}

Repair And Maintenance Of Irp Softning Plant Ro Plant And Equipments In Water Supply Installation And Dg Sets Apfc Panels And Other Connected Works In Kolkata Area Under Ge North Kolkata, KOLKATA AREA-West Bengal

Military Engineer Services-MES has published Repair And Maintenance Of Irp Softning Plant Ro Plant And Equipments In Water Supply Installation And Dg Sets Apfc Panels And Other Connected Works In Kolkata Area Under Ge North Kolkata. Submission Date for this Tender is 21-07-2020. Rough Finishing Tools Tenders in KOLKATA AREA West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

24676223
Corrigendum : Repair And Maintenance Of Irp Softning Plant Ro Plant And Equipments In Water Supply Installation And Dg Sets Apfc Panels And Other Connected Works In Kolkata Area Under Ge North Kolkata
Open Tender
Indian
West Bengal
KOLKATA AREA
21-07-2020

Tender Details

Repair And Maintenance Of Irp Softning Plant Ro Plant And Equipments In Water Supply Installation And Dg Sets Apfc Panels And Other Connected Works In Kolkata Area Under Ge North Kolkata-1 Opening Top Cover Of Manhole And Side Hand Hole Of 10000 Gph Capacity Vertical Type Iron Removal Plant And Unloading The Filter Media Eg. Sand, Gravells ( Different Sizes ) And Taking Out Carefully Strainer ( Push / Thread ) From Inside Bed Plate And Disposal Of Unsv Filter Media ( Sand, Gravel, Strainer Etc ) Within 100 Mtrs Radius From The Existing Plant Complete All As Directed. ( Location : Salt Lake, Bagjola & Dakshineswa ) 2 Opening Top Cover Of Manhole And Side Hand Hole Of 10000 Gph Capacity Vertical Type Softening Plant, Unloading The Filter Media Eg. Rasin, Sand, Gravells ( Different Sizes ) And Taking Out Carefully Strainer ( Push / Thread ) From Inside Bed Plate And Disposal Of Unsv Filter Media ( Sand, Gravel, Strainer Etc ) Within 100 Mtrs Radius From The Existing Plant And Keeping Safe Custody Of Serviceable Resin For Reuse Complete All As Directed. ( Location : Salt Lake, Bagjola & Dakshineswar ) 3 Dismalting Cover, Pipe Lines By Taking Out / Cutting The Old Rusted Ms Bolt Nuts And Washers, Neoprene Rubber Gasket Etc Of Oxidation Chamber, Taking Out Manganese Dioxide ( Mno2 ) And Removing The Same Within 100M Radius From The Existing Plant, Andcleaning, Scrapping The Inner Periphery And External Old Rusted Iron Surfaces Of Oxidation Chamber, Flushing With Fresh Water Drying And Applying Two Coats Of Anti Corrosive Black Bituminous Paint Over A Coat Of Red Oxide Primer Suitable For Potable Water, In Inner Periphery And Painting With Two Coats Of Synthetic Paint Over A Coat Of Red Oxide Primer, On Outer Surface Including Writing Of Type Of Installation In White Colour And Mes No In Dark Red Colour. Make Of Paint:- Asian / Berger / Jenson & Nicholson / Shalimar. 4 Cleaning And Scraping The Inner Periphery And Outer Surfacse Of Irp / Softening Plant Vessel By Using Wire Brush And Flushing With Fresh Water, Drying And Applying Two Coats Of Anticorrrosive Bituminous Paint Over A Coat Of Red Oxide Primer Used In Potable Water In Inner Periphery And Painting With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer On Outer Surface Including Writing Of Type Of Installation & Capcity By Sythetic Enamel Paint Of White Colour And Mes No In Dark Red Colour All As Directed. Make Of Paint:- Asian / Berger / Jenson & Nicholson / Shalimar. 5 Supply And Fix New Polypropylene Strainers Double Deck Type For Irp Vessel Etc Complete Make- Ion Exchange / Mei / Rmco 6 Supply And Fix New Polypropylene Strainers Double Deck Type For Water Softening Plant As Per The Existing Specification. Make- Ion Exchange / Mei / Rmco 7 Supply And Loading The New Graded Gravells Of Different Size ( Gravel Of Size 1.5 X 1, Pebbles Of Size 1X1 / 2, Core Silex Of Size 1 / 2 X 1 / 4 , Fine Silex Of Size 1 / 4 X 1 / 8 ) Equally Distributed Inside The Pressure Filters At Different Location. 8 Supply & Charging Of New Filter Sand Of 10 X40 Mesh From Baraker, Laying Layer By Layer As Per Designed Layer To The Pressure Filters At Different Location Complete All As Specified And As Directed 9 Supply And Loading New Resin Indian 225 Na Type In The Softening Plant All As Specified And Directed. ( Make : Ion Exchange Or Equivalent As Approved ) . ( Location : Salt Lake, Bagjola & Dakshineswar ) 10 Laying / Filling Resin In The Vessel Of Softening Plant And All As Specified And Directed. ( Note : Old Serviceable Cation Resin Obtained From Item No 02 Shall Be Reused After Cleaning, Washing Usinng Hydrogen Chloride Solution Of Desired Strength And Fresh Water All As Directed. ( Location : Salt Lake, Bagjola & Dakshineswar ) 11 Supply And Loading Mno2 In The Existing Oxidation Chamber Plant Complete All As Specified And As Directed. ( Location : Salt Lake, Bagjola & Dakshineswar ) 12 Material & Labour For Nylon Wire Mesh Including Tightening By Copper Wire As Reuired Size On Irp / Softening Plant Of 10, 000 Gph Inside Including Taking Out Old Damaged Wire Mesh 13 Dismalting Of Exiting Ms / Ci Pipe And Fitting Of 100 Mm Bore By Opening Flange Joint Cleaning And Removing Silt, Rust By Using Wire Brush And Flushing With Clean Water For Both Inside & Out Side Of Pipes And Fittings, Painting The Outside Surface Of Pipe & Fittings With Two Coats Of Synthetic Enamel Paint Over A Coat Of Primer And Re-Fixing In Exiting Position Complete. Note : New Bolts, Nuts & Washers Shall Be Measured And Paid Separately Under Supply Only Rate.The Labour Element Required For Fixing Nut, Bolts & Washers Is Deemed To Be Included In The Unit Rate Quoted. ) 14 Dismalting Of Exiting 80 Mm Bore Ms / Ci Pipe & Fitting By Opening The Flange Joints, Cleaning And Removing Silt, Rust By Using Wire Brush And Flushing With Clean Water For Both Inside & Outside Of Pipes And Fittings, Painting The Outside Surface Of Pipe & Fittings With Two Coats Of Synthetic Enamel Paint Over A Coat Of Primer And Re-Fixing In Exiting Position Note : New Bolts, Nuts & Washers Shall Be Measured And Paid Separately Under Supply Only Rate ) . The Labour Element Required For Fixing Nut, Bolts & Washers Is Deemed To Be Included In The Unit Rate Quoted. ) 15 Dismalting Of Exiting 50 Mm Bore Ms Pipe & Fitting Carefully By Opening The Flange Joints, Cleaning And Removing Silt, Rust By Using Wire Brush And Flushing With Clean Water For Both Inside & Outside Of Pipes And Fittings, Painting The Outside Surface Of Pipe & Fittings With Two Coats Of Synthetic Enamel Paint Over A Coat Of Primer And Re-Fixing In Exiting Position Note : New Bolts, Nuts & Washers Shall Be Measured And Paid Separately Under Supply Only Rate.The Labour Element Required For Fixing Nut, Bolts & Washers Is Deemed To Be Included In The Unit Rate Quoted. ) 16 Dismantling Of Existing 40 Mm Bore Ms Pipe & Fitting By Opening The Flange Joints, Cleaning And Removing Silt, Rust By Using Wire Brush And Flushing With Clean Water For Both Inside & Outside Of Pipes And Fittings, Painting The Outside Surface Of Pipe & Fittings With Two Coats Of Synthetic Enamel Paint Over A Coat Of Primer And Re-Fixing In Exiting Position Complete All As Specified And As Directed ( Note : New Bolts, Nuts & Washers Shall Be Measured And Paid Separately Under Supply Only Rate.The Labour Element Required For Fixing Nut, Bolts & Washers Is Deemed To Be Included In The Unit Rate Quoted. 17 Taking Out & Re-Fixing After Servicing Of Ci Diaphram Valve 100 Mm Dia By Using Wire Brush Emery Cloth Paper. Hcl Acid And Flushing With Fresh Water Both Side Reassembling & Painting The The Outer Surface & Wheel With Two Coats Of Synthetic Enamel Paint All As Specified And Directed. ( Note : New Bolts, Nuts & Washers Shall Be Measured And Paid Separately Under Supply Only Rate. The Labour Element Required For Fixing Nut, Bolts & Washers Is Deemed To Be Included In The Unit Rate Quoted. ) 18 All As Per Item No 17 Here-In-Before But For Valve Of Size 50 Mm Dia. 19 All As Per Item No 17 Here-In-Before But For Valve Of Size 40 Mm Dia. 20 Supply & Fix Ci Diaphragm Valve 100 Mm Dia Both End Flanged Including Taking Down Old Valve Complete All As Specified And As Directed. ( Make : Upadhyay / Super / Hazra ) . ( Note : New Bolts, Nuts, Washers & Gasket Shall Be Measured And Paid Separately Under Supply Only Rate.The Labour Element Required For Fixing Nut, Bolts & Washers Is Deemed To Be Included In The Unit Rate Quoted. 21 All As Per Item No 20 Above But For Valve Of Size 50 Mm Dia. 22 All As Per Item No 20 Above But For Valve Of Size 40 Mm Dia. 23 Taking Out & Re-Fixing After Servicing Of Butterfly Valve Of Size 100 Mm Dia By Using Wire Brush Emery Cloth Paper, Hcl Acid And Flushing Out Fresh Water, Painting The The Outer Surface Handle With Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Complete All As Specified And As Directed. ( Note : Nuts Along With Bolts, Washers And Gasket Shall Be Measured And Paid Separately Under Supply Only Rate.The Labour Element Required For Fixing Nut, Bolts & Washers Is Deemed To Be Included In The Unit Rate Quoted. 24 Supply & Fix Butterfly Valve Of Size 100 Mm Dia Conforming To Is 13095 Both End Flanged Including Taking Down Old Valve Complete All As Specified And As Directed. Make : Kalpna / Upadhya / Crawley & Ray / Zoloto 25 Supply & Fix Pvc 15 Mm Bore Bib Tap Of Ptmt Including Taking Out Old Bib Tap Complete All As Specified And As Directed. Make - Prayag / Polytuf / M / S Sak Plast Pvt Ltd. 26 Supply & Fix Gun Metal Horizontal Check Valve 20 Mm Dia Including Taking Out Old Check Valve Complete All As Specified And As Directed. Make : Laxmi / Upadhya / Alto / Hm / Zoloto 27 Supply Only Ms Bolts, Nuts & Washers Of Different Sizes Suitable For Ci / Ms Flanged Pipe & Sluice Valve Etc. Male:- Gkw / Mahendra / Any Other Reputed Make As Approved By The Ge. 28 Supply Only Neoprene Rubber Gasket For Man Hole And Side Hole Cover Of Irp / Softening Plant / Oxidation Chamber Complete All As Specified And As Directed. 29 Material & Labour For Cleaning And Removing All Scale And Dirt, Etc, From Salt Mixing Pvc Tanks Exe 500 Ltrs But Not Exc 1000 Ltrs And From Mouths Of Circulating Pipes, Etc Complete All As Specified & Directed 30 Material And Labour For Drilling On 100 Mm Dia Ms / Ci Or Gi Pipe For Fixing Of Pressure Gauge, Sampling Cock, Brass Cock, Gun Metal Bush & Gi Socket Etc Incl Welding Work Complete All As Specified & Directed 31 Material & Labour For Arrow Marking Indicating Flow Of Water Direction By White Paint Of Size Length 8 And Breath 1 On Pipe Line Of Irp / Softening Plant, Oxidation Chamber Rising Main, Delivery Line & Wash Out Line Etc Including Writing Of Smno / Mes No All As Directed. Make Of Paint:- Asian / Berger / Jenson & Nicholson / Shalimar. 32 Preiodic Cleaning / Servicing Of Ro Plant Of Capacity 800Lph By Dismantaling Of The Iron Filter / Bag Filter / Candle Filter, Ro Membrane, Storage Tank, Flow Metre, Connected Pipe Lines Etc And Proper Cleaning And Assembling And Making Fit For Use As Well As Control Tds With In Prescribed Limit All As Directed. Note: ( I ) Location: 2 Cbpo. ( Ii ) Any Break Down Occurs To Plants During The Qtr ( Within 03 Months Of Servicing ) To Be Rectified By Contractor With Out Any Extra Cost. ( Iii ) Change Of Any Spare Parts And Requirement Of Chemical For Cleaning Should Be Measured And Paid Saperately Under Supply Only Rates.The Labour Element Required For Fixing Nut, Bolts & Washers Is Deemed To Be Included In The Unit Rate Quoted. . 33 All As Per Sl Item No:32 Above But For Capacity 600 / 500 / 250 Lph. Note:Location: Iwt Dakshineswar-02 Nos & Salt Lake-02 Nos. 34 Supply Only Mechanical Seal Of High Pressure Pump Of R O Plant Of Capacity 800 / 600 / 500 / 250 Lph 35 Repair And Servicing Of High Pressure Pump Of Ro Plant Of Capacity 800 Lph 36 Repair And Servicing Of High Pressure Pump Of Ro Plant Of Capacity 600 Lph 37 Repair And Servicing Of High Pressure Pump Of Ro Plant Of Capacity 500 Lph 38 Repair And Servicing Of High Pressure Pump Of Ro Plant Of Capacity 250 Lph 39 Repair And Servicing Of High Pressure Membrane Cleaning Pump Of Ro Plant Of Capacity250 Lph 40 Repair And Servicing Of Membrane Cleaning Pump Of Ro Plant Of Capacity 600 / 500Lph 41 Cleaning Of Sand & Activated Carbon Filter By Taking Out Old Media And Charging With New One As Per Existing Ratio For Ro Plant Of Capacity 800Lph 42 Supply Only Iron Filter For Ro Plant Of Existing Make And Of Capacity 600 / 500 & 800 Lph 43 Supply Only O-Ring Of Any Size Nut Bolt Washers , Pvc Pipes, Flexible Pipes Etc Parts And Allied Consumable Items As Required During Each Serviceing Or Ro Plant Of Capacity 800 / 600 / 500Lph 44 Supply Only Cf As Per Existing Make For Ro Plant Of Capacity 800Lph 45 Supply Only Cf As Per Existing Make For Ro Plant Of Capacity 600Lph 46 Supply Only Cfas Per Existing Make For Ro Plant Of Capacity 500Lph 47 Supply Only Cfas Per Existing Make For Ro Plant Of Capacity 250Lph 48 Supply Only Of Cartriage Cover / Housing For Ro Plant Of Of Capacity 800 Lph 49 Supply Only Of Cartriage Cover / Housing For Ro Plant Of Of Capacity 600 Lph 50 Supply Only Of Cartriage Cover / Housing For Ro Plant Of Of Capacity 500 Lph 51 Supply Only Of Cartriage Cover / Housing For Ro Plant Of Of Capacity 250 Lph 52 Supply Only Ultra Violet Ray Lamp Suitable For Ro Plant Of Capacity 800 / 600 / 500 / 250 Lph Make: Philips / Bajaj 53 Supply Only Chemical ( Aquaclean Cvd ) For Cleaning For Membrane Of Ro Plant Of Capacity. 54 Supply And Fix In R O Plant Tds Meter As Per Existing Model And Make Including Taking Out Old Meter All As Directed 55 Supply And Fixing Tds Sensor As Per Existing Model And Make Including Taking Out Old Unserviceable Sensor Of Ro Plant Of Capacity 250 / 500 Lph 56 Supply Only Floaty As Per Existing Model And Make Of Ro Plant Of Capacity 800 / 500 Lph 57 Material And Labour For Re-Winding Of Motor Capacity 1Hp Centrifugal Pump Set With Same Gauge As Per Existing And Same Number Of Turns Of Super Enamelled Solid Copper Conductor Including Providing Core Insulation, Heat Varnishing, Testing Complete All As Specified And As Directed. 58 Material And Labour For Re-Winding Of Motor Of High Pressure Pump Set With Same Gauge As Per Existing And Same Number Of Turns Of Super Enamelled Solid Copper Conductor Including Providing Core Insulation, Heat Varnishing, Testing Complete All As Specified And As Directed. 59 Supply And Fixing Ro Plant Membrane Of Hydranotix / Dow In Replacemnet Of Unserviceable Membrane Of Ro Plant Of Capacity 800 Lph 60 Supply And Fixing Ro Plant Membrane Hydranotix / Dowin Replacemnet Of Unserviceable Membrane Of Ro Plant Of Capacity 600 Lph 61 Supply And Fixing Ro Plant Membrane Hydranotix / Dow In Replacemnet Of Unserviceable Membrane Of Ro Plant Of Capacity 500 Lph 62 Supply And Fixing Ro Plant Membrane Hydranotix / Dow In Replacemnet Of Unserviceable Membrane Of Ro Plant Of Capacity 250 Lph 63 Dismantling / Opening Of Air Compressor Of Suitable Capacity As Per Site With Replacement Of Minor Parts Like Piston With Ring Set, Air Pressure Leaf, Piston Packing Set, Air Pressure Meter, Air Block Lock, V-Belt Of Type C-90 ( Make- Fenner ) And Nut-Bolts, Washers, Flexible Pipe & Reassembling, Testing, Connection And Commissioning Complete All As Specified And As Directed By Engr-In-Charge. 64 Taking Down And Dismantling Of All The Component From Engine Assemble For Carring Out Servicing / Overhauling Of Dg Sets By Complete Dismantling Of Disel Engine Segregating Serviceable And Semi / Unserviceable Parts, Decarbonisation, Cleaning Thoroughly All Interior & Exeterior Parts After Disconnecting The Out-Going Connection Of Diesel Engine From The Panel Board, Repair / Replacement Of Defective Spares And Servicing Of All Parts Which Ever Is Necessary & Reassembling The Dg Set After Completion Of Work Complete All As Directed By Engineer In Charge For The Dg Set Of Capacity 30 To 50 Kva. Note: ( A ) Work Shall Be Carried Out Through Authorised Service Engineer Of The Dg Set / Oem. ( Ii ) Spare Parts Shall Be Measured And Paid Separately Under Relavant Items As Supply Only The Labour Element Involved For Replaceing Spares Is Deemed To Include In The Unit Rate Quoted. ( Iii ) The Unit Rate Quoted Is Deemed To Include For Minor Spares Not Included Here-In- After. 65 All As Per Item No. 1 Above But, Above But For Dg Set Of Capacity 160 To 250 Kva. 66 Dismentling The Fuel Injection Pump ( Fip ) Segragating Serviceable And Semi / Unserviceable Parts, Replace All Unserviceable Parts And Cleaning Serviceable Parts, Drying, Lubricating, Reassembling The Fip Pump With Cleaned Serviceable Parts Along With New Parts As Per Requirment, Calibration And Testing On Completion Complete All As Directed By Engr-In- Charge For Dg Sets Of Capacity 30 To 50 Kva Complete All As Specified And As Directed. 67 Ditto All As Above But For Dg Set Of Capacity 160 To 200 Kva. 68 Dismantling Of Self Starter Assembly For Complete Overhauling Of Self Starter Including Replacement Of Carbon, Armature Coil, Field Coil, Bush And Bendix Pinion And Other Related Components Of Dg Set Of Capacities 30 To 50 Kva All As Directed. Note: Spare Parts Shall Be Measured And Paid Separately Under Seperate Items As Supply Only The Labour Element Involved For Replacing Spares Is Deened To Include In The Unit Rate Quoted. . 69 Ditto All As Above But For Dg Set Of Capacity 160 To 250 Kva. 70 Dismantling Of Dynamo For Repair And Overhauling Including Replacement Of Armature Coil, Carbon Set, Field Coil, Clutch Patti, Bearing Etc And Other Related Items As Required And Re-Fixing The Same On Mountings And Testing Complete For Dg Set Of Capacities 30 To 50 Kva All As Directed. Dg Sets : Note: Spare Parts Shall Be Measured And Paid Separately Under Seperate Items As Supply Only The Labour Element Involved For Replaceing Spares Is Deened To Include In The Unit Rate Quoted. . 71 Ditto All As Above But For Dg Set Of Capacity 160 To 250 Kva. 72 Dismantling The Radiator Assembly For Cleaning Completely And Overhauling And Repairing Of Radiator Body / Tube Including Its Fan Assembly By Cleaning, Welding, Brazing Etc ( Each Leak Repair Work Shall Be Considered As Single Job ) For Diesel Engine Capacity 30 To 50 Kva Complete All As Specified And Directed By Engineer-In-Charge. 73 Ditto All As Above But For Dg Set Of Capacity 160 To 250 Kva. 74 Supply And Top Up The Coolant K Cool Super Plus-25 / 75 Complete All As Specified And As Directed. Make: Castrol / Servo. 75 Supply And Changing The Engine Oil Of Suitable Grade Including Drain Out Existing Used Oil Complete All As Specified And As Directed. Make : Servo / Castrol. 76 Supply Only The Following Items In Dg Set Of 250 To160 Kva Capacity. Diesel Filter Element 77 Oil Filter Element 78 Air Cleaner Hose Pipe With Clamp 79 Radiator Hose Pipe With Clamp 80 Safety Control Valve 81 Flexible Pipe For Fuel Pump To Pt Pump With Banjo Washer , Nut Bolt 82 Air Cleaner Filter 83 Supply Only The Following Items In Dg Set Of 30 To 50 Kva Capacity. Diesel Filter Element. 84 Oil Filter Element 85 Air Cleaner Hose Pipe With Clamp 86 Radiator Hose Pipe With Clamp 87 By Pass Filter 88 Air Cleaner Filter 89 Feed Pump 90 Supply Only Self Starter Spare Parts Of Capacity 40 To 250 Kva Self Clutch Assembly 91 Self Pinion Assembly 92 Self Solenoid Switch Assembly 93 Self Carbon Rocker Assembly 94 Self Carbon Brush ( Set Of 4 Pcs ) 95 Supply Only Dynamo Spare Parts Of 30 To 200 Kva Dynamo Rectifier Assembly 96 Dynamo Coutout Assembly 97 Dynamo Stator Assembly 98 Dynamo Plate Set ( Set Of Two Pcs ) 99 Dynamo Carbon ( Set Of 2 Pcs ) 100 Supply, Installation, Testing & Commissioning Of Batteries For Dg Sets Of Capacity 120 Ah, 12 Volt All As Specified. Make :- Exide / Amaron Or Equavalent As Approved By The Ge. 101 Supply, Installation, Testing & Commissioning Of Batteries For Dg Sets Of Capacity 160 Ah, 12 Volt All As Specified. Make :- Exide / Amaron Or Equavalent As Approved By The Ge. 102 Supply, Installation, Testing & Commissioning Of Batteries For Dg Sets Of Capacity 180 Ah, 12 Volt All As Specified. Make :- Exide / Amaron Or Equavalent As Approved By The Ge. 103 Opening Of The Amf Panel By Unsrewing Srews, Nuts Bolts Etc After Removing All Connection To Dg Sets And Lt Panel And Reassemble The Amf Panel After Work As Follows Including All Connection, Commissioning And Testing Complete All As Specified And Directed. Note:- The Reassembling Includes For Labour Element For Replacement Of Unserviceable Parts As Listed Below, Including Minor Parts , Not Listed Below, And The Unit Rate Quoted Is Deemed To Include For The Same. 104 Supply Only The Spare Parts Of Amf Panel As Existing Capacity. Control Relay Coil / Contact Relay Coil 105 Line Voltage Monitor 106 Power Contacor Heavy Duty 4 Pole Any Capacity As Per Sample . 107 Current Transformer 108 Voltmeter ( 0-500 ) Volt, Analog Type With Selector Switch 109 Ammeter ( 0-300 ) Amps, Analog Type With Selector Switch. 110 Supply And Fix Battery Lead With Terminal Cable Of Size 19 Swg X36 Long Set All As Directed. 111 Servicing / Repairing Of Control Panel Of Automatic Power Factor Unit 30 To 110 Kvar Capacities By Replacement Of Unserviceable / Defective / Burnt Out Wiring With Appropriate And Existing Size Copper Flexible Cable Including All Fixing Arrangement And Connections Complete All As Specified And As Directed. Note : ( I ) Cost Of Dressing Of Cables Etc. Including Provision Of Necessary Cable Lugs As Required Are Deemed To Be Inclusive In The Rates. ( Ii ) Spares Shall Be Measured And Paid Seperately As Supply Only The Labour Element Involved For Replaceing Spares Is Deemed To Include In The Unit Rate Quoted. 112 Supply And Fixing 3 Pole Power Contactor 32 Amps Type Ml-2 Including Taking Down Old Unserviceable Power Contractor All As Specififed And Directed. Make-L&T / Havells / C&S / Or As Per Existing ) . 113 Supply And Fixing, In Repair, Digital Volt Meter 0-500 V All As Specififed And Directed. ( Make-L&T / Hpl / C&S Or As Per Existing ) 114 Supply And Fixing Heavy Duty Long Life Power Capacitor ( Kvar ) Of Various Capcity As Per Required At Site, 440 Volts Ac All As Specififed And Directed. ( Make : Havells / L& T / Schinneder / Legrand ) 115 Supply And Fixing , In Repair, Auto Power Controller Suitable For Existing Stage Complete All As Specified And As Directed. Make :Neptune / L&T / Siemens / Schinneder ) 116 Taking Down And Dismantling Of All The Component From Air Blower Of Sewage Treatment Plant Including Servicing / Overhauling By Complete Dismantling Of Serviceable And Semi / Unserviceable Parts, , Cleaning Thouroughly All Interior & Exeterior Parts After Disconnecting The Out-Going Connection Of Repair / Replacement Of Defective Spares And Servicing Of All Parts Which Ever Is Necessary Reassembling The Air Blower Completion Of Work Complete All As Directed By Engineer In Charge For The Air Blowe Of Capacity Up 10 Kw And 1450 Rpm ( I ) Spare Parts Shall Be Measured And Paid Separately Under Relavant Items As Supply Only The Labour Element Involved For Replaceing Spares Is Deemed To Include In The Unit Rate Quoted. ( Ii ) The Unit Rate Quoted Is Deemed To Include For Minors Spares Which Are Not Included Here-In- After. 117 Supply Only The Following Items In Air Blower Of Capacity 10 Kw And 1450 Rpm. Shaft 118 Impeller 119 Bush 120 Air Filter 121 V Belts 122 Pully Assembly 123 Material And Labour For Rewinding Of Air Blower Motor Of Stp Upto 10 Kw, Ac 3 Phase, 415 Volts With Same Gauge Super Enamelled Copper Cable Conforming To Existing Size Including Paper Separator, Cleaning Of Slots, Replacement Of Insulating Materials Etc. And Varnishing With Approved Varnish And Testing Complete All As Specified And Directed. 124 Supply And Fix Radiator In Replacement Of Old Unserviceable Radiatorof Dg Set Of 30 Kva Dg Set Complete All As Specified And As Directed. 125 Supply Only Distill Water For Battry Complete All As Specified And As Directed. 126 Supply And Fix In Replacement Electronic Battry Charger Set Complete All As Specified And As Directed. 127 Supply And Changing Lubricant Oil Of Suitable Grade Including Drain Out Existing Used Oil Complete All As Specified And As Directed. Make : Servo / Castrol. 128 Excavation In Trenches Not Exceeding 1.5 M Width Or N Exc 10 Sqm On Plan And N.Exe 1.5 M In Depth For Taking Out / Laying Of Cable, Foundation Etc And Getting Out In Hard Dense Soil Complete All As Specified And As Directed. 129 Removing Excavated Soil To A Distance Not Exceeding 50 Mtrs And Depositing Where Directed Including Spreading, Leveling At A Level Not Exceeding 1.5 Mtr From The Starting Point Complete All As Specified And As Directed 130 Supply, Laying, Connecting, Testing And Commissioning Of Xlpe Insulated And Pvc Sheathed , Armoured Heavy Duty Ug Cable With Stranded Alluminium Conductors 400 Sqmm X 3.5 Core, 1100 Volt Grade, Laid In Trenches / Wall / Ducts / Roof / Pole / Through Pipe , Compleate All As Specified And As Directed Including Taking Down Old Unserviceable One. Note :- ( I ) Pipe And Bricks For Cable Protection And Sand Cushioning Shall Be Measured And Paid Separately As Per Site . 131 Supply And Lay Gi Pipe 100 Mm Bore ( Dia ) Light Grade In Trenches / Road Crossing For Protection Of Cable With Necessary Fittings As Required Complete All As Specified And As Directed. 132 Cutting Hard Standing / Road For Laying Of Cable / Protection Pipe Complete All As Specified And As Directed. 133 Supply And Fix Straight Through Hot Shrink Cable Joint Kit For Lt Ug Cable Of Size 120 / 95 Sqmm 3.5 Core Including Excavatin Of Earth At Undergruond Cable Fault Position And Making Good Surface At The Fault Position Complete All As Specified And As Directed 134 Material And Labour For Pcc ( 1:3:6 ) Type C-2 ( Using 40 Mm Graded Aggregate ) For Filling And Making Good Of Disturbed Surfaces Of Road / Hard Standing / Copping Of Street Light Pole Etc Complete All As Specified And As Directed. 135 Material And Labour For Sand Cushioning With Clean Dry Sand In Trenches For Cable Protection Complete All As Specified. 