Name of Work: Supply of Cooling Coils for FCU required for INS Sujata [WO: 20001]. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Cooling coil for FCU, SPECS:\nMAKE: Carrier Transicold(i) System air\nvolume : 800 M3/Hr(ii) Total static\npressure : 12.7 mm Wg(iii) Cooling coil\nrow : 4(iv) Cooling capacity : 4416 Kcal/\nh(v) Entering water temp : 10 Deg C(vi)\nLeaving water temp : 15 Deg C(vii) Water\nflow rate : 14.72 LPM(viii) Coil water PD :\n0.33 M.WgNecessary accessories like\npressure gauges, and end fittings to\nbeprovided.Installation <(>&<)>\nCommissioning Assistance is required | 1300009603 | 1 | NOS |
2 | 2 | Cooling coil for FCU, SPECS:\nMAKE: Carrier Transicold(i) System air\nvolume : 950 M3/Hr(ii) Total static\npressure : 12.7 mm Wg(iii) Cooling coil\nrow : 4(iv) Cooling capacity : 6726 Kcal/\nh(v) Entering water temp : 10 Deg C(vi)\nLeaving water temp : 15 Deg C(vii) Water\nflow rate : 22.44 LPM(viii) Coil water PD :\n0.58 M.WgNecessary accessories like\npressure gauges, and end fittings to\nbeprovided.Installation <(>&<)>\nCommissioning Assistance is\nrequired | 1300009604 | 1 | NOS |
3 | 3 | Cooling coil for FCU, SPECS:\nMAKE: Carrier Transicold(i) System air\nvolume : 400 M3/Hr(ii) Total static\npressure : 3.81 mm Wg(iii) Cooling coil\nrow : 4(iv) Cooling capacity : 2592 Kcal/\nh(v) Entering water temp : 10 Deg C(vi)\nLeaving water temp : 15 Deg C(vii) Water\nflow rate : 8.67 LPM(viii) Coil water PD :\n2.9 M.WgNecessary accessories like\npressure gauges, and end fittings to\nbeprovided.Installation <(>&<)>\nCommissioning Assistance is required. | 1300009605 | 1 | NOS |
4 | 4 | Cooling coil for FCU, SPECS:\nMAKE: Carrier Transicold(i) System air\nvolume : 700 M3/Hr(ii) Total static\npressure : 3.81 mm Wg(iii) Cooling coil\nrow : 4(iv) Cooling capacity : 3864 Kcal/\nh(v) Entering water temp : 10 Deg C(vi)\nLeaving water temp : 15 Deg C(vii) Water\nflow rate : 12.87 LPM(viii) Coil water PD :\n2.5 M.WgNecessary accessories like\npressure gauges, and end fittings to\nbeprovided.Installation <(>&<)>\nCommissioning Assistance is required. | 1300009606 | 1 | NOS |
5 | 5 | Cooling coil for FCU, SPECS:\nMAKE: Carrier Transicold(i) System air\nvolume : 900 M3/Hr(ii) Total static\npressure : 12.7 mm Wg(iii) Cooling coil\nrow : 4(iv) Cooling capacity : 5832 Kcal/\nh(v) Entering water temp : 10 Deg C(vi)\nLeaving water temp : 15 Deg C(vii) Water\nflow rate : 19.45 LPM(viii) Coil water PD :\n0.33 M.WgNecessary accessories like\npressure gauges, and end fittings to\nbeprovided.Installation <(>&<)>\nCommissioning Assistance is required. | 1300009607 | 1 | NOS |