Water Supply And Sanitation Department-WSSD has published Improved Access To Water Through Household Connections In Existing Water Supply Village Punga Jafarkot Block Ajnala District Amritsar Under Prwssip 2A Ii Providing House Connection For Existing Pipe Line New Pipe Line Prov . Laying Jointing Testing Pvc . Submission Date for this Tender is 07-09-2020. Water Supply Project Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 15-Jun-2020 | Corrigendum | Date | 24-06-2020 |
2 | 24-Jun-2020 | Corrigendum 1 | Date | 06-07-2020 |
3 | 06-Jul-2020 | Corrigendum 2 | Date | 13-07-2020 |
4 | 13-Jul-2020 | Corrigendum3 | Date | 20-07-2020 |
5 | 20-Jul-2020 | Corrigendum4 | Date | 27-07-2020 |
6 | 27-Jul-2020 | Corrigendum 5 | Date | 03-08-2020 |
7 | 03-Aug-2020 | Due Date Extended | Admin Corrigendum Date Extend | 04-08-2020 |
8 | 04-Aug-2020 | Corrigendum 6 | Date | 10-08-2020 |
9 | 10-Aug-2020 | Corrigendum7 | Date | 17-08-2020 |
10 | 17-Aug-2020 | Corrigendum8 | Date | 24-08-2020 |
11 | 24-Aug-2020 | Corrigendum9 | Date | 31-08-2020 |
12 | 31-Aug-2020 | Corrigendum10 | Date | 07-09-2020 |
Name of Work:- Providing improved access to water through household connection in existing W/s Scheme Punga & Jafarkot Block Ajnala Distt. Amritsar. Under PRWSSIP Sub Component 2a (ii) Providing House Connection for existing pipe line & new Pipe Line Prov.& Laying jointing, testing PVC pipe, specials for Distribution System, Sluice valve, Chamber, Installation of sign board, Replacement of Pumping Machinery, Prov. & installing panel board, Repair of Pump Chamber, Repair of OHSR & Development of water works etc. complete in all respect. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Cost of Replacement of Machinery Electrically driven Submersible Pumping set of reputed Make as per standard Specifications (motor with pump) complete in all respects (400 LPM 60 mtr Head) | iteam1 | 1 | Job |
2 | 2 | Cost of Submersible cable 2.50mm2 =100 mtr Complete in all respects | iteam2 | 100 | mtr. |
3 | 3 | Repair of Control Panel consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. (reputed make) complete in all respects as per standard Specifications. | iteam3 | 1 | Job |
4 | 4 | REPAIR OF PUMP CHAMBER | iteam4 | ||
5 | 4.01 | Terracing consisting of tiles 22.86cm×11.43cm×3.83cm laid over25mm mud plaster, 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65Kg. Per Sqm on top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc. (Including Carriage.) | iteam5 | 12.35 | cum |
6 | 4.02 | 12.5mm thick cement plaster 1:4 ( Including Carriage.) | iteam6 | 114.3 | Sqm |
7 | 4.03 | 12.5mm thick cement plaster 1:4 ( Including Carriage.) | iteam7 | 13.08 | Mtr. |
8 | 4.04 | Hollock wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them) (a)30 mm Thick | iteam8 | 0.78 | Sqm |
9 | 4.05 | Kiln seasonal Hollock wood cup board chowkats including iron hold fasts, iron hinges corner straps, wooden knobs or handles fixed in position (Size 45 x 60mm).\n(a) 30mm thick Cup Board | iteam9 | 0.78 | Sqm |
10 | 4.06 | Applying Pink Primer or aluminium priming coat on wood work including preparation of surface \n With special quality paint | iteam10 | 13.15 | sqm |
11 | 4.07 | Applying priming coat with metal primer on new steel or iron work including preparation of surface andPainting two coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work. With special quality paint. | iteam11 | 11.43 | sqm |
12 | 4.08 | White washing 3 coats inside of pump chamber. | iteam12 | 13.08 | sqm |
13 | 4.09 | Finishing wall with exterior decorative cement based paint such as snowcem robbiacem etc. on new work in two coats to give even shade. | iteam13 | 64.19 | sqm |
14 | 4.1 | Providing and fixing of Glass strips 4mm thick in floors | iteam14 | ||
15 | 4.11 | 50mm wide | iteam15 | 23 | Each |
16 | 4.12 | 40mm wide | iteam16 | 21 | Each |
17 | 4.13 | Preparation of plastered surfaces for distempring including surface, applying filling with approved quality filler consisting of plaster of paris and chak mitti including finicshing the surface to the required finish complete. In side pump chamber | iteam17 | 50.11 | Sqm |
