Military Engineer Services-MES has published Addition And Alteration And Special Repairs To Jcos / Or Married Accn At Missamari Under Ge Missamari. Submission Date for this Tender is 01-09-2020. Building Repair Tenders in MISSAMARI Assam. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 30-Jun-2020 | Date corrigendum 1 | Date | 23-07-2020 |
2 | 13-Jul-2020 | Date Corrigendum - 2 | Date | 06-08-2020 |
3 | 30-Jul-2020 | Date Corrigendum - 3 | Date | 24-08-2020 |
4 | 14-Aug-2020 | Amendment-1 | Other | 01-09-2020 |
5 | 17-Aug-2020 | Amendment-1 | BOQ | 01-09-2020 |
NAME OF WORK : ADDN / ALTN AND SPECIAL REPAIRS TO JCOs / OR MARRIED ACCN AT MISSAMARI UNDER GE MISSAMARI | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Qty. | Units | |
1 | 1 | B/R WORKS (Sch 'A' PART-I) | |||
2 | 1.01 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and as directed. | 398 | SQM | |
3 | 1.02 | Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings including ridge complete all as specified and as directed. | 1467 | SQM | |
4 | 1.03 | S & F of Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick and colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete. | 2396 | SQM | |
5 | 1.04 | S & F of Prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick and colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete. | 190 | SQM | |
6 | 1.05 | Dismantling of ceilling boards of any description including cover fillets etc. complete all as specified and as directed. | 1115 | SQM | |
7 | 1.06 | S&F of false ceiling with 4mm thick designer 'E' Board of Everest Ltd or Charminar as approved by GE fixed with GI powder coated inverted Tee or 'L' section (Concealed GI frame work) of cicago metallic or Equivalent as approved by GE suspended from ceiling with FI 25x5 mm thick or butterfly hold down clips with necessary hold fastners / self tapping screws as per manufacturer instruction complete all as specified and as directed including the following :-\n(a) Main runner of size 39x24.7x0.8mm \n(b) Cross tee size 29x24.7x0.8mm \n(c) Wall angle 22.2x22.2x0.65mm \n(d) Butter fly clip / hold down clip \n(e) Size of grid 605x605mm \n(f) Two coats oil bound distemper on one side of board\n(g) Powder coating on exposed side of tee/angle | 1115 | SQM | |
8 | 1.07 | Dismantling timber scantling 40 sqcm and over in section unframed work in any position complete all as specified and directed. | 0.5 | CUM | |
9 | 1.08 | M&L for second class hard wood as in scantling, clean sawn, timber fixed with nails complete all as specified and as directed. | 0.5 | CUM | |
10 | 1.09 | Demolition PCC as in Roof padding (including APP membrane chajjas and similar item) complete all as specified and as directed. | 84.18 | CUM | |
11 | 1.1 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:-\n(i) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying as in roof Slab.\n(ii) Applying one coat of cold bituminous primer industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces. \n(iii) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrane shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction and sealing the joints with application of cold bitumen.\n(iv) Applying two coats of aluminum paint over the APP membrane . | 2700 | SQM | |
12 | 1.11 | Taking up or down GI tubing 15mm bore and connection complete all as specified and as directed. | 1248 | RM | |
13 | 1.12 | Taking up or down GI tubing 20mm bore and connection complete all as specified and as directed. | 624 | RM | |
14 | 1.13 | S&F of GI tubing 15mm bore medium grade with all fittings complete all as specified and as directed. | 1040 | RM | |
15 | 1.14 | Refixing only 15mm bore GI tube, any grade, to walls and ceilings or laying in floors complete all as specified and as directed. | 208 | RM | |
16 | 1.15 | S&F GI tubing 20mm bore, medium grade with all fittings complete all as specified and as directed. | 520 | RM | |
17 | 1.16 | Refixing only 20 mm GI tube, any grade, to walls and ceilings or laying in floors complete all as specified and as directed. | 104 | RM | |
18 | 1.17 | S & F in repair 15mm bore fancy type pillar tap, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and as directed. | 31 | EACH | |
19 | 1.18 | S & F of 15mm bore fancy type pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and as directed. . | 68 | EACH | |
20 | 1.19 | S&F in repair, CP bib tap 15 mm bore, fancy type, screwed down, high pressure, screwed for iron pipe complete all as specified and as directed. | 208 | EACH | |
21 | 1.2 | S&Fof ISI marked 15mm bore stop valve/Angular stop cock fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed. | 268 | EACH | |
22 | 1.21 | S&F in repair ISI marked 15mm bore stop valve/Angular stop cock fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed. | 148 | EACH | |
23 | 1.22 | S&F of 20mm dia brass CP tubular towel rail D type 60 cm long fixed with bracket complete all as specified and directed. | 104 | EACH | |
24 | 1.23 | S & F in repair over Head Shower 150 mm dia , single flow suitable for fixing to 15mm bore (dia) GI Pipe including CP shower arm 15mm dia complete all as specified and as directed. | 104 | EACH | |
25 | 1.24 | S&F of CP Brass Wall mixer 3 in 1 Chromium plated for mixing hot and cold water screwed down for iron pipe and fixed with connections with and including L bend for shower provision complete all as specified and as directed. | 104 | EACH | |
26 | 1.25 | S&F in repair for Grating doom 100mm dia of PTMT (minimum weight 25gms) complete all as specified and as directed. | 312 | EACH | |
27 | 1.26 | S&F of 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. | 312 | EACH | |
28 | 1.27 | S&F in repair for Rotational moulded polyethylene water storage tanks triple layer (white) 500 ltrs capacity (cylindrical vertical with closed top) including wash out GI pipe 32mm of 450mm length with stopper complete all as specified and as directed. | 30 | EACH | |
29 | 1.28 | Disconnecting the inlet / outlet pipe connection and 20mm dia float valve of existing service water storage tank of exceeding 250 & not exceeding 500 Ltr capacity PVC on roof / staging, cleaning the tank by removing all scales, dirt, mud and finally washing inside and outside with clean water, re-connecting the inlet / outlet pipe line and float valve and testing for clear flow of water, including repalcement of float valve marking outside date of cleaning & due date with synthetic paint, complete all as directed by Engr-in-Charge.\n | 74 | EACH | |
30 | 1.29 | S&F of sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed. | 104 | EACH | |
31 | 1.3 | S&F of kitchen sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste pipe, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160mm complete all as specified and as directed. | 68 | EACH | |
32 | 1.31 | S&F in repair kitchen sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste pipe, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160mm complete all as specified and as directed. | 18 | EACH | |
33 | 1.32 | S&F of kitchen plate rack made of stainless steel sheet not less than 0.63mm thick of over all size 1050mm x 750mm x250mm complete all as specified and as directed. | 104 | EACH | |
34 | 1.33 | S&F in repair PVC valve less, Syphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete all as specified and as directed by Engineer-in-Charge. | 65 | EACH | |
35 | 1.34 | S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and as directed. | 312 | RM | |
36 | 1.35 | S&F in repair PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and as directed. | 936 | RM | |
37 | 1.36 | S&F in repair PVC (SWR) vent cowl 110mm dia complete all as specified and as directed. | 52 | EACH | |
38 | 1.37 | S&F in repair PVC (SWR) vent cowl 75 mm dia complete all as specified and as directed. | 104 | EACH | |
39 | 1.38 | S&F in repair PVC (SWR) 110mm dia in junction single, (Single T) equal or unequal complete all as specified and as directed. | 52 | EACH | |
40 | 1.39 | S&F in repair PVC (SWR) bend of any radius 110mm bore complete all as specified and as directed. | 52 | EACH | |
41 | 1.4 | S&F in repair PVC (SWR) bend of any radius 75 mm bore complete complete all as specified and as directed. | 104 | EACH | |
42 | 1.41 | S&F in repair PVC (SWR) 75 mm dia in junction single, (Single T) equal or unequal complete all as specified and as directed. | 104 | EACH | |
43 | 1.42 | S&F of 20mm dia Ball cock valve high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms) complete all as specified and as directed. | 30 | EACH | |
44 | 1.43 | S&F of Gun-metal, globe or gate valve 20mm bore, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. | 208 | EACH | |
45 | 1.44 | S&F of 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed. | 104 | EACH | |
46 | 1.45 | S&F in repair Harrison rail, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed. | 1548 | RM | |
47 | 1.46 | S&F in repair Vitreous china wash hand basin, white, flat back of size 550 mm x 400 mm including bracket, cutting for and pinning the ends of brackets or erecting stands also including brass chromium plated waste coupling 32mm dia, PVC flexible waste pipe of adequate length and dia and PVC connection 15mm size 600mm length with PTMT nuts,, including dispose off the broken WHB out of defence land complete all as specified and as directed. | 10 | EACH | |
48 | 1.47 | S&F of Vitreous china wash hand basin, white, flat back of size 550 mm x 400 mm including bracket, cutting for and pinning the ends of brackets or erecting stands also including brass chromium plated waste coupling 32mm dia, PVC flexible waste pipe of adequate length and dia and PVC connection 15mm size 450mm length with PTMT nuts,complete all as specified and as directed. | 68 | EACH | |
49 | 1.48 | S&F in repair for PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and as directed. | 104 | EACH | |
50 | 1.49 | M&L for Vitreous china squatting pan of Orissa Pattern of size 580x 440 mm white with PVC ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe including placing in position in floor and embedded in cushion of PCC , and finishing the top surfaces to match with the existing flooring as in repair including dispose off the broken WC out of defence land complete all as specified and as directed. | 99 | EACH | |
51 | 1.5 | S&F of wash down water closet (pedestal pattern) vitreous china white including sheet cover, connection to drain or out going pipe and to flushing pipe anti-syphonage pipe etc, fixed in repair, including dispose off the broken WC out of defence land complete all as specified and as directed. | 5 | EACH | |
52 | 1.51 | S&F of Bathroom Cabinet of hard thermosetting plastic of size 600x450 mm, fitted with superior quality distortion free 4 mm thick mirror, complete all as specified and as directed. | 104 | EACH | |
53 | 1.52 | Taking down chowkhat or frame with shutter without taking off shutter from the frame exceeding 1.50 SQM but not exceeding 4 SQM each & removing from site complete all as specified and as directed. | 818 | EACH | |
54 | 1.53 | Taking down chowkhat or frame with shutter without taking off shutter from the frame not exceeding 1.50 SQM & removing from site complete all as specified and as directed. | 928 | EACH | |
55 | 1.54 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and incl either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging; also fastening and fixing in repair complete Fe-290 (Gd E-165) complete all as specified and as directed. | 7580 | KG | |
56 | 1.55 | S&F of second class hard wood plain solid straight chowkhats/frame wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed. | 4.8 | CUM | |
57 | 1.56 | S&F of powder coated aluminium anodised frame for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc, complete all as specified and directed. | 1955 | KG | |
58 | 1.57 | S&F of powder coated aluminium anodised window/ventilator shutter side hung type without sash bar, aluminium section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber neoprene packing, anodised powder coated aluminium snap beading screws,B-21 type aluminium butt hinges 100mm long-02 Nos on each shutter, peg stays 150mm long 01 Nos all as specified and as directed.\nNOTE :-\n(i) Fixing of shutter with all powder coated fittings shall be as per manufactures instruction.\n(ii) Rate quoted is deemed to be inclusive of aluminium hardware as indicated, glazing clips, rubber packing, hinges, anodised aluminium snap on beading for fixing glass panes in frame, handles, locking arrangement but glass panes in frame shall be measured and paid separately under relevant Sch items at supply only rates. | 1358 | SQM | |
59 | 1.58 | M&L for mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted forged into spikes, framed guard bars, railings and similar work complete conforming to Fe-410-0 or Fe-310-0 complete all as specified and as directed. | 10378 | KG | |
60 | 1.59 | Supply only sheet glass, tinted, 4mm thick, glazing in aluminium frames, area not exceeding 0.50 SQM in each pane, complete all as specified and as directed. | 600 | SQM | |
61 | 1.6 | Supply only frosted glass, 4mm thick, glazing in aluminium frames, area not exceeding 0.50 SQM in each pane, complete all as specified and as directed. | 175 | SQM | |
62 | 1.61 | S&F of second class hard wood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares (without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkat complete all as specified and as directed.. | 271 | SQM | |
63 | 1.62 | S&F of factory made Flush shutter, solid core construction 30mm thick with block board core and plywood face panels, commercial type on both sides conforming to IS-2202(Part-I), 1983 complete all as specified and as directed. | 652 | SQM | |
64 | 1.63 | S&F of factory made Flush shutter, solid core construction 25mm thick with block board core and plywood face panels, commercial type on both sides conforming to IS-2202(Part-I), 1983 complete all as specified and as directed. | 337 | SQM | |
65 | 1.64 | S&F of factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. | 988 | RM | |
66 | 1.65 | S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes all around . M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and as directed. | 284 | SQM | |
67 | 1.66 | S&F of 100mm size butt hinges cold rolled mild steel medium weight, ISI marked complete all as specified and as directed. | 2400 | EACH | |
68 | 1.67 | S&F of 150 mm size Aluminium anodised handles cast type,ISI marked complete all as specified and as directed. | 2016 | EACH | |
69 | 1.68 | S&F of ISI Marked 150mm long aluminium, anodized, barrel tower bolts of extruded section complete all as specified and as directed. | 2016 | EACH | |
70 | 1.69 | S&F of 250mm long MS sliding door bolt, plate type, stove enameled black with bright bolt not less than 12mm dia with and including a min of siz bolt & nuts four on bolt & two on staple,ISI marked, complete all as specified and as directed. | 418 | EACH | |
71 | 1.7 | S&F of galvanised stainless steel wire mesh 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples complete all as specified and as directed. | 782 | SQM | |
72 | 1.71 | Demolition of plain cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. | 74.93 | CUM | |
73 | 1.72 | M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection including finishing even & smooth without using extra cement including joint filling with bitumen complete all as specified and directed. | 583 | SQM | |
74 | 1.73 | M&L for PCC (1:2:4) type B-1, 100mm thick (using 20mm graded stone aggregate) as in floor/hardstanding finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed. | 312 | SQM | |
75 | 1.74 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises \nNOTE : All internal doors shall be removed before fixing of tile and shall be refix after completion of tiling work. (Taking down and refix item shall be paid separately). | 3195 | SQM | |
76 | 1.75 | M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. \nNOTE : All internal doors shall be removed before fixing of tile and shall be refix after completion of tiling work. (Taking down and refix item shall be paid separately). | 3885 | SQM | |
77 | 1.76 | M&L for non-skid ceramic colour tiles 7 to 8 mm thick , (square/ rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar (1:4) complete all as specified and as directed. | 745 | SQM | |
78 | 1.77 | M&L for Glazed ceramic colour tiles of size 300 x 450 x 7mm thick in vertical wall etc set and jointed with neat cement slurry and pointed in white or coloured cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar (1:4) complete as specified and as directed. | 2450.14 | SQM | |
79 | 1.78 | M&L for non-skid ceramic colour tiles 7 to 8 mm thick , (square/ rectangular), area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar (1:4) complete all as specified and as directed. | 3885 | SQM | |
80 | 1.79 | All as per Serial Item No. 1.78 above but as in vertical surfaces such as wall, skirting and dado etc set and jointed with neat cement slurry and pointed in white or coloured cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar (1:4) complete as specified and directed. | 388.5 | SQM | |
81 | 1.8 | M&L for Marble of green shade other than white and black, 18 to 20mm thick (table rubbed and polished) in steps, bathroom self, corner (including necessary cutting chasing) jambs,pillars, window cills, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed. | 153 | SQM | |
82 | 1.81 | M&L for sunken floor treatment as in following precedence :-\n(i) Provide 40mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in sub base and provide 40mm bore GI pipe med gde as in (spout) of 600mm long as in sunken portion.\n(ii) The treatment of existing sunken floor is to be dismantled upto full depth of Sunken RCC Slab and the surfaces both vertical and horizontal shall be cleaned by removing all loose mortar, dirt, dust etc. by chisel, hammer, wire brush/Jute Brush and Air Blower machine than apply two coats of elastomeric compound viz back bond WPC-30 over one coat on neat primer i.e. Super latex be applied on clean surface. \n(iii) Then rendering 15mm thick in CM (1:3) using liquid water proofing compound @ rate 200 ml per 50 Kg bag of cement on horizontal and vertical surfaces of sunken portion. (Note : Water proofing compound shall be measured and paid separately).\n(iv) Then fill the remaining sunken portion with PCC (1:5:10) using brick aggregates including fixing sanitary items requiring embedding in cement concrete. \n(v) The sunken floor tested for leakage/seepage by ponding it with water for minimum 48 hrs. To ensure that there shall not be any seepage/dampness in the slab as seen underneath and side. | 372 | SQM | |
83 | 1.82 | Supply only liquid water proofing compound complete all as specified and as directed. | 40 | LTR | |
84 | 1.83 | M&L for brick work with sub class B bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and as directed. | 27 | SQM | |
85 | 1.84 | Demolition of brick work built in cement mortar incl all quoins arches pillars etc. complete all as specified and as directed. | 5 | CUM | |
86 | 1.85 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 mtr mean radius built in CM (1:6) complete all as specified and as directed. | 2.4 | CUM | |
87 | 1.86 | Demolition of reinforced cement concrete of any description and in any position and rubbish off the premises complete all as specified and as directed. | 1 | CUM | |
88 | 1.87 | M&L for RCC (1:2:4) type B-1,(using 20mm graded crushed stone aggregate) as in slab supported on walls, beam and column in floors , roofs, landing deck slab etc. complete all as specified and as directed. | 1 | CUM | |
89 | 1.88 | M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (horizontal or slopping) complete all as specified and as directed. | 18 | SQM | |
90 | 1.89 | M&L for TMT Bars 10 mm dia & over, cut to length, bent to shape required, including cranking, binding spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and as directed. | 120 | KG | |
91 | 1.9 | S&F in repair bands, scrapes, supports, clamps, hold fast , wind ties, hook, purlin Rafter for hanging fans, angle cleats and similar small articles etc. including necessary welding wherever required all as specified and as directed. | 200 | KG | |
92 | 1.91 | Taking down cement plaster including raking out joints, hacking for key scrubbing down with water etc including removal of rubbish material from site complete all as specified and as directed. | 1800 | SQM | |
93 | 1.92 | M&L for rendering 15mm thick plaster in CM (1:4) mixed with water proofing compound on fair faces of brick work or concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and as directed. \nNOTE : Water proofing compound shall be measured and paid separately. | 1200 | SQM | |
94 | 1.93 | M&L for 15 mm thick plaster in CM (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and as directed. | 400 | SQM | |
95 | 1.94 | M&L for 5mm thick plaster in CM (1:3) on fair faces of concrete surfaces of ceiling including finishing even & smooth without using extra cement complete all as specified and as directed. | 200 | SQM | |
96 | 1.95 | M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion complete all as specified and as directed. | 400 | SQM | |
97 | 1.96 | M&L for White wash, three coats on new ceiling surfaces including necessary preparation of surfaces complete all as specified and as directed. | 200 | SQM | |
98 | 1.97 | M&L for preparation of old decorated plastered surfaces of ceiling including cornices, pilasters etc and applying one coat of white wash complete all as specified and directed. | 4000 | SQM | |
99 | 1.98 | M&L for complete removal of existing treatment by scrapping, wire brushing from walls and applying two coats of oil bound distemper including preparation of surfaces complete all as specified and as directed. | 17750 | SQM | |
100 | 1.99 | M&L for applying a coat of 1.5 mm thick Birla wall care putty as per manufacturer's instruction complete all as specified and as directed.\nNOTE : The complete white wash/colour wash to be removed and shown to department before applying wall care putty Quarter wise approval of MES executive is to be taken for readiness of wall for wall care putty | 18150 | SQM | |
101 | 2 | M&L for preparation of new/(old after complete removal of existing treatment by scraping wire brushing up to height of 7 mtr) plastered surfaces of walls and applying two coats of weather proof paint (Exterior grade) over a coat of alkali resistant primer complete all as specified and as directed. | 8920 | SQM | |
102 | 2.01 | M&L for preparation of new wood and wooden based surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over coat of pink primer complete all as specified and as directed. | 2800 | SQM | |
103 | 2.02 | M&L Preparation of old wood and wooden based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. | 438 | SQM | |
104 | 2.03 | M&L for preparation of new or previously untreated surfaces steel surface and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. | 1783 | SQM | |
105 | 2.04 | S&F of continuous (piano) hinges, mild steel, bright finish or electrogalvanised width of flap 30 mm complete all as specified and as directed. | 870 | RM | |
106 | 2.05 | M& L for Block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on both face complete all as specified and as directed. | 296 | SQM | |
107 | 2.06 | S&F of magnetic PVC catcher for kitchen cup board complete all as specified and as directed. | 208 | EACH | |
108 | 2.07 | S&F of 40mm dia, cupboard knob fixed with nut, screw and washer of mild steel, bright finished complete all as specified and as directed. | 208 | EACH | |
109 | 2.08 | S&F of Wind tie for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. | 1225 | KG | |
110 | 2.09 | Excavating in post holes (or simlar holes) each not exceeding 0.50 CUM getting out returing filling in and ramming earth as broken rubble mixed with earth around in layers not exceeding 25 cm watering & removing surplus soil to a distancenot exceeding 50 m and making good surface complete all as specified and as directed. | 204 | EACH | |
111 | 2.1 | M&L for PCC type B2 (1:2:4) (using 40 mm graded crushed stone aggregate) as in fixing of Post holes complete all as specified and as directed. | 24 | CUM | |
112 | 2.11 | S&F of Steel work in tubular trusses, poles, purlins, etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1998 grade ST-240 complete all as specified and as directed. | 7750 | KG | |
113 | 2.12 | Taking down Wash basins, Vitreous China (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and as directed. | 5 | EACH | |
114 | 2.13 | Taking down and Fixing only Sinks kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf walls, or including fixing cantilever brackets and connecting union to waste pipe; upto 0.5 sqm each complete all as specified and as directed. | 5 | EACH | |
115 | 2.14 | Taking down Shutter from the frame exceeding 1 sqm but not exceeding 2 sqm and refixing after cutting in straight line to reduce the size in same opening complete all as specified and as directed | 36 | PER LEAF | |
116 | 2.15 | Sub total | |||
117 | 3 | E/M WORKS - INTERNAL ELECTRIC SUPPLY (Sch 'A' PART-II) | |||
118 | 3.01 | Taking down carefully unserviceable aluminium point wiring light/fan/socket or power complete and including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc) and removing material from site to store for keeping in safe custody or for taking credit or for reuse at site (To be measured only when found serviceable in all respect complete for reuse) and making good to the disturbed surface matching with existing specification complete all as specified and as directed. \n(NOTE : All old materials have to kept & shown at site to the Engr-in-Charge before removal.) | 2926 | PER POINT | |
119 | 3.02 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store to keep it in safe custody for refixing complete all as specified and as directed. | 244 | EACH | |
120 | 3.03 | M&L for Painting of ceiling fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. with marking of MES No of any type of fan including replacement of fan canopy and three core copper flexible cord of 23/0.193 mm size from ceiling rose to fan connector complete all as specified and as directed. | 244 | EACH | |
121 | 3.04 | Taking down carefully unserviceable aluminium submain wiring of any type /location including conduit /casing and earth wire and making distributed surface of walls /ceiling matching with existing colour complete all as specified and as directed. | 1148 | RM | |
122 | 3.05 | Taking out unserviceable LT UG Cable cross sectional area 16-50 Sqmm 3.5 Core and connection of any description laid in trenches or fixed with wall or poles complete all as specified and as directed. | 925 | RM | |
123 | 3.06 | Taking down unserviceable DB/Main switches / Electric Meter of any type and any capacity including taking out MCB/s (SP/SPN) complete all as specified and as directed. | 234 | EACH | |
124 | 3.07 | M&L point wiring with 1.5 sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 Volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less than 20 mm dia and conduit accessories (ISI marked) concealed in wall / fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI Marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of GI sheet steel not less than 1.22 mm thick duly painted with aluminium inside and anticorrosive paint out side, concealed in walls with 3 mm thick bakelite / plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall / floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. where concealing of conduit is not feasible i.e. on surface of roof etc. conduit shall be fixed with necessary saddles at no extra cost complete all as specified and as directed for the following :-\n\n Item continued as 3.08 to 3.13 | |||
125 | 3.08 | (a) One light /ceiling / exhaust fan point controlled by one switch | 1824 | PER POINT | |
126 | 3.09 | (b) One call bell point controlled by one bell push | 104 | PER POINT | |
127 | 3.1 | (c) One socket outlet 5 Amps point on same board. | 312 | PER POINT | |
128 | 3.11 | (d) One light point controlled by two, two-way switches. | 26 | PER POINT | |
129 | 3.12 | (e) One socket outlet 5 Amps on independent board | 348 | PER POINT | |
130 | 3.13 | (f) One socket outlet 15 Amps point on independent board with 2.5 sqmm single core PVC insulated unsheathed FR-LS cable 1100 Volts grade (ISI marked) multistranded with 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor. | 312 | PER POINT | |
131 | 3.14 | S&F of Switch piano flush type single pole one way 5/6 Amp, 230 Volts (ISI marked) complete all as specified and as directed. | 2136 | EACH | |
132 | 3.15 | S&F of Switch piano flush type single pole one way 5 Amp, 230 Volts (ISI marked) complete all as specified and as directed. | 52 | EACH | |
133 | 3.16 | S&F of Socket outlet 5 pin, 5A, 230 Volts (ISI marked) flush type complete all as specified and as directed. | 312 | EACH | |
134 | 3.17 | S&F of Switch socket combination 2 in 1 3 pin, 5 A, 230 Volts (ISI marked) flush type complete all as specified and as directed. | 348 | EACH | |
135 | 3.18 | S&F of Switch socket combination 2 in 1, 5 pin, 5/15 Amp, 230 Volts (ISI marked) flush type universal complete all as specified and as directed. | 312 | EACH | |
136 | 3.19 | S&F of ceiling rose , bakelite / polycarbonate, isolated body, three terminals, 65 mm (ISI marked) complete all as specified and as directed. | 1034 | EACH | |
137 | 3.2 | S&F of Lamp holder/angle holder, 230 Volts, PVC / Polycarbonate type, insulated body with black/white plate suitable for batten fittings complete all as specified and as directed. | 416 | EACH | |
138 | 3.21 | S&F of stepped type electronic fan regulator, AC, 230 Volts suitable for 1200 / 1400 mm sweep energy saving fans, (ISI marked) complete all as specified and as directed. | 348 | EACH | |
139 | 3.22 | S&Fof bell push,5 Amp, flush type (ISI Marked) complete all as specified and as directed. | 104 | EACH | |
140 | 3.23 | S&F of Call Bell, Ding Dong type, AC, single pole 220/240 Volts, surface type complete all as specified and as directed. | 104 | EACH | |
141 | 3.24 | S&Fof Decorative wall light fixture made up of polycarbonate suitable for 10W LED complete all as specified and as directed.\nNOTE : LED Lamp 10W shall be paid separately. | 348 | EACH | |
142 | 3.25 | S&F of energy saving environmental friendly, surface mounted LED Bulk head suitable for 1 x 10 W LED including LED lamp 10 W complete all as specified and as directed. Cat No. HEXAFT10W LED857SSYMBOPC Make - Havells or equilvalent make of Crompton / Bajaj. | 52 | EACH | |
143 | 3.26 | S&F of LED batten surface / wall mounted with aluminium housing & integrated electronic driver with LED 18 Watt 4 feet long fixing on PVC / Wooden round block complete with all accessories, pre-wired and flexible wire twin core from ceiling rose to terminal block complete all as specified and as directed. Cat No. LUMILINEPLUSBS18WLED865SPCSS, MAKE : Havells or equivalent make of Surya. | 402 | EACH | |
144 | 3.27 | S&F of LED Lamp 10 W B22 CDL 5 STAR LAMP with B 22 base capacity 1200 lumen complete all as specified and as directed.\nMAKE : Havells, Cat No. LHLDEUEBML8Z010 or equivalent in CG or Polycab. | 764 | EACH | |
145 | 3.28 | S&F of Sheet steel enclosure TPN distribution boards, double door factory made 3 phase 415 volts 4 way IP -43 protection, metal door, provided with 100 A insulated phase bus bars/neutral bars with shrouds/ earth bars/ sticking saddle/ cement spill protector/ colour coded interconnecting wire set/cable ties /blanking plates and circuit identification lables and 12 outgoing MCBs with a provn for MCB TPN(FP) as incomer and SP MCB as out going complete all as specified and as directed.\nMAKE : L&T Model-DBTPE004DD or equivalent make of Havells. | 26 | EACH | |
146 | 3.29 | S&F of MCB Distribution Boards (DBs) with sheet metal enclosure,, double door, IP 43 protection, 240 Volts, 8 way, Single Pole and neutral, with 100 Amps rated copper bus bar (as per OEM), neutral link, earth link, earthing studs, suitable for fixing of MCBs, without MCBs fixed flush to wall / other surface complete all as specified and as directed. Cat No. DHDPSHODPW08 MAKE : Havells or equivalent make of L&T. | 104 | EACH | |
147 | 3.3 | S&F of MCB triple pole and neutral (TPN), 63A,10 KA, C -Curve, 44 Volts complete all as specified and as directed. Cat No. DHMGCTNF063 MAKE Havells or equivalent make of L&T / Legrand. | 26 | EACH | |
148 | 3.31 | S&F of 6 Amp MCB single pole 240 V 10 KA complete all as specified and as directed.\nMAKE : L&T, Cat No. BB10200B or equivalent make of Schneider or Legrand. | 308 | EACH | |
149 | 3.32 | S&F of 10 Amp MCB single pole 240 V 10 KA complete all as specified and as directed. \nMAKE : L&T Cat No- BB10200B or Equivalent in Schneider or Legrand. | 232 | EACH | |
150 | 3.33 | S&F of MCB single pole with neutral 240 volts 32 Amps complete all as specified and as directed.\nMAKE : L&T Cat No- BB20250B or Equivalent in Schneider or Legrand. | 208 | EACH | |
151 | 3.34 | S&F of Blanking plates half module suitable for DBs complete all as specified and as directed.\nMAKE : L&T Cat No- BKP05 or Equivalent in Schneider or Legrand. | 68 | EACH | |
152 | 3.35 | M&L for submain wiring for main DBs to sub DBs with PVC insulated unsheathed FR-LS cable 1100 Volts grade of size 6 Sqmm x 2 run alongwith earth continuity wire connected from main earth of size 6 Sqmm x 1 run, ISI marked, multistranded copper conductor single core cable drawn in and inculding non-metallic rigid PVC medium grade conduit and conduit accessories (ISI Marked) concealed in wall / fixed to roof ceiling etc of size 25 mm as required complete all as specified and as directed.\nNOTE : Two runs of 6 Sqmm conductor for main and one run of 6 Sqmm conductor as earth wire with PVC conduit shall constitute one unit. Connections of cables with MCBs or bus bars shall be done through appropriate size brass / copper thimbles. | 1148 | PER RM | |
153 | 3.36 | M&L for earthing as in repair complete with galvanised iron earth plate electrode size 600 mm x 600 mm x 6 mm thick, burried directly and prefably vertically in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected with galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 15 mm bore (medium grade) and other end connected to earthing test point including providing funnel and watering pipe 20 mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15 cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20 mm graded stone aggregate), 50 mm thick precast RCC (1:2:4) cover slab (reinfoced with 8 mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10 mm dia) including necessary earth work, excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I (2009) complete including test point and testing on completion all as specified and as directed by the Engineer-in-Charge. | 52 | EACH SET | |
154 | 3.37 | Supply,laying,jointing and testing of 35 Sqmm 3.5 core XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor (ISI marked) laid in trenches/ drawn into pipes, fixed to poles/walls complete all as directed including taking out the old burnt out cables complete all as specified and as directed. | 925 | RM | |
155 | 3.38 | Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth and getting out in soft/loose soil for taking up or laying of cable complete all as specified and as directed. | 109.35 | CUM | |
156 | 3.39 | Boring holes horizontally under Road without damaging the surface of Road of any type (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exceeding 50mm bore (dia) for passing of UG Cable, complete all as specified and as directed. \nNOTE : GI Pipe laid shall be measured and paid separately under relevant Item. | 105 | RM | |
157 | 3.4 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and as directed. | 75.6 | CUM | |
158 | 3.41 | Removing excavated material not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above starting point complete all as specified and as directed. | 33.75 | CUM | |
159 | 3.42 | Supply and laying dry river sand laid in trenches including punning down consolidation for cable cushioning and covering complete all as specified and as directed. | 27.34 | CUM | |
160 | 3.43 | M&L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and as directed. | 3240 | EACH | |
161 | 3.44 | M&L for GI tube, light grade (ISI Marked) galvanised with all fittings laid in trenches/ fixed to wall / laid under road or floor of 50 mm bore complete all as specified and as directed. | 312 | RM | |
162 | 3.45 | Hanging only ceiling fan so obtained from Serial Item No. 3.02 and connecting up including provision of cable from ceiling rose or connector to fan all as directed by Engr- in-charge. | 244 | EACH | |
163 | 3.46 | Fixing only Electric Meter of any type and make obtained from Serial Item No. 3.06 and connecting the Electric Meter upto 25 amps all as specified and directed by Engr-in -charge. | 104 | EACH | |
164 | 3.47 | Fixing only serviceable tubelight fitting of any type and make obtained from Serial Item No. 3.01 above including replacement of 3-core multistranded copper conductor of size 23/0.193 mm size from ceiling rose to fitting including complete all as directed by Engineer-in-Charge. | 50 | EACH | |
165 | 3.48 | Refixing of old but serviceable MCB SP obtained from Serial Item No. 3.06 of any size and suitable capacity complete all as specified and as directed. | 40 | EACH | |
166 | 3.49 | S&F of energy saving environmental friendly long life LED 20 Watt building security light made up of presure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP opening with driver compartment, IP-66 protection with other accessories and necessary electric connection with pre wired and necessary mounting arrangements and provision of 3 mtr 2.5 sq mm 3 core copper conductor cable multistranded from light fitting to over head line run through street light bracket and flexible pipe to connected to phase, neutral and running earth wire and making good connection with suitable connectors to overhead conductor of any description complete all as directed by Engineer- in-charge.\nMAKE : Havells Cat No ENDURAPEARLSL20WLED 757SASYTOPCMP or equivalent make of Philips / Surya. | 26 | EACH | |
167 | 3.5 | M&L for street light fittings bracket made out from GI pipe 40 mm bore, light grade 1.0 meter long bent to required shape and fixing to poles including supply and fixing of Flat iron clamp of size 50mm x 6 mm with Bolts and nuts of size M16 x 50mm including washer of suitable size as required duly painted with two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. | 26 | EACH | |
168 | 3.51 | S&F of heavy duty exhaust fan 300 mm sweep MS Body, 3 wing 1400 rpm, single phase 240 Volts copper wounds complete with all accessories as louvers shutters etc including making connection through 3 core PVC copper wire run through flexible pipe. Single phase type complete all as specified and as directed.\nMAKE : USHA/ Havells / Orient. | 104 | EACH | |
169 | 3.52 | S&F of polycabonate blade exhaust fan 250 mm sweep 5 blade, 50W, 1300 RPM single phase complete with all accessories including making connection through 3 core PVC copper wire run through flexible pipe, Single phase type complete all as specified and as directed.\nMAKE : Bajaj/ Anchor / Havells | 104 | EACH | |
170 | 3.53 | S&F of water heater geyser storage type, suitable for working on single phase 240 Volt AC supply, Capacity 25 Ltr, 5 star, 2KW with fixing nuts and bolts complete all as specified and directed by Engineer-in- charge. \nMAKE : Havells Cat No- GHWASESWH025 or equivalent in Usha / Racold /Bajaj /AO Smith-Jaquar. | 104 | EACH | |
171 | 3.54 | S&F of Energy Efficient (BLDC) ceiling fan, 5 Star rated, AC 230 Volts single phase 1200 mm sweep, 26 Watt, with three blades complete with all accessories including MS Hook, Nuts, Bolts and washer for hanging arrangement complete all as specified and directed. Cat No. Efficiencia Neo (BLDC 26W) \nMAKE : Usha / Bajaj / Crompton / Havells. | 104 | EACH | |
172 | 3.55 | Sub total |