Mla Sdf- Rwss To Malayalappuzha - Supply And Erection Of C/F Pump Set At Booster Pump House And Vt Pumpset At Intake Pump House Malayalappuzha ( Project No . 10561 ) , Pathanamthitta District-Kerala

Kerala Water Authority-KWA has published Mla Sdf- Rwss To Malayalappuzha - Supply And Erection Of C/F Pump Set At Booster Pump House And Vt Pumpset At Intake Pump House Malayalappuzha ( Project No . 10561 ) . Submission Date for this Tender is 10-06-2020. Bolts Tenders in Pathanamthitta District Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

24476445
Mla Sdf- Rwss To Malayalappuzha - Supply And Erection Of C/F Pump Set At Booster Pump House And Vt Pumpset At Intake Pump House Malayalappuzha ( Project No . 10561 )
Open Tender
Indian
Kerala
Pathanamthitta District
10-06-2020

Tender Details

Mla Sdf- Rwss To Malayalappuzha - Supply And Erection Of C/F Pump Set At Booster Pump House And Vt Pumpset At Intake Pump House Malayalappuzha ( Project No . 10561 ) , Appendix-1- Supplying And Installing Brand New C/F Pump Set At Booster Pump House , Supply , Erection And Commissioning Of Brand New Cf Pump Set With The Following Specification . , 1 . Pump - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Centrifugal Pump Sets With Bronze/Ss Impeller , Ss Shaft And Ci Pump Casing With Suitable Type Base Plate With Coupling , Coupling Guard Foundation Bolts; Nuts Etc . Complete Suitable For Coupling The Pump And Motor Above The Plate Etc . Complete Including Providing Suitable Concrete Foundation Including Cost Of Cement , Sand And Metal Etc . Complete , 2 . Motor - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Horizontal Solid Shaft Foot Mounted Tefc Squirrel Cage Induction Motor Suitable For The Above Pump Working 3 Phase 50 Hz Ac Supply , Working Voltage 415V . The Motor Shall Confirm To Eefi/Is 325 Including Providing Suitable Concrete Foundation Including Cost Of Cement , Sand And Metal Etc . Complete . Flexible Coupling Shall Be Used For Coupling Of Pumps And Motors . , 3 . Starter - Supply , Erection Testing And Commissioning Of Suitable Rating ( Fully Automatic Starter With Air Break Contact For Less Than 100Hp And For Above 100Hp Fmca Starters To Be Used ) Starter Suitable For The Above Motor With Over Voltage And Under Voltage Protection , Single Face Preventer , Over Load Relay With Motor Protection Relay With Main Contactor And Bypass Contactor As Per Ie Rules And Code Of Practice Etc . Complete , 4 . Panel Board ( Suitable For Operating Two Pump Sets But One Pump Set At A Time ) ;Supply , Erection Testing And Commissioning Of Cubical Type Floor Mounted Ms Fabricated Dust And Vermin Proof Common Control Panel Board Consisting Of 1No . Suitable Capacity Mccb As Incomer And 2Nos . Suitable Capacity Mccb As Out Going ( The Two Mccbs Are Interlocking With Each Other ) Providing Suitable Size Aluminium Bus Bar Interconnect The Above Mccbs And Fitted With 3Nos . Of Indicator Lamps , 1No . Volt Meter With Selector Switch , 1No . Ammeter With Selector Switch Etc . Complete And Provided With A Common Earth Bus For The Entire Panel And Interconnect With The Mccbs As Per Ie Rules And Code Of Practice . The Panel Shall Be Fitted On A Common Base Frame On Suitable Foundation . , 5 . Cabling Work - Supply , Laying , Testing And Commissioning Of Suitable Size Xlpe Cables For The Above Pump Set From Panel Board To Starter And From Starter To Motor Considering Energy Conservations . , 6 . Earthing - Supply Of Al Materials And Providing Suitable Earthing By Using Suitable Size Pipe/Plate Earthing Gi/Copper Strip Buried In Ground And Giving Double Earthing To Motor , Starter , Panel Board Etc . As Per Ie Standards . , 7 . Capacitor - Supply , Erection Testing And Commissioning Of Heavy Duty App Capacitor For The Motor To Get A Power Factor Above 0 . 95 . The Capacitor Shall Confirm To Is 2834 , 8 . Valves - Supply Of Suitable Size Best Quality Heavy Duty Isi Marked Ci Double Flanged Sluice Valve And Non Return Valve With Suitable Pressure Rating . Fitting Of Valves Shall Include Proper Rcc Support Especially For Non Return Valves . In Case Of Positive Suction Pump Set Sluice Valve Should Be In Suction As Well As Delivery Sides For Easy Repair Works . , 9 . Suction And Delivery Pipe Connection -Supply And Fitting Of Suitable Size Best Quality Gi/Ms Pipe Of Thickness Not Less Than 8Mm For A Total Length Of 10M . Suitable For The Above Pump Set And Suitable Size Foot Valve And Connecting The Suction Pipe And Valve With Suitable Flanges , Nut And Bolts Ir Sheet Etc . Complete And Connecting The Delivery Side Of The Pump With The Valves And Suitable Specials To Connect With The Pumping Main . , Discharge = 2100 LpmTotal Head = 112 MRpm = 1400-1500 Range . , Fabricating Ms Pipes Of Size 150Mm ( Id ) Using 8 Mm Thick Ms Plate Including Cost And Conveyance Charges Of Ms Plate , All Fabrication Charges , Charges Of Painting The Steel Work With Two Or More Coat Deluxe Multi Surface Paint To Give An Even Shade Over An Under Coat Of Primer Etc . Complete: For Pipes Fabricated With 8Mm Thick Ms Plates . , Fabricating Ms Pipes Of Size 200Mm ( Id ) Using 8 Mm Thick Ms Plate Including Cost And Conveyance Charges Of Ms Plate , All Fabrication Charges , Charges Of Painting The Steel Work With Two Or More Coat Deluxe Multi Surface Paint To Give An Even Shade Over An Under Coat Of Primer Etc . Complete: For Pipes Fabricated With 8Mm Thick Ms Plates . , Demolishing The Rcc Side Wall Of Pump House Required Dia For Connecting The Suction Pipe With Pump And Restore The Remaining Portions After Connecting The Pipe As Per The Direction Of Departmental Officers . , Fabricating Suction Pipe From Tank To Pump Using Ms Pipe And Fabricating Delivery Pipe Line From Pump To Delivery Main Including Fabricating Bend , Cutting Welding Grinding And Providing Flanges Joints Including The Cost Of Flanges But Excluding The Cost Of Ms As Per The Site Condition . , Appendix-Ii- Rwss To Malayalppuzha- Supplying And Installing Brand New Vt Pumpset At Intake , Supply , Erection And Commissioning Of Brand New Vt Pump Set With The Following Specification . , 1 . Pump - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Water Lubricated Vertical Turbine Pumpset With Bronze/Ss Impeller , Ss Shaft With Ms Erw Column Pipe Of Suitable Diameter And Length . The Pumpset Shall Be Suitable To Be Coupled With Vertical Hollow Shaft Motor . The Duty Condition Of Pumpset Are: Discharge - 1850 Lpm , Total Head 130 Meter , Delivery Size So As To Suit The Existing Pumping Main . , 2 . Motor - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make ( F . L . Speed Of Motor- 1400-1500 Rpm ) Screen Protected Drip Proof Squirrel Cage Vertical Hollow Shaft Induction Motor Suitable For Operation At 415 Volts 3 Phase 50 Hz . Ac Supply For The Above Pumpset . The Motor Should Confirm To Eefi/Is 325 . Supply Of Suitable Size Best Quality Isi Marked Pn 1 . 6 Heavy Duty Cast Iron Double Flanged Sluice Valve And Reflex Valve Suitable For The Above Pumpset . Fabricating And Connecting Delivery Pipe Of Required Size With Y- Connection And Necessary Joints Made Out Of Suitable Size Ms Pipe In Suitable Length With Required Flanged Joints And Seating On Supports As Per Site Condition . Supply Of Of The Motor Is Including Providing Suitable Concrete Foundation , Cost Of Cement , Sand And Metal Etc . Complete . Flexible Coupling Shall Be Used For Coupling Of Pumps And Motors , 3 . Starter - Supply , Erection Testing And Commissioning Of Suitable Rating ( Fully Automatic Starter With Air Break Contact For Less Than 100Hp And For Above 100Hp Fmca Starters To Be Used ) Starter Suitable For The Above Motor With Over Voltage And Under Voltage Protection , Single Face Preventer , Over Load Relay With Motor Protection Relay With Main Contactor And Bypass Contactor As Per Ie Rules And Code Of Practice Etc . Complete , 4 . Panel Board ( Suitable For Operating Two Pump Sets But One Pumpset At A Time ) -Supply , Erection Testing And Commissioning Of Panel Board Consisting Of Suitable Capacity Tpn Swith With Hrc Fuse/ Mccb Voltmeter With Selector Switch , Ammeter With Selector Switch , Fitted With 3 Nos . Of Indicator Lamps With All Fittings As Per Ie Rules , Panel Board Shall Have Facilities And Capacity For Operating 2 Nos Of Motor Of Above Capacity And Should Have Necessary Interlocking Arrangements . The Panel Should Have Provision For Fixing Capacitor And Giving Electric Connection To All Equipments As Per Ie Rules And Code Of Practice . Conducting Satisfactory Trial Etc . Complete As

Key Value

Document Fees
INR 2800 /-
EMD
INR 50000.0 /-
Tender Value
INR 28.08 Lakhs /-