18 | 4.14 | Distempring with dry distemper of approved manufactuer two coats over one primer coat to give and even shade | iteam18 | 50.11 | Sqm |
19 | 4.15 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. \n(b)Glass panes 4mm thick above 0.40 sqm area. | iteam19 | 6.9 | Sqm |
20 | 4.16 | Wiring fan point without fan box in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts (socket size). ( as per ac slip no. 3 on CSR Amendments) | iteam20 | 1 | Each |
21 | 4.17 | Providing and fixing of ceiling fan of reputed make such as Crompton or equivalent | iteam21 | 1 | Each |
22 | 4.18 | Providing and fixing of electric tube set of reputed make | iteam22 | 1 | Each |
23 | 4.19 | Providing and fixing MS Tubewell Cover (Borepit Cover) Size 560mmx560mm | iteam23 | 1 | Each |
24 | 4.2 | Minor Repair of Wooden door of Pump Chamber | iteam24 | 1 | L.S |
25 | 4.21 | Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Class PN-1.0 as per ISI with rubber Flap (b)100mm i/d Non-return valve | iteam25 | 1 | Each |
26 | 4.22 | (c) Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/12 S.W.G. (7/2.80mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length(including boring & refilling). | iteam26 | 1 | Each |
27 | 5 | REPAIR OF OHSR (Capacity 25000 Ltr FSL 18mtr) | iteam27 | ||
28 | 5.01 | First Class burnt brick work laid in cement sand mortar 1:5 in foundation of plinth | iteam28 | 1.15 | cum |
29 | 5.02 | Cement Concrete 1:8:16 with 40mm gauge stone aggregate to be used instead of brick ballast | iteam29 | 2.04 | cum |
30 | 5.03 | Conglomerate floor 40mm cement concrete topping 1:2:4 | iteam30 | 24.2 | cum |
31 | 5.04 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) Class PN-1 as per ISI | iteam31 | ||
32 | 5.05 | 80 mm i/d Sluice Valves flanged | iteam32 | 1 | Each |
33 | 5.06 | 100 mm i/d Sluice Valves flanged | iteam33 | 2 | Each |
34 | 5.07 | Repair of Expansion Joint including shuttering & material complete in all respects 100 mm Dia | iteam34 | 1 | Each |
35 | 5.08 | Providing & Fixing 1 RCC Roof Ventilator Complete in all respects | iteam35 | 1 | Job |
36 | 5.09 | Providing & fixing Manhole Cover Size MS 560mmx560mm manhole cover and made of 50x50x8mm angle frame fitted with MS sheet hinged cover of 6 mm thickness | iteam36 | 1 | Each |
37 | 5.1 | Repair of over flow haudi of size 1.20x1.20x1.20m for OHSR Complete in all respects. | iteam37 | ||
38 | 5.11 | Cement Concrete 1:2:4 with stone ballast or Shingle | iteam38 | 0.06 | cum |
39 | 5.12 | First Class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth | iteam39 | 1.92 | cum |
40 | 5.13 | 12.5mm thick cement plaster in 1:4 | iteam40 | 10.72 | sqm |
41 | 5.14 | Supplying, Fixing and testing at site Automatic electronic type water level indication system with gun meta float sensor and electrical cable suitable for three phase pump submersible/monoblock to be fixed on existing panel for OHSRs complete in all respects. | iteam41 | 1 | Job |
42 | 5.15 | Plugging all leakages of existing RCC OHSR including necessary material e.g. cement, sand, Dr.Fixit etc. with pressure gun & cleaning of existing RCC OHSR etc. Complete in all respect as per site condition and as desired by Engineer-in-charge. | iteam42 | 1 | Job |
43 | 5.16 | Painting one coat on iron sheets roofing with ready mixed paint in all shades on old work given an even shades\n(a) With special quality paint \n100mm i/d CI Pipe 47 mtr\n90mm i/d CI Pipe 15 mtr | iteam43 | 1 | Job |
44 | 5.17 | Providing & Fixing Aluminium Ladder Inside the tank shall be 60cm wide made from Aluminium section LS 974 size, 66.68x31.75x4mm, weight 1.27 kg/m with steps made out of Aluminium section H, SP 3024 size 35x16.70x1.60mm, weight 0.362kg/m to be fixed on side in the top dome and other side in the bottome dome | iteam44 | 1 | Job |
45 | 6 | DEVELOPMENT OF WATER WORKS | iteam45 | ||
46 | 6.01 | Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6. | iteam46 | 300 | P.Mtr |
47 | 6.02 | Providing & Fixing PCC Fencing Poles With 6' height, 3" x 3" Top & 4" x 3" Base provided with 3 nos. hooks complete in all respects | iteam47 | 40 | Each |
48 | 6.03 | Providing & Fixing D hook complete with MS bolt size 300 mm x18 mm as per standard drawing D-7 & Analysis of Rates A-9 complete in all respects. | iteam48 | 20 | Each |
49 | 6.04 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3(Including Carriage) | iteam49 | 3 | Each |
50 | 6.05 | Providing & fixing MS Sign Board as per standard size of DWSS as per analysis A-24 Complete in all respects(Including Carriage) | iteam50 | 1 | Each |
51 | 6.06 | Repair of Gate Pillar Complete in all respects(Including Carriage) | iteam51 | 1 | Job |
52 | 6.07 | Repair & Fixing of MS Gate Including Welding Works, Arle, Alignment Complete in all respects | iteam52 | 1 | Job |
53 | 6.08 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) Class PN-1 as per ISI \n(b)100 mm i/d Sluice Valves flanged | iteam53 | 1 | Job |
54 | 6.09 | Supplying and laying C.I. specials as per IS:1538 complete as desired by Engineer-in-Charge conforming to ISI specifications. (a)C.I. specials upto 300mm i/d | iteam54 | 50 | Kg |
55 | 6.1 | Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard | iteam55 | 20 | mtr. |
56 | 6.11 | Providing, Laying , fixing & jointing of P.V.C. Pipes including specials as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications (Mechanically Excavation and Including specials)\nPVC Pipe 110 mm o/d pipe of 10 Kgf. / sqcm | iteam56 | 12 | mtr. |
57 | 7 | Providing & Installing Testing & Commissioning of One No. Electrically driven diaphragm opreated metering system chemical dosing chlorinator suitable for for delivering 0.5 to 6 liters of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg/cm2 and suction left not less than 1.5 mtr., as per DWSS standard specifations. | iteam57 | 1 | Job |
58 | 8 | Minor Repair & replacement of pipe associated with repair complete in all respects (90 mm pvc pipe) | iteam58 | 2 | Each |
59 | 9 | Providing and fixing in position CI Bib Cock(tap)(15 mm i/d)as per IS:210 with stainless steel spindle of approved make and Fixng of Nozzle to contro flow of water(to the approval of Enginer-in-charge Complete in all respect | iteam59 | 80 | Each |
60 | 10 | Providing proposed water connections to household up to wall with providing ,laying, jointing, fixing, testing MDPE pipe line 15 mm i/d = 2.00 mtr(Below GL) and ISI Marked G.I. Pipe 15 mm i/d (As per IS 1239) B-Class approved make = 2.50 mtr (Above GL) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground and ISI marked 15 mm i/d GM Ferrule as per IS:2692 and 3" i/d clamp with CI Bib Cock 15 mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete in all respects. \n(Connection at Existing pipe line) = 238\n(Connection at New pipe line) = 50 | iteam60 | 288 | Each |
61 | 11 | Providing, Laying , fixing & jointing of P.V.C. Pipes including specials as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications (Mechanically Excavation and Including specials) | iteam61 | ||
62 | 11.01 | PVC Pipe 90 mm o/d pipe of 6 Kgf. / sqcm | iteam62 | 250 | Mtr. |
63 | 11.02 | PVC Pipe 63 mm o/d pipe of 6 Kgf. / sqcm | iteam63 | 600 | Mtr. |
64 | 12 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) Class PN-1 as per ISI | iteam64 | ||
65 | 12.01 | 80 mm i/d Sluice Valves flanged | iteam65 | 2 | Each |
66 | 13 | Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department(Including Carriage) Size 0.6m x 0.6m | iteam66 | 2 | Each |
67 | 14 | Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting. | iteam67 | 150 | mtr. |
68 | 15 | Providing, fixing and jointing ISI Marked Gun-Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. 50mm i/d Gun Metal peet valve heavy pattern. | iteam68 | 2 | Each |
69 | 16 | Dismantling of Bithminous course of flexible pavements by mannual means and disposal of dismantled material upto lead of 1000 mtrs, stacking servicable and unservicable material saperately as per technical clause 202 of MORT & H specifications. | iteam69 | 100 | Each |
70 | 17 | Credit for Old Machinery (-) | iteam70 | 1 | Job |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy