Military Engineer Services-MES has published Special Repair To Bldg No P-139 At Mil Stn Nabha . As Per Tender Document. Submission Date for this Tender is 24-06-2020. Building Repair Tenders in Mil Stn Nabha Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 17-Jun-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-06-2020 |
Name of Work: SPECIAL REPAIR TO BLDG NO P-139 AT MIL STN NABHA. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed.\n\n | 200 | Sqm | |
2 | 2 | M & L for 15mm thick ( in two layers of 10mm and 5mm thickness) cement pastering in cement mortar 1:4 and mixig the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished fair and even without using extra cement complete all as specified and directed\nNote : Water proofing compound shall be measured and paid saparately under item No 3 . | 200 | Sqm | |
3 | 3 | Supply only integral water proofing compound ISI marked. | 15 | Litre | |
4 | 4 | Preparation of old painted steel or iron based surfaces, of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint in complete all as specified and as directed. | 25 | Sqm | |
5 | 5 | Complete removal of existing treatment of any type/description such as cement base paint, external emulsion etc from external surfaces of walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc with mechanical means/grinder including removal of waste material from site complete all as specified and directed. | 500 | Sqm | |
6 | 6 | Applying acrylic wall care putty in external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed by Engr-in-Charge.\nNotes : (i) The prepared surface after wall putty, the contractor will inform to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the Engineer-in-Charge through site order.\n | 700 | Sqm | |
7 | 7 | Applying 02 coats of exterior emulsion paint (light shade) as per manufacturer instructions by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer as recommended for under coat by manufacturer of exterior emulsion, complete all as specified and directed.\n | 700 | Sqm | |
8 | 8 | Complete removal of existing treatment of any type/description such as distempering work, internal emulsion etc from internal surfaces of walls & ceiling with mechanical means/grinder including removal of material from site complete all as specified and directed. | 500 | Sqm | |
9 | 9 | Applying acrylic thick wall care putty on internal surfaces of walls/ceilings (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed.\nNotes : (i) The prepared surface after wall putty, the contractor will inform to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the Engineer-in-Charge through site order. | 500 | Sqm | |
10 | 10 | Applying 02 coats of interior emulsion paint (light shade) as per manufacturer intructions by using roller to wall surfaces over & including a coat of interior wall primer as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed.\n | 500 | Sqm | |
11 | 11 | Dismantling of floor or wall tiling including cement mortar bedding but not backing and removing the rubbish off the premises complete all as specified and directed. | 135 | Sqm | |
12 | 12 | M&L for anti skid coloured pressed ceramic floor tiles of minimum size 600X600 mm 8 to 10mm thick in flooring etc set and jointed in neat cement lurry and pointed in white cement to match over and laid over 20mm thick screed bed in CM (1:4), complete all as specified and directed. | 110 | Sqm | |
13 | 13 | M&L for 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates for base of flooring in complete all as specified and directed. | 110 | Sqm | |
14 | 14 | Coloured glazed ceramic tiles (300 x 600 mm) x 7mm thick as in vertical surfaces such as skirtings, dados etc jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick back coat in CM (1:4), in complete all as specified and directed. | 25 | Sqm | |
15 | 15 | Dismantling of asbestos cement sheets [corrugated, semi-corrugated, etc] in roof coverings complete all as specified | 600 | Sqm | |
16 | 16 | S & F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws complete all as specified and directed. | 600 | Sqm | |
17 | 17 | Dismantling of unserviceable wrought iron or mild steel of any description not other wise provided for complete all as directed . | 10 | Qtl | |
18 | 18 | M&L for rolled sections as in main and cross beams, hip and jack rafters purlins, where connected to common rafters and running rails and guides for structural purpose, fixed with angle cleats or other connecting plates to Fe-290 (Gde E-165), complete all as specified and directed. | 1000 | Kg | |
19 | 19 | Demolition of brick work or stone masonry built in cement mortar including all quions, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete. | 20 | Cum | |
20 | 20 | M&L for brick work in cement mortar (1:4) using sub class 'B' bricks staight or curved on plan exc 6.0 m mean raidus, complete all as specified and directed. | 17 | Cum | |
21 | 21 | All as per serial item no 20 but except bricks (bricks retrieved from item no 19 shall be re-used in this item), complete all as specified and directed. | 3 | Cum | |
22 | 22 | Providing and fixing factory made uPVC white colour sliding window two track made of extruded profile with wall thickness 0f 2.3mm (+- 0.2mm) window profile with hollow section with multi chamber frame (60mmx62mm), sliding sash (42mmx67mm), sliding interlock (one verticle length in each shutters) (45.5mm28mm),glazing bead (24.5mmx16mm) will be mitered cut and and fushion welded at all corners, including railing of holes for fixinghardware at and drainage of water etc, making arrangement for fixing of hardware, EPDM gasket, 1.2+-0.2mm thick galvanised steel frame (30mmx21.5mm) sash(30mmx18mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mmx100mm long fasteners. Hardware touch lock of zinc alloyed (white powder coated), steel roller system, icluding 5mm thick glazing with selected quality glass, aluminium track on bottom rail for two track sliding frame ool pine for sliding sash and interlock Area nor exc 2.0 Sqm. Note ;- the unit rate quoted by contractor excluded cost of glass and includeds all other connected accessories. Net opening will be measured for payment purpose. | 5 | Sqm | |
23 | 23 | Taking down Chowkats or frame exc 1.5 Sqm and not exc. 4Sqm each with shutters (without taking off shutters from the frames) all as specified. \n\n | 3 | Each | |
24 | 24 | All as per srl item No 23 hereinbefore but n. exc 1.5 sqm each. | 4 | Each | |
25 | 25 | S&F 150mm long alum anodised barrel tower bolts of extended action. | 6 | Each | |
26 | 26 | S&F 50 micron reflective type sun control film sticked to glass panes as per manufacturer's instructions all as specified and as directed. | 4 | Sqm | |
27 | 27 | S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates Powder coated to them (minimum thickness of powder coating 50 microns) bates including joining cleat for fixing glazing/particle board etc. complete all as specified. | 50 | KG | |
28 | 28 | S&F Powder coated (minimum 50 microns) aluminium door shutters, aluminium sections weighing 0.55 kg/M including joining cleats,glazing clips,ruber neoprene packing handles 2 Nos in each door, hinges, anodised etc complete all as specified | 3 | sqm | |
29 | 29 | S&F 5.5 mm thick sheet glass ordinary quality, glazing and rubber beading with oil putty fixed in aluminium windows/door/partions and all as specified | 5 | sqm | |
30 | 30 | S & F only mortice lock of size 150mm long 6 levers, complete all as specified. | 3 | Each | |
31 | 31 | Door closer Aluminium Die cast hydraulically regulated designation No 3, universal type, suitable type for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixedNo 3 universal type, suitable for door shutters up to 700mm in width and of weight not more than 35 kg and fixed all as specified. | 3 | Each | |
32 | 32 | Demolition of reinforced cement concrete of any description in any position including cutting reinforcement to facilitate demolition, complete all as specified and directed. | 1.45 | Cum | |
33 | 33 | M&L for Reinforcement cement concrete (Nominal mix) 1:2:4 Type B1 (20 mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. | 1.45 | Cum | |
34 | 34 | TMT bars 6 to 8mm dia and over mild steel as in reinforcement, cut to length bent to shape required including cranking and bending with MS wire (anealed) not less than 0.9mm dia or securing with clips all as specified and directed. | 120 | kgs | |
35 | 35 | M&L in repair for anodised aluminium snap grid false ceiling of grid size 605x605mm consisting of aluminium main and "T' sectiopns of size 25x35x1.5mm thick and wall angles of size 25x 25x 1.5 mm thick suspended with GI wire suspenders of 6mm dia of suitable length and 12 mm thick perforated particle board/tiles for insulation and accoustic purposes, 60x60 cm size fixed with staples on snap grid complete all as specified and directed. | 179 | Sqm | |
36 | 36 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed. | 15 | Cum | |
37 | 37 | M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of flooring, complete all as specified and directed. | 80 | Sqm | |
38 | 38 | M &L for Rubber moulded Machine pressed precast concrete interlocking paver block(available in different colour for making patterns) any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with gray cement and pigment laid over 25mm thick sand cushioning complete all as specified and directed. | 80 | Sqm | |
39 | 39 | Factory made Pre-cast concrete blocks of size 300mmx150mm & thickness varying 150mm at bottom and 100mm at top M-20 (Design mix ) rounded or chamfered edges as in kerb stones set in CM 1:4 complete all as specified and directed | 5 | Cum | |
40 | 40 | S & F for Collapsible steel gates, top hung consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc, as specified erected in position and securing runners with holdfast and brackets complete all as specified and directed. | 5 | Sqm | |
41 | 41 | Taking down carefully copper/ aluminium point wiring (light fan socket or power) complete along with fittings such as switches, ceiling roses, Pendants regulators Tube fittings and other Kits & fittings/conduit from surface /wall . Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location. (Note ;- Serviceable fitting / fixtures will be reused in the work as directed by Engineer- in-Charge) | 42 | Each | |
42 | 42 | M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point includig cutting chasing and making good with CM 1:3 where required, complete all as specified and directed.\nin ceiling Portion surface conduit wiring to be done. \nNote : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. | 28 | Per point | |
43 | 43 | All as per item No 42 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge. | 6 | Per point | |
44 | 44 | All as per item No 42 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge. | 4 | Per point | |
45 | 45 | All as per serial item No 42 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge. | 4 | Per point | |
46 | 46 | M&L for Modular switch 1 way 6A, 1 module type all as specified and directed. | 38 | Each | |
47 | 47 | M&L for Modular switch 1 way 16A, 1 module type all as specified and directed. | 4 | Each | |
48 | 48 | Supply & Fix modular type, socket 5 pin 6 Amps, 2 modue complete all as specified. | 10 | Each | |
49 | 49 | Supply & Fix modular socket 5 pin 6/16 Amps, combination type 2 moduel complete all as specified. | 4 | Each | |
50 | 50 | Supply & fix in replacement of existing unserviceable FTL with new techonlgy self blasted LED retrofit tube lamp with thermoplastic body with high lumen 18 w 6500 K suited for installation in existing t5 tubelight including neccessary electric conection with box type batten, complete all as specified and directed. | 18 | Each set | |
51 | 51 | Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge. | 22 | Each | |
52 | 52 | Material and labour for angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 7 to 18 watts for batten fitting, complete all as specified. | 4 | Each | |
53 | 53 | Supply and fix LED Lamp LED new Adore 9W E27 W Ball Lamp 9 watt, complete all as specified and direcetd | 4 | Each | |
54 | 54 | Supply and replace environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit led luminaire comprising of high brightness leds of capacity10 Watt, complete all as specified. | 2 | Each | |
55 | 55 | M&L for replacement of existing earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I | 1 | Each | |
56 | 56 | M & L for Fan step regulator, 120W - 1 module\n | 4 | Each | |
57 | 57 | S&F in replacement sheet metal enclosures distribution boards,vertical type double door three phase 415 volts 4 ways (one incoming three phase & four out goings three phase )for MCCB,ISOLATOR&MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following \n(a)MCCB FOUR POLE 100 AMPS AC 415 VOLTS 16 KA IHLGNF0063 =01 NO as incoming\nNote :- (i) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.\n(ii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.\n(iii) All the vacant holes of the DB shall be provided with blank plates of appropriate size. | 1 | Each | |
58 | 58 | Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar. \nNote: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. \nii) The DB shall be fiush fixed and making good the disturbed surface shall be part of job at no extra cost. | 2 | Each | |
59 | 59 | Supply and fix in replacement of MCB SPN 6-32 Amp complete all as specified and directed. | 2 | Each | |
60 | 60 | Supply and fix in replacement of MCB SP up to 6-32 Amp all as specified and directed. | 16 | Each | |
61 | 61 | Taking down ceiling fan of any type of any size cleaning, dusting, oiling and greasing complete and fixing the same ceiling fan as directed by the Engr -in- Charge including replacement of three core flexible PVC conductor cable of Size 23/0.0076/ ceiling fan to ceiling rose/commector, complete all as specified and directed. | 4 | Each | |
62 | 62 | Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 4 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed.\nNote: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost. | 40 | RM | |
63 | 63 | Supply & lay in replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of crosssectional area 16 Sqmm 4 Core all as specified & directed by Engr-in-Charge. | 35 | RM | |
64 | 64 | Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. | 5 | Cum | |
65 | 65 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed. | 3.1 | Cum | |
66 | 66 | Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. | 1.9 | Cum | |
67 | 67 | Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed. | 1.5 | Cum | |
68 | 68 | Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable all as specified and directed. | 0.2 | Each per 1000 | |
69 | 69 | Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed. | 8 | RM |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy