Repair Of Elect Fittings And Fixtures Dbs With Submain Earthing Etc Reapirs Overhauling Of Ceiling Fans Air Circulators Acs Geysers Water Cooler Desert Cooler And Voltage Stablizer In Bhingar Area Ncat Area Tech Area And Resi Area At Vrde Ahmednagar, GE I R AND D GIRINAGAR PUNE 411025-Maharashtra

Military Engineer Services-MES has published Repair Of Elect Fittings And Fixtures Dbs With Submain Earthing Etc Reapirs Overhauling Of Ceiling Fans Air Circulators Acs Geysers Water Cooler Desert Cooler And Voltage Stablizer In Bhingar Area Ncat Area Tech Area And Resi Area At Vrde Ahmednagar. Submission Date for this Tender is 26-06-2020. Electrification Work Tenders in GE I R AND D GIRINAGAR PUNE 411025 Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

24438487
Corrigendum : Repair Of Elect Fittings And Fixtures Dbs With Submain Earthing Etc Reapirs Overhauling Of Ceiling Fans Air Circulators Acs Geysers Water Cooler Desert Cooler And Voltage Stablizer In Bhingar Area Ncat Area Tech Area And Resi Area At Vrde Ahmednagar
Open Tender
Indian
Maharashtra
GE I R AND D GIRINAGAR PUNE 411025
26-06-2020

Tender Details

Repair Of Elect Fittings And Fixtures Dbs With Submain Earthing Etc Reapirs Overhauling Of Ceiling Fans Air Circulators Acs Geysers Water Cooler Desert Cooler And Voltage Stablizer In Bhingar Area Ncat Area Tech Area And Resi Area At Vrde Ahmednagar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Jun-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-06-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 49000.0 /-
Tender Value
INR 24.50 Lakhs /-

BOQ Items

Name of Work: REP/REPLACEMENT OF ELECT FITTINGS & FIXTURES, DBs WITH SUBMAIN, EARTHING ETC, REPAIRS/OVERHAULING OF CEILING FANS, EXHAUST FANS, WALL FANS, AIR CIRCULATORS, ACs, GEYSERS, WATER COOLER, DESERT COOLER, REFRIGERATOR & VOLTAGE STABLIZER IN BHINGAR AREA, NCAT AREA, TECHNICAL AREA & RESIDENTIAL AREA AT VRDE AHMEDNAGAR - 06
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down carefully aluminium point wiring ( light, Fan, socket or power) complete including fixture & fitting such as switches, sockets or power socket complete fitting bracket holder, boards, and making good disturbed surfaces of walls, ceilings and floors etc complete all as specified and directed. 1 201 Per Point
2 2 Taking down unserviceable DB's any type carefully disconnecting and making good disturbed surfaces complete all as specified and directed. 2 8 Each
3 3 Taking down unserviceable switch fuse units any type carefully disconnecting and making good disturbed surfaces complete all as specified and directed. 3 4 Each
4 4 Taking down unserviceable MCBs/Isolator/DP any rating and size all as specified and directed. 4 120 Each
5 5 Taking down unserviceable Plug and socket 3 pin sheet enclosure of any rating & size all as specified and directed. 5 4 Each
6 6 Taking down old/unserviceable light fitting from wall, ceiling etc any type all as specified and directed. 6 400 Each
7 7 Material and labour for point wiring with single core PVC insulated and unsheathed 1100 volts grade FRLS electric cable with multistranded copper conductor of size 1.5 sqmm (nominal area) drawn through & including PVC casing and caping, medium duty (ISI marked) on wall, ceiling with GI screws, rawl plusgs with all fittings including tees, junction boxes & provision of pressed steel terminal box powder coated of suitable size with 3mm thick plastic laminated sheet cover for mounting switches, sockets & regulators & drawing continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5sqmm (nominal area) complete all as specified and directed by Engineer-in-Charge.(a) For one light point controlled by one single pole switch. 7 35 Per Point
8 7.01 (b) For one ceiling fan/exhaust fan/wall and wall mounted fan point controlled by one singel pole switch. 8 10 Per Point
9 7.02 (c) For one 3 pin, 5 Amp socket oultet on independent board. 9 10 Per Point
10 7.03 (d) For one 3 pin, 5 Amp socket oultet on same board with other switches. 10 15 Per Point
11 7.04 (e) For one bell/buzzer point controlled by one bell push button on independent board. 11 2 Per Point
12 7.05 (f) For one light point controlled by two 2-way switches. 12 2 Per Point
13 8 All as per serial item No 7 here-in-before, but for 3 pin socket outlet 15 Amp on independent board with other circuit with the cable of 2.5 sqmm size and earth continuity conductior of 2.5 sqmm size PVC insulated copper stranded conductor cable (Switch and socket shall be paid separately) 13 8 Per Point
14 9 All as per serial item No 7 here-in-before, but for single pole and neutaral with a two pin and earth plug and socket outlet on independent board with other circuit with the cable of 4 sqmm size and earth continuity conductior of 4 sqmm size PVC insulated copper stranded conductor cable (Sheet metal envlosure with plug & socket shall be paid separately). 14 4 Per Point
15 10 Material and labour for point wiring with single core PVC insulated and unsheathed 1100 volts grade FRLS electric cable with multistranded copper conductor of size 1.5 sqmm (nominal area) drawn through in existing surface/ recessed steel / PVC conduit, including wall clamp, tees, junction boxes where required to repair existing conduit & provision of pressed steel terminal box powder coated of suitable size with 3mm thick plastic laminated sheet cover for mounting switches, sockets & regulators & drawing continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 sqmm (nominal area) complete all as specified and directed by Engineer-in-Charge. (a) For one light point controlled by one single pole switch. 15 60 Per Point
16 10.01 (b) For one ceiling fan/exhaust fan/wall and wall mounted fan point controlled by one singel pole switch. 16 10 Per Point
17 10.02 (c) For one 3 pin, 5 Amp socket oultet on independent board. 17 15 Per Point
18 10.03 (d) For one 3 pin, 5 Amp socket oultet on same board with other switches. 18 15 Per Point
19 10.04 (e) For one bell/buzzer point controlled by one bell push button on independent board. 19 3 Per Point
20 10.05 (f) For one light point controlled by two 2-way switches. 20 2 Per Point
21 11 All as per serial item No 10 here-in-before, but for 3 pin socket outlet 15 Amp on independent board with the cable of 2.5 sqmm size and earth continuity conductior of 2.5 sqmm size PVC insulated copper stranded conductor cable (Switch and socket shall be paid separately) 21 10 Per Point
22 12 Supply and fixing socket outlet 6 pin 15 Amps flush type complete all as specified and as directed by Engineer-in-Charge. 22 18 Each
23 13 Supply and fixing socket outlet 5 pin 5 Amps flush type complete all as specified and as directed by Engineer-in-Charge. 23 55 Each
24 14 Supply and fixing switch piano, flush button 15 Amps single pole, one way complete all as specified and directed by Engineer-in-Charge. 24 18 Each
25 15 Supply and fixing switch piano, flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-Charge. 25 170 Each
26 16 S&F bell push flush type 5 Amp. 26 5 Each
27 17 S & F bell, AC 230 V, single pole. 27 5 Each
28 18 Supply and fixing ceiling rose, surface, backlite 2 to 3 terminals 65mm x 50mm complete all as specified and directed by Engineer-in-Charge. 28 115 Each
29 19 Supply and fixing stepped type electronic fan regulator complete all as specified and directed by Engineer-in-Charge. 29 20 Each
30 20 S&F lamp holder 230 volt, AC, PVC/polycarbonate type with back plate suitable for batten fitting all as specified and as directed. 30 10 Each
31 21 Supply and fixing sheet metal enclosure (for AC's / equipment ) single pole and neutaral with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 volts complete all as specified and directed by Engineer-in-Charge. 31 4 Each
32 22 Taking down old aluminium unserviceable sub main wiring any type complete all as specified and as directed. 32 150 RM
33 23 Material and labour for sub main wiring with two single core PVC insualted unsheathed stranded copper conductor cable 4 sqmm size drawn through existing surface/recessed/consealed PVC/steel conduit with all accessories including continuous earth wire PVC insualted unsheathed cable 4 sqmm copper stranded conductor and connection to common earth and earth dolly including conneciting to main board complete all as specifed and directed by the Enginieer -in-Charge. 33 75 RM
34 24 All as per above item No-23 of 6 sqmm and one run of 6 sqmm as earth wire 34 50 RM
35 25 All as per above item No-23 but four run of 6 sqmm and one run of 6 sqmm as earth wire including with new PVC conduit. 35 25 RM
36 26 Supply and fixing in replacement LED batten suitable for mount LED tube rod 1x18 watt including necessary electric connections with flexible copper cable 23/0.0076 from ceiling rose to tube light fitting complete. Make : Bajaj, Cat Part No- BLRB-DB118 or equivalent of Crompton/philips/Wipro. 36 150 Each
37 27 Supply and fixing in replacement LED tube rod 18 watt complete including remove electronic/copper ballast from existing batten and make necessary electric connections with suitable size of copper wire all as specified and directed by the Engineer-in-Charge. Make :Bajaj, Cat Part No-BLRB-18W CW LED or equivalent of Crompton/philips/Wipro. 37 785 Each
38 28 Supply and fixing energy saving recessed mounting LED 36 watt low glare luminaries suitable for 600mm x 600mm modular/POP/Gypsum ceiling, false ceiling type with all accessoreis pre-wired complete all as specified and directed by Engineer-in-Charge. Make - Bajaj, Cat Part No-BZRSQL 36W GZ1 CW or equivalent of Crompton/philips/Wipro. 38 40 Each
39 29 Supply and fixing LED batten light 10 watt mirror light fitting wall mounted with tubelight including making necessary electrical connection to the fitting using flexible copper cable 3 core 23/0.0076 from ceiling rose to light fitting complete all as specified and directed by the Engineer-in-Charge. Make-Bajaj, Cat Part No- BCLSB-10WH or equivalent of crompton/philips/Wipro. 39 150 Each
40 30 Supply and fixing surface mounting round/square LED down light 12 watt luminaires including making necessary electrical connection to the fitting using flexible copper cable 3 core 23/0.0076 from ceiling rose to light fitting complete all as specified and directed by the Engineer-in-Charge. Make-Bajaj, Cat Part No- BGCML12 WH or equivalent of crompton/philips/Wipro. 40 20 Each
41 31 Supply and fix in repair LED security light 1x25 W IP 66 pressure die cast aluminium housing for building complete including mounting bracket with clamps, nuts, bolts and washers with necessary electrical connection. Make - Bajaj, Cat Part No-BCLST 25W LED V2 or equivalent of Crompton/philips/Wipro. 41 40 Each
42 32 Supply and fixing sheet steel enclosure MCB DB's factory fabricated phosphatised powder painted,Single pole & neutral, with 200 Amp rated bus-bar, 240 volt, AC ,8 ways, double door type complete all as specified and directed by Engineer-in-Charge. 42 2 Each
43 33 All as per serial item No 32 but SPN 12 way double door. 43 2 Each
44 34 Supply and fixing sheet steel enclosure MCB DB's factory fabricated phosphatised powder painted, tripple pole & neutral, with 200 Amp rated bus-bar, 415 volt, AC , 4 ways, double door type complete all as specified and directed by Engineer-in-Charge. 44 2 Each
45 35 All as per serial item No 34 but TPN 8 way double door. 45 1 Each
46 36 Supply and fixing MCB, Single pole 6-32 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge. Make -L&T or equivalent of Crompton/havells/indoasian. 46 75 Each
47 37 Supply and fixing MCB, Single pole and neutral, 32 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge. Make -L&T or equivalent of Crompton/ havells /indoasian. 47 15 Each
48 38 All as per serial item No 37 but SPN 63 Amps. Make -L&T or equivalent of Crompton/havells/indoasian. 48 5 Each
49 39 Supply and fixing MCB, triple pole and neutral, 63 Amps, 415 volts complete all as specified and directed by Engineer-in-Charge. Make -L&T or equivalent of Crompton/ havells/indoasian. 49 10 Each
50 40 All as per serial item No 39 but TP 63 Amps. Make -L&T or equivalent of Crompton/havells/indoasian. 50 15 Each
51 41 Supply and fix sheet metal enclosure industrial type complete with plug and socket 5 pin ( 3 phase+1 N+1E) including three pole MCB 32 Amps breaking capacity 6 kA complete all as specified and directed by Engr-in charge. 51 1 Each
52 42 Supply and fixing of switch fuse unit in sheet metal enclosure TPN 32 Amps, 415 V, AC 50 Hz, rotary type handle with fuse complete all as specified. Make : L&T or equivalent of Havells/crompton/Indoasian 52 2 Each
53 43 -ditto- all as per above item No 42 but TPN 63 Amps. 53 1 Each
54 44 Supply and fixing vertical type TPN load line sheet metal Distribution board double door for housing MCCB and MCB triple pole, 4 way complete with bus bar and including with incomer MCCB 100 amps 3 Pole , breaking capacity 16 kA- 01 Nos all as specifed and as directed by Engineer-in-Charge. Make : L&T or equivalent of Havells/Crompton/Indoasian Note - MCB's will be measured and paid as separate item. 54 1 Each
55 45 All as per above item No-44 but TP 8 way. 55 1 Each
56 46 Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre deep below ground level with top edge of the plate not less than 1.5 metre below normal ground level and connected to earth plate surrounded by 15cm thick packed layers of charcoal dust and common salt and conected to GI wire 4mm dia by means of bolts, nuts check nuts and wahsers of galvaised iron or steel and thimbles and otehr end of the earth wire connected to DB and protected by galvaised iron or steel pipe light grade 15mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and Rcc cover all as shown in Electrical Plate No 3. 56 30 Each Set
57 47 All as per above item No-46 but using 25x4mm as earthing lead. 57 2 Each Set
58 48 Supply and fix in replacement of energy saving, enviromental friendly highbay fitting with highpower COM LED as light source of 120 W all as directed by Engr- in -charge. Make: Bajaj cat Part No : BGPPH 120 W LED or equivalent of Crompton/philips/Wipro. 58 12 Each
59 49 Supply only LED PL 4 pin 15 Watt tube complete. Make - Bajaj Cat part No- BLL15W LED 2G11 or equivalent of Crompton/philips/Wipro. 59 100 Each
60 50 Supply only Switch socket combination 5 amp 5 pin. 60 200 Each
61 51 Supply only Switch socket combination 15 amp 5 pin universal. 61 200 Each
62 52 Supply only Flexible copper wire 23/0.0076 PVC sheathed. 62 300 RM
63 53 Supply only PVC Box of size 7" x 8" 63 15 Each
64 54 Supply only PVC Box of size 4.5" x 3" suitable for 15 amp switch-socket 64 15 Each
65 55 Supply only LED tube rod 18 watt, 4 feet cool white Make - Bajaj, Cat Part No--BLRB-18W CW LED or equivalent of Crompton/philips/Wipro. 65 500 Each
66 56 Supply only LED batten with tube 10 watt fitting. Make-Bajaj, Cat Part No- BCLSB-10WH or equivalent of crompton/philips/Wipro. 66 60 Each
67 57 Supply only PVC aluminium service cable twin core 6 Sqmm weather proof. 67 600 RM
68 58 Supply only step type electronic fan regulator flush type suitable for 1200/1400mm sweep fan. 68 200 Each
69 59 Supply only insulation tape size 2.5cm x 25 mtr x .125mm 69 80 Each Roll
70 60 Supply only switch piano type 5/6 Amp one way. 70 300 Each
71 61 Supply only pulg top 6 Amps 71 20 Each
72 62 Supply only pulg top 16 Amps with indicator. 72 40 Each
73 63 Supply only Power unit combo 20 Amps MCB protected socket with PVC junction box. 73 20 Each
74 64 Supply only 6/16 Amps switch socket combination with PVC junction box. 74 10 Each
75 65 Supply only cable PVC FRLS insulated unsheathed stranded copper conductor 1.5 Sqmm 75 450 RM
76 66 Supply only cable PVC FRLS insulated unsheathed stranded copper conductor 2.5 Sqmm 76 360 RM
77 67 Supply only cable PVC FRLS insulated unsheathed stranded copper conductor 4 Sqmm 77 180 RM
78 68 Supply only cable PVC FRLS insulated unsheathed stranded copper conductor 6 Sqmm 78 90 RM
79 69 Supply only PVC sheathed copper cable 2.5 Sqmm 3 Core. 79 300 RM
80 70 Supply only MCB SP 6-32 Amps 80 75 Each
81 71 Supply only MCB SPN 40 Amps 81 40 Each
82 72 Supply only MCB TPN 63 Amps 82 30 Each
83 73 Supply only MCB TP 63 Amps 83 30 Each
84 74 Supply only fan condensor 2.5 mfd. Make : EPCOS/Asian 84 150 Each
85 75 Supply only casing capping size 20 mm ISI marked medium grade. 85 70 RM
86 76 Taking down the defective ceiling fan of 1200/1400 mm sweep any make any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running including servicing/overhauling the ceiling fan by throughly cleaning the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly. (Note : Spare parts will be measured & paid as separate items) 86 150 Each
87 77 Re-winding the ceiling fan 1200/1400 mm sweep with same guage supper enamelled copper wire complete all as specified and as directed. 87 80 Each
88 78 Taking down the defective Exhaust fan 300 mm sweep any make and any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running including servicing/overhauling the exhaust fan by throughly cleaning the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly. (Note : Spare parts will be measured & paid as separate items) 88 65 Each
89 79 Re-winding the exhaust fan with same guage supper enamelled copper wire complete all as specified and as directed. 89 25 Each
90 80 Taking down the defective Exhaust fan 450 mm sweep any make any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running including servicing/overhauling the exhaust fan by throughly cleaning the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly. (Note : Spare parts will be measured & paid as separate items) 90 40 Each
91 81 Re-winding the exhaust fan with same guage supper enamelled copper wire complete all as specified and as directed. 91 20 Each
92 82 Taking down the defective Wall mounted fan 450 mm sweep any make any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running including servicing/overhauling the Wall mounted fan by throughly cleaning the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly. (Note : Spare parts will be measured & paid as separate items) 92 15 Each
93 83 Re-winding the wall fan with same guage supper enamelled copper wire complete all as specified and as directed. 93 10 Each
94 84 Taking down the defective Air circulator fan 600 mm sweep any make any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running includingservicing/overhauling the Air circulator fan by throughly cleaning the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly. (Note : Spare parts will be measured & paid as separate items) 94 35 Each
95 85 Re-winding the air circulator fan with same guage supper enamelled copper wire complete all as specified and as directed. 95 15 Each
96 86 Supplying only of ball bearing suitable for exhaust fan,up to 450 mm size complete all as specified and as directed.MAKE : NBC, SKF or equivalent make as approved by GE. 96 50 Each
97 87 Supplying only of ball bearing suitable for ceiling fan complete all as specified and as directed. MAKE : NBC, SKF or equivalent make as approved by GE. 97 80 Each
98 88 Supplying only of gun metal bush suitable for ceiling fan, any sweep complete all as specified and as directed. 98 20 Each
99 89 Supply & fix of fan hanging mild steel ‘U’ clamps of suitable size duly painted for hanging of ceiling fan with nuts, bolts, split pins and rubber real complete all as specified and as directed. 99 10 Each
100 90 Supply and fix in repairs fan condensor 2.5 mfd. Make : EPCOS/Asian 100 100 Each
101 91 Inspection and maintenance of water heater (Geysers) of capacity, 25 ltrs to 50 litres including performing the following task at different locations at VRDE.\n(a) Removing the heather plate assembly and descaling the heating element/pipe either by use of acid or equa cleaner to make it functional complete.\n(b) Checking and setting of thermostat between 70 to 80 degree Celsius.\n(c) Check working of NRV stop cock, pressure release valve and servicing carefully to make it functional.\n(d) Repairing of earthing connection, power switch, socket connection replacement of indicator lamp to make it functional.\n(e) Examine water leakage and rectifying as required and replacement of rubber washer gasket etc to make it functional.\n(f) Inspect over flow vent pipe, safety valve and remove blockage if required to make it functional. 101 10 Each
102 92 Supply & fix of heating element of rating 2 KW to geyser 25 to 50 litres capacity, any type, complete all as specified and as directed. 102 5 Each
103 93 Supply & fix of heating element of rating 1.5 KW to geyser 25 to 50 litres capacity, any type, complete all as specified and as directed. 103 5 EACH
104 94 Supply & fix of the thermostat (adjustable type) suitable for upto 50 litres capacity of geysers. 104 10 Each
105 95 Supplying and fixing in replacement of geyser plate assembly suitable for 25 to 50 litres capacity geysers, of brass with inlet, outlet pipe, drain plug, thermostat chamber fixing heating element gasket nut, bolt etc are fixing the assembly to make it functional complete all as specified and as directed. 105 2 Each
106 96 Supply & fixof flexible PVC pipe connection, heavy duty nylon thread reinforced 15 mm dia, 450 mm long with brass union at both ends for 15 mm dia pipe complete all as specified and as directed. 106 12 Each
107 97 Supply & Fix gasket of thickness 5 mm for geyser assembly of 08 holes/09 holes complete all as specified & directed.. 107 5 Each
108 98 Supply & Fix metal clad top & socket 15 Amp cap complete all as directed. 108 5 Each
109 99 S&F non return valve for geyser all as directed. 109 3 Each
110 100 Supply & fix fastner mild steel 100/150/200 mm long complete all as specified & directed. 110 16 Each
111 101 Dismantling/taking out the geyser assembly & copper tank and making soldering & brazing of tank and fixing the same in the geyser of any cap. 111 8 Each Job
112 102 Taking down /out from existing position window type AC's of capacity 1.5/2TR, servicing the same by cleaning, dusting with blower, checking wiring, nuts, bolts, electrical contacts, tightening all loosened parts as required,setting grills and fan blades for proper functioning, oiling, greasing to moving parts including replacing defective parts and sleaves etc and refixing the same to its original position and testing for smooth functioning complete all as specified and as directed. 112 50 Each Job
113 103 Taking down /out from existing position split type AC's indoor & outdoor units of capacity 1.5/2TR, servicing the same by cleaning, dusting with blower, checking wiring, nuts, bolts, electrical contacts, tightening all loosened parts as required,setting grills and fan blades for proper functioning, oiling, greasing to moving parts including replacing defective parts and sleaves etc and refixing the same to its original position and testing for smooth functioning complete all as specified and as directed. 113 45 Each Job
114 104 All as per item No 103 above but refigerator & deep freezer capacity 165 ltrs to 350 ltrs complete all as specified and directed by Engr- in- Charge. 114 3 Each Job
115 105 All as per item No 103 above but water cooler capacity 40 ltrs to 150 ltrs complete all as specified and directed by Engr- in- Charge. 115 10 Each Job
116 106 All as per item No 103 above but desert cooler capacity of any capacity upto 5000 cum including washing with water complete all as specified and directed by Engr- in- Charge. 116 45 Each Job
117 107 Disconnecting burnt out compressor from existing electric and pipe line connections of refrigerator of capacity 300/350 ltr of any make and replacing the same with factory made reconditioned compressor including connecting suction and discharge line by cooler brazing. 117 1 Each Job
118 108 All as per item No 107 above but water cooler of capacity 40/80 ltrs complete all as specified and as directed. 118 1 Each Job
119 109 All as per item No 107 above but water cooler of capacity 60/120/150 ltrs complete all as specified and as directed. 119 1 Each Job
120 110 All as per item No 107 above but Window / Split type AC of capacity 1.5 TR complete all as specified and as directed. 120 2 Each Job
121 111 All as per item No 107 above but Window / Split type AC of capacity 2 TR complete all as specified and as directed. 121 2 Each Job
122 112 S&F in replacement condensor fan motor for water coolers any capacity.suitable for water cooler of capacity 40/80, 60/120 & 60/150 liters 122 1 Each Job
123 113 S&F in replacement blower fan motor for window AC of capacity 1.5 TR complete all as specified and as directed. 123 1 Each Job
124 114 S&F in replacement blower fan motor for window AC of capacity 2 TR complete all as specified and as directed. 124 1 Each Job
125 115 S&F in replacement blower fan motor for split type AC in door unit of capacity 1.5 TR complete all as specified and as directed. 125 1 Each Job
126 116 S&F in replacement blower fan motor for split type AC in door unit of capacity 2 TR complete all as specified and as directed. 126 1 Each Job
127 117 S&F in replacement condensor motor for split type AC out door unit of capacity 1.5 TR complete all as specified and as directed. 127 1 Each Job
128 118 S&F in replacement condensor motor for split type AC out door unit of capacity 2 TR complete all as specified and as directed. 128 1 Each Job
129 119 S&F in replacement fan motor of 230 volt, 50 Hz, SP suitable for desert cooler of capacity 3000/5000 cum per hour complete all as specified and as directed. 129 2 Each Job
130 120 Supply and charging only refrigerent gas of required HD ie Hydrocarbon, 134, R-22 or R-12 or any latest version for refrigerators of capacity 310 lts including cutting copper pipe and sealing by brazing etc after charging gas as required and leak testing complete all asspecified and as directed. 130 1 Each Job
131 121 All as per item No 120 above but for water coolers of capacity 40/80, 60/120, 150/150 ltr capacity complete all as specified and as directed. 131 5 Each Job
132 122 All as per item No 120 above but for window/split type AC of capacity 1.5 TR complete all as specified and as directed. 132 30 Each Job
133 123 All as per item No 120 above but for window/split type AC of capacity 2 TR complete all as specified and as directed. 133 30 Each Job
134 124 Supply only in replacement running/starter capacitor 2.5/3.15/4.0/6.0 mfd, 230 volt, AC for cooling appaliances complete all as specified and as directed. 134 18 Each
135 125 All as per item No 124 above but of 10.0/15.0 mfd complete all as aspecified and as directed. 135 8 Each
136 126 All as per item No 124 above but of 36.0/45.0 mfd complete all as aspecified and as directed. 136 16 Each
137 127 All as per item No 124 above but of 40.0/60.0 mfd complete all as aspecified and as directed. 137 4 Each
138 128 Supply only in replacement thermostate suitable for window/split type AC's water coolers, Refrigerators and Deep freezers of any make, capacity and model and testing complete all as specified and as directed. 138 15 Each
139 129 Supply and fix in replacement over load protector suitable for window/split type AC's, water coolers, Refrigerators and Deep freezers of any make, capacity and model and testing complete all as specified and as directed. 139 4 Each
140 130 Supply and fixing in replacement box type relay or package assembly from suitable window type AC's of capacity 1.5/2 TR complete all as specified and as directed. 140 4 Each
141 131 All as per item No 130 above but for split type AC's of capacity 1.5/2 TR complete all as aspecified and as directed. 141 4 Each
142 132 All as per item No 130 above but for water coolers capacity 40/80, 60/120 & 60/150 ltrs complete all as aspecified and as directed. 142 2 Each
143 133 S&F in replacement 15mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed in water coolers complete all as aspecified and as directed. 143 4 Each
144 134 S&F in replacement push cock, 15mm dia, chromium plated self closing type complete all as aspecified and as directed. 144 4 Each
145 135 S&F in replacement 15mm dia stop valve, cromium plated screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as aspecified and as directed. 145 5 Each
146 136 S&F in replacement PVC connection 600 mm long with brass ends terminals suitable for water coolers complete all as aspecified and as directed. 146 10 Each
147 137 S&F in replacement PVC pipe 32mm dia for draining out waste water complete all as aspecified and as directed. 147 35 RM
148 138 S&F in replacement fan blade set for water coolers fan motor complete all as aspecified and as directed. 148 2 Each
149 139 Supply and fixing in replacement Plug top 3 pin, 230 volt 6 Amps. 149 10 Each
150 140 Supply and fixing in replacement Plug top 3 pin, 230 volt 16 Amps. 150 20 Each
151 141 Supply and fixing in replacement Air filter PVC type of existing window / split type AC's of capacity 1.5/2 TR complete. 151 5 Each
152 142 S&F in replacement PVC insulated cable 3 core 2.5 Sqmm, 1100 volts grade copper conductor, multistranded including testing complete all as specified and as directed. 152 90 RM
153 143 All as per item No 142 above but 3 core 1.5 Sqmm. 153 90 RM
154 144 S&F in replacement Heatlion insulation pipe for wrapping copper tape duly fixed with polythelene type to suction and discharge lines for existing window/split type AC's 1.5/2 TR from any position or any make including testing complete all as specified and as directed. 154 25 RM
155 145 S&F in replacement Electronic card of existing window/split type AC's of capacity 1.5 / 2 TR including testing complete all as specified and as directed. 155 2 Each
156 146 Supply only of wood wool pads of best quality as approved with and including wire mesh jalli for desert cooler of any size make and capacity all as specified and as directed. 156 30 Each set of three
157 147 S&F in replacement water pump, 230 volt, 50 Hz, SP with discharge head 1.87 mtr for desert cooler of any capacity complete all as specified and as directed. 157 15 Each
158 148 M&L for vacuuming complete system of central/ package type air conditioning plant with double stage vacuum pump of (-) 2Kg/cm² vacuum pressure after repairs to compressor or repair in refrigeration system, charging the dry nitrogen gas, R-22 and hold up to 24 hrs and rectifing the leackage if any by repairing the "O" ring and gland packing of service valve/ Oil seal including top up the compressor oil and charging the refrigerant gas (R-22) at various plant all as specified and directed by Eng-in-charge.\na) Central type AC Plant at Emission Lab (3x11 TR) 158 1 Job
159 148.01 b) Central type AC Plant at Emission Lab (2x11 TR) 159 1 Job
160 148.02 c) Package type AC Plant (4x8.5 TR) 160 1 Job
161 149 Supply only of R-22 refrigerent gas to central AC system and package AC plant, testing for leakage in system and commissioning all as specified and directed by Engr-in-charge. 161 45 Kg
162 150 Supply only nitrogen gas for leak testing of central AC / package AC plant system. 162 20 Kg
163 151 Supply only of compressure oil N-68 after flushing compressure and testing commissioning all as directed by Engr-in-charge. 163 20 Ltr
164 152 S&F in replacement drier filter DL-100 for liquid line of package type AC plant all as specified and directed by Engr-in-Charge. 164 2 Each
165 153 S&F in replacement of scroll type hermetically sealed compressor 4.25 TR capacity 3 phase, 50 Hz, 380/420V with R22 for package AC plant. 165 1 Each
166 154 To attend any break down & checking the electrical connections & wiring of equipment and rectify the problem of summer appliances ie. Split type AC's, window type AC's, water coolers, refrigerator of any capacity or make/model, installed at VRDE complex as and when required during working/non working hours all as directed by Engr-in-charge. Note :- (i) Spares will be measured and paid separately under relevent items. (ii) complaint if not attended with in 24 hrs after receiving complaint, panelty will be recovered at double by the contractor. 166 65 Each
167 155 Taking down/out the blower/condensor fan motor of any make and capacity, transporting to workshop, opening up, cleaning, taking out burnt winding etc, and rewinding of motor with superior quality of enamelled copper wire of same guage, reassembling and fixing back at the same position including testing and making necessary connection complete all as specified and as directed. \n(a) Blower fan motor (Two speed i.e. low and high for window type AC of capacity 1/5 HP capacity) 167 1 Each
168 155.01 (b) Condensor fan motor for water cooler1/6 HP Capacity. 168 1 Each
169 155.02 (c) Air cooler fan motor having three speed, single phase 230 volts, 50 Hz of 380 to 450mm sweep. 169 1 Each
170 155.03 (d) Condensor fan motor for split type AC of capacity 1.5 TR. 170 1 Each
171 155.04 (e) Blower fan motor for split type AC of capacity 1.5 TR. 171 1 Each
172 155.05 (f) Condensor fan motor for split type AC of capacity 2 TR. 172 1 Each
173 155.06 (g) Blower fan motor for split type AC of capacity 2 TR. 173 1 Each
174 156 Taking down/out window / split type AC 1.5/2 TR capacity of any make, from existing position, transporting and refixing at new location including making necessary connections to make it functional complete all as specified and directed.\nNote : Gas charging and/or parts if required shall be measured and paid separetely. 174 12 Each Job
175 157 Detecting gas leakage of water cooler, refrigerators, deep freezers, window type AC's and split type AC's and rectifying / arresting the leakages, testing for pressure drop complete all as specified and as directed.\nNote : Gas charging shall be measured and paid separetely. 175 45 Each
176 158 S&F in replacement PCB unit for remote control including remote for AC unit complete all as specified and directed. 176 1 Each
177 159 S&F in repair selector switch 3 way for AC 1.5/2 ton all as directed. 177 4 Each
178 160 Dismantling the voltage stabilizer 230/250 Volts 1 KVA and reassembling the same after servicing & tightening the electrical connection & replacing the u/s parts as required and make it functional complete all as specified & directed. 178 2 Each Job
179 161 All as per item No.160 above but 2.0 KVA cap. 179 2 Each Job
180 162 All as per item No. 160 above but 3.0 KVA cap. 180 2 Each Job
181 163 All as per item No.160 above but 5.0 KVA cap. 181 2 Each Job
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail