Military Engineer Services-MES has published Repair Of Elect Fittings And Fixtures Dbs With Submain Earthing Etc Reapirs Overhauling Of Ceiling Fans Air Circulators Acs Geysers Water Cooler Desert Cooler And Voltage Stablizer In Bhingar Area Ncat Area Tech Area And Resi Area At Vrde Ahmednagar. Submission Date for this Tender is 26-06-2020. Electrification Work Tenders in GE I R AND D GIRINAGAR PUNE 411025 Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 19-Jun-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-06-2020 |
Name of Work: REP/REPLACEMENT OF ELECT FITTINGS & FIXTURES, DBs WITH SUBMAIN, EARTHING ETC, REPAIRS/OVERHAULING OF CEILING FANS, EXHAUST FANS, WALL FANS, AIR CIRCULATORS, ACs, GEYSERS, WATER COOLER, DESERT COOLER, REFRIGERATOR & VOLTAGE STABLIZER IN BHINGAR AREA, NCAT AREA, TECHNICAL AREA & RESIDENTIAL AREA AT VRDE AHMEDNAGAR - 06 | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down carefully aluminium point wiring ( light, Fan, socket or power) complete including fixture & fitting such as switches, sockets or power socket complete fitting bracket holder, boards, and making good disturbed surfaces of walls, ceilings and floors etc complete all as specified and directed. | 1 | 201 | Per Point |
2 | 2 | Taking down unserviceable DB's any type carefully disconnecting and making good disturbed surfaces complete all as specified and directed. | 2 | 8 | Each |
3 | 3 | Taking down unserviceable switch fuse units any type carefully disconnecting and making good disturbed surfaces complete all as specified and directed. | 3 | 4 | Each |
4 | 4 | Taking down unserviceable MCBs/Isolator/DP any rating and size all as specified and directed. | 4 | 120 | Each |
5 | 5 | Taking down unserviceable Plug and socket 3 pin sheet enclosure of any rating & size all as specified and directed. | 5 | 4 | Each |
6 | 6 | Taking down old/unserviceable light fitting from wall, ceiling etc any type all as specified and directed. | 6 | 400 | Each |
7 | 7 | Material and labour for point wiring with single core PVC insulated and unsheathed 1100 volts grade FRLS electric cable with multistranded copper conductor of size 1.5 sqmm (nominal area) drawn through & including PVC casing and caping, medium duty (ISI marked) on wall, ceiling with GI screws, rawl plusgs with all fittings including tees, junction boxes & provision of pressed steel terminal box powder coated of suitable size with 3mm thick plastic laminated sheet cover for mounting switches, sockets & regulators & drawing continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5sqmm (nominal area) complete all as specified and directed by Engineer-in-Charge.(a) For one light point controlled by one single pole switch. | 7 | 35 | Per Point |
8 | 7.01 | (b) For one ceiling fan/exhaust fan/wall and wall mounted fan point controlled by one singel pole switch. | 8 | 10 | Per Point |
9 | 7.02 | (c) For one 3 pin, 5 Amp socket oultet on independent board. | 9 | 10 | Per Point |
10 | 7.03 | (d) For one 3 pin, 5 Amp socket oultet on same board with other switches. | 10 | 15 | Per Point |
11 | 7.04 | (e) For one bell/buzzer point controlled by one bell push button on independent board. | 11 | 2 | Per Point |
12 | 7.05 | (f) For one light point controlled by two 2-way switches. | 12 | 2 | Per Point |
13 | 8 | All as per serial item No 7 here-in-before, but for 3 pin socket outlet 15 Amp on independent board with other circuit with the cable of 2.5 sqmm size and earth continuity conductior of 2.5 sqmm size PVC insulated copper stranded conductor cable (Switch and socket shall be paid separately) | 13 | 8 | Per Point |
14 | 9 | All as per serial item No 7 here-in-before, but for single pole and neutaral with a two pin and earth plug and socket outlet on independent board with other circuit with the cable of 4 sqmm size and earth continuity conductior of 4 sqmm size PVC insulated copper stranded conductor cable (Sheet metal envlosure with plug & socket shall be paid separately). | 14 | 4 | Per Point |
15 | 10 | Material and labour for point wiring with single core PVC insulated and unsheathed 1100 volts grade FRLS electric cable with multistranded copper conductor of size 1.5 sqmm (nominal area) drawn through in existing surface/ recessed steel / PVC conduit, including wall clamp, tees, junction boxes where required to repair existing conduit & provision of pressed steel terminal box powder coated of suitable size with 3mm thick plastic laminated sheet cover for mounting switches, sockets & regulators & drawing continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 sqmm (nominal area) complete all as specified and directed by Engineer-in-Charge. (a) For one light point controlled by one single pole switch. | 15 | 60 | Per Point |