136 Supply , Design, Installation Testing & Commissioning Of Factory Made Powder Coated ( Conforming To Norms Of Cpri ) Indoor Type, Dust And Vermine Proof Acb Pannel Of Accomadated Size Compartmentalised Made Out Of 3.15 Mm Thick Crca Steel Sheet Of Suitable Size And Angle Iron 40 Mm X 40 Mm X 6 Mm , Powder Coated Over One Coat Of Red Oxide Primer Suitably Grouted In Pcc -1:2:4, Using 20 Mm Graded Stone Aggregate Including Aluminium Bus Bar , Internal Wiring With Pvc Insulated Single Core Cables Of Copper Conducter Of Suitable Size Duly Numbered With Tags For The Circuits With Hinged Double Door Shutters ( Front And Rear ) , Cubical Type Locking Arrangement .The Panel Board Shall Comprise Of Following Items And All Specified In Ssr Part I Clause No 19.21 As Reqd. And Including Taking Down Old Unserviceable Panel Including Proper Connection Of Incoming Cable To Existing Transformeras Well As Out Gonig Cable To Existing Main Lt Pannel All As Specified And Directed By Engr In Charge. Incoming:- ( I ) Acb Ac 415 Volts, 800 Amp, 4- Pole, 50 Ka Rupturing Capacity With Adjustable Thermal And Fixed Magnetic Setting Confirming To Is13947-11 Complete With Connections To The Bus Bars ( Make -Havells, Cat Part No- Modeiihafe11080000 Or Indoasian Cat No. 820012 Or L&T ) - 01 No. ( Ii ) Aluminium Busbar 800 Amp Capacity Cross Sectional Area Of Aluminium Busbar Should Not Be Less Than 50X8mm With Heat Shrinkable Sleevs Mounted On Dmc Post Insulators, 1100 Volts Grade. - 04 Nos. ( Iii ) Digital Type Voltmeter, ( 100X100mm ) Square Type, 0-500 Volt, Flush Mounting With Selector Switch - 01 Set. ( Iv ) Digital Type Ammeter, ( 100X100mm ) Square Type, Flush Mounting Compleate With Suitable Capacity Of 03 Nos Cts And Selector Switch -01 Set ( V ) Phase Indicator ( Ryb ) Lamps Led Type . -01 Set.Outgoing:- ( I ) Acb Ac 415 Volts, 800 Amp, 4- Pole, 50 Ka Rupturing Capacity With Adjustable Thermal And Fixed Magnetic Setting Confirming To Is13947-11 Complete With Commections To The Bus Bars ( Make -Havells, Cat Part No- Modeiihafe11080000 Or Indoasian Cat No. . 820012 Or L&T ) - 01 No. ( Ii ) Aluminium Busbar 800 Amp Capacity Cross Sectional Area Of Aluminium Busbar Should Not Be Less Than 50X8mm With Heat Shrinkable Sleevs Mounted On Dmc Post Insulators, 1100 Volts Grade. - 04 Nos. ( Iii ) Digital Type Voltmeter, ( 100X100mm ) Square Type, 0-500 Volt, Flush Mounting With Selector Switch - 01 Set. ( Iv ) Digital Type Ammeter, ( 100X100mm ) Square Type, Flush Mounting Compleate With Suitable Capacity Of 03 Nos Cts And Selector Switch -01 Set ( V ) Phase Indicator ( Ryb ) Lamps Led Type . -01 Set. 137 Materials & Labour For Earthing Complete With Galvanized Earth Plate Electrode 600 X 600 X 6.0 Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 M Deep Below Normal Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level, Connected To Gi Strip Of Size 32X6 Mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel, Earth Strip Protected By And Including 40Mm Dia Gi Pipe ( Light Grade ) , Alternate Layers Of Charcoal And Salt, Including 20 Mm Bore Gi Tubing For Watering To Earth Electrode, Earth Strip Connected To Test Point / Distribution Panel / Feeder Pillar Etc As Directed Including Necessary Earth Work, Concrete Pit With Pcc ( 1:3:6 ) Type C1, Pre Cast Rcc ( 1:1:5:3 ) Type A1 Cover Slab Duly Reinforced With 8 Mm Dia Tmt Bar 150Mm C / C Both Way And Two Numbers Lifting Handle Made Of Tmt Bar And Set In Cement Mortar ( 1:4 ) , Funnel, Wire Mesh, All As Shown In Electrical Plate No 3 Of Ssr Part-1 And Testing On Completion Including Taking Out Old Earthing Complete.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Jun-2020 REVISEDBOQ BOQ 14-07-2020
2 14-Jul-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-07-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 42500.0 /-
Tender Value
INR 21.25 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail