Repair/Maintenance Of Central And Package Type Ac Plant And Summer Cooling Appliances With Allied Works At Af Stn Bkt, GE (AF) BKT-Uttar Pradesh

Military Engineer Services-MES has published Repair/Maintenance Of Central And Package Type Ac Plant And Summer Cooling Appliances With Allied Works At Af Stn Bkt. Submission Date for this Tender is 01-07-2020. Air Conditioner Tenders in GE (AF) BKT Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

24510094
Corrigendum : Repair/Maintenance Of Central And Package Type Ac Plant And Summer Cooling Appliances With Allied Works At Af Stn Bkt
Open Tender
Indian
Uttar Pradesh
GE (AF) BKT
01-07-2020

Tender Details

Repair/Maintenance Of Central And Package Type Ac Plant And Summer Cooling Appliances With Allied Works At Af Stn Bkt

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Jun-2020 Amendment in tender documents Technical Bid 24-06-2020
2 24-Jun-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-07-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 46560.0 /-
Tender Value
INR 23.28 Lakhs /-

BOQ Items

Name of Work: Repair/Maintenance of central and package type AC plant with allied works and summer cooling appliances with allied works at AF STN BKT
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Material and labour for de-scaling and cleaning of chocked pipe water circulating lines including service valves, condenser (heat Exchanger) to cooling tower, circulating concentrated descaling solution (concentrated hydrochloric acid) mixed with water in suitable proportion till the complete deposits/scale is removed as ordered, circulating through pump, servicing of valves, cooling tower, water spray assembly, cleaning with suitable size of drill rod, wire brush including dismantling and connecting all dismantled components in proper position after servicing/overhauling/greasing etc replacement of packing gasket 3mm thick, nuts, bolts with washer, testing of water line for leakage, complete all as specified and directed by Engineer-in-Charge for 3 x 11TR capacity package plant. 2 Each\nJob
2 2 Ditto same as item No 1 here in before but Central AC Plant of capacity 2X 11 TR complete all as specified and directed 2 Each\nJob
3 3 Ditto same as item No 1 here in before but Central AC Plant of capacity 3X 37 TR complete all as specified and directed 2 Each\nJob
4 4 Ditto same as item No 1 here in before but Central AC Plant of capacity 3X 25 TR complete all as specified and directed 2 Each\nJob
5 5 M&L for servicing /maintenance /repair, testing and commission of open type reciprocating compressor 25 ton capacity including dismantling and disconnecting suction and discharge refrigerant lines, other controls and accessories, replacement /renewal of minor items but essentially required for completion of the job e.g gasket kits, cut washers, valve springs, castle nuts, suction rid, discharge rid,Lubricant oil, strainer,loading unloading setting,Shaft seal assembly etc and re-assembling in its position, complete all as specified and directed.\n 2 Each job
6 6 M&L for grinding, facing and polishing of cylinder head including supply only main and big end bearing of size to match with the crank shaft with connecting rod bush, piston lock, piston pin, complete all as specified and directed by Engineer-In-Charge. for compressor 25 Ton capacity. 1 Each Job
7 7 Supply & fix oil stainer assembly for item no 5 here in before complete testing complete all as specified and aproved by engr-in-charge 1 Each
8 8 M&L for reparing of oil pump including replacement of wornout parts i.e. Neoprene `O` ring, coupling with pin and lock, bushes etc except gears for compressor 25 Ton capacity complete all as specified and directed. 1 Each Job
9 9 M&L for replacement of compressor oil for 3X25 TR AC Plant complete all as specified and directed. 60 litre
10 10 Disconnecting and taking out existing defective compressor of any description and in any position and supplying and fixing new Refrigeration scroll compressor 5.5 TR capacity, three phase, 415 volt capacity including brazing to suction & discharge line, vacuum testing with and including charging of regrigerant gas (R-22) & testing complete all as specified and directed . (Make- Model ZR72KC-TFD-522 of make Copeland or equivalent make and model of KCL/Emersion/Danfoss 1 Each
11 11 M&L for charging of refrigerant gas (R-22) in AC plants with provision of all T&P as required at site complete all as specified and directed by Engineer-in-Charge. 130 Kg
12 12 M&L for charging of refrigerant gas (R407 ) in AC plants with provision of all T&P as required at site complete all as specified and directed by Engineer-in-Charge. 120 Kg
13 13 M&L for replacement of V fan belt A-28 Make : Fenner / Hilton/DUNLOP or equivalent complete all as specified and approved by Engineer-in-Charge. 6 Each
14 14 M&L for replacement of V fan belt A-32 Make : Fenner / Hilton/DUNLOP or equivalent complete all as specified and approved by Engineer-in-Charge. 6 Each
15 15 M&L for replacement of V fan belt B-84 Make : Fenner / Hilton/DUNLOP or equivalent complete all as specified and approved by Engineer-in-Charge. 12 Each
16 16 Dismantling and taking out existing unserviceable pressure gauge of any description and in any position and Supplying and fixing Freon gas pressure gauge of range 0 - 150 PSI, 100 mm dia complete all as specified & approved by Engineer-in-Charge. Make : Fibig / ACCEL / WAAREE / WIKA / MAHAVEER 2 Each
17 17 Dismantling and taking out existing unserviceable pressure gauge of any description and in any position and Supplying and fixing Freon gas pressure gauge of range 0 - 300 PSI, 100 mm dia complete all as specified & approved by Engineer-in-Charge. Make : Fibig / ACCEL / WAAREE / WIKA / MAHAVEER 2 Each
18 18 Disconnecting and removing existing unserviceable interconnecting wiring and connections of electric control panels of any description and in any position after through checking and inspections at site and material & labour for repairs of electric control panel & its complete interlocking system with using PVC insulated and unsheathed stranded copper conductor cable, single core,1.5 Sqmm size, 1100 Volts grade cable for making functional controls of the compressor, chilled water pump, condenser water pump, Air handling unit, cooling tower fan, LP/HP/Differential oil, pressure switch, solenoid valve, capacity control valve, thermostat, humidistat, heater, auxiliary contactor, push buttons, indicator, amps meter, volt meter complete as required at site for functioning of central AC plant, DX type / chilled water type, all as specified and directed by Engineer-in-Charge. \n(Note : \n(ii) The complete panel shall be checked and tested on full load after necessary repairs and replacement of unserviceable parts. for its smooth functioning and proper interlocking including tripping on single phasing\n(iii) Disconnecting, Taking down and replacement of defective/unserviceable parts/spares/ accessories with new one & its connection shall be measured and paid for separately under appropriate item of Schedule `A' here-in-after. 2 Each Job
19 19 M&L for replacement of micro processing device (MPD) suitable for 11 TR package type AC plant 230V 7-20Amps rating and testing complete all as specified & directed. Make- Softhard automation. Model No. - PMNMPD. 1 Each
20 20 M&L for repairs to water pump 5 HP capacity by replacement of bearing, impeller and rewinding of motor with super enamelled copper wire of existing gauge complete installation and testing complete all as specified and directed. 3 Each
21 21 M&L for repairs to water pump 2 HP capacity by replacement of bearing, impeller and rewinding of motor with super enamelled copper wire of existing gauge complete installation and testing complete all as specified and directed 2 Each
22 22 M&L for repairs to water pump 7.5 HP capacity by replacement of bearing, impeller and rewinding of motor with super enamelled copper wire of existing gauge complete installation and testing complete all as specified and directed 1 Each
23 23 M&L for repairs to Compressor motor 25 HP capacity by replacement of bearing, impeller and rewinding of motor with super enamelled copper wire of existing gauge complete installation and testing complete all as specified and directed 1 Each
24 24 M&L for repairs of UNSV Cooling tower motor assembly totally inclosed flange type including weather proof with extended saft specially designed for cooling Tower by replacement of bearing, impeller and rewinding of motor with super enamelled copper wire of existing gauge complete installation and testing complete all as specified and directed 1 Each
25 25 M&L for repairs to AHU blower motor 5 HP capacity by replacement of bearing, impeller and rewinding of motor with super enamelled copper wire of existing gauge including repair of shaft complete installation and testing complete all as specified and directed 1 Each
26 26 Supply and fixing differential oil failure switch type MP-55 complete all as specified and directed by Engineer-in-Charge. (Make : Indofoss / Renco / Pean) 3 Each
27 27 Supply and fixing LP control switch MP-15 complete all as specified and directed by Engineer-in-Charge.\n(Make : Indofoss / Renco / Pean ) 3 Each
28 28 Disconnecting and taking out old unserviceable contactor and Supply, fixing & testing new contactor of MNX 12 type, three pole power contactor with 01 NO + 01 NC auxiliary contacts for AC Circuit with AC coil voltage 220 grade, 50 Hz having current rating (AC3) of 12 Amps, 50 Cycle complete all as specified & approved by Engineer-in-Charge . Make : L&T or equivalent of Siemens / Control & switch gear. 3 Each
29 29 --ditto-- all as per item No 87 here in before type but MNX-18 with auxiliary contacts 1NO + 1NC having current rating (AC3) 18 Amps Make : L&T or equivalent of Siemens / Control & switch gear. 3 Each
30 30 --ditto-- all as per item No 87 here in before type but ML1.5 with auxiliary contacts 2NO + 2NC having current rating (AC3) 25 Amps Make : L&T or equivalent of Siemens / Control & switch gear. 3 Each
31 31 --ditto-- all as per item No 87 here in before type but ML2 with auxiliary contacts 2NO + 2NC having current rating (AC3) 32 Amps Make : L&T or equivalent of Siemens / Control & switch gear. 3 Each
32 32 --ditto-- all as per item No 87 here in before type but ML3 with auxiliary contacts 2NO + 2NC having current rating (AC3) 40 Amps Make : L&T or equivalent of Siemens / Control & switch gear. 3 Each
33 33 M & L for replacement of unserviceable thermal over load relay of various ranges as per existing make and model starting from 9 Amps to 42 Amps complete all as specified & approved by Engineer-in-Charge.Make : L&T / BCH or equivalent. 6 Each
34 34 M & L for replacement of unserviceable single phase preventer, auxiliary volts 415 volts, complete all as specified and approved by Engineer-in-Charge. 4 Each
35 35 M & L for replacement of unserviceable tongle switch complete all as specified & approved by Engineer-in-Charge. 4 Each
36 36 S&F Electronic timer suitable for capacity range 12 Amps to 40 amps for star delta startercomplete all as specified and approved by Engineer-in-Charge. Make : L&T / Havells or equivalent 4 Each
37 37 Disconnecting and taking out existing unserviceable solenoid valve and supply & fix new solenoid valve ¼ “ with strainer 3 way. Cat part No. S 180 with Drier of Make : SPORLON. or equivalent make as approved by the GE complete all as specified & directed. 2 Each
38 38 Disconnecting and taking out of existing unserviceable thermostatic expansion valve (R-22) of any description and in any position and supply and fixing and testing of new expansion valve conforming Make SPORLON ,equivalent complete all as specified and approved by engr-in-charge 1 Each
39 39 Disconnecting & Taking out old existing unserviceable MCCB and supply, fixing & testing MCCB, 160 Amps, 4 Pole, 415 Volts having breaking capacity Icu = ICS 100% = 25KA with adjustable thermal setting alongwith SS enclosure including mounting arrangement on wall or panel complete all as specified & directed. Make :Legrand /L&T/Control & Switch gear 1 Each
40 40 Disconnecting & Taking out old existing unserviceable MCCB and supply, fixing & testing MCCB, 100 Amps, 4 Pole, 415 Volts having breaking capacity Icu = ICS 100% = 25KA with adjustable thermal setting alongwith SS enclosure including mounting arrangement on wall or panel complete all as specified & directed. Make :Legrand /L&T/Control & Switch gear 1 Each
41 41 Disconnecting & Taking out old existing unserviceable MCCB and supply, fixing & testing MCCB, 63 Amps, 4 Pole, 415 Volts having breaking capacity Icu = ICS 100% = 16KA with adjustable thermal setting alongwith SS enclosure including mounting arrangement on wall or panel complete all as specified & directed. Make :Legrand /L&T/Control & Switch gear 2 Each
42 42 Disconnecting & Taking out old existing unserviceable MCB and supply, fixing & testing MCB, 32 Amps, 3 Pole, 415 Volts 50 HZ, 10 KA breaking capacity complete all as directed.Make :Legrand /L&T/Control & Switch gear 4 Each
43 43 Supply, fixing & testing Amp meter 0-40 / 50 / 60 /100 Amps, 96mm x 96mm, digital type complete all as specified & directed . Make : AE/ Rishab/Meco/Enercon. 5 Each
44 44 Supply, fixing & testing Volt meter 0-500 Volts, 96mm x 96mm, digital type with three way ON / OFF rotary type selector switch complete all as specified & directed . Make : L & T / AE. 2 Each
45 45 Dismantling and taking out existing unserviceable Temperature gauge (Thermometer) of any description and in any position and supplying & fixing new temperature gauge (Thermometer) suitable for condensing water circulating line, measuring range 0 - 50 oC complete all as specified & directed. Make : Japsine or superior make as approved by GE 4 Each
46 46 Dismantling and taking out existing unserviceable pressure gauge of any description and in any position and supplying & fixing new water pressure gauge of range 0 – 100 PSI, 100mm dia, complete all as specified & directed. Make : Fiebig / ACCEL/Guru/Jupiter or superior make as approved by GE 4 Each
47 47 Supply and Fixing Push Button Red/Green complete all as specified and approved by Engineer-in-Charge. 3 Each
48 48 Supply and Fixing Lamp holder Red/Green complete all as specified and approved by Engineer-in-Charge. 3 Each
49 49 M&L for Preparation of the existing decorated steel surfaces of existing panels of any description & in any position & applying two coats of synthetic enameled paint of approved shade complete including writing details & information on its panels with paints in the pattern & style to match with the words of existing panel complete all as specified & directed by Engineer-in-Charge. 2 Each job
50 50 M&L for Disconnecting, dismantling & Taking out existing old unserviceable temperature thermostat switch of any description & in any position including supply & fixing new differential temperature thermostat switch AC 230 Volts grade having range of 5 0C to 25 0C with sense capillary. complete all as specified and approved by Engineer-in-Charge Make : Renco / Pan / Honey well. 2 Each Job
51 51 M&L for Taking up or down cast iron butterfly valve of any description and supplying, fixing and testing new butterfly valve of 80 mm bore in existing pipe line after necessary cleaning etc. complete all as specified and directed :-( Make:- Castle/Zoloto/ Sant/Venus as approved by GE ) 2 Each
52 52 Taking up or down cast iron butterfly valve of any description and supplying, fixing and testing new butterfly valve of 50 mm bore in existing pipe line after necessary cleaning etc. complete all as specified and directed :-( Make:- Castle/Zoloto/ Sant/Venus as approved by GE ) 2 Each
53 53 Taking up or down cast iron butterfly valve of any description and supplying, fixing and testing new butterfly valve of 25 mm bore in existing pipe line after necessary cleaning etc. complete all as specified and directed :-( Make:- Castle/Zoloto/ Sant/Venus as approved by GE ) 2 Each
54 54 M&L for replacement of PVC filling blocks of size 600mmx300mmx150mm complete all as specified and directed Make: - MIHIR/SUVIDHA/ AVIRATS 60 Each
55 55 M&L for Disconnecting and taking out existing unserviceable strip heater of any description and in any position and Supply, fixing and connecting strip heater of 2 KW/3 KW, 230 volts fin type complete all as specified and directed Make : Daspas or equivalent make as approved by the GE. 10 Each
56 56 S&F glow sign board of central AC plantsize 3000x800x150 mm weather proof made of MS angle 50x50x6mmwith white acrylic sheet 2 mmthick and writing with arial black font with suitable size not exceeding 150 mm and maximum size 100 mm and provision of 04 nos of tubelight 1x36 watt with electronic ballast and other accessories and grouting on floor/roof with suitable primary and secondary support complete all as specified and directed by Engr-in -charge. 1 Each
57 57 M&L for Preparing old painted steel and metal based surfaces such as Compressor, AHU’s refrigerant water piping base plates, motors, AHU’s cable duct, MS channel, make up water tank, cooling tower, condensors, condensor pipe lines, etc of any shape, size and description, removing oil, dust & rust by using sand paper or any method on all types of surfaces, filling cavities if any and applying one coat spray painting with synthetic enameled paint of approved quality (All as per E-in-C’s colour code) with and including writing E/M & MES Nos, marking arrows / feeders name neatly on each machine complete of AC Plant of size 2 X 11 TR complete all as specified and directed by Engineer-in-Charge 1 Each job
58 58 M&L for Preparing old painted steel and metal based surfaces such as Compressor, AHU’s refrigerant water piping base plates, motors, AHU’s cable duct, MS channel, make up water tank, cooling tower, condensors, condensor pipe lines, etc of any shape, size and description, removing oil, dust & rust by using sand paper or any method on all types of surfaces, filling cavities if any and applying one coat spray painting with synthetic enameled paint of approved quality (All as per E-in-C’s colour code) with and including writing E/M & MES Nos, marking arrows / feeders name neatly on each machine complete of AC Plant of size 3 X 25 TR complete all as specified and directed by Engineer-in-Charge 1 Each job
59 59 M&L for Preparing old painted steel and metal based surfaces of Package type AC of capacity 3 X 11 TR including Package units, motors, pumps,cable duct, MS channel, make up water tank, cooling tower, condensors, condensor pipe lines, etc of any shape, size and description, removing oil, dust & rust by using sand paper or any method on all types of surfaces, filling cavities if any and applying one coat spray painting with synthetic enameled paint of approved quality (All as per E-in-C’s colour code) with and including writing E/M & MES Nos, marking arrows / feeders name neatly on each machine complete all as specified and directed by Engineer-in-Charge. 1 Each job
60 60 Disconnecting, cutting and taking out unserviceable sealed unit compressor of window type Air conditioner 1.5 Ton capacity any make & model and supply and fixing company new compressor of same make as existing for window type air condition 1.5 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed by the Engr-in-Charge 1 Each
61 61 Disconnecting, cutting and taking out unserviceable sealed unit compressor of split type Air conditioner 1.5 Ton capacity any make & model and supply and fixing company new compressor of same make as existing for split type air condition 1.5 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed by the Engr-in-Charge 7 Each
62 62 Disconnecting, cutting and taking out unserviceable sealed unit compressor of split type Air conditioner 2 Ton capacity any make & model and supply and fixing company new compressor of same make as existing for split type air condition 2 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed by the Engr-in-Charge 10 Each
63 63 Disconnecting, cutting and taking out unserviceable sealed unit compressor of water cooler storage type 40 - 80 Ltrs/ 60-120 Ltrs capacity any make & model and supply and fixing compressor of same make for water cooler storage type 40 - 80 Ltrs/ 60-120 Ltrs capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections and water connection, installations of water cooler at site and testing on load complete all as specified and directed by the Engr-in-Charge 2 Each
64 64 Disconnecting, cutting and taking out unserviceable sealed unit compressor of water cooler storage type 120/150 Ltrs capacity any make & model and supply and fixing compressor of same make for water cooler storage type 120/150 Ltrs capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections and water connection, installations of water cooler at site and testing on load complete all as specified and directed by the Engr-in-Charge 2 Each
65 65 Disconnecting, cutting and taking out unserviceable sealed unit compressor of Refrigerator upto 195Ltrs capacity any make & model and supply and fixing company repaired compressor of same make for Refrigerator upto 195 Ltrs capacity soldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load complete all as specified and directed by the Engr-in-Charge 1 Each
66 66 Disconnecting, cutting and taking out unserviceable sealed unit compressor of Refrigerator above 195 Ltrs capacity any make & model and supply and fixing company repaired compressor of same make for Refrigerator above 195 Ltrs capacity soldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load complete all as specified and directed by the Engr-in-Charge item12 1 Each
67 66.1 Note for Item No 1 to 7 :- (i) Unit rate include transportation to site of work & back as applicable (ii) Cost of refrigeration gas & oil deemed to be included in the unit rates quoted by the contractor item13
68 67 S&f Indoor blower motor of Split type AC 1.5 Ton capacity any make with supper enameled copper winding fixing and testing on load complete all as specified and directed by Engineer-in-Charge 10 Each
69 68 S&f indoor blower motor of Split type AC 2Ton capacity any make with supper enameled copper winding fixing and testing on load complete all as specified and directed by Engineer-in-Charge 10 Each
70 69 S&f blower motor of Water Cooler any capacity any make with supper enameled copper winding fixing and testing on load complete all as specified and directed by Engineer-in-Charge 4 Each
71 70 Re-winding of blower motor of desert cooler any capacity any make with supper enameled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including replacement GM bushes/bearing, fixing and testing on load complete all as specified and directed by Engineer-in-Charge 10 Each
72 71 Starting capacitor 80-100 mfd for window/Split type room air conditioner 1.5/2 Ton capacity including taking out the old unserviceable capacitor complete all as specified and directed by Engineer-in-Charge\nMake : Epcos/Havells /Usha/ Tipcon 55 Each
73 72 Starting capacitor 100-120 mfd for window/Split type room air conditioner 1.5 /2 Ton capacity including taking out the old unserviceable capacitor complete all as specified and directed by Engineer-in-Charge\nMake : Epcos/Havells /Usha/ Tipcon 50 Each
74 73 All as per Item No 13 here-in-before but 4 mfd 50 Each
75 74 All as per Item No 13 here-in-before but 6 mfd 50 Each
76 75 Running capacitor 10 mfd for water cooler including taking out the old unserviceable capacitor complete all as specified and didfrected by Engineer-in-Charge \nMake : Epcos/Havells /Usha/ Tipcon 15 Each
77 76 All as per Item No 16 here-in-before but 20 mfd 15 Each
78 77 All as per Item No 16 here-in-before but 36 mfd 20 Each
79 78 All as per Item No 16 here-in-before but 45 mfd 25 Each
80 79 All as per Item No 16 here-in-before but 50+6 mfd 45 Each
81 80 All as per Item No 16 here-in-before but 55+6 mfd 45 Each
82 81 Starting relay for 1.5 Ton window type AC including taking out the old unserviceable relay complete all as specified and directed by Engineer-in-Charge\nMake : Renutrol/indfoss 2 Each
83 82 All as per Item No 22 here-in-before but for split type AC 35 Each
84 83 All as per Item No 22 here-in-before but for water cooler 3 Each
85 84 All as per Item No 22 here-in-before but for Refrigerator 2 Each
86 85 Thermostatic switches for any capacity for window/split type AC including taking out the old unserviceable switches complete all as specified and directed by Engineer-in-Charge Make : Renutrol/Indfoss 15 Each
87 86 Thermostatic switches for any capacity for Water cooler including taking out the old unserviceable switches complete all as specified and directed by Engineer-in-Charge Make : Renutrol/Indfoss 2 Each
88 87 Thermostatic switches for any capacity for Refrigerator including taking out the old unserviceable switches complete all as specified and directed by Engineer-in-Charge Make : Renutrol/Indfoss 2 Each
89 88 MS front bottom panel of water cooler duly spray painted to match with the existing water cooler including dismantling/taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge 4 Each
90 89 Chromium plated drip tray assembly of water cooler complete with elbow including dismantling/taking out the old unserviceable drip tray complete all as specified and directed by Engineer-in-Charge 5 Each
91 90 Hose pipe 20 mm dia synthetic PVC rubber corrugated of standard length for wadter cooler complete with two clamps (worm gear type) one on each side including dismantling the old unserviceable hose pipe complete all as specified and directed by Engineer-in-Charge 6 Each
92 91 20 mm dia PVC pipe cotton bralded for water cooler connection complete all as specified and directed by Engineer-in-Charge 6 Each
93 92 15 mm dia PVC (heavy duty) pipe for desert cooler complete all as specified and directed by Engineer-in-Charge 100 RM
94 93 20 mm dia MS clamp (worm gear type) for PVC pipe including dismantling the old unserviceable clamp complete all as specified and directed by Engineer-in-Charge 25 Each
95 94 Blower motor 230 Volts, AC 50 Hz single phase complete with blower fan for window type room air conditioner 1.5 Ton capacity of existing make and size including taking out the old unserviceable motor complete all as specified and directed by Engineer-in-Charge \nMake : AUE/Universal/Khatain/Bajaj 1 Each
96 95 All as per Item No 35 above here-in-before but out door unit split type AC 16 Each
97 96 All as per Item No 35 above here-in-before but Water cooler 3 Each
98 97 All as per Item No 35 above here-in-before but Desert cooler 3 speed 20 Each
99 98 Replace/in repair Circuit board PCB of Split Type AC complete for 1.5/2.0 TR Split type A/C and complete testing as per directed 10 Each
100 99 Repair and maintenance of Circuit board PCB complete for 1.5/2.0 TR Split type A/C and complete testing as per directed 15 Each
101 100 S&F Indoor unit of split type AC capacity 1.5 TR including evaporator coil ,blower ,blower motor,controling circuit of AC complete all as specified and directed by Engr-in Charge.\nMake- LG,Carrier ,Daikin ,Samsung 1 Each
102 101 All as per Item No 41 here-in-before but for Capacity 2.0 TR 1 Each
103 102 Blower fan blade complete for desert cooler all as specified and directed by Engineer-in-Charge \nMake : AUE/Universal/Khaitan/Bajaj 20 Each
104 103 Cable PVC insulated sheathed 3 core copper conductor size 40/0.0076 mm including taking out the old unservidceable conductor complete all as specified and directed by Engineer-in-Charge 90 RM
105 104 Push cock press push type MS chromium plated suitable for 15 mm bore pipe for water cooler including dismantling the old unserviceable push cock complete all as specified and directed by Engineer-in-Charge 4 Each
106 105 Maintenance, servicing cleaning of window type room air conditioner 1.5 Ton capacity at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switches condensor motor, blower/condensor fan rectification of fault, connecting and testing on load. Replacement of spare or gas shall be measured and paid separely under respective item 10 Each
107 106 Maintenance, servicing cleaning of split type air conditioner 1.5/2 Ton capacity at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switches condensor motor, blower/condensor fan rectification of fault, connecting and testing on load. Replacement of spare or gas shall be measured and paid separely under respective item 250 Each
108 107 Regulating knobs of window type room air conditioner including dismantling the old unserviceable knobs complete all as specified and directed by Engineer-in-Charge 2 Each
109 108 Maintenance, servicing & repair of refrigerator 170/195 ltrs capacity any make model cleaning the various components and replacement i. e Chill tray, Shelves, Freezer door, Door Gasket, Door Lock, Blub Holder & bulb and Food tray complete all as specified and directed by Engineer-in-Charge \n 6 Each Job
110 109 Maintenance, servicing & repair of refrigerator 310/345 ltrs capacity any make model cleaning the various components and replacement i. e Chill tray, Shelves, Freezer door, Door Gasket, Door Lock, Blub Holder & bulb and Food tray complete all as specified and directed by Engineer-in-Charge \n 8 Each Job
111 110 Defrost timer for domestic refrigerator including dismantling the old unserviceable timer all as sample and directed by Engineer-in-Charge Make : Samsung/Godrej/Whirpool 2 Each
112 111 All as per Item No 50 here-in-before but Bimetal relay 2 Each
113 112 All as per Item No 50 here-in-before but Defrost heater 2 Each
114 113 All as per Item No 50 here-in-before but Fan motor assy alongwith fan blade 2 Each
115 114 All as per Item No 50 here-in-before but over load proection for refrigerator 2 Each
116 115 All as per Item No 50 here-in-before but PTC relay 2 Each
117 116 Condenser line filter for window/split AC complete all as specified and directed by Engineer-in-Charge 20 Each
118 117 Condenser line filter for Refrigerator complete all as specified and directed by Engineer-in-Charge 2 Each
119 118 Condenser line filter for Water cooler complete all as specified and directed by Engineer-in-Charge 5 Each
120 119 Maintenance & servicing of water cooler 40/80 ltrs,60/120 & 120/150 Ltrs at site cleaning the equipment, checking wiring , running and starting capacitor, thermostatic switch condensor motor, blower fan, rectification of fault replacement of spare and charging of gas as on required basis, connecting & testing on load for performance all as directed by Engineer-In-Charge \nNote : Spare and gas shall be measured and paid separately\n 30 Each Job
121 120 Spray painting to water cooler 40/80 Ltrs & 120/150 Ltrs with one coat of synthetic enamel paint (colour as per original shade) including writing of SM No over the body with white/black paint all as per specified and directed by Engineer-in-Charge 5 Each Job
122 121 Taking out the existing rusted/worn out base plate of water cooler 40/80 ltrs & 120/150 Ltrs capacity by disconnecting the compressor, condenser motor, providing new MS base plate including welding work and straightening of base plate & re-fixing the compressor, condensor & condenser motor making all connection, charging gas and testing on load all as specified and directed by Engineer-in-Charge 5 Each
123 122 Grill of window type room air conditioner 1.5 ton capacity suitable for any make & model as existing at site including dismantling old grill complete all as specified and directed by Engineer-in-Charge 1 Each
124 123 Servicing and painting of desert cooler installed at site, cleaning the equipment with air blower fan and wiping , dry and wet cleaning of body and louver, preparations surface with soft wire brush and painting the cooler with one coat of synthetic enamel paint checking the control wiring, fan & motor, tullu pump and replacement of the following plastic part of tullu pump and cooler body and oiling the pump & motor complete \n(a) Wiper (b) Plastic impeller of tullu pump with enclosure (c) Distributor 125 Each Job
125 124 Cutting, disconnecting & taking out the condensing unit of split type room air conditioner 1.5 Ton capacity and providing the new condensing unit of exsting size model in place including welding, brazing etc and tdesting on load all as specified and directed by Engineer-in-Charge 4 Each Job
126 125 All as per item No 65 here-in-before but evaporator coil 4 Each
127 126 All as per item No 65 here-in-before but water cooler 2 Each
128 127 Spray painting of window type AC 1.5 Ton capacity including preparation of old surfaces and applying one coat of synthetic enamel paint (colour as per original shade ) including writing of SM No over the body with white/black paint all as directed by the Engineer-in-Charge 4 Each Job
129 128 Replace air filter suitable for window type AC 1.5 Ton capacity all as per sample and directed by Engineer-in-Charge 2 Each
130 129 All as per Item No 69 here-in-before but for split type AC 50 Each
131 130 Supply only Submersible pump for desert cooler (in replacement) for lifting water upto 1.2 meter head. Make : Champian/Crompton Graves/Meghdoot/Usha. 75 Each
132 131 Wood wool pad set suitable for desert cooler heavyy duty including dismantling the old unserviceable wood wool pad set all as directed by Engineer-in-Charge 125 Each set of three
133 132 Re-winding of main transformer of voltage stabilizer capacity 5 KVA with super enameled copper winding wire of suitable gauge including making connection by soldering and testing complefte all as directed by Engineer-in-Charge 20 Each
134 133 All as per Item No 73 here-in-before but 4 KVA 15 Each
135 134 Relay for voltage stabilizer 240 volts all as per sample and required at site including dismantling the old unserviceable relay 20 Each
136 135 Volt meter 0-300 volts fixed as in repair 10 Each
137 136 Amps meter 0-30 Amp fixed in repair 10 Each
138 137 Timer circuit for voltage stabilizer including dismantling the old unserviceable timer circuit all as per sample and required at site complete all as specified and directed by Engineer-in-Charge 20 Each
139 138 Connector porcelain type for voltage stabilizer including dismantling the old unserviceable porcelain complete all as specified and directed by Engineer-in-Charge 20 Each
140 139 Float valve with PVC float ball brass stem & fly nut complete with screwed for iron pipe 15 mm bore fixed in repairs complete all as specified and directed by Engineer-in-Charge 25 Each
141 140 Gun metal gate valve with iron wheel head screwed both ends for iron pipe 15 mm dia fixed in repairs complete all as specified and directed by Engineer-in-Charge \nMake : Neta/Leader/Bir 25 Each
142 141 15 mm dia PVC connection to water coolers 450 mm long fixed in repair complete all as specified and directed by Engineer-in-Charge 20 Each
143 142 Gi nipple 15 mm dia 150 mm long fixed in repair complete all as specified and directed by Engineer-in-Charge 5 Each
144 143 15 mm bore GI tubing medium grade fixed in repair complete all as specified and directed by Engineer-in-Charge 100 RM
145 144 GI Union 15 mm dia fixed in repairs 30 Each
146 145 GI Socket 15 mm dia fixed in repairs 30 Each
147 146 Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Mettalic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete fixed as in repairs complete all as specified and directed by Engineer-in-Charge Make Havells/MDS/Legrand 10 Each
148 147 Taking down unserviceable split AC and re-fixed to its original position after repairing including welding and brazing of copper pipe complete all as specified and directed by Engineer-in-Charge \nNote : Filling of gas shall be measured be paid for separately 15 Each
149 148 Supply and fixing of Copper Pipe size 5/8"( with sleeves)including welding brazing of copper pipe 50 RM
150 149 Supply and fixing of Copper Pipe size 1/4"( with sleeves)including welding brazing of copper pipe 50 RM
151 150 Supply and fixing of Copper Pipe size 1/2"( with sleeves)including welding brazing of copper pipe 40 RM
152 151 Supply and fixing of Copper Pipe size 3/8"( with sleeves)including welding brazing of copper pipe 40 RM
153 152 Ditto all as per item No 06 here in before but insulation for cooper tube of size 1/4" or 1/2" or 3/8" or 5/8" dia for cooling unit to condensing unit for split AC complete all as specified and directed by Engr-In-Charge. 300 RM
154 153 Supply and fixing of selector switch combination of 4 switches(for low,med,high & pump on/off) for desert Cooler as per sample complete with connection all as specified and directed 25 Each
155 154 Supply and fixing of Blower assembly for split type AC any capacity 5 Each
156 155 Supply and fixing of condenser fan suitable for Window type AC any capacity 1 Each
157 156 Supply and fixing of condenser Fan Suitable for Split Type AC any capacity 10 Each
158 157 Supply and fixing of Top Plug 3 pin 220 Volt 5 Amp Make :- Anchor/Plaza/Havells 50 Each
159 158 Supply and fixing of Top Plug 3 pin 220 Volt 15 Amp Make :- Anchor/Plaza/Havells 50 Each
160 159 S&F Industrial protected socket with cap and chain 3 pin 240 volt 20 Amp Make :-Anchor/Plaza/Havells 10 Each
161 160 S&F Industrial protected plug top 3 pin 240 volt 20 Amp Make :-Anchor/Plaza/Havells 20 Each
162 161 Supply and fix blower for split AC 1.5 Ton capacity for indoor unit 5 Each
163 162 Supply and fix blower for split AC 2 Ton capacity for indoor unit 5 Each
164 163 M&L for repair to remote circuit complete with remote device for 1.5/2 TR window/split type AC and complete testing as per directed 15 Each
165 164 S&F in repair MCB protected socket combination including MCB of capacity 25 amps withsteel sheet/plastic enclosure with plug topAC 230 V complete all as specified and directed 15 Each
166 165 S&F in repair MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed. 20 Each
167 166 Cable PVC insulated sheathed 3 core copper conductor size 70/0.0076 mm including taking out the old unservidceable conductor complete all as specified and directed by Engineer-in-Charge 90 RM
168 167 Cable PVC insulated sheathed 3 core copper conductor size 110/0.0076mm including taking out the old unservidceable conductor complete all as specified and directed by Engineer-in-Charge 90 RM
169 168 M&L for charging of refrigerant gas (R-22 /32/ 134 (a) / 410 c ) in split/window type AC after detecting leakage test with CO2 gas with provision of all T&P as required at site complete all as specified and directed by Engineer-in-Charge. 45 Each Job
170 169 All as per item no. 109 here in before but for water cooler 5 Each Job
171 170 All as per item no. 109 here in before but for refrigerator 3 Each Job