}

Rate Contract For Distribution Transformers Level 2 Ct / Pt Transrformers And Servo Controlled Transformers/Lt Switchgear Power Control Panel, Jammu-Jammu And Kashmir

Small Scale Industries Development Corp. Ltd. has published Rate Contract For Distribution Transformers Level 2 Ct / Pt Transrformers And Servo Controlled Transformers/Lt Switchgear Power Control Panel. Submission Date for this Tender is 06-07-2020. Transformer Oil Tenders in Jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

24477246
Corrigendum : Rate Contract For Distribution Transformers Level 2 Ct / Pt Transrformers And Servo Controlled Transformers/Lt Switchgear Power Control Panel
National Competitive Bid
Indian
Jammu And Kashmir
Jammu
06-07-2020

Tender Details

Rate Contract For Distribution Transformers Level 2 Ct / Pt Transrformers And Servo Controlled Transformers/Lt Switchgear Power Control Panel , Item , Outdoor Type Three Phase Oil Immersed 11Kv/433-250V , 50 Hz Aluminium Wound Distribution Transformer Of Energy Efficiency Level-2 As Per Is:1180 ( Part-I ) :2014 ( Bis Marked ) As Per Pdd Approved Specification 25 Kva , Outdoor Type Three Phase Oil Immersed 11Kv/433-250V , 50 Hz Aluminium Wound Distribution Transformer Of Energy Efficiency Level-2 As Per Is:1180 ( Part-I ) :2014 ( Bis Marked ) As Per Pdd Approved Specification 63 Kva , Outdoor Type Three Phase Oil Immersed 11Kv/433-250V , 50 Hz Aluminium Wound Distribution Transformer Of Energy Efficiency Level-2 As Per Is:1180 ( Part-I ) :2014 ( Bis Marked ) As Per Pdd Approved Specification 100 Kva , Outdoor Type Three Phase Oil Immersed 11Kv/433-250V , 50 Hz Aluminium Wound Distribution Transformer Of Energy Efficiency Level-2 As Per Is:1180 ( Part-I ) :2014 ( Bis Marked ) As Per Pdd Approved Specification 200 Kva , Outdoor Type Three Phase Oil Immersed 11 Kv/433/-250V , 50Hz Copper Wound Distribution Transformers Of Energy Efficiency , Level-2 As Per Is: 1180 ( Part-1 ) :2014 Of Rating250 Kva , Outdoor Type Three Phase Oil Immersed 11 Kv/433/-250V , 50Hz Copper Wound Distribution Transformers Of Energy Efficiency , Level-2 As Per Is: 1180 ( Part-1 ) :2014 Of Rating400 Kva , Outdoor Type Three Phase Oil Immersed 11 Kv/433/-250V , 50Hz Copper Wound Distribution Transformers Of Energy Efficiency , Level-2 As Per Is: 1180 ( Part-1 ) :2014 Of Rating630 Kva , Servo Controlled Automatic Voltage Regulator Capacity 450 Kva ( As Per Is:9815 ) Indoor Type Oil Cooled 3 Phase 4 Wire Unbalanced Type 50 Cycles Input Voltage 260-450 V Phase To Phase Output Voltage 415V + 1% Phase To Phas Voltmeter For Recording Input And Output Voltage Separately On Each Visual Indication For Voltage Beyond Its Range Auto Manual Switch For Operating The Stabilizer Manually Through Push Button In The Event Of Some Defect In The Automatic Circuit . , Servo Controlled Automatic Voltage Regulator Capacity 450 Kva ( As Per Is:9815 ) Indoor Type Oil Cooled 3 Phase 4 Wire Unbalanced Type 50 Cycles Input Voltage 260-430 V Phase To Phase Output Voltage 415V + 1% Phase To Phas Voltmeter For Recording Input And Output Voltage Separately On Each Visual Indication For Voltage Beyond Its Range Auto Manual Switch For Operating The Stabilizer Manually Through Push Button In The Event Of Some Defect In The Automatic Circuit . , Servo Controlled Automatic Voltage Regulator Capacity 400 Kva ( As Per Is:9815 ) Indoor Type Oil Cooled 3 Phase 4 Wire Unbalanced Type 50 Cycles Input Voltage 260-430 V Phase To Phase Output Voltage 415V + 1% Phase To Phas Voltmeter For Recording Input And Output Voltage Separately On Each Visual Indication For Voltage Beyond Its Range Auto Manual Switch For Operating The Stabilizer Manually Through Push Button In The Event Of Some Defect In The Automatic Circuit . , Servo Controlled Automatic Voltage Regulator Capacity 250 Kva ( As Per Is:9815 ) Indoor Type Oil Cooled 3 Phase 4 Wire Unbalanced Type 50 Cycles Input Voltage 260-430 V Phase To Phase Output Voltage 415V + 1% Phase To Phas Voltmeter For Recording Input And Output Voltage Separately On Each Visual Indication For Voltage Beyond Its Range Auto Manual Switch For Operating The Stabilizer Manually Through Push Button In The Event Of Some Defect In The Automatic Circuit . , Servo Controlled Automatic Voltage Regulator Capacity 100 Kva ( As Per Is:9815 ) Indoor Type Oil Cooled 3 Phase 4 Wire Unbalanced Type 50 Cycles Input Voltage 260-430 V Phase To Phase Output Voltage 415V + 1% Phase To Phas Voltmeter For Recording Input And Output Voltage Separately On Each Visual Indication For Voltage Beyond Its Range Auto Manual Switch For Operating The Stabilizer Manually Through Push Button In The Event Of Some Defect In The Automatic Circuit . , Servo Controlled Automatic Voltage Regulator Capacity 63 Kva ( As Per Is:9815 ) Indoor Type Oil Cooled 3 Phase 4 Wire Unbalanced Type 50 Cycles Input Voltage 260-430 V Phase To Phase Output Voltage 415V + 1% Phase To Phas Voltmeter For Recording Input And Output Voltage Separately On Each Visual Indication For Voltage Beyond Its Range Auto Manual Switch For Operating The Stabilizer Manually Through Push Button In The Event Of Some Defect In The Automatic Circuit . , 11 Kv Ct/Pt Units Ratio From : 1/5 Amp . To 1000/5 Amp ( Must Be Crpi/Erda Approved ) , 33 Kv Ct/Pt Combined Unit Ratio From : 5/5 Amp . To 1000/5 Amp , 33 Kv Ct/Pt Combined Unit Ratio From 50/1 Amp . To 750/1 Amp , Lt Switchgear Power Control Panel Floor Mounted , Indoor Type Made Out Of 14/16 Swg/Crc Sheet Steel Duly Power Coated Free From Dents , Dust , Uneven Surfaces Vermin Proof Suitable For 415 Volt 3 Phase 4 Wire 50Hz System ( Ac Supply ) Complete With Hinged Doors Having Locking Arrangement With Voltmeter ( 0-500 ) Volts With Selector Switch Ammeter With Selector Switch Current Transformers Of Suitable Rating L . E . D Indicators ( R , Y , B ) High Conductivity Electrolytic Grade Aluminum/Copper Bus Bar Of Required Rating Tpn With Heat Shrinkable Sleeves , Duly Colour Coded On-Load Changeover Switch Of Require Rating ( L&T ) , Lt Switchgear Extra As Per Requirement , Supply Of Power Transformer 10 Mva 33/11 Kv 3 Phase 50 Hz Delta Star Onan Cooling Double Copper Wound Oil Immersed Outdoor Type Power Transformer Fitted With On Load Tap Changer With Rtcc Panel And Fitting Accessories Conforming To Is:2026 ( With Latest Amendments ) And With First Filling Of Transformer Oil Conforming To Is: 335 ( With Latest Amendments ) ( As Per Pdd Approved Specification ) , Supply Of Power Transformer 6 . 3 Mva 33/11 Kv 3 Phase 50 Hz Delta Star Onan Cooling Double Copper Wound Oil Immersed Outdoor Type Power Transformer Fitted With On Load Tap Changer With Rtcc Panel And Fitting Accessories Conforming To Is:2026 ( With Latest Amendments ) And With First Filling Of Transformer Oil Conforming To Is: 335 ( With Latest Amendments ) ( As Per Pdd Approved Specification ) , Supply Of Power Transformer 3 . 15 Mva 33/11 Kv 3 Phase 50 Hz Delta Star Onan Cooling Double Copper Wound Oil Immersed Outdoor Type Power Transformer Fitted With On Load Tap Changer With Rtcc Panel And Fitting Accessories Conforming To Is:2026 ( With Latest Amendments ) And With First Filling Of Transformer Oil Conforming To Is: 335 ( With Latest Amendments ) ( As Per Pdd Approved Specification ) , Supply Of Power Transformer 10 Mva 33/11 Kv 3 Phase 50 Hz Delta Star Onan Cooling Double Copper Wound Oil Immersed Outdoor Type Power Transformer Fitted With Off Circuit Tap Changer And Fitting Accessories Conforming To Is:2026 ( With Latest Amendments ) And With First Filling Of Transformer Oil Conforming To Is: 335 ( With Latest Amendments ) ( As Per Pdd Approved Specification ) , Supply Of Power Transformer 6 . 3 Mva 33/11 Kv 3 Phase 50 Hz Delta Star Onan Cooling Double Copper Wound Oil Immersed Outdoor Type Power Transformer Fitted With Off Circuit Tap Changer And Fitting Accessories Conforming To Is:2026 ( With Latest Amendments ) And With First Filling Of Transformer Oil Conforming To Is: 335 ( With Latest Amendments ) ( As Per Pdd Approved Specification ) , Supply Of Power Transformer 3 . 15 Mva 33/11 Kv 3 Phase 50 Hz Delta Star Onan Cooling Double Copper Wound Oil Immersed Outdoor Type Power Transformer Fitted With Off Circuit Tap Changer And Fitting Accessories Conforming To Is:2026 ( With Latest Amendments ) And With First Filling Of Transformer Oil Conforming To Is: 335 ( With Latest Amendments ) ( As Per Pdd Approved Specification ) , Supply Of Power Transformer 6 . 3 Mva 33/11 Kv 3 Phase 50 Hz Delta Star Onan Cooling Double Wounded Oil Immersed Outdo

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Jun-2020 Corrigendum Date 06-07-2020

Key Value

Document Fees
INR 25 /-
EMD
INR 5000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail