Repair / Maintenance Of Street Light , High Mast Light And Solar Light At Dronachal Bhopal, GE Dronachal-Madhya Pradesh

Military Engineer Services-MES has published Repair / Maintenance Of Street Light , High Mast Light And Solar Light At Dronachal Bhopal. Submission Date for this Tender is 07-08-2020. Coats and Jackets Tenders in GE Dronachal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

24741959
Corrigendum : Repair / Maintenance Of Street Light , High Mast Light And Solar Light At Dronachal Bhopal
Open Tender
Indian
Madhya Pradesh
GE Dronachal
07-08-2020

Tender Details

Repair / Maintenance Of Street Light , High Mast Light And Solar Light At Dronachal Bhopal , Taking Down And Dismantling Of Street Light Fittings Of Any Type Size And Model ( Ftl , Es , Hpsv , Mvl , Mh , Floodlight Fittings , Solar Light , ) , Removing Of Unserviceable Spares / Accessories For Repair / Replacement Of The Same Including Refixing Of Street Light Fittings Of Any Size , Type And Model On Gi Tubing Bracket To Existing Pole Of Any Type And Any Size ( Like Single / Double Swan Neck , Straight , Pcc / Steel Tubular Poles Of 9 / 11 Mts Height ) And Testing Complete All As Directed . Note : ( Spare / Parts Required For Repairing Of Fitting Will Be Issued / Paid Under Respective Items Of This Schedule ) , Taking Down , Dismantling And Necessary Repairing Of Led Street Light Fittings To Make Functional By Replacing Unserviceable Part Such As Pcb , Lens , Holder , Insulation Pad , Heatsink , Wire Connecting Terminal Etc As Existing Including Refixing Of Led Street Light Fittings Of Any Size , Type And Model On Gi Tubing Bracket To Existing Pole Of Any Type And Any Size ( Like Single / Double Swan Neck , Straight , Pcc / Steel Tubular Poles Of 9 / 11 Mts Height ) Including Supply And Fixing Of Pvc Sheathed Aluminium Conductor Mutistranded Cable Of 2 Single Core Of 2 . 5 Sqmm Of Min Length 8 Metre From Fitting To Electric Supply Source And Testing Complete All As Directed . , M&L For Taking Down Mh Light Fittings Mounting On Cage From High Mast Pole Of 12 . 5 / 16 / 20 Mtrs Height For Repairing Of Mh Light Fitting Of Any Size / Type And Reinstalling The Fitting / Cage Back To Its Position After Carrying Out Repairs All As Directed By Eic ( Cost Of Choke , Bulb , Igniter Will Be Measure Seprately ) , S&F In Repair Mh Lamp Only Single Ended Clear Tubular To Be Fixed In Mh / High Mast Light Fitting All As Directed By Eic . Make :- Havells / Philips / Cg / Wipro / Halonex / Bajaj , ( A ) 400 Watt , ( B ) 250 Watt , ( C ) 150 Watt , S&F In Repair For Open Constructed Copper Ballast For Mh Lamp 400 Watt Suitable For Hpsv / Mh / High Mast Fittings All As Specified And Directed . , Supply And Fixing In Repair Copper Wound Open Constructed Ballast Suitable For Hpsv / Mh Light Fitting 250 Watts ( In Repairs ) , 240V All As Specified And Directed . , Supply And Fixing In Repair Copper Wound Open Constructed Ballast Suitable For Hpsv / Mh Light Fitting 150 Watts ( In Repairs ) , 240V All As Specified And Directed . , S&F In Repair Ignitor ( Super Imposed Pluse Ignitor ) Suitable 70 To 400 W For Mh Lamp All As Specified And Directed . , Supply In Repairs Lamp Holder For Lamp Base E-27 Suitable For 70 / / 150 / 250 Hpsv / Mh Luminaries . , Supply In Repairs Capacitor 10 Mfd , 250 V For 70 Watt Hpsv / Mh Luminaries . , Supply In Repairs Capacitor 20 Mfd , 250 V For 150 Watt Hpsv / Mh Luminaries . , Supply In Repairs Capacitor 33 Mfd , 250V For 250 Watt Hpsv / Mh Luminaries . , Excavation In Trenches Not Exceeding 1 . 5M Wide And Not Exceeding 1 . 5 M In Depth For Laying Of Caste And Getting Out In Hard / Dense Soil Disintegrated Rock . , Returning , Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc 25 Cm In Soft / Hard Dense Soil , Removing Excavated Material Not Exc 50 Mtr And Depositing Where Directed At Level Not Exc 1 . 5 M Above The Starting Point Complete All As Specified And Directed , M&L For Clean , Dry , Unwashed Sand Filled In Trenches For Cushioning To Cable Complete All As Specified And As Directed At Site . Note:- The Depth Of Cushion After Punning Shall Be Measured . , Supply And Laying Burnt Brick Sub Class B Modular Size , For Cable Protection Laid Length Wise Perpendicular To The Axis Of Cable Complete All As Specified And Directed . , Taking Out Old Unserviceable Lt Under Ground Cable Of Any Size And Rating . , Supply And Laying In Repair Pvc Insulated Armoured Heavy Duty Electric Under Ground Cable Aluminum Conductor 1100 Volts Grade In Trenches / On Pole Through Sleeves Etc . Of 10 Sqmm 4 Core Complete All As Specified And Directed , M&L Cutting Pcc / Floor / Road And Taking Out Cable And Making Good , Including Material As Per Existing After Laying Of Pipe For Cable Protection All As Specified And Directed Size Of Trench Not More Than 0 . 30 X 0 . 30 Cm . , S&F In Replacement Of Gi Pipe Medium Grade On Road / Pole / Wall / Floor For Cable Protection With Fixing Arrangement Size 50Mm Dia . , M&L For Plain Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate For Coping Around Poles , Including Necessary Form Work Finishing Even And Smooth Without Using Extra Cement , All As Specified And Directed . , M&L For Scratching Out Old Bubbled Paint , Finishing The Surface With One Coat Of Primer ( Red Oxide ) & Two Coats Of Aluminium Paint Of 1St Quality To Street Light Steel Tubuler Poles Of Any Height 7 / 9 Mtr , Any Type ( Double Swan , Single Swan ) All As Per Site Including Two Strips Of 30 Cm Wide To Be Painted Red Synthetic Enamele Above Embedded Level , Including Pole Number Writting With White Colour Enamel Paint On Black Colour Circular Base ) With Two Coat Of Lime Wash On Pole Coping All As Directed By Engr-In-Charge . , Supply & Fixing Factory Made Ip-65 ( Dust And Power Jet Proof According To Iec 60529 ) Opaque Street Light Junction Box Of Size 200 Mm X 160 Mmx98 Mm Made Of High Quality Polycarbonate ( Shock Proof , Rust Free , Corrosion Free Acid And Chemical Resistant , Fire Retardant Having High Impact ( Ik 08 ) Totally Insulated Made Of Halogen And Silica Free Recyclable Material , Uv Resistant Having High Grade Gasket Made Of Polyurethane With Copper Terminal , Mcb Sp 6 Amps Rating 10 Ka With Locking Arrangement And 2 Nos M40 Size Cable Gland And One M32 Size Gland Suitable Up To 16 Sqmm Cable Etc Complete All As Specified And Directed . Make: Hensel Cat No K-9255 Or Equivalent In Sintex . , M & L For Repair Of Solar Lights Likes Battery Boxes , Frame Etc . Including Replacing Of Following Accessories Complete All As Specified And Directed , Cfl 9 Watt ( Pin Type ) , Cfl 11 Watt ( Pin Type ) , Charge Controllar , Pcb , Distil Water For Battery , Battery 12 V 100 Ah Complete , Supplying And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Conductor , Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed Wire , One Twin Core Cable Flat 6 Sqmm Complete All As Specified And Directed , S&F In Repair Of Automatic Street Light Switch Three Phase With Nature Switch-03 ( Dual Output ) As The Controlling Unit For Automatic Switching Of Street Lights Based On Lux Level Of Natural Light . The Sensor ( Nature Switch ) Along With Suitable Power Contractor , Mcb And Support Terminals Should Be Enclosed In Pole / Wall Mountable Enclosure Made Of Rust Proof , Electric Shock Proof , Termite Proof And Fr Grade Special Moulding Compound ( Sintex Make Smc Junction Box ) Confirming To Ip54 . The Contractor , Mcb And Circuit Wiring Should Suitable Enough To Take Load 5 Kw Equally Distributed Over 3 Phase ( 4 Kw / Phase ) . The Contractor Rating 25 Amps ( 4-Pole ) And Mcb ( Single Pole ) Rating : 20-25 Amps ( Sp-03 Nos ) , Complete All As Specified And Directed . , Taking Down Defective Led Driver And Supply And Fix Led Driver 240 Volts 50 Hz Suitable For 72 W Led Street Light Fitting Including Testing Complete , Taking Down Defective Led Driver And Supply And Fix Led Driver 240 Volts 50 Hz Suitable For 60 W Led Street Light Fitting Including Testing Complete , Taking Down Defective Led Driver And Supply And Fix Led Driver 240 Volts 50 Hz Suitable For 150 W Led Street Light Fitting Including Testing Complete , Taking Down Defective Led Driver And Supply And Fix

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Jul-2020 Corrigendum No 1 BOQ 20-07-2020
2 20-Jul-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-07-2020
3 27-Jul-2020 Corrigendum No 3 Date 07-08-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value