Outsourcing The Resources For Operation And Management Of 15 Af Hospital Sub Station At Air Force Station Jaisalmer, GE (AF) Jaisalmer-Rajasthan

Military Engineer Services-MES has published Outsourcing The Resources For Operation And Management Of 15 Af Hospital Sub Station At Air Force Station Jaisalmer. Submission Date for this Tender is 15-06-2020. Substation Tenders in GE (AF) Jaisalmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

24429622
Outsourcing The Resources For Operation And Management Of 15 Af Hospital Sub Station At Air Force Station Jaisalmer
National Competitive Bid
Indian
Rajasthan
GE (AF) Jaisalmer
15-06-2020

Tender Details

Outsourcing The Resources For Operation And Management Of 15 Af Hospital Sub Station At Air Force Station Jaisalmer

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work : OUTSOURCING THE RESOURCES FOR OPERATION AND MANAGEMENT OF 15 AF HOSPITAL SUB STATION AT AIR FORCE STATION JAISALMER
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Schedule 'A' Part-I\nGeneral Note as applicable for serial item No 2.00 of BoQ/Sch 'A' Contractors attention is hereby invited that estimated cost of serial item No 2.00 is Rs. 8,24,100.00 based on prevailing rates of Schedule of Minimum fair wages. Quoted amount against serial item No. 2.00 is less than the amount the work (Estimated of serial item No. 2.00 of BoQ/Sch 'A') then lowest bidder will have to deposit FDR in favour of Accepting Officer within 07 days from financial bid opened difference in Estimated cost & quoted amount of serial item No. 2.00 before evaluation of financial bid for acceptance of tender, failing which lowest tender will not be accepted. FDR submitted at the time of Acceptance of bidder will be realesed only after satisfactory proof of payment of deployed person under the respective serial item No. 2.00 of BoQ.
2 2 Manning and Operation of 11 KV Sub Station, 15 AF Hospital (One Skilled Electrician) in three shift of 8 hours each for 24 hours continuous operation every day (including Sunday/Holiday) to maintain sub station in/out side HT/LT Panels/LT Complaints as specified, including daily and weekly check-up, monthly, quarterly and half yearly maintenance as per maintenance schedule as specified under particular specification with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge.\nNote for item No. 2.00\n(a) The contractor shall take over all equipment in serviceable condition at the time of commencement of contract and shall hand over in the same state at the time of completion of contract period. Any damage/loss shall be made good by the contractor at the time of completion of contract. GE's decision will be final and binding. 1005 Per Shift
3 2.01 Note for item No. 2.00 (Contd....)\n(b) Daily cleaning of all Panels, transformers, recording meter readings. \n(c) Daily cleaning of all rooms viz floor, walls and ceiling fan including internal electrical fixtures. \n(d) No unauthorized person shall be allowed to enter in sub division.\n(e) 11 KV Sub Station will be operated 24 hours round the clock including Sunday/Hilidays. \n(f) All T&P insulating cloths, for operatorss, log-books, instruction board duly laminated for 'DO or "NOT DO" Fire safety instruction board etc. shall be provided by the contractor. \n(g) During maintenance & operation of 11 KV Sub station, any parts found defective and require to be replaced same will be measured under Schedule 'A' Part-II. The fixing changes shall be deemed included in rates quoted under Sch 'A' Part.\n(h) Contractor shall be responsible for group insurance for eleven month of manpower deployed by him against the contract.\n(J) Contractor shall provided proper uniform of the operatior as deployed by him and dress code shall be approved by GE/AGE concerned.\n(k) Daily attendance register shll be maintained by both contractor and concerened JE and register weekly put up to concerned AGE for the record purpose.\n(l) Labour deployed by the contractor shall be responsible for complete area cleaing of 11 KV installation inside / outside all as specified and directed by Engr-in-Charge.\n(m) Fuel for operation of DG Sets shall be supplied by the Department as free for filling only. However storage facilities of fuel and collection of fuel from MES Store shall be provided by the contractor.
4 3 Schedule 'A' Part-II\nSupply & fixing Lead Acid Battery, 12 Volt, 26 AH capacity, 25 plates with one year warranty, including initial charging and connecting DC cable, thimbles, nut, bolts etc including disconnecting & taking out old unserviceable battery complete all as specified and directed. Make : Exide/Amco/Amron / Sukam / Okaya 30 Each
5 4 S&F in replacement of unserviceable under voltage (UV) coil, shunt coil and tripping coil of capacity 1600 Amp, 415 volt with rupturing capacity of 50 kA and complete with making all connection all as specified and directed by Engr-in-Charge. 2 Each Job
6 5 S&F MCCB, 4 Pole, 200 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed. Make : Legrand Cat Part No. 4202 18 or Havells/C&S/L&T/ABB/C&S 2 Each
7 6 S&F MCCB, 4 Pole, 160 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed. Make : Legrand Cat Part No. 4200 57 or Havells/C&S/L&T/ABB/C&S 2 Each
8 7 S&F MCCB, 4 Pole, 100 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed. Make : Legrand Cat Part No. 4200 55 or Havells/C&S/L&T/ABB/C&S 3 Each
9 8 S&F MCCB, 4 Pole, 63 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed. Make : Legrand Cat Part No. 4200 53 or Havells/C&S/L&T/ABB/C&S 4 Each
10 9 M&L for disconnection of existing Air circuit breaker and replacement of complete internal mechanism of existing Air circuit breaker in existing panel of capacity 1600 Amp, 415 volt grade with rupturing capacity 50 KA and complete with making all connection complete all as specified and directed by Eby Engr-in-Charge. 1 Each Job
11 10 M&L for making earthing pit on existing old earthing where pit is completely damaged including cover 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/sqm in lieu of CI cover, PCC 1:3:6 type C2 pit/chamber including all necessary excavation and earth work complete all as directed. 5 Each Job
12 11 S&F in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 6mm copper strip complete all as specified.\nNote : Nut, bolt and other items included in quoted rate by the tenderer.) 40 RM
13 12 M&L in repair for Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 32mmx6mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No 5 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 50mm bore GI pipe light grade for earth wire protection fixed with poles with two clamps, made from earth lead strip 32mm x 6mm, bolts, nuts and washers, 80mm thick pre cast RCC cover 1:2:4, type B-1, reinforced with hard drawn steel wire fabric wieghing not less than 4 Kg/Sqm in lieu of CI cover etc complete all as specified. \nNote : (i) The unit rate shall be deemed to included for Test point, 32mmx6mm GI strip from top of the earth plate upto 7.50m above ground level. In case, GI protection pipe required is less than 7.50m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate quoted by the tenderer. 4 Each Set
14 13 Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed. 75 RM
15 14 Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 25 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed. 75 RM
16 15 Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed. 80 RM
17 16 Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and getting out hard/dense soil complete all as specified and directed. 32 Cum
18 17 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified 22 Cum
19 18 Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified. 8 Cum
20 19 M&L for stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed. 54 Sqm
21 20 M&L for dry sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed.\nNotes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.\n 15 Cum
22 21 Supply, fixing, commissioning and testing of automatic operation of street light switch having lighting control through astronomical calculation of sun rise/sun set time by setting data, time and degree of longitude, latitude without of separate light sensor, enclose in sheet metal enclosed metal out of 14 SWG CRCA sheet duly painted and prewired of suitable size duly fixing of angle iron of suitable size including PCC work if required all as specified comprising of the following:-\n(a) Timer switchmulti functional Astro D21 Make : Legrand Cat Part No 4126 544 - 02 Nos\n(b) Power contractor 4 Pole 63 Amps Make : Legrand Cat Part No 4125 57 - 01 Nos\n(c) Auxillary Changeover switch 6 Amp, 250 Volt AC, Make : Legrand Cat Part No 4062 50 - 01 Nos\n(d) MCB SP 6 Amp 10 kA, 240 volts, Make : Legrand Cat Part No 4085 87 - 01 Nos\n(e) MCB 4 Pole 63 Amps, 415 volt, 10 KA, Legrand Cat Part No 4087 02 - 01 Nos\n(f) Flexy DB 03 row of 14 module IP-43 IK-9 with metal door Legrand Cat Part No 5077 12 - 01 Nos 1 Each Job
23 22 S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire two single core cables 10 Sqmm including taking down old unserviceable cable complete all as specified. 180 RM
24 23 S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire two single core cables 6 Sqmm including taking down old unserviceable cable complete all as specified 180 RM
25 24 S&F in replacement of digital type volt meter 0-500 volts, 3 Phase, 50 Hz complete all as specified and as directed. 2 Each
26 25 S&F in replacement of digital type ammeter 0-200 volts, 3 Phase, 50 Hz complete all as specified and as directed. 2 Each
27 26 S&F in replacement of selector switch for voltmeter/ammeter 3 phase 50 Hz complete all as specified and as directed. 3 Each
28 27 S&F in replacement of indicator lamps RYB colours complete all as specified and as directed. 6 Each
29 28 S&F in replacement of CT coils of ratio of 600/05 complete all as specified and as directed. 2 Each
30 29 Supply and fixing in replacement of socket outlet, 2 in 1, 3 pin, 5/6 Amp, flush type, (ISI Marked), 240 Volts. 50 Each
31 30 S&F in replacement socket outlet 2 in 1, 3 pin, 15 Amps flush type, (ISI Marked), 240 Volts. 25 Each
32 31 S&F in replacement of switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts (ISI Marked). 50 Each
33 32 S&F in replacement of switch piano, flush type, single pole, one way, 15 Amp, 230 Volts (ISI Marked). 25 Each
34 33 Supply and fixing stepped type electronic fan regulator, flush type and connecting up, ISI marked, 240 Volts including taking down unserviceable complete all as specified. 25 Each
35 34 S&F in replacement of lamp holder angular type, PVC/Polycarbonate type with cord grip cap suitable for batten fiitting complete all as specified. 50 Each
36 35 S&F in replacement surface and wall mounted LED tube light fittings of capacity 20 watt, Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver all as specified and directed by EIC. Make : Syska Cat No. Cat Part No- SSK-ALB-20W or equivallent in Havells/CG Philips/GE 75 Each
37 36 S&F in replacement surface and wall mounted LED tube light fittings of capacity 9 watt, basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver complete all as specified and directed by Engineer-in-Charge. Make : Havells Cat Part No. LHEXBQP7IN1W009 or equivallent in Philips/CG 25 Each
38 37 S&F in replacement of ultra modern designed architectural, LED Recessed full open 2X2 Tile, Glare free uniform illumination with longer life and less maintenance, luminaire of capacity 36 watt which provides soft-light and suitable for armstrong/grid ceiling complete all as specified and directed. Make : Crompton Greaves Cat Part No. LCTLRN-36-FO-CDL or equivallent in Philips/GE/Havells. 50 Each
39 38 S&F in repair and connecting LED flood light fittings on high mast pole pressue die cast housing with IP 66 protection high resistant tempered glass for protection with 5 KV surge protection applicable for large area lighting with efficient high output emitter LED for better distributioin of capacity 170 Watt (6000K CCT) complete all as specified. Make : Cat Part No LSFO-170-CDL/60 of crompton Greaves or equivallent in Orient/Wipro. 4 Each
40 39 S&F in replacement 9 watt LED bulb. Make : Havells Cat Part No. LHLDEUEEMC8R009 or equivalent. 20 Each
41 40 S&F in replacement 15 watt LED bulb. Make : Havells Cat Part No. LHLDDEEEML8R015 or equivalent. 20 Each
42 41 S&F in replacemet MCB SPN 10 Amp to 40 Amps Make:- Legrand/Havells/Schneider 30 Each
43 42 S&F in replacement MCB SP 240 Volts 10 amp to 40 Amps Make:- Legrand/Havells/C&S 30 Each
44 43 Repair to voltage stabilizer automatic oil cooled, 3 phase, 4 wire, AC supply servo controlled, 440 Volt, 1000 KVA unbalanced type by disconnecting incoming and outgoing connections, reconnecting with suitable cable lugs after carrying out repairs of the following :-\n(a) Gear Assembly - 01 Nos.\n(b) Replacement of servomotor (03 Nos) as per existing of min 10 KG/CM torque.\n(c) Replacement of carbon roller assembly - 01 Nos.\n(d) Replacement of PCB - 01 Nos.\n(e) Repair to circuit complete alongwith where ever required wiring.\n(f) High low voltage cut off - 01 Nos.\n(g) Toggle switch - 01 Nos.\n(h) Control transformer - 01 Nos.\n(i) Replacement of indicating lamps complete - 01 Nos.\n(j) Replacement of voltmeter with selector switch - 01 Nos\n(k) Replacement of worn out wiring with copper cable including soldering of joints and providing sleaves.\n(l) Preston type switch - 01 Nos.\n(m) Replacement of complete Dimmer state-02 Nos complete with carbon bush and holder.\n(Rates quoted by the contactor shall be deemed to include for transportation if reqd. Testing commissioning of the stabilizer on full load to the entire satisfication of Engr-in-Charge).\n 1 Each Job
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail