hansu model HB-14 or equivalent complete all as directed Make: Hensel/Sintex 10 Each
16 4 Earthing complete with galvanised steel earth plate electrode 60 cm × 60 cm × 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32X6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion (Rates inclusive of necessary earth work in any type of soil, PCC pit, CI cover , funnel in watering pipe, 40 mm dia light grade GI protection pipe for earth strip in ground etc, all as required at site for complete earthing.) 6 Each
17 5 M&L for PCC 1:2:4 type B1 using 20 mm graded aggregate for coping of poles and stay including form work , two coats of white wash ,removal old coping , and taking out the broken materils from the site etc complete all as specified and directed. 1 cum
18 6 S & F in repairs Ballast HPSV/MH 400 W all as direted by Engr-in charge\nMake: Havells / Bajaj / Philips / CG 2 Each
19 7 S & F in repairs Ballast HPSV/MH 250 W all as direted by Engr-in charge\nMake: Havells / Bajaj / Philips / CG 3 Each
20 8 S & F in repairs Electornic Igniter for HPSV/MH Lamps 70/150/250/400W all as direted by Engr-in charge. Make: Havells / Bajaj / Philips / CG 3 Each
21 9 S & F in repairs Lamp MH 400 W with theard all as direted by Engr-in charge. Make: Havells / Bajaj / Philips / CG 5 Each
22 10 S & F in repairs Lamp MH 250 W with theard all as direted by Engr-in charge. Make: Havells / Bajaj / Philips / CG 5 Each
23 11 S & F in repairs MCCB 400 A,25 KA 4 pole,415V all as direted by Engr-in charge. Make: GE /L&T//Havells/C&S/Schneider 3 Each
24 12 S & F in repairs MCCB 100 A,16 KA 4 pole,415V all as direted by Engr-in charge. Make: GE /L&T//Havells/C&S/Schneider 4 Each
25 13 S & F in repairs MCCB 250 A,25 KA 4 pole,415V all as direted by Engr-in charge. Make: GE /L&T//Havells/C&S/Schneider 8 Each
26 14 S & F in repairs Digital Ammeter/voltmeter ,415 V all as direted by Engr-in charge. Make: Havells / HPL / L & T / AE / Schneider / BCH 2 Each
27 15 S & F in repairs MCCB 63 A, 16 KA 4 pole,415V all as direted by Engr-in charge. Make: GE /L&T//Havells/C&S/Schneider 3 Each
28 16 S & F in repairs LED phase indicating lamps , all as direted by Engr-in charge 4 Each
29 17 S & F 3 core 1.5 Sq mm multi stranded copper conductor, PVC insulated unshethed cable for connecting junction box to street light fitting complete all as directed. 200 RM
30 18 S&F in repairs single pahse automatic single dial time switch Astronomical type (having longitude and latitude of Indian cities in memory) 250 volt.\n(Make : L&T / Secure / Legrand/ Indo Asian / HPL / Havells)\n 5 Each
31 19 Excavation in trenches n.exc 1.5 m wide and not exc 1.5 m depth and getting out in hard/dense complete all as specified and directed. 112 CUM
32 20 Returning and filling in of excavated material any type including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed. 67 CUM
33 21 Removal of surplus excavated material of any type to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5 m bove the starting point complete all as specified and directed. 45 CUM
34 22 M&L for sand cushioning / sand covering for underground cable protection complete all as specified.\nNote: Punned thickness shall only be measured and paid. 31 CUM
35 23 Supply and laying sub class 'B' bricks of old size (approved size locally available) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge 3480 Each
36 24 Supply,fixing and testing of Street lights LED 90 W with drive, 230 volts or nearest size pressure die cast aluminium housing luminaires with high power LED source ( maintaing minmum system lumen-6000) on 09 mtr/11Mtr poles with IP protection 66 all necessary fixing arrangments and fittings etc including taking out old one of any type complete all as specefied and directed.\nMAKE : ENDURACITYLINERNEOSL90WLED757SASYBOTG of Havells or LSTP-90-CDL of CG or equivalent in Philips / Wipro / GE as approved by GE. 12 Each
37 25 Supplying,fixing and testing of Gate light / post-top light fitting 35W / 40W LED or nearest size ( maintaing minmum system lumen-3500) with die cast aluminium body with drive, 230 volts or nearest size and with spun aluminium landscape luminaire and IP-65 protection with high power LED as source all necessary fixing arrangments and fittings etc including taking out old one of any type complete all as specefied and directed.\nMAKE :CORALPT35WLED757PSYMTOPC of Havells or LPTO-40-CDL of CG or equivalent in Philips / Wipro / GE as approved by GE. 4 Each
38 26 Supply and fix cable jointing kit for 11 KV grade cable for outdoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm.\n Make : Raychem/ Birla 3M / Denson 2 Each
39 27 Supplying,fixing and testing of landscape light for garden and slope areas 10 W LED Integral decorative bollard inverted pyramid tripod with IP-65 protection icluding all necessary fixing arrangments and fittings etc including taking out old one of any type complete all as specefied and directed. \nMAKE :LBLSN-10-CDL of CG or equivalent in Havells/Philips / Wipro / GE as approved by GE. 10 Each
40 28 Supplying,fixing and testing of Flood light die cast aluminium of 120 W, 230 volts or nearest size ( maintaing minmum system lumen-12000 )with IP 66 including drive with all fixing arrangements with nuts&bolts,clamps, iron chanels on poles etc complete all as specified and directed by Engineer-in-Charge including taking out old one complete all as specefied and directed. \nMAKE :JETAIRISFLS120WLED757SYMLTG of Havells or LFLN-120-CDL/60 of CG or equivalent in Philips / Wipro / GE as approved by GE. 4 Each
41 29 Supplying,fixing and testing of Flood light die cast aluminium of 150 W, 230 volts or nearest size ( maintaing minmum system lumen-15000) with IP 66 including drive with all fixing arrangements with nuts&bolts,clamps, iron chanels on poles etc complete all as specified and directed by Engineer-in-Charge including taking out old one complete all as specefied and directed. \nMAKE :JETAIRISFLS150WLED757PSYMLTG of Havells or LFLN-150-CDL/60 of CG or equivalent in Philips / Wipro / GE as approved by GE. 4 Each
42 30 supply and fix heat shirnkable type LT straight joint for Cable 3.5/4 core 25 Sqmm to 50 Sqmm size \nMake : Raychem/ Birla 3M / Denson 1 Each
43 31 supply and fix heat shirnkable type LT straight joint for Cable 3.5/4 core 70 Sqmm- 150 Sqmm size\n Make : Raychem/ Birla 3M / Denson 1 Each
44 32 supply and fix heat shirnkable type LT straight joint for Cable 3.5/4 core 185 Sqmm- 240 Sqmm size\n Make : Raychem/ Birla 3M / Denson 1 Each
45 33 M&L for GI pipe light grade 80 mm dia laid along road crossings / plinth protection with suitable fittings for cable protection or fixed to the pole/ Wall complete all as specified and directed by Engineer-in-Charge .\nMake : Surya Roshni Ltd / Tata / Jindal steel / Prakash 5 RM
46 34 Supply and laying or fixing or passing through pipe or in cable ducts, 11000 volts grade XLPE(FRLS) insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 185 sq mm 3 core size including dismantling old one complete all as specified and directed by Engineer-in-Charge.\nMAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex 120 RM
47 35 Supplying, laying, testing and commissioning LT XLPE FRLS insulated , armoured heavy duty electric cable of size 4 core 16 sq mm , 1100 volts grade with stranded aluminium conductor laid in trenches / passing through pipe / duct/ road crossing /fixed on poles / walls Complete including taking out old one all as specified and directed.\nMAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex\n[Note: The rate quoted shall inclusive of termination at ends with suitable aluminium lugs where required] 100 RM
48 35.01 All as per item no 35.00 above but 25 sqmm 4 core 130 RM
49 35.02 All as per item no 35.00 above but 95 sqmm 4 core 70 RM
50 35.03 All as per item no 35.00 above but 120 sqmm 3.5 core 80 RM
51 35.04 All as per item no 35.00 above but 150 sqmm 3.5 core 80 RM
52 35.05 All as per item no 35.00 above but 185 sqmm 3.5 core 40 RM
53 35.06 All as per item no 35.00 above but 240 sqmm 3.5 core 20 RM
54 35.07 All as per item no 35.00 above but 400 sqmm 3.5 core 40 RM
55 36 M & L For cable jointing kit for 11 KV (Earthed) grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 185 sqmm \n Make : Raychem/ Birla 3M / Denson 2 Each
56 37 Supply and fix cable jointing kit for 11 KV grade cable for indoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 185 sq mm.\n Make : Raychem/ Birla 3M / Denson 4 Each
57 38 Disconnecting defective oudoor/indoor power distribution transformer of 315/400/500/1000 KVA rating from HT/LT and earth conection and taken out from the sub stn / plinth and transporting to workshop taking out complete transformer oil, storing the same in suitable containers (to be provided by contractor) opening top cover and lifting up the core assembly carefully to check the condition of transformer winding core refixing the same after repair refilling the transformer oil after dehydration and filteration (dehydration and filteration to be paid separately) including checking of leakage of transformer body and welding works required for making transformer body leak proof, applying two coats of synthetic enamel paint over the transformer body after preparation of surfaces, tranportation of transformer from work shop to site and reinstalling the same at any site and connecting and testing complete all as directed by Engr-in-Charge. The materials required for rectification of defects such as rewinding/core/transformer oil / bushes etc shall be measured and paid searately. 1 Job
58 39 Supply only the following items for item No 38 here-in-before
59 39.01 HT copper coil made out of proper size of DPC copper wire super enamelled of high quality matching with the existing impedance and insulation of all as specified and as directed by Engr -in-Charge. 255 KG
60 39.02 Reconditioning of LT copper coil after providing necessary insulating material, glass sleeves etc all as directed at site by Engr-in-Charge. 200 KG
61 39.03 HT bush rod made out of copper with brass nuts and washers of required quality and size suitable for 315 KVA to 1000 KVA transformer 3 Each
62 39.04 HT bushing porcelain suitable for for 315 KVA to 1000 KVA transformer complete with gaskets. 4 Each
63 39.05 LT Bush rod suitable for 315 KVA to 1000 KVA transformer with washer complete 4 Each
64 39.06 LT bushing porcelian suitable for for 315 KVA to 1000 KVA transformer complete with gaskets. 4 Each
65 39.07 Supply only synthethetic rubberised cork sheet gasket 1/4" thick suitable for main body of transforemr capacity upto 500 KVA. 1 Each
66 39.08 Silicagel dark blue laboratory grade of good quality 3 KG
67 40 Filteration of transformer oil of transfomers installed at various locations to achieve di-eletric strength not less than 50 KV at 2.5mm gap as per relevant IS with portable filteration plant, testing of the oil for the di-electric strength before filtratin and after filtration complete all as directed by the Engr-in-Charge. 3200 Ltr
68 41 Supply and topping up of transformer oil with di-electric strenght not less than 50 KV in to the conservator tank/ body tank of the transformer at various locations complete all as directed by the Engr-in-Charge. Make: Power Oil/ Transoil/ Sabitha Chemicals/Electrol 260 Ltr
69 42 M&L for preparation of old painted surfaces of transformers with coarse cloth/ brush and painting throughout externally on exposed surfaces with two coats of smoke grey colour synthetic enamel paint including writing of transformer details on plinth in white enamel paint on black enamel paint back ground complete including one coat of white wash for base foundation all as specified anddirected by Engineer-in-Charge for the following capacity in-door/ out-door type transformer:-
70 42.01 150 to 800 KVA 8 Job
71 43 Supply & Fixed in repairs street light luminaire integral type LED fitting of 170 watts output with minimum 85 lumens per watt in aluminium die cast housing with IP 66 protection complete with all accessories incl driver and electronic surge protection device of min 5 KV complete all as specified. MAKE : BRP322 LED 163 CW MR FG S4XTFC L GR of Philips or LSTN-170-CDL-A of CG or ENDURACITYLINER NEOSL170W LED757 PASYBOTG of Havells or equivalent in Wipro / GE as approved by GE. 6 Each
72 44 Supplying , fixing and testing of timer switch 65A 3 pole panel complete for street light controls analog time switch with connected items fixing on pole/wall/panels including PCC with all fixing arrangements complete , taking out old one etc all as directed.\nMake: Havells/ Indoasian/ L&T / Siemens /Hager / Schneider. 2 Each
73 45 Supplying, fixing and testing of URBAN Solar Bollard light LED ffitting of 4W with self powered lighting source and minimum maintenance of low power consumption and user friendly with (a) Solar PV module of, High effiecnecy poly Crystalline solar module and (b) Battery Maintenance free Lithium battery with expected life of 1000 cycles and back up for 2 days (c) LED High efficiency long life LED (d) PIR sensor control the dimming and brightness with range upto 3-4 Meter (e) Housing Elegant looking Die cast Aluminimum body +PC with IP65 protection (f) Warrenty 1 year \nMake : Cat No. LHKNAWPFFN65K001 of Havells or equivalent in Philips/Bajaj as approved by GE. 10 Each
74 46 M&L Earthing Electrode 300 mm length copper coated, 100 microns thickness as per UL standard approved and testing by CPRI, pipe in pipe type inner pipe dia 41.9(min)mm, outer dia 76/80(min)mm annular space filled with high conductivity and anti corrosive compound with connection terminal. M&L infill compound (Chemical) 50Kgs ( 2 Bag each 25 Kgs) Elecrodite/ Humedites constituting natural element not water dissoble reduce soil resistivity highly hygroscopic and swells high conuctivity and anti corrosive retains moisture for a long time . M&L Earth work Vertical excavation in normal soil upto a depth of 3000mm the diameter of the bore hole being minimum 250 mm . installation filling the bottom 4" of the bore with infill compound ( Chemical) vertically placing the electrode in the centre of the pit ,fill the cavity around the electrode with the chemical ensuring there are no air gaps in the chemical filled cavity region make a thick paste by pouring water into the earth pit and mixing the mixture with a pole. complete as directed. including PCC earth Pit and RCC Pit cover complete 5 Each
75 47 M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as 32x6mm copper strip complete as directed 50 RM
76 48 S&F Air circuit breaker 4 pole 415 V with thermal magnetic release( manual fixed type) of capacity 800 Amps necessary modification in LT panel necessary fixture and fitting necessary tools and plants etc including taking out defective ACB removing of electrical and mechanical connection complete all as specified and directed \nMake :ABB/Seimens/Schneider 1 Each
77 49 Supply and fix lighting arrester HT 11 KV 10 KA station class all as per specified and directed by Engr in charge Make : Jaipuria 1 Set of 3
78 50 Supply & replacement, calibrating, testing, commissioning of Micro processor feeder protection relay, range - 0.01In – 8In, protection setting- 2 set, protecting circuit correct – 1Amps & 5Amps sets, records history- 5Nos, Min 6 Analog out put, with following protections feeder protection 50/ 51N (3 Phase current), 50/ 51N (Earth Over current), 67 P (3 Phase directional Over current), 6/N (Earth fault directional over current), 51V (Voltage controlled over current) 37 (3 phase under current), 46(Negative phase sequence over current), 59N (Residual over voltage), 49 (Thermal over load), 79(Auto reclose), 50BF( Circuit breaker failure detection), Cold Load pickup, Inrush blocking, Relay will be on MODBUS protocol with LCD display, trip, circuit healthy, alarm, other assignable indication,Auxlary suppy : 110V DC. 2 EACH
79 51 S & Fixed in repairs On load auto transfer switch 630 A, 4pole ,415V including control unit all as directed by Engr-in-charge.\nMake : Havells / Indo asian/L&T 1 Each
Disclaimer :