16 | 10.01 | (b) For one ceiling fan/exhaust fan/wall and wall mounted fan point controlled by one singel pole switch. | 16 | 10 | Per Point |
17 | 10.02 | (c) For one 3 pin, 5 Amp socket oultet on independent board. | 17 | 15 | Per Point |
18 | 10.03 | (d) For one 3 pin, 5 Amp socket oultet on same board with other switches. | 18 | 15 | Per Point |
19 | 10.04 | (e) For one bell/buzzer point controlled by one bell push button on independent board. | 19 | 3 | Per Point |
20 | 10.05 | (f) For one light point controlled by two 2-way switches. | 20 | 2 | Per Point |
21 | 11 | All as per serial item No 10 here-in-before, but for 3 pin socket outlet 15 Amp on independent board with the cable of 2.5 sqmm size and earth continuity conductior of 2.5 sqmm size PVC insulated copper stranded conductor cable (Switch and socket shall be paid separately) | 21 | 10 | Per Point |
22 | 12 | Supply and fixing socket outlet 6 pin 15 Amps flush type complete all as specified and as directed by Engineer-in-Charge. | 22 | 18 | Each |
23 | 13 | Supply and fixing socket outlet 5 pin 5 Amps flush type complete all as specified and as directed by Engineer-in-Charge. | 23 | 55 | Each |
24 | 14 | Supply and fixing switch piano, flush button 15 Amps single pole, one way complete all as specified and directed by Engineer-in-Charge. | 24 | 18 | Each |
25 | 15 | Supply and fixing switch piano, flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-Charge. | 25 | 170 | Each |
26 | 16 | S&F bell push flush type 5 Amp. | 26 | 5 | Each |
27 | 17 | S & F bell, AC 230 V, single pole. | 27 | 5 | Each |
28 | 18 | Supply and fixing ceiling rose, surface, backlite 2 to 3 terminals 65mm x 50mm complete all as specified and directed by Engineer-in-Charge. | 28 | 115 | Each |
29 | 19 | Supply and fixing stepped type electronic fan regulator complete all as specified and directed by Engineer-in-Charge. | 29 | 20 | Each |
30 | 20 | S&F lamp holder 230 volt, AC, PVC/polycarbonate type with back plate suitable for batten fitting all as specified and as directed. | 30 | 10 | Each |
31 | 21 | Supply and fixing sheet metal enclosure (for AC's / equipment ) single pole and neutaral with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 volts complete all as specified and directed by Engineer-in-Charge. | 31 | 4 | Each |
32 | 22 | Taking down old aluminium unserviceable sub main wiring any type complete all as specified and as directed. | 32 | 150 | RM |
33 | 23 | Material and labour for sub main wiring with two single core PVC insualted unsheathed stranded copper conductor cable 4 sqmm size drawn through existing surface/recessed/consealed PVC/steel conduit with all accessories including continuous earth wire PVC insualted unsheathed cable 4 sqmm copper stranded conductor and connection to common earth and earth dolly including conneciting to main board complete all as specifed and directed by the Enginieer -in-Charge. | 33 | 75 | RM |
34 | 24 | All as per above item No-23 of 6 sqmm and one run of 6 sqmm as earth wire | 34 | 50 | RM |
35 | 25 | All as per above item No-23 but four run of 6 sqmm and one run of 6 sqmm as earth wire including with new PVC conduit. | 35 | 25 | RM |
36 | 26 | Supply and fixing in replacement LED batten suitable for mount LED tube rod 1x18 watt including necessary electric connections with flexible copper cable 23/0.0076 from ceiling rose to tube light fitting complete. Make : Bajaj, Cat Part No- BLRB-DB118 or equivalent of Crompton/philips/Wipro. | 36 | 150 | Each |
37 | 27 | Supply and fixing in replacement LED tube rod 18 watt complete including remove electronic/copper ballast from existing batten and make necessary electric connections with suitable size of copper wire all as specified and directed by the Engineer-in-Charge. Make :Bajaj, Cat Part No-BLRB-18W CW LED or equivalent of Crompton/philips/Wipro. | 37 | 785 | Each |
38 | 28 | Supply and fixing energy saving recessed mounting LED 36 watt low glare luminaries suitable for 600mm x 600mm modular/POP/Gypsum ceiling, false ceiling type with all accessoreis pre-wired complete all as specified and directed by Engineer-in-Charge. Make - Bajaj, Cat Part No-BZRSQL 36W GZ1 CW or equivalent of Crompton/philips/Wipro. | 38 | 40 | Each |
39 | 29 | Supply and fixing LED batten light 10 watt mirror light fitting wall mounted with tubelight including making necessary electrical connection to the fitting using flexible copper cable 3 core 23/0.0076 from ceiling rose to light fitting complete all as specified and directed by the Engineer-in-Charge. Make-Bajaj, Cat Part No- BCLSB-10WH or equivalent of crompton/philips/Wipro. | 39 | 150 | Each |
40 | 30 | Supply and fixing surface mounting round/square LED down light 12 watt luminaires including making necessary electrical connection to the fitting using flexible copper cable 3 core 23/0.0076 from ceiling rose to light fitting complete all as specified and directed by the Engineer-in-Charge. Make-Bajaj, Cat Part No- BGCML12 WH or equivalent of crompton/philips/Wipro. | 40 | 20 | Each |
41 | 31 | Supply and fix in repair LED security light 1x25 W IP 66 pressure die cast aluminium housing for building complete including mounting bracket with clamps, nuts, bolts and washers with necessary electrical connection. Make - Bajaj, Cat Part No-BCLST 25W LED V2 or equivalent of Crompton/philips/Wipro. | 41 | 40 | Each |
42 | 32 | Supply and fixing sheet steel enclosure MCB DB's factory fabricated phosphatised powder painted,Single pole & neutral, with 200 Amp rated bus-bar, 240 volt, AC ,8 ways, double door type complete all as specified and directed by Engineer-in-Charge. | 42 | 2 | Each |
43 | 33 | All as per serial item No 32 but SPN 12 way double door. | 43 | 2 | Each |
44 | 34 | Supply and fixing sheet steel enclosure MCB DB's factory fabricated phosphatised powder painted, tripple pole & neutral, with 200 Amp rated bus-bar, 415 volt, AC , 4 ways, double door type complete all as specified and directed by Engineer-in-Charge. | 44 | 2 | Each |
45 | 35 | All as per serial item No 34 but TPN 8 way double door. | 45 | 1 | Each |
46 | 36 | Supply and fixing MCB, Single pole 6-32 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge. Make -L&T or equivalent of Crompton/havells/indoasian. | 46 | 75 | Each |
47 | 37 | Supply and fixing MCB, Single pole and neutral, 32 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge. Make -L&T or equivalent of Crompton/ havells /indoasian. | 47 | 15 | Each |
48 | 38 | All as per serial item No 37 but SPN 63 Amps. Make -L&T or equivalent of Crompton/havells/indoasian. | 48 | 5 | Each |
49 | 39 | Supply and fixing MCB, triple pole and neutral, 63 Amps, 415 volts complete all as specified and directed by Engineer-in-Charge. Make -L&T or equivalent of Crompton/ havells/indoasian. | 49 | 10 | Each |
50 | 40 | All as per serial item No 39 but TP 63 Amps. Make -L&T or equivalent of Crompton/havells/indoasian. | 50 | 15 | Each |
51 | 41 | Supply and fix sheet metal enclosure industrial type complete with plug and socket 5 pin ( 3 phase+1 N+1E) including three pole MCB 32 Amps breaking capacity 6 kA complete all as specified and directed by Engr-in charge. | 51 | 1 | Each |
52 | 42 | Supply and fixing of switch fuse unit in sheet metal enclosure TPN 32 Amps, 415 V, AC 50 Hz, rotary type handle with fuse complete all as specified. Make : L&T or equivalent of Havells/crompton/Indoasian | 52 | 2 | Each |
53 | 43 | -ditto- all as per above item No 42 but TPN 63 Amps. | 53 | 1 | Each |
54 | 44 | Supply and fixing vertical type TPN load line sheet metal Distribution board double door for housing MCCB and MCB triple pole, 4 way complete with bus bar and including with incomer MCCB 100 amps 3 Pole , breaking capacity 16 kA- 01 Nos all as specifed and as directed by Engineer-in-Charge. Make : L&T or equivalent of Havells/Crompton/Indoasian Note - MCB's will be measured and paid as separate item. | 54 | 1 | Each |
55 | 45 | All as per above item No-44 but TP 8 way. | 55 | 1 | Each |
56 | 46 | Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre deep below ground level with top edge of the plate not less than 1.5 metre below normal ground level and connected to earth plate surrounded by 15cm thick packed layers of charcoal dust and common salt and conected to GI wire 4mm dia by means of bolts, nuts check nuts and wahsers of galvaised iron or steel and thimbles and otehr end of the earth wire connected to DB and protected by galvaised iron or steel pipe light grade 15mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and Rcc cover all as shown in Electrical Plate No 3. | 56 | 30 | Each Set |
57 | 47 | All as per above item No-46 but using 25x4mm as earthing lead. | 57 | 2 | Each Set |
58 | 48 | Supply and fix in replacement of energy saving, enviromental friendly highbay fitting with highpower COM LED as light source of 120 W all as directed by Engr- in -charge. Make: Bajaj cat Part No : BGPPH 120 W LED or equivalent of Crompton/philips/Wipro. | 58 | 12 | Each |
59 | 49 | Supply only LED PL 4 pin 15 Watt tube complete. Make - Bajaj Cat part No- BLL15W LED 2G11 or equivalent of Crompton/philips/Wipro. | 59 | 100 | Each |
60 | 50 | Supply only Switch socket combination 5 amp 5 pin. | 60 | 200 | Each |
61 | 51 | Supply only Switch socket combination 15 amp 5 pin universal. | 61 | 200 | Each |
62 | 52 | Supply only Flexible copper wire 23/0.0076 PVC sheathed. | 62 | 300 | RM |
63 | 53 | Supply only PVC Box of size 7" x 8" | 63 | 15 | Each |
64 | 54 | Supply only PVC Box of size 4.5" x 3" suitable for 15 amp switch-socket | 64 | 15 | Each |
65 | 55 | Supply only LED tube rod 18 watt, 4 feet cool white Make - Bajaj, Cat Part No--BLRB-18W CW LED or equivalent of Crompton/philips/Wipro. | 65 | 500 | Each |
66 | 56 | Supply only LED batten with tube 10 watt fitting. Make-Bajaj, Cat Part No- BCLSB-10WH or equivalent of crompton/philips/Wipro. | 66 | 60 | Each |
67 | 57 | Supply only PVC aluminium service cable twin core 6 Sqmm weather proof. | 67 | 600 | RM |
68 | 58 | Supply only step type electronic fan regulator flush type suitable for 1200/1400mm sweep fan. | 68 | 200 | Each |
69 | 59 | Supply only insulation tape size 2.5cm x 25 mtr x .125mm | 69 | 80 | Each Roll |
70 | 60 | Supply only switch piano type 5/6 Amp one way. | 70 | 300 | Each |
71 | 61 | Supply only pulg top 6 Amps | 71 | 20 | Each |
72 | 62 | Supply only pulg top 16 Amps with indicator. | 72 | 40 | Each |
73 | 63 | Supply only Power unit combo 20 Amps MCB protected socket with PVC junction box. | 73 | 20 | Each |
74 | 64 | Supply only 6/16 Amps switch socket combination with PVC junction box. | 74 | 10 | Each |
75 | 65 | Supply only cable PVC FRLS insulated unsheathed stranded copper conductor 1.5 Sqmm | 75 | 450 | RM |
76 | 66 | Supply only cable PVC FRLS insulated unsheathed stranded copper conductor 2.5 Sqmm | 76 | 360 | RM |
77 | 67 | Supply only cable PVC FRLS insulated unsheathed stranded copper conductor 4 Sqmm | 77 | 180 | RM |
78 | 68 | Supply only cable PVC FRLS insulated unsheathed stranded copper conductor 6 Sqmm | 78 | 90 | RM |
79 | 69 | Supply only PVC sheathed copper cable 2.5 Sqmm 3 Core. | 79 | 300 | RM |
80 | 70 | Supply only MCB SP 6-32 Amps | 80 | 75 | Each |
81 | 71 | Supply only MCB SPN 40 Amps | 81 | 40 | Each |
82 | 72 | Supply only MCB TPN 63 Amps | 82 | 30 | Each |
83 | 73 | Supply only MCB TP 63 Amps | 83 | 30 | Each |
84 | 74 | Supply only fan condensor 2.5 mfd. Make : EPCOS/Asian | 84 | 150 | Each |
85 | 75 | Supply only casing capping size 20 mm ISI marked medium grade. | 85 | 70 | RM |
86 | 76 | Taking down the defective ceiling fan of 1200/1400 mm sweep any make any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running including servicing/overhauling the ceiling fan by throughly cleaning the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly. (Note : Spare parts will be measured & paid as separate items) | 86 | 150 | Each |
87 | 77 | Re-winding the ceiling fan 1200/1400 mm sweep with same guage supper enamelled copper wire complete all as specified and as directed. | 87 | 80 | Each |
88 | 78 | Taking down the defective Exhaust fan 300 mm sweep any make and any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running including servicing/overhauling the exhaust fan by throughly cleaning the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly. (Note : Spare parts will be measured & paid as separate items) | 88 | 65 | Each |
89 | 79 | Re-winding the exhaust fan with same guage supper enamelled copper wire complete all as specified and as directed. | 89 | 25 | Each |
90 | 80 | Taking down the defective Exhaust fan 450 mm sweep any make any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running including servicing/overhauling the exhaust fan by throughly cleaning the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly. (Note : Spare parts will be measured & paid as separate items) | 90 | 40 | Each |
91 | 81 | Re-winding the exhaust fan with same guage supper enamelled copper wire complete all as specified and as directed. | 91 | 20 | Each |
92 | 82 | Taking down the defective Wall mounted fan 450 mm sweep any make any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running including servicing/overhauling the Wall mounted fan by throughly cleaning the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly. (Note : Spare parts will be measured & paid as separate items) | 92 | 15 | Each |
93 | 83 | Re-winding the wall fan with same guage supper enamelled copper wire complete all as specified and as directed. | 93 | 10 | Each |
94 | 84 | Taking down the defective Air circulator fan 600 mm sweep any make any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running includingservicing/overhauling the Air circulator fan by throughly cleaning the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly. (Note : Spare parts will be measured & paid as separate items) | 94 | 35 | Each |
95 | 85 | Re-winding the air circulator fan with same guage supper enamelled copper wire complete all as specified and as directed. | 95 | 15 | Each |
96 | 86 | Supplying only of ball bearing suitable for exhaust fan,up to 450 mm size complete all as specified and as directed.MAKE : NBC, SKF or equivalent make as approved by GE. | 96 | 50 | Each |
97 | 87 | Supplying only of ball bearing suitable for ceiling fan complete all as specified and as directed. MAKE : NBC, SKF or equivalent make as approved by GE. | 97 | 80 | Each |
98 | 88 | Supplying only of gun metal bush suitable for ceiling fan, any sweep complete all as specified and as directed. | 98 | 20 | Each |
99 | 89 | Supply & fix of fan hanging mild steel ‘U’ clamps of suitable size duly painted for hanging of ceiling fan with nuts, bolts, split pins and rubber real complete all as specified and as directed. | 99 | 10 | Each |
100 | 90 | Supply and fix in repairs fan condensor 2.5 mfd. Make : EPCOS/Asian | 100 | 100 | Each |
101 | 91 | Inspection and maintenance of water heater (Geysers) of capacity, 25 ltrs to 50 litres including performing the following task at different locations at VRDE.\n(a) Removing the heather plate assembly and descaling the heating element/pipe either by use of acid or equa cleaner to make it functional complete.\n(b) Checking and setting of thermostat between 70 to 80 degree Celsius.\n(c) Check working of NRV stop cock, pressure release valve and servicing carefully to make it functional.\n(d) Repairing of earthing connection, power switch, socket connection replacement of indicator lamp to make it functional.\n(e) Examine water leakage and rectifying as required and replacement of rubber washer gasket etc to make it functional.\n(f) Inspect over flow vent pipe, safety valve and remove blockage if required to make it functional. | 101 | 10 | Each |
102 | 92 | Supply & fix of heating element of rating 2 KW to geyser 25 to 50 litres capacity, any type, complete all as specified and as directed. | 102 | 5 | Each |
103 | 93 | Supply & fix of heating element of rating 1.5 KW to geyser 25 to 50 litres capacity, any type, complete all as specified and as directed. | 103 | 5 | EACH |
104 | 94 | Supply & fix of the thermostat (adjustable type) suitable for upto 50 litres capacity of geysers. | 104 | 10 | Each |
105 | 95 | Supplying and fixing in replacement of geyser plate assembly suitable for 25 to 50 litres capacity geysers, of brass with inlet, outlet pipe, drain plug, thermostat chamber fixing heating element gasket nut, bolt etc are fixing the assembly to make it functional complete all as specified and as directed. | 105 | 2 | Each |
106 | 96 | Supply & fixof flexible PVC pipe connection, heavy duty nylon thread reinforced 15 mm dia, 450 mm long with brass union at both ends for 15 mm dia pipe complete all as specified and as directed. | 106 | 12 | Each |
107 | 97 | Supply & Fix gasket of thickness 5 mm for geyser assembly of 08 holes/09 holes complete all as specified & directed.. | 107 | 5 | Each |
108 | 98 | Supply & Fix metal clad top & socket 15 Amp cap complete all as directed. | 108 | 5 | Each |
109 | 99 | S&F non return valve for geyser all as directed. | 109 | 3 | Each |
110 | 100 | Supply & fix fastner mild steel 100/150/200 mm long complete all as specified & directed. | 110 | 16 | Each |
111 | 101 | Dismantling/taking out the geyser assembly & copper tank and making soldering & brazing of tank and fixing the same in the geyser of any cap. | 111 | 8 | Each Job |
112 | 102 | Taking down /out from existing position window type AC's of capacity 1.5/2TR, servicing the same by cleaning, dusting with blower, checking wiring, nuts, bolts, electrical contacts, tightening all loosened parts as required,setting grills and fan blades for proper functioning, oiling, greasing to moving parts including replacing defective parts and sleaves etc and refixing the same to its original position and testing for smooth functioning complete all as specified and as directed. | 112 | 50 | Each Job |
113 | 103 | Taking down /out from existing position split type AC's indoor & outdoor units of capacity 1.5/2TR, servicing the same by cleaning, dusting with blower, checking wiring, nuts, bolts, electrical contacts, tightening all loosened parts as required,setting grills and fan blades for proper functioning, oiling, greasing to moving parts including replacing defective parts and sleaves etc and refixing the same to its original position and testing for smooth functioning complete all as specified and as directed. | 113 | 45 | Each Job |
114 | 104 | All as per item No 103 above but refigerator & deep freezer capacity 165 ltrs to 350 ltrs complete all as specified and directed by Engr- in- Charge. | 114 | 3 | Each Job |
115 | 105 | All as per item No 103 above but water cooler capacity 40 ltrs to 150 ltrs complete all as specified and directed by Engr- in- Charge. | 115 | 10 | Each Job |
116 | 106 | All as per item No 103 above but desert cooler capacity of any capacity upto 5000 cum including washing with water complete all as specified and directed by Engr- in- Charge. | 116 | 45 | Each Job |
117 | 107 | Disconnecting burnt out compressor from existing electric and pipe line connections of refrigerator of capacity 300/350 ltr of any make and replacing the same with factory made reconditioned compressor including connecting suction and discharge line by cooler brazing. | 117 | 1 | Each Job |
118 | 108 | All as per item No 107 above but water cooler of capacity 40/80 ltrs complete all as specified and as directed. | 118 | 1 | Each Job |
119 | 109 | All as per item No 107 above but water cooler of capacity 60/120/150 ltrs complete all as specified and as directed. | 119 | 1 | Each Job |
120 | 110 | All as per item No 107 above but Window / Split type AC of capacity 1.5 TR complete all as specified and as directed. | 120 | 2 | Each Job |
121 | 111 | All as per item No 107 above but Window / Split type AC of capacity 2 TR complete all as specified and as directed. | 121 | 2 | Each Job |
122 | 112 | S&F in replacement condensor fan motor for water coolers any capacity.suitable for water cooler of capacity 40/80, 60/120 & 60/150 liters | 122 | 1 | Each Job |
123 | 113 | S&F in replacement blower fan motor for window AC of capacity 1.5 TR complete all as specified and as directed. | 123 | 1 | Each Job |
124 | 114 | S&F in replacement blower fan motor for window AC of capacity 2 TR complete all as specified and as directed. | 124 | 1 | Each Job |
125 | 115 | S&F in replacement blower fan motor for split type AC in door unit of capacity 1.5 TR complete all as specified and as directed. | 125 | 1 | Each Job |
126 | 116 | S&F in replacement blower fan motor for split type AC in door unit of capacity 2 TR complete all as specified and as directed. | 126 | 1 | Each Job |
127 | 117 | S&F in replacement condensor motor for split type AC out door unit of capacity 1.5 TR complete all as specified and as directed. | 127 | 1 | Each Job |
128 | 118 | S&F in replacement condensor motor for split type AC out door unit of capacity 2 TR complete all as specified and as directed. | 128 | 1 | Each Job |
129 | 119 | S&F in replacement fan motor of 230 volt, 50 Hz, SP suitable for desert cooler of capacity 3000/5000 cum per hour complete all as specified and as directed. | 129 | 2 | Each Job |
130 | 120 | Supply and charging only refrigerent gas of required HD ie Hydrocarbon, 134, R-22 or R-12 or any latest version for refrigerators of capacity 310 lts including cutting copper pipe and sealing by brazing etc after charging gas as required and leak testing complete all asspecified and as directed. | 130 | 1 | Each Job |
131 | 121 | All as per item No 120 above but for water coolers of capacity 40/80, 60/120, 150/150 ltr capacity complete all as specified and as directed. | 131 | 5 | Each Job |
132 | 122 | All as per item No 120 above but for window/split type AC of capacity 1.5 TR complete all as specified and as directed. | 132 | 30 | Each Job |
133 | 123 | All as per item No 120 above but for window/split type AC of capacity 2 TR complete all as specified and as directed. | 133 | 30 | Each Job |
134 | 124 | Supply only in replacement running/starter capacitor 2.5/3.15/4.0/6.0 mfd, 230 volt, AC for cooling appaliances complete all as specified and as directed. | 134 | 18 | Each |
135 | 125 | All as per item No 124 above but of 10.0/15.0 mfd complete all as aspecified and as directed. | 135 | 8 | Each |
136 | 126 | All as per item No 124 above but of 36.0/45.0 mfd complete all as aspecified and as directed. | 136 | 16 | Each |
137 | 127 | All as per item No 124 above but of 40.0/60.0 mfd complete all as aspecified and as directed. | 137 | 4 | Each |
138 | 128 | Supply only in replacement thermostate suitable for window/split type AC's water coolers, Refrigerators and Deep freezers of any make, capacity and model and testing complete all as specified and as directed. | 138 | 15 | Each |
139 | 129 | Supply and fix in replacement over load protector suitable for window/split type AC's, water coolers, Refrigerators and Deep freezers of any make, capacity and model and testing complete all as specified and as directed. | 139 | 4 | Each |
140 | 130 | Supply and fixing in replacement box type relay or package assembly from suitable window type AC's of capacity 1.5/2 TR complete all as specified and as directed. | 140 | 4 | Each |
141 | 131 | All as per item No 130 above but for split type AC's of capacity 1.5/2 TR complete all as aspecified and as directed. | 141 | 4 | Each |
142 | 132 | All as per item No 130 above but for water coolers capacity 40/80, 60/120 & 60/150 ltrs complete all as aspecified and as directed. | 142 | 2 | Each |
143 | 133 | S&F in replacement 15mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed in water coolers complete all as aspecified and as directed. | 143 | 4 | Each |
144 | 134 | S&F in replacement push cock, 15mm dia, chromium plated self closing type complete all as aspecified and as directed. | 144 | 4 | Each |
145 | 135 | S&F in replacement 15mm dia stop valve, cromium plated screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as aspecified and as directed. | 145 | 5 | Each |
146 | 136 | S&F in replacement PVC connection 600 mm long with brass ends terminals suitable for water coolers complete all as aspecified and as directed. | 146 | 10 | Each |
147 | 137 | S&F in replacement PVC pipe 32mm dia for draining out waste water complete all as aspecified and as directed. | 147 | 35 | RM |
148 | 138 | S&F in replacement fan blade set for water coolers fan motor complete all as aspecified and as directed. | 148 | 2 | Each |
149 | 139 | Supply and fixing in replacement Plug top 3 pin, 230 volt 6 Amps. | 149 | 10 | Each |
150 | 140 | Supply and fixing in replacement Plug top 3 pin, 230 volt 16 Amps. | 150 | 20 | Each |
151 | 141 | Supply and fixing in replacement Air filter PVC type of existing window / split type AC's of capacity 1.5/2 TR complete. | 151 | 5 | Each |
152 | 142 | S&F in replacement PVC insulated cable 3 core 2.5 Sqmm, 1100 volts grade copper conductor, multistranded including testing complete all as specified and as directed. | 152 | 90 | RM |
153 | 143 | All as per item No 142 above but 3 core 1.5 Sqmm. | 153 | 90 | RM |
154 | 144 | S&F in replacement Heatlion insulation pipe for wrapping copper tape duly fixed with polythelene type to suction and discharge lines for existing window/split type AC's 1.5/2 TR from any position or any make including testing complete all as specified and as directed. | 154 | 25 | RM |
155 | 145 | S&F in replacement Electronic card of existing window/split type AC's of capacity 1.5 / 2 TR including testing complete all as specified and as directed. | 155 | 2 | Each |
156 | 146 | Supply only of wood wool pads of best quality as approved with and including wire mesh jalli for desert cooler of any size make and capacity all as specified and as directed. | 156 | 30 | Each set of three |
157 | 147 | S&F in replacement water pump, 230 volt, 50 Hz, SP with discharge head 1.87 mtr for desert cooler of any capacity complete all as specified and as directed. | 157 | 15 | Each |
158 | 148 | M&L for vacuuming complete system of central/ package type air conditioning plant with double stage vacuum pump of (-) 2Kg/cm² vacuum pressure after repairs to compressor or repair in refrigeration system, charging the dry nitrogen gas, R-22 and hold up to 24 hrs and rectifing the leackage if any by repairing the "O" ring and gland packing of service valve/ Oil seal including top up the compressor oil and charging the refrigerant gas (R-22) at various plant all as specified and directed by Eng-in-charge.\na) Central type AC Plant at Emission Lab (3x11 TR) | 158 | 1 | Job |
159 | 148.01 | b) Central type AC Plant at Emission Lab (2x11 TR) | 159 | 1 | Job |
160 | 148.02 | c) Package type AC Plant (4x8.5 TR) | 160 | 1 | Job |
161 | 149 | Supply only of R-22 refrigerent gas to central AC system and package AC plant, testing for leakage in system and commissioning all as specified and directed by Engr-in-charge. | 161 | 45 | Kg |
162 | 150 | Supply only nitrogen gas for leak testing of central AC / package AC plant system. | 162 | 20 | Kg |
163 | 151 | Supply only of compressure oil N-68 after flushing compressure and testing commissioning all as directed by Engr-in-charge. | 163 | 20 | Ltr |
164 | 152 | S&F in replacement drier filter DL-100 for liquid line of package type AC plant all as specified and directed by Engr-in-Charge. | 164 | 2 | Each |
165 | 153 | S&F in replacement of scroll type hermetically sealed compressor 4.25 TR capacity 3 phase, 50 Hz, 380/420V with R22 for package AC plant. | 165 | 1 | Each |
166 | 154 | To attend any break down & checking the electrical connections & wiring of equipment and rectify the problem of summer appliances ie. Split type AC's, window type AC's, water coolers, refrigerator of any capacity or make/model, installed at VRDE complex as and when required during working/non working hours all as directed by Engr-in-charge. Note :- (i) Spares will be measured and paid separately under relevent items. (ii) complaint if not attended with in 24 hrs after receiving complaint, panelty will be recovered at double by the contractor. | 166 | 65 | Each |
167 | 155 | Taking down/out the blower/condensor fan motor of any make and capacity, transporting to workshop, opening up, cleaning, taking out burnt winding etc, and rewinding of motor with superior quality of enamelled copper wire of same guage, reassembling and fixing back at the same position including testing and making necessary connection complete all as specified and as directed. \n(a) Blower fan motor (Two speed i.e. low and high for window type AC of capacity 1/5 HP capacity) | 167 | 1 | Each |
168 | 155.01 | (b) Condensor fan motor for water cooler1/6 HP Capacity. | 168 | 1 | Each |
169 | 155.02 | (c) Air cooler fan motor having three speed, single phase 230 volts, 50 Hz of 380 to 450mm sweep. | 169 | 1 | Each |
170 | 155.03 | (d) Condensor fan motor for split type AC of capacity 1.5 TR. | 170 | 1 | Each |
171 | 155.04 | (e) Blower fan motor for split type AC of capacity 1.5 TR. | 171 | 1 | Each |
172 | 155.05 | (f) Condensor fan motor for split type AC of capacity 2 TR. | 172 | 1 | Each |
173 | 155.06 | (g) Blower fan motor for split type AC of capacity 2 TR. | 173 | 1 | Each |
174 | 156 | Taking down/out window / split type AC 1.5/2 TR capacity of any make, from existing position, transporting and refixing at new location including making necessary connections to make it functional complete all as specified and directed.\nNote : Gas charging and/or parts if required shall be measured and paid separetely. | 174 | 12 | Each Job |
175 | 157 | Detecting gas leakage of water cooler, refrigerators, deep freezers, window type AC's and split type AC's and rectifying / arresting the leakages, testing for pressure drop complete all as specified and as directed.\nNote : Gas charging shall be measured and paid separetely. | 175 | 45 | Each |
176 | 158 | S&F in replacement PCB unit for remote control including remote for AC unit complete all as specified and directed. | 176 | 1 | Each |
177 | 159 | S&F in repair selector switch 3 way for AC 1.5/2 ton all as directed. | 177 | 4 | Each |
178 | 160 | Dismantling the voltage stabilizer 230/250 Volts 1 KVA and reassembling the same after servicing & tightening the electrical connection & replacing the u/s parts as required and make it functional complete all as specified & directed. | 178 | 2 | Each Job |
179 | 161 | All as per item No.160 above but 2.0 KVA cap. | 179 | 2 | Each Job |
180 | 162 | All as per item No. 160 above but 3.0 KVA cap. | 180 | 2 | Each Job |
181 | 163 | All as per item No.160 above but 5.0 KVA cap. | 181 | 2 | Each Job |