Annual Repair And Maintenance Of Of Electro And Mechanical Installations At B . M . Airport , Ranchi Sh Providing Maintenance Services For E And M Installations Of Operational Area And Technical Block For The Year 2020-2022, AAI,BM,Airport,Ranchi-Jharkhand

Airports Authority Of India has published Annual Repair And Maintenance Of Of Electro And Mechanical Installations At B . M . Airport , Ranchi Sh Providing Maintenance Services For E And M Installations Of Operational Area And Technical Block For The Year 2020-2022. Submission Date for this Tender is 15-06-2020. Electromechanical Services Tenders in AAI,BM,Airport,Ranchi Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

24503468
Annual Repair And Maintenance Of Of Electro And Mechanical Installations At B . M . Airport , Ranchi Sh Providing Maintenance Services For E And M Installations Of Operational Area And Technical Block For The Year 2020-2022
Open Tender
Indian
Jharkhand
AAI,BM,Airport,Ranchi
15-06-2020

Tender Details

Annual Repair And Maintenance Of Of Electro And Mechanical Installations At B . M . Airport , Ranchi Sh Providing Maintenance Services For E And M Installations Of Operational Area And Technical Block For The Year 2020-2022 , Sub Head - I Operation And Maintenance - Man Power Requirement . Providing Operation And Maintenance Services Of Electrical & Mechanical Installations Monthly At Entire Operational Area Includes Old & New Atc Cum Technical Block , Fire Station , Navaids , Stp Building , Hangars ( For Availing Source Of Power Supply Only ) Comprising Glf Systems , Ccrs , 03 Nos . Dg Sets Upto 500 Kva With Amf Panels , Power Supply Distribution Systems , Transformers Upto 630 Kva , Water Pump Sets , Lifts , High Mast Towers , Flood Lights , Street Lights , Perimeter Road Lights , Fire Hydrant System ( Only Operations ) , Hvac-Vrv System ( Only Operations ) All Internal & External E . I . Works , Old & New Atc Power Houses , Fire Station , I / C 33 Kv Ht Panel , All Lt Panels & Feeder Pillars , Apfc Panel , Alcms , Upss ( 2 Nos X80 Kva And 2 Nos X180 Kva ) Including Other Minor Ancillary & Related Installations Covering The Scope Of Operations , Repairs & Maintenance , Attending Faults / Breakdowns Rectifications , Ensuring Serviceability / Satifactory Working Condition Of The Systems , Preventive Maintenance On Daily / Weekly / Monthly / Quarterly / Half Yearly / Yearly Basis , Maintenance Of Records / Documentation Etc . As Per Scope Of Work Given In Special Conditions And Technical Specifications Of Contract On All Days Including Sundays & Holidays . The Services Of Dg Sets , Amf Panels At Power Houses And The Services Of All Other E & M Installations Shall Be Ensured Round The Clock ( Ie . In Three Shifts Daily , Each Shift Of 8 Hours ) As Per Specification And As Required . ( Minimum Manpower Engaged Shall Be As Per Special Condition Of Contract And Particular Specification Of Contracts ) , Ist Year , Ii Nd Year , Sub Head - 2 Miscellanious Seruices Testing Bdv Value Of Transformer Oil In Presence Of Aai Representative , Ist Year , Ii Nd Year , Dehyderation And Filtration Of Transformer Oil At Site Including Testing For Bdv Value After Dehydration And Filtration And Submission Of Test Reports Etc . Complete As Required . , Ist Year , Ii Nd Year , Servicing , Maintenance And Testing Of L & T Make Air Circuit Breaker Up Tol000a Complete As Required . , Ist Year , Ii Nd Year , Servrcing , Maintenance And Calibration Of Earth Fault And Over Load Relay With Secondary Injection Kit Etc . Of 02 Nos . Ht Panel Of Jyoti Make Comdlete As Required . , Ist Year , Ii Nd Year , Servicing , Maintenance And Testing Of 33 Kv Ht - Vaccum Circuit Breaker Ofjyoti Make Etc . Complete As Required . , Ist Year , Ii Nd Year , Repair And Rewinding Of Submersible Pump Motor Upto 5 Hp Job Includes Transportation Of Motor , Dismantling And Rewinding With The Same Gauge Insulated Copper Wire Including Replacement Of All The Internal Worn-Out / Defective Parts I . E . Bushes , Impellers , Sleeves , Upper And Lower Bush Sets , Thrust Bearings , Oil Seals , Rotor Grinding And Balancing , Assembling , Testing , Transportation Etc . Complete As Required . , Lifting And Lowering Of Submersible Pumps Of Various Capacities ( Upto 5 Hp ) Due To Defect In Existing Pump On Urgent Basis Within A Short Notice Including Connection Of Cable , Jointing Of Cable Etc With Successful Testing & Commissioning Complete As Required . , Repair And Overhauling Of Amf Panels I / C Checking Of Control Circuits , Interlocking , Checking Of Healthiness Of All Components Including Amf Relays Etc As Complete And As Per Direction Of Eic ( Faulty Spares To Be Provided By Aai ) , Sub Head - 3 Supply Of General Electrical Materials As And When Required . Supply Of Flame Retardant Low Smoke & Halogen Fr-Lsh Pvc Insulated Industrial Cables Of Following Sizes Single Core Fr-Lsh Pvc Insulated Industrial Grade Copper Conductor ( Unsheathed ) Flexible Cables , 1100 Volts Conforming To Is: 694 ( Each Roll Of 90 Mtrs ) , I Core 1 . 5 Sq . Mm . , I Core2 . 5 Sq . Mm . , I Core 4 Sq . Mm . , Supply Of Pvc Insulated And Fr Pvc Round Sheathed , Copper Conductor ( Flexible ) Industrial Cable , 1100 Volts , Conforming To Is: 694 ( Each Roll Of 100 Mtrs ) , 3 Core 2 . 5 Sq . Mm . , 3 Core 4 Sq . Mm . , Supply Of 90 W Led Street Light Fittings Cool White , Supply Of 3Hp Submersible Pump Set Make Ksb , Model Umai 100- 2 . 2122 Or Equivalent , Supply Of Wll Mounted Fans 300 Mm Sweep , Supply Of Medium Intensity Aviation Obstruction Light For 230 V System , Supply Of Following Size Xlpe Insulated And Pvc Sheatheed , Armoured Aluminum Conductor Power Cable Of 1 . 1 Kv Grade Conforming To Is-7098 ( Part-1 ) 1988 With Upto Date Amendments . 3 . 5 X 185Sq Mm , 12V Constant Voltage Converter Drive For Led Signages 60W , 12V Constant Voltage Converter Drive For Led Signages 120W , Led Strip 0 . 2W X 144 Per Strip Of I Meter , Sh:4 Supply Of Airfield Materials I / C Glf Supply Of Following Glf Items As Per Latest Icao Specifications , 200W 6 . 6 A Holagen Lamp Runway Lamp , 105 W 6 . 6 A Bipin ( Inset ) Halogen Lamp , 200 W 6 . 6 A Elevated Approach Fiting Lamp , Runway Larnp Holder ( Flate End Tenninal ) , 6 Sq . Mm Essna -Kit ( Copper ) 5Kv Grade , 16 Sq . Mm 5 Kv Grade Plug &Recaptable ( Essna Kit ) ( Copper ) , Secondary 2 Pin Lead Of 0 . 3 Mtr Length , Two Pin Secondary Plug Assembly For Papi ( 2 . 5 Mtr Long ) , Base Plate Gaskets , Led Signage Converter Capable To Drive Led Strip Of 05W For Ooerational Area Signages , Led Signage Strip Of 0 . 5W Make Osram Or Equivalent , Led Type Taxi Fitting As Per Latest Icao Standards , Breakable Coupling For Glf Light Fittings , Supply Of Scr / Thyrister For Nasu Ccr , 85 Rk 160 Scr / Thyrister For 7 . 5Kw Nasu Make Ccr , 250Rk 160 Scr / Thyristor For 30Kw Nasu Make Ccr , Supply Of Isolating Transformer As Per Icao , Isolating Transformer200w 20 / 6 . 6 A , Isolating Transformer200w 6 . 6 / 6 . 6 A , Isolating Transformer 45W 20 / 6 . 6 A , Isolating Transformer 45W 6 . 6 / 6 . 6 A , Isolating Transformer 15 W 20 / 6 . 6A , Isolating Transformer 15 W 6 . 6 / 6 . 6A , Isolating Transformer 300W 6 . 6 / 6 . 6A , Supply Of Lens , 360 Clear Inner Lens / Filters , 180 Deg Inner Lens Filters , 180 Deg Red Lens Filters , 180 Deg Green Lens Filters , 180 Deg Yellow Lens / Filter , Ommi- Directionol Blue Lens Suitable For Mirl , 180 Deg Black Sheild , 180 Yellow Filter ( Convetional Type ) , Red Filter For Papi , Red Spreader Lens For End Light Fiting , Green Spreader Lens For Threshold Light Fiting , 360 Clear Outer Dome For Hirl Fitring , Supply Of Airfield / Runway Cable , 1X6 Sq . Mm Airfiled Lieilrting Cable , 1X16 Sq . Mm Airfiled Lieilrting Cable , Sub Head - 5 Dsr Works Percentage Above Or Below On The Rates Of Dsr2018 ( Cpwd ) -Electrical Items Worth Totaling To Rs . 15 , 00 , 000 . 00 As Per Requirement . ( Note: The Firm Has To Quote / Upload The Percentage Above / Below ( + / - % ) On The Quantity Mentioned Against This Item Directly In The Form Of Multiplying Factor In The Rate Coloumn As Clarified Below: For Example: If Desired To Quote 5% Above On Sr-2018 Rates , The Rate Column Shall Be Filled As 1 . 05 . If Desired To Quote 3% Below On Sr-2018 Rates , The Rate Column Shall Be Filled As 0 . 97 . )

Key Value

Document Fees
INR 1180 /-
EMD
INR 454386.0 /-
Tender Value
INR 2.27 Crore /-

BOQ Items

Name of Work: : ARMO E & M Installations at B. M. Airport, Ranchi. SH: Providing Maintenance Services for E&M Installations of Operational Area and Technical Block for the Year 2020-2022.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Sub Head - I Operation and Maintenance - Man power\nRequirement.\n\nProviding Operation and Maintenance Services of Electrical & Mechanical Installations monthly at entire Operational Area includes Old & New ATC cum Technical Block, Fire station, Navaids, STP building, Hangars (For availing source of power supply only) comprising GLF Systems, CCRs, 03 nos. DG Sets upto 500 KVA with AMF Panels, Power Supply Distribution Systems, Transformers upto 630 KVA, Water Pump Sets, Lifts, High Mast Towers, Flood Lights, Street Lights, Perimeter Road Lights , Fire Hydrant System (only operations), HVAC-VRV system (only operations) all Internal & External E. I. works, Old & New ATC power houses, Fire station, i/c 33 KV HT panel, all LT panels & Feeder pillars, APFC panel, ALCMS, UPSs (2 nos x80 KVA and 2 nos x180 KVA) including other minor ancillary & related installations covering the scope of operations, repairs & maintenance, attending faults / breakdowns rectifications, ensuring serviceability / satifactory working condition of the systems, preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintenance of records/documentation etc. as per scope of work given in special conditions and technical specifications of contract on all days including Sundays & Holidays. The services of DG Sets, AMF Panels at power houses and the services of all other E & M installations shall be ensured round the clock (ie. in three shifts daily, each shift of 8 hours) as per specification and as required. (Minimum Manpower engaged shall be as per special condition of contract and particular specification of contracts) BI01010001010000000000000515BI0100001112
2 1.01 Ist Year BI01010001010000000000000515BI0100001113 12 Month
3 1.02 II nd Year BI01010001010000000000000515BI0100001114 12 Month
4 2 Sub Head - 2 Miscellanious seruices\n\nTesting BDV value of transformer oil in presence of AAI representative BI01010001010000000000000515BI0100001112
5 2.01 Ist Year BI01010001010000000000000515BI0100001121 5 each
6 2.02 II nd Year BI01010001010000000000000515BI0100001122 5 each
7 3 Dehyderation and filtration of transformer oil at site including testing for\nBDV value after dehydration and filtration and submission of test reports\netc. complete as required. BI01010001010000000000000515BI0100001112
8 3.01 Ist Year BI01010001010000000000000515BI0100001125 3000 ltrs
9 3.02 II nd Year BI01010001010000000000000515BI0100001126 3000 ltrs
10 4 Servicing, maintenance and testing of L & T make Air Circuit Breaker\nup tol000A complete as required. BI01010001010000000000000515BI0100001112
11 4.01 Ist Year BI01010001010000000000000515BI0100001127 10 each
12 4.02 II nd Year BI01010001010000000000000515BI0100001128 10 each
13 5 Servrcing, maintenance and calibration of earth fault and over load relay\nwith secondary injection kit etc. of 02 nos. HT panel of Jyoti make\ncomDlete as required. BI01010001010000000000000515BI0100001112
14 5.01 Ist Year BI01010001010000000000000515BI0100001127 2 each
15 5.02 II nd Year BI01010001010000000000000515BI0100001128 2 each
16 6 Servicing, maintenance and testing of 33 kV HT - Vaccum Circuit\nBreaker ofjyoti make etc. complete as required.\n BI01010001010000000000000515BI0100001112
17 6.01 Ist Year BI01010001010000000000000515BI0100001127 2 each
18 6.02 II nd Year BI01010001010000000000000515BI0100001128 2 each
19 7 Repair and rewinding of submersible pump motor upto 5 HP Job includes transportation of motor, dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn-out/ defective parts i.e. bushes, impellers, sleeves, upper and lower bush sets, thrust bearings, oil seals, rotor grinding and balancing , assembling, testing, transportation etc. complete as required. BI01010001010000000000000515BI0100001128 4 job
20 8 Lifting and lowering of submersible pumps of various capacities (upto 5 HP) due to defect in existing pump on urgent basis within a short notice including connection of cable, jointing of cable etc with successful testing & commissioning complete as required. BI01010001010000000000000515BI0100001128 4 job
21 9 Repair and overhauling of AMF panels i/c Checking of control circuits, interlocking , checking of healthiness of all components including AMF Relays etc as complete and as per direction of EIC(Faulty spares to be provided by AAI ) BI01010001010000000000000515BI0100001128 1 job
22 10 Sub Head - 3 Supply of general electrical Materials as and when\nrequired.\n\nSupply of Flame Retardant Low Smoke & Halogen FR-LSH PVC Insulated Industrial Cables of following sizes Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed)\nFlexible Cables, 1100 Volts Conforming to IS: 694 (Each Roll of 90 Mtrs) BI01010001010000000000000515BI0100001112
23 10.01 I Core 1.5 Sq. mm. BI01010001010000000000000515BI0100001127 15 roll
24 10.02 I core2.5 sq.mm. BI01010001010000000000000515BI0100001128 15 roll
25 10.03 I core 4 sq.mm. BI01010001010000000000000515BI0100001128 10 roll
26 11 Supply of PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 (Each Roll of 100 Mtrs) BI01010001010000000000000515BI0100001112
27 11.01 3 core 2.5 sq.mm. BI01010001010000000000000515BI0100001127 4 roll
28 11.02 3 core 4 sq.mm. BI01010001010000000000000515BI0100001128 4 roll
29 12 Supply of 90 W LED street Light fittings cool white 20 each
30 13 Supply of 3HP submersible pump set make KSB, model UMAI 100-\n2.2122 or equivalent 2 each
31 14 supply of wll mounted fans 300 mm sweep 10 each
32 15 supply of medium intensity Aviation obstruction light for 230 V system 5 each
33 16 Supply of following size XLPE insulated and PVC sheatheed, armoured Aluminum conductor power cable of 1.1 KV grade conforming to IS-7098 (part-1) 1988 with upto date amendments. 3.5 x 185sq mm 500 mtrs
34 17 12V constant voltage converter drive for LED signages 60W 10 each
35 18 12V constant voltage converter drive for LED signages 120W 10 each
36 19 LED strip 0.2W X 144 per strip of I meter 50 mtrs
37 20 SH:4 supply of Airfield materials i/c GLF\n\nSupply of following GLF items as per latest ICAO specifications BI01010001010000000000000515BI0100001112
38 20.01 200w 6.6 A holagen Lamp Runway lamp 200 each
39 20.02 105 w 6.6 A BIPIN (Inset ) Halogen Lamp 50 each
40 20.03 200 W 6.6 A Elevated Approach Fiting lamp 50 each
41 20.04 Runway Larnp Holder (Flate end tenninal ) 50 each
42 20.05 6 sq.mm ESSNA -kit (copper ) 5kv grade 50 each
43 20.06 16 sq.mm 5 KV Grade plug &Recaptable (ESSNA Kit)(copper) 100 each
44 20.07 Secondary 2 Pin lead of 0.3 mtr Length 50 each
45 20.08 Two Pin Secondary Plug Assembly for PAPI (2.5 Mtr long) 50 each
46 20.09 Base Plate Gaskets 50 each
47 20.1 LED Signage Converter capable to drive LED strip of 0'5w for\nooerational area signages 20 each
48 20.11 LED Signage Strip of 0.5w make osram or equivalent 50 each
49 20.12 LED Type Taxi Fitting as per latest ICAO standards 25 each
50 20.13 breakable coupling for GLF light fittings 20 each
51 21 Supply of SCR /Thyrister for NASU CCR BI01010001010000000000000515BI0100001112
52 21.01 85 RK 160 SCR/thyrister for 7.5kw NASU make CCR 4 each
53 21.02 250RK 160 SCR/thyristor for 30kw NASU make CCR 4 each
54 22 Supply of Isolating Transformer as per ICAO BI01010001010000000000000515BI0100001112
55 22.01 Isolating Transformer200w 20/6.6 A 50 each
56 22.02 Isolating Transformer200w 6.6/6.6 A 20 each
57 22.03 Isolating Transformer 45w 20/6.6 A 10 each
58 22.04 Isolating Transformer 45w 6.6/6.6 A 10 each
59 22.05 Isolating Transformer 15 w 20/6.6A 20 each
60 22.06 Isolating Transformer 15 w 6.6/6.6A 20 each
61 22.07 Isolating Transformer 300W 6.6/6.6A 10 each
62 23 Supply of LENS BI01010001010000000000000515BI0100001112
63 23.01 360 Clear inner lens /Filters 50 each
64 23.02 180 deg inner lens filters 10 each
65 23.03 180 deg Red lens filters 10 each
66 23.04 180 deg Green lens filters 10 each
67 23.05 180 deg yellow lens/filter 10 each
68 23.06 Ommi- directionol blue lens Suitable for MIRL 10 each
69 23.07 180 deg Black Sheild 10 each
70 23.08 180 Yellow Filter (convetional Type ) 10 each
71 23.09 Red Filter for papi 10 each
72 23.1 Red Spreader lens for end light fiting 10 each
73 23.11 Green Spreader lens For threshold light fiting 10 each
74 23.12 360 Clear outer dome for HIRL fitring 50 each
75 24 Supply of Airfield/Runway Cable BI01010001010000000000000515BI0100001112
76 24.01 1x6 sq.mm Airfiled Lieilrting cable 500 mtrs
77 24.02 1x16 sq.mm Airfiled Lieilrting cable 500 mtrs
78 25 Sub Head - 5 DSR Works\nPercentage above or below on the rates of DSR'2018(CPWD )-Electrical items worth totaling to Rs.15,00,000.00 as per requirement.\n(Note: The firm has to quote/upload the Percentage above/ below (+/- %) on the quantity mentioned against this item directly in the form of multiplying factor in the rate coloumn as clarified below:\nFor Example: If desired to quote 5% above on SR-2018 rates, the rate column shall be filled as 1.05. \nIf desired to quote 3% below on SR-2018 rates, the rate column shall be filled as 0.97.) 1.5e+06 % Above or Below
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail