Dehumidification And Temperature Control In Equipments Of Process Units At Digboi Refinery During M And I Shutdown 2020, AOD DIGBOI-Assam

Indian Oil Corporation Limited-IOCL has published Dehumidification And Temperature Control In Equipments Of Process Units At Digboi Refinery During M And I Shutdown 2020. Submission Date for this Tender is 10-08-2020. Dehumidifiers Tenders in AOD DIGBOI Assam. Bidders can get complete Tender details and download the document.




Tender Notice

24665058
Corrigendum : Dehumidification And Temperature Control In Equipments Of Process Units At Digboi Refinery During M And I Shutdown 2020
Open Tender
Indian
Assam
AOD DIGBOI
10-08-2020

Tender Details

Dehumidification And Temperature Control In Equipments Of Process Units At Digboi Refinery During M And I Shutdown 2020

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Jul-2020 Due Date Extension Date 18-07-2020
2 20-Jul-2020 Due date Extension Date 30-07-2020
3 31-Jul-2020 Due Date Extension-3 Date 10-08-2020

Key Value

Document Fees
Refer document
EMD
INR 8789.0 /-
Tender Value
INR 11.25 Lakhs /-

BOQ Items

Name of Work: Dehumidification and Temperature control in equipments of process units at Digboi Refinery during M&I Shutdown 2020.
Sl. No. Item Description Item Code / Make Quantity Units
1 10 Dehumidification & Temp. control at DR Item 00010
2 10.01 Dedumadification service Item 10.10
3 10.02 Volume of equipment shall be less than 150 cubic meter (i.e 150 cubic meter is excluded)</></> Dehumidifier and temperature control unit to control moisture, humidity and temperature during maintenance/inspection of column. Relative Humidity will be maintained in the column between 50% to 55% and temperature from 26 to 28 degree Celsius at the outlet of the duct. Item 10.20
4 10.03 Mobilization of Dehumidification System/Manpower (For volume less than 150 cubic meter):</></> Charges are inclusive of installation of system and trial run (if any )in equipment, boarding , loading and transportation charges of manpower and all other incidental expanses . Unit of measurement is EACH which implies that one time mobilisation shall be considered as 1 for each dehumidification system. Item 10.30 6 EA
5 10.04 De-Mobilization of dehumidification System/Manpower (For volume less than 150 cubic meter):</></> Charges are inclusive of removal of system from equipment / IOCL Site , removal of scrap if any , boarding , loading and transportation charges of manpower / equipment and all other incidental expanses. Unit of measurement is EACH which implies that one time demobilisation shall be considered as 1 for each dehumidification system. Item 10.40 6 EA
6 10.05 Rental charges for dehumidification System / man power (For volume less than 150 cubic meter):</></> Rental charges of machines /manpower will be counted for the period of utilization of dehumidifcation system. Time taken for to & fro transportation, installation/de-installation, trial & commissioning of machines shall not be considered for payment of rental charges. Period of utilization shall be certified by EIC/site engineer on daily basis. Unit of measurement 01 day = 24 hrs. utilization of each dehumidification system supplied by vendor for above mentioned volume irrespective of number of columns connected to that system. Item 10.50 86 DAY
7 10.06 Volume of equipment shall be from 150 to 500 cubic meter (i.e 150 cubic meter is included and 500 cubic meter is excluded)</></> Dehumidifier and temperature control unit to control moisture, humidity and temperature during maintenance/inspection of column. Relative Humidity will be maintained in the column between 50% to 55% and temperature from 26 to 28 degree Celsius at the outlet of the duct. Item 10.60
8 10.07 Mobilization of Dehumidification System/Manpower (For volume from 150 upto 500 cubic meter) :</></> Charges are inclusive of installation of system and trial run (if any )in equipment, boarding , loading and transportation charges of manpower and all other incidental expanses . Unit of measurement is EACH which implies that one time mobilisation shall be considered as 1 for each dehumidification system. Item 10.70 1 EA
9 10.08 De-Mobilization of dehumidification System/Manpower (For volume from 150 upto 500 cubic meter):</></> Charges are inclusive of removal of system from equipment / IOCL Site , removal of scrap if any , boarding , loading and transportation charges of manpower / equipment and all other incidental expanses. Unit of measurement is EACH which implies that one time demobilisation shall be considered as 1 for each dehumidification system. Item 10.80 1 EA
10 10.09 Rental charges for dehumidification System / man power (For volume from 150 upto 500 cubic meter):</></> Rental charges of machines /manpower will be counted for the period of utilization of dehumidifcation system. Time taken for to & fro transportation, installation/de-installation, trial & commissioning of machines shall not be considered for payment of rental charges. Period of utilization shall be certified by EIC/site engineer on daily basis. Unit of measurement 01 day = 24 hrs. utilization of each dehumidification system supplied by vendor for above mentioned volume irrespective of number of columns connected to that system. Item 10.90 19 DAY
11 10.1 Volume of equipment shall be from 500 to 1200 cubic meter (i.e 500 cubic meter is included and 1200 cubic meter is excluded):</></> Dehumidifier and temperature control unit to control moisture, humidity and temperature during maintenance/inspection of column. Relative Humidity will be maintained in the column between 50% to 55% and temperature from 26 to 28 degree Celsius at the outlet of the duct. Item 10.100
12 10.11 Mobilization of Dehumidification System/Manpower (For volume from 500 to 1200 cubic meter) :</></> Charges are inclusive of installation of system and trial run (if any )in equipment, boarding , loading and transportation charges of manpower and all other incidental expanses . Unit of measurement is EACH which implies that one time mobilisation shall be considered as 1 for each dehumidification system. Item 10.110 1 EA
13 10.12 De-Mobilization of dehumidification System/Manpower (For volume from 500 to 1200 cubic meter):</></> Charges are inclusive of removal of system from equipment / IOCL Site , removal of scrap if any , boarding , loading and transportation charges of manpower / equipment and all other incidental expanses. Unit of measurement is EACH which implies that one time demobilisation shall be considered as 1 for each dehumidification system. Item 10.120 1 EA
14 10.13 Rental charges for dehumidification system/ man power (For volume from 500 to 1200 cubic meter):</></> Rental charges of machines /manpower will be counted for the period of utilization of dehumidifcation system. Time taken for to & fro transportation, installation/de-installation, trial & commissioning of machines shall not be considered for payment of rental charges. Period of utilization shall be certified by EIC/site engineer on daily basis. Unit of measurement 01 day = 24 hrs. utilization of each dehumidification system supplied by vendor for above mentioned volume irrespective of number of columns connected to that system. Item 10.130 19 DAY