Chandigarh Administration Engineering Department has published Maintenance Of Electrical Installation In Govt . Residential/ Non Residential Building At Chandigarh . ( Repair And Rewinding Of Exhaust Fan , Air Circulator Fan And Ceiling Fan Under The Jurisdiction Of Sde E-9 , Chandigarh .. Submission Date for this Tender is 07-07-2020. Electrical Maintenance Tenders in Chandigarh Chandigarh. Bidders can get complete Tender details and download the document.
Name of Work: Mtc of E.I. in Govt. residential/ non residential building at Chandigarh. (Repair and rewinding of exhaust fan, air circulator fan and ceiling fan under the jurisdiction of SDE E-9, Chandigarh | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Full stator rewinding of Exhaust fan (condenser type) of 900/ 1400 RPM including cleaning and insulating the stator slots, sleeving soldering wrapping of cotton tape, varnishing re-assembling and testing etc. complete. | |||
2 | 1.01 | Exhaust fan 12” | NSR | 65 | Nos. |
3 | 1.02 | Exhaust fan 15” | NSR1 | 35 | Nos. |
4 | 2 | Replacement of ball bearing of ceiling fan including greasing, re-assembling and testing etc | NSR2 | 240 | Nos. |
5 | 3 | Full stator rewinding of ceiling fan (condenser type) of 1400 mm sweep including cleaning and insulating the stator slots, sleeving, soldering, wrapping of cotton tape, reassembling, varnishing and testing etc. complete. | NSR3 | 350 | Nos. |
6 | 4 | Supply and erection of fan condenser (paper condenser) for ceiling fan of following rating: The condenser is to be installed in existing ceiling fan after dismantling the defective condenser including connection and testing etc. | |||
7 | 4.01 | Condenser 3.15 µ fd. | NSR4 | 450 | Nos. |
8 | 5 | Providing split pin, check nuts hanger nuts and bolts etc including hanger if required to be replaced after removing the old. The rates includes ceiling fan erection after repair and other petty material such as screws pin, bolt nuts etc. as requirement at site. | NSR5 | 110 | Nos. |
9 | 6 | Fabrication of shaft after removing the shaft from the stator body safely and then labour workshop for welding original shape and other petty material required to complete the job. | NSR6 | 160 | Nos. |
10 | 7 | Painting of ceiling fan complete with blades, canopy, suspension rod, and speed regulator (with stove enameled paint). | NSR7 | 100 | Nos. |
11 | 8 | Spray painting of steel shutter and other out door type pedestal etc. The steel shutter/ rusted outer cover of switchgear etc. in pedestal shall be given anti-rust/ grease treatment and then spray painted with one coat of primer and 2 coats of superior quality of grey paint as approved by Engineer-Incharge of work. | NSR8 | 5500 | sq.ft. |
12 | 9 | Painting of cement collar/ cantilever poles with two coats of snowcem and junction box of superior quality to give good look. This also includes necessary repair to the broken cement collar with cement sand mixture. | NSR9 | 105 | Nos. |
13 | 10 | Painting of street light MS poles 9/ 7.5 mtr. Long as existing at site. The painting job should be done after preparation of surface with the application of sand paper etc and then the pole should be painted with al. paint of superior quality in two coats. The job including for all type of labour, material, paint and T&P as required at site to complete the job. | NSR10 | 75 | Nos. |
14 | 11 | Painting of street light MS poles 4.5 mtr. Long as existing at site. The painting job should be done after preparation of surface with the application of sand paper etc and then the pole should be painted with al. paint of superior quality in two coats. The job including for all type of labour, material, paint and T&P as required at site to complete the job. | NSR11 | 70 | Nos. |
15 | 12 | Painting of jn. Box and outside cover with superior quality of red paint after removing existing rusted paint/ rust etc properly. The cement collar shall be repaired first with cement/ sand plastering compound etc with water up to two days painted with 2 coats of white snowcem of superior quality to make even surface and finished properly. | NSR12 | 180 | Nos. |
16 | 13 | Repair of existing cement collar jn. Box with cement sand mixture. The job includes replacement of existing burnt out jn. Box with new MS box of size 10x12x4 complete with 4 nos. neutral ling complete and other petty material required to complete the job to the entire satisfaction of EIC. | NSR13 | 50 | Nos. |