Indian Oil Corporation Limited-IOCL has published Dehumidification And Temperature Control In Equipments Of Process Units At Digboi Refinery During M And I Shutdown 2020. Submission Date for this Tender is 10-08-2020. Dehumidifiers Tenders in AOD DIGBOI Assam. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 08-Jul-2020 | Due Date Extension | Date | 18-07-2020 |
2 | 20-Jul-2020 | Due date Extension | Date | 30-07-2020 |
3 | 31-Jul-2020 | Due Date Extension-3 | Date | 10-08-2020 |
Name of Work: Dehumidification and Temperature control in equipments of process units at Digboi Refinery during M&I Shutdown 2020. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 10 | Dehumidification & Temp. control at DR | Item 00010 | ||
2 | 10.01 | Dedumadification service | Item 10.10 | ||
3 | 10.02 | Volume of equipment shall be less than 150 cubic meter (i.e 150 cubic meter is excluded)</></> Dehumidifier and temperature control unit to control moisture, humidity and temperature during maintenance/inspection of column. Relative Humidity will be maintained in the column between 50% to 55% and temperature from 26 to 28 degree Celsius at the outlet of the duct. | Item 10.20 | ||
4 | 10.03 | Mobilization of Dehumidification System/Manpower (For volume less than 150 cubic meter):</></> Charges are inclusive of installation of system and trial run (if any )in equipment, boarding , loading and transportation charges of manpower and all other incidental expanses . Unit of measurement is EACH which implies that one time mobilisation shall be considered as 1 for each dehumidification system. | Item 10.30 | 6 | EA |
5 | 10.04 | De-Mobilization of dehumidification System/Manpower (For volume less than 150 cubic meter):</></> Charges are inclusive of removal of system from equipment / IOCL Site , removal of scrap if any , boarding , loading and transportation charges of manpower / equipment and all other incidental expanses. Unit of measurement is EACH which implies that one time demobilisation shall be considered as 1 for each dehumidification system. | Item 10.40 | 6 | EA |
6 | 10.05 | Rental charges for dehumidification System / man power (For volume less than 150 cubic meter):</></> Rental charges of machines /manpower will be counted for the period of utilization of dehumidifcation system. Time taken for to & fro transportation, installation/de-installation, trial & commissioning of machines shall not be considered for payment of rental charges. Period of utilization shall be certified by EIC/site engineer on daily basis. Unit of measurement 01 day = 24 hrs. utilization of each dehumidification system supplied by vendor for above mentioned volume irrespective of number of columns connected to that system. | Item 10.50 | 86 | DAY |
7 | 10.06 | Volume of equipment shall be from 150 to 500 cubic meter (i.e 150 cubic meter is included and 500 cubic meter is excluded)</></> Dehumidifier and temperature control unit to control moisture, humidity and temperature during maintenance/inspection of column. Relative Humidity will be maintained in the column between 50% to 55% and temperature from 26 to 28 degree Celsius at the outlet of the duct. | Item 10.60 | ||
8 | 10.07 | Mobilization of Dehumidification System/Manpower (For volume from 150 upto 500 cubic meter) :</></> Charges are inclusive of installation of system and trial run (if any )in equipment, boarding , loading and transportation charges of manpower and all other incidental expanses . Unit of measurement is EACH which implies that one time mobilisation shall be considered as 1 for each dehumidification system. | Item 10.70 | 1 | EA |
9 | 10.08 | De-Mobilization of dehumidification System/Manpower (For volume from 150 upto 500 cubic meter):</></> Charges are inclusive of removal of system from equipment / IOCL Site , removal of scrap if any , boarding , loading and transportation charges of manpower / equipment and all other incidental expanses. Unit of measurement is EACH which implies that one time demobilisation shall be considered as 1 for each dehumidification system. | Item 10.80 | 1 | EA |
10 | 10.09 | Rental charges for dehumidification System / man power (For volume from 150 upto 500 cubic meter):</></> Rental charges of machines /manpower will be counted for the period of utilization of dehumidifcation system. Time taken for to & fro transportation, installation/de-installation, trial & commissioning of machines shall not be considered for payment of rental charges. Period of utilization shall be certified by EIC/site engineer on daily basis. Unit of measurement 01 day = 24 hrs. utilization of each dehumidification system supplied by vendor for above mentioned volume irrespective of number of columns connected to that system. | Item 10.90 | 19 | DAY |
11 | 10.1 | Volume of equipment shall be from 500 to 1200 cubic meter (i.e 500 cubic meter is included and 1200 cubic meter is excluded):</></> Dehumidifier and temperature control unit to control moisture, humidity and temperature during maintenance/inspection of column. Relative Humidity will be maintained in the column between 50% to 55% and temperature from 26 to 28 degree Celsius at the outlet of the duct. | Item 10.100 | ||
12 | 10.11 | Mobilization of Dehumidification System/Manpower (For volume from 500 to 1200 cubic meter) :</></> Charges are inclusive of installation of system and trial run (if any )in equipment, boarding , loading and transportation charges of manpower and all other incidental expanses . Unit of measurement is EACH which implies that one time mobilisation shall be considered as 1 for each dehumidification system. | Item 10.110 | 1 | EA |
13 | 10.12 | De-Mobilization of dehumidification System/Manpower (For volume from 500 to 1200 cubic meter):</></> Charges are inclusive of removal of system from equipment / IOCL Site , removal of scrap if any , boarding , loading and transportation charges of manpower / equipment and all other incidental expanses. Unit of measurement is EACH which implies that one time demobilisation shall be considered as 1 for each dehumidification system. | Item 10.120 | 1 | EA |
14 | 10.13 | Rental charges for dehumidification system/ man power (For volume from 500 to 1200 cubic meter):</></> Rental charges of machines /manpower will be counted for the period of utilization of dehumidifcation system. Time taken for to & fro transportation, installation/de-installation, trial & commissioning of machines shall not be considered for payment of rental charges. Period of utilization shall be certified by EIC/site engineer on daily basis. Unit of measurement 01 day = 24 hrs. utilization of each dehumidification system supplied by vendor for above mentioned volume irrespective of number of columns connected to that system. | Item 10.130 | 19 | DAY |