Water Supply And Sanitation Department-WSSD has published Improved Access To Water Through Household Connections In Existing Water Supply Village Kalowal Block Chogawan And District Amritsar Under Prwssip 2A Ii Providing House Connection For Existing Pipe Line New Pipe Line Prov . Laying Jointing Testing Pvc P. Submission Date for this Tender is 20-07-2020. Water Supply Project Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 15-Jun-2020 | Corrigendum | Date | 24-06-2020 |
2 | 24-Jun-2020 | Corrigendum 1 | Date | 06-07-2020 |
3 | 06-Jul-2020 | Corrigendum 2 | Date | 13-07-2020 |
4 | 13-Jul-2020 | Corrigendum3 | Date | 20-07-2020 |
Name of Work:- Providing improved access to water through household connection in existing W/s Scheme Kalowal Block Chogawan Distt. Amritsar. Under PRWSSIP Sub Component 2a (ii) Providing House Connection for existing pipe line & new Pipe Line Prov.& Laying jointing, testing PVC pipe, specials for Distribution System, Sluice valve, Chamber, Installation of sign board, Repair of Pumping Machinery, Repair of panel board, Repair of Pump Chamber, Repair of OHSR & Development of water works etc. complete in all respect. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Providing & Fixing Control Panel consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. (reputed make) complete in all respects as per standard Specifications. (279 LPM and 56 m Head) | iteam1 | 1 | Job |
2 | 2 | Repair of Control Panel consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat , Shunt capacitor etc. (reputed make) complete in all respects as per standard Specifications. | iteam2 | 1 | Job |
3 | 3 | REPAIR OF PUMP CHAMBER | iteam3 | ||
4 | 3.01 | Conglomerate floor 40mm thick cement concrete 1:2:4 on 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of materials. | iteam4 | 10 | Sqm |
5 | 3.02 | Hollock wood doors shutter windows including Hinges, Screws, Chocks Cleats, Stops and Cords etc. complete fixed in position. \nPaneled glazed or glazed and paneled (Double Leaf) \n(i)40mm thick door | iteam5 | 5.7 | Sqm |
6 | 3.03 | Distempering with dry distemper of approved manufacture two coats over old distempered surface | iteam6 | 74.27 | Sqm |
7 | 3.04 | Finishing walls with exterior decorative cement based paint such as snowcem robbiacem etc. on old work one coat to give an even shade | iteam7 | 207.68 | Sqm |
8 | 3.05 | Applying Pink Primer or aluminium priming coat on wood work including preparation of surface \nWith special quality paint | iteam8 | 4.2 | sqm |
9 | 3.06 | Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. With special quality paint | iteam9 | 4.2 | sqm |
10 | 3.07 | Wiring fan point without fan box in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts (socket size). ( as per ac slip no. 3 on CSR Amendments) | iteam10 | 1 | No. |
11 | 3.08 | Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade. ( as per ac slip no. 3 on CSR Amendments)\n | iteam11 | 5 | Each |
12 | 3.09 | Wiring 3 Pin 6 Amp. Plug control comprising wall socket and switch including bonding to existing earth with PVC insulated copper conductor single core FR cable (ISI marked) overall 1 sq. mm, 1100volts grade complete. ( as per ac slip no. 3 on CSR Amendments) | iteam12 | 2 | Each |
13 | 3.1 | Wiring 3 pin 16/20 amp. power plug control and switch. | iteam13 | 1 | No. |
14 | 3.11 | Repair of Pump Chamber plinth Protection Complete in all Respects | iteam14 | 1 | No. |
15 | 4 | REPAIR OF OHSR 75000 Ltr Capacity | iteam15 | ||
16 | 4.01 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Premium make such as (Jindal/Hisar) Including cost of specials (such as Tees, bends, sockets, elbows etc.) painting with anti corrosive bitumastic paint, testing, cutting threading inside building/railing for staircase (OHSR)\n40mm i/d | iteam16 | 27.11 | mtr |
17 | 4.02 | Providing & fixing Manhole Cover Size MS 560mmx560mm manhole cover and made of 50x50x8mm angle frame fitted with MS sheet hinged cover of 6 mm thickness, Jali, Gauge 15cm width & lightning conductor of GI 7/10” SWG (10mm) dia. standard wire with lightning rod of 25mm. Dia 0.9 m. Long with earth electrode 25mm dia. 2.75mtrs. long GI pipe from ground level connecting 50mm dia 1.40 m long perforated GI pipe including fixing of clamps as per IS:2309-1969 Complete in all respects. | iteam17 | 1 | Job |
18 | 4.03 | Repair of Expansion Joint complete in all respects.\n100mm DIA | iteam18 | 2 | Each |
19 | 4.04 | 150mm DIA | iteam19 | 2 | Each |
20 | 4.05 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) Class PN-1 as per ISI | iteam20 | ||
21 | 4.06 | 100 mm i/d Sluice Valves flanged | iteam21 | 10 | Each |
22 | 4.07 | 80 mm i/d Sluice Valves flanged | iteam22 | 1 | Each |
23 | 4.08 | Repair of Leakage in Side walls and Bottom Dome of OHSR and Repair of Over Flow haudi complete in all Respects | iteam23 | 1 | Job |
24 | 4.09 | Supply, fixing and testing at site automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible/monoblock to be fixed on existing panel for OHSR complete in all respect. | iteam24 | 1 | Job |
25 | 4.1 | Painting vertical pipes, Handrailing and snowcem to OHSR including shuttering complete in all respects. | iteam25 | 1 | Job |
26 | 4.11 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 meters depth including dressing of bottom and sides of trecnches, stacking the excavated soil clear from the edge of excavation | iteam26 | 4.83 | cum |
27 | 4.12 | Cement Concrete 1:8:16 with 40mm gauge stone aggregate to be used instead of brick ballast | iteam27 | 1.58 | cum |
28 | 4.13 | First Class burnt brick work laid in cement sand mortar 1:5 in foundation of plinth | iteam28 | 3.59 | cum |
29 | 4.14 | 12.5mm thick cement plaster 1:4 | iteam29 | 12.11 | sqm |
30 | 4.15 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavaeted from foundation and taken only from outside the building plinth in 15 cum layers including ramming, watering and consolidating upto 30 meters | iteam30 | 10.9 | cum |
31 | 4.16 | Carriage of sand for earth filling a lead of 5 kms. | iteam31 | 6.07 | cum |
32 | 4.17 | Finishing walls with exterior decorative cement based such as snowecem, robbiacem etc. on old work one coat to give an even shade. | iteam32 | 6.07 | cum |
33 | 4.18 | Cement Concrete 1:8:16 with 40 mm gauge stone aggregate (CC Mixer Volumetric Type) | iteam33 | 3.89 | cum |
34 | 4.19 | Congomerate floor 40mm cement concrete topping 1:2:4 using mechanical mixer for mixing materials. | iteam34 | 44.2 | Sqm |
35 | 4.2 | Finishing wall with exterior decorative cement based paint such as snowcem robbiacem etc. on new work in two coats to give even shade | iteam35 | 7.07 | Sqm |
36 | 4.21 | Providing earthing to existing OHSR according to specification of PSPCL. | iteam36 | 1 | Job |
37 | 5 | Repair of Development of Water Work Site | iteam37 | ||
38 | 5.01 | Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing. | iteam38 | 564 | P.Mtr |
39 | 5.02 | Providing & Fixing PCC Fencing Poles With 6' height, 3" x 3" Top & 4" x 3" Base provided with 3 nos. hooks complete in all respects | iteam39 | 50 | Each |
40 | 5.03 | Providing & Fixing D hook complete with MS bolt size 300 mm x18 mm as per standard drawing D-7 & Analysis of Rates A-9 complete in all respects. | iteam40 | 24 | Each |
41 | 5.04 | Construction of Masonry Corner Pillar including cost of cement pointing as per standard drawing & Analysis of Rates complete in all respects(Including Carriage) | iteam41 | 1 | Each |
42 | 5.05 | Repair of Existing Corner Pillars and Gate Pillar Including its whitewash and painting of MS Gate complete in all respects(Including Carriage) | iteam42 | 4 | Each |
43 | 5.06 | Construction of foot paths with masonry toe wall & earth filling & concrete topping; inside water works as per standard drawing D-10 complete in all respects(Including Carriage) | iteam43 | 65 | P.Mtr |
44 | 5.07 | Providing & fixing MS Sign board including painting & printing complete as per standard size of DWSS complete in all respects(Including Carriage) | iteam44 | 1 | Job |
45 | 6 | Providing & Installing Testing & Commissioning of One No. Electrically driven diaphragm opreated metering system chemical dosing chlorinator suitable for for delivering 0.5 to 6 liters of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg/cm2 and suction left not less than 1.5 mtr., as per DWSS standard specifations. | iteam45 | 1 | Job |
46 | 7 | Minor Repair & replacement of pipe associated with repair complete in all respects \n(90 mm pvc pipe) | iteam46 | 10 | Each |
47 | 8 | Provoding & Fixing automated Water Controller complete in all respects as per standard Specifications. | iteam47 | 1 | Job |
48 | 9 | Providing and fixing in position CI Bib Cock(tap)(15 mm i/d)as per IS:210 with stainless steel spindle of approved make and Fixng of Nozzle to contro flow of water(to the approval of Enginer-in-charge Complete in all respect | iteam48 | 70 | Each |
49 | 10 | Providing proposed water connections to household up to wall with providing ,laying, jointing, fixing, testing MDPE pipe line 15 mm i/d = 2.00 mtr(Below GL) and ISI Marked G.I. Pipe 15 mm i/d (As per IS 1239) B-Class approved make = 2.50 mtr (Above GL) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground and ISI marked 15 mm i/d GM Ferrule as per IS:2692 and 3" i/d clamp with CI Bib Cock 15 mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete in all respects. \n(Connection at Existing pipe line) = 100\n(Connection at New pipe line) = 70 | iteam49 | 170 | Each |
50 | 11 | Providing, Laying , fixing & jointing of P.V.C. Pipes including specials as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications (Mechanically Excavation and Including specials) | iteam50 | ||
51 | 11.01 | PVC Pipe 90 mm o/d pipe of 6 Kgf. / sqcm | iteam51 | 1000 | Mtr. |
52 | 12 | Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department(Including Carriage) Size 0.9m x 0.9m | iteam52 | 3 | Each |
53 | 13 | Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting. | iteam53 | 750 | Mtr. |