Sitc Of 2X 5 Mva , 33/11 Kv Indoor Sub-Station At City Park ( Oxyzone ) Electric Work, Kota-Rajasthan

Urban Improvement Trust-UIT has published Sitc Of 2X 5 Mva , 33/11 Kv Indoor Sub-Station At City Park ( Oxyzone ) Electric Work. Submission Date for this Tender is 15-06-2020. Electrification Work Tenders in Kota Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

24416856
Sitc Of 2X 5 Mva , 33/11 Kv Indoor Sub-Station At City Park ( Oxyzone ) Electric Work
Open Tender
Indian
Rajasthan
Kota
15-06-2020

Tender Details

Sitc Of 2X 5 Mva , 33/11 Kv Indoor Sub-Station At City Park ( Oxyzone ) Electric Work

Key Value

Document Fees
INR 7500 /-
EMD
INR 758000.0 /-
Tender Value
INR 3.79 Crore /-

BOQ Items

Name of Work: SITC of 2x 5 MVA, 33/11 KV Indoor Sub-Station at City Park (Oxyzone)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply and fixing of 33KV, 630Amp. 3 Pole central pot rotating double break type isolator (IS: 9921 part I to V) without earth blade operating mechanism spring loaded reverse loop type fixed contact, solid hard drawn electoytic copper tubular moving contact with silver/nickel plated at end points, 9 nos. post insulator of 2x24KV (IS: 2554 & IS: 5350 part III), hot dipped galvanizing hard ware, nut bolts, etc. complete in all respect as per latest specifications of Discoms 2 Nos
2 2 SITC of 33/11 KV, 5 MVA star delta transformer with off Circuit Tap changer on existing platform with one bucholdz Relay, Megnatic type oil level guage , winding temperature Indicator , oil temperature indicator and provided with ONAN type Cooling complete in all respect as per latest specifications of Discoms including making necessary connection etc. ( The Transformer should be CTL tested by Discom). 2 Nos
3 3 SITC of 12KV(630amp & making capacity 16-31.5ka) Indoor Type VCB Switch Gear & Control Gear Panel, is directly installed at site on a Trench/Floor .CTs,PTs and Scada enabled relay control panel is in-built in the metal enclosure. The power supply can be taken through Sufficient space for receiving the cables inside the switch board at the bottom of the cubicles and mounting arrangement for the terminal cable glands shallbe provided. Includes all Accessories complete in all respect as per latest specifications of Discoms . 12 KV I/D VCB SWITCH GEAR & CONTROL GEAR PANEL (I/C TYPE) 2 Nos
4 4 SITC of 12KV(630amp & making capacity 16-31.5ka) Indoor Type VCB Switch Gear & Control Gear Panel, is directly installed at site on a Trench/Floor .CTs,PTs and Scada enabled relay control panel is in-built in the metal enclosure. The power supply can be taken through Sufficient space for receiving the cables inside the switch board at the bottom of the cubicles and mounting arrangement for the terminal cable glands shall be provided. Includes all Accessories complete in all respect as per latest specifications of Discoms . 12 KV I/D VCB SWITCH GEAR & CONTROL GEAR PANEL (O/G TYPE) 6 Nos
5 5 SITC of 36KV(800amp & making capacity 25-31.5ka) Indoor Type VCB Switch Gear & Control Gear Panel, is directly installed at site on a Trench/Floor .CTs,PTs and Scada enabled relay control panel is in-built in the metal enclosure. The power supply can be taken through Sufficient space for receiving the cables inside the switch board at the bottom of the cubicles and mounting arrangement for the terminal cable glands shall be provided. Includes all Accessories complete in all respect as per latest specifications of Discoms . 36 KV I/D VCB For Transformer 2 Nos
6 6 SITC of 36KV(800amp & making capacity 25-31.5ka) Indoor Type VCB Switch Gear & Control Gear Panel, is directly installed at site on a Trench/Floor .CTs,PTs and Scada enabled relay control panel is in-built in the metal enclosure. The power supply can be taken through Sufficient space for receiving the cables inside the switch board at the bottom of the cubicles and mounting arrangement for the terminal cable glands shall be provided. Includes all Accessories complete in all respect as per latest specifications of Discoms . 36 KV I/D VCB For Feeders 2 Nos
7 7 Supply of 1.1KV grade insulated hand gloves as per norms and specification of Discom. 2 Set
8 8 supply of first aid box as approved by st. john ambulance brigade/indian red cross conforming to relevant IS,as per Discom Norms and Specification. 1 Set
9 9 Supply and Fixing of PG clamps at bus bar jumpering point complete in all respect as per latest specifications of Discoms PG Clamp for ACSR Panther to Panther. 50 Nos
10 10 Supply and Fixing of T clamps at bus bar jumpering point complete in all respect as per latest specifications of Discoms T Clamp for ACSR Panther to Panther. 50 Nos
11 11 Supply and fixing of lightening arrestors set (3Nos)on the existing brackets in all respect as required including hardware, nut, bolt & washer etc. for O&M works complete in all respect as per latest specifications of Discoms. 33 KV Sub-station type (30KV 10 KA Sub-station Class) 2 SET
12 12 Providing & fixing weather proof metering cum control panel with 40cmx60cmx80cm' Height of 2 mm thick M.S. sheet as approved design with openable door on both side made out of frame an angle ron25x25x3 mm' with steel handle and panel lock duly painted with primer red oxide paint and two coats of gray paint of approved make quality. And with providing 6mm thick bakelite sheet of size80x60mm. Fixing of legs in pedestal 30 cm. deep and grouting with cement concrete 1:3:6 including excavation. Panel doors should be duly sealed with rubber gasket & 2 No' cable brass gland single compression type should be provided on bottom side with removable gland plate. A glass/wire mesh of required should also be provided on the door to take meter reading. 2 Nos
13 13 RTU complete with DI, DO, AI and modbus\ncommunication ports and power supply (24 V, DC) 1 lot
14 14 Programming and Troubleshooting software for RTU 1 lot
15 15 Quad-band GSM/GPRS modem with Ethernet bridge/router/ serial server (RS232/485) interface. 2 Nos
16 16 Panel Enclosure for RTU Location, wall/floor mounted along with wiring and related accessories and arrangement of mounting of RTU, Modem, UPS and having IP-42 Protection. Panels shall be self-fabricate type only. 1 Nos
17 17 Supply and fixing of 11KV, 400Amp. 3 Pole central pot rotating double break type isolator (IS: 9921 part I to V) without earth blade operating mechanism with GI spring loaded reverse loop type fixed contact, solid hard drawn electoytic copper tubular moving contact with silver/nickel plated at end points, 9 nos. pot insulator of 12KV (IS:2554 & IS:5350 part III), hot dipped galvanizing hard ware, nut bolts, etc. complete in all respect as per latest specifications of Discoms (Type tested by ERDA/CPRI).` 4 Nos
18 18 Supply and fixing of distribution type lightening arrestor 9 kv 10KA (IS:3070) with mounting breaking to be installed on existing DP structure (Type tested by ERDA/CPRI) 9 Nos
19 19.1 Supply and fixing 11KV Disc Insulator120KN (IS:731/1971) with minimum creepage distance of 300mm. on existing bracket including all accessories like hot dipped GI spindle and nuts etc as per latest specifications of Discoms )B&S type hardware 45KN. 6 Nos
20 19.2 B&S disc Insulator 45KN. 12 Nos
21 20.1 Supply and fixing 33KV Disc Insulator120KN (IS:731/1971) with minimum creepage distance of 300mm. on existing bracket including all accessories like hot dipped GI spindle and nuts etc( as per latest specifications of Discoms )B&S type hardware 120KN. 6 Nos
22 20.2 B&S disc Insulator 120KN. 18 Nos
23 21 Plate Earthling as per IS: 3043 with G.I Earth plate of size 600 mm x 600 mm x 6.0 mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia G.I. “B” Class watering Pipe including all accessories like nut bolt reducer nipple wire meshed funnel and C.C. finished chamber covered with hinged type with locking arrangement C.I Cover C.I Frame of size 300 mm x 300 mm complete with alternate layers of salt and coke/ charcoal testing of earth resistance as required. 100 Nos
24 22 Maintenance free gel earthing with pipe in pipe/pipe in strip technology filled with anti corrosive conductive compound (CPRI tested) below the ground in 150-200mm dia. Earth pit & surrounding filled with required mineral filling compound (MFC should have hygroscopic property to ratain the moisture for long time to create low resistance zone) and C.C. finished chamber covered wiht hinged type with locking arrangement C.I. cover CI frame of size 300mmx300mm complete testing of earth resistance as required of following sizes.with strip in pipe technology 80-100 micron GI coating.GI pipe 3000mm long, 63/80mm, Inner Strip 50mm x 3mm copper. 20 set
25 23.1 S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface /recess including riverting, soldering, saddles, making connection etc. as required. 50mm x 6 mm GI (hot Dipped) Strip 300 Mtr
26 23.2 50mm x 6 mm Copper Strip 100 Mtr
27 23.4 25mm x 3mm G.I. ( Hot Dipped ) Strip 500 Mtr.
28 24 SITC of Star rated aluminium wound distribution Transformer of following rating 11/0.433KV Delta-star Connected, Vector Group Dyn 11, as per BEE star level -2 & BIS approved with losses as defined as per IS 1180 PART 1 2014. including standard accessories like conservator , silica gel breather, radiator, fins, HT cable box & LT cable boxes, off - LTC(+5% to -10% @ 2.5%) winding temperature gauge, first fill of oil, epoxy based paint, including carrying of pre-commission testing & Charging of Transformer.(Transformer should be CTL tested , w/o any extra cost) 100 KVA (group I ) 1 Nos
29 25.1 P/laying P.V.C /XLPE insulated & P.V.C. sheathed cable of 1.1 k.v. grade with aluminum conductor of IS 1554 P-1/7098 P-I of Group I of approved make in ground as per IS : 1255 including excavation of 30 cm x 75 cm size trench, 25 Cm thick under layer of sand, 11nd class bricks covering, refilling earth compaction of earth making necessary connection testing etc. as required of size 3.5corex70sqmm. Armoured (Group -1) 2000 Mtr
30 25.2 3.5x185 sq.mm. Armoured(Group 1) 4000 Mtr
31 25.3 4corex10sqmm. Armoured( Group -1) 200 Mtr
32 25.4 4corex 2.5 sqmm Armoured ( Group -1) 100 Mtr
33 25.5 2core x10 sqmmArmoured( Group -1) 200 Mtr
34 25.6 1core x150sqmmArmoured( Group -1) 500 Mtr
35 25.7 4 coreX 25 Sqmm Armoured( Group -1) 5000 Mtr
36 25.8 3.5x120 sq.mm.Armoured( Group -1) 1000 Mtr
37 26.1 P/laying P.V.C /XLPE insulated & P.V.C. sheathed cable of 1.1 k.v. grade with Copper conductor of IS 1554 P-1/7098 P-I of Group I of approved make in ground as per IS : 1255 including excavation of 30 cm x 75 cm size trench, 25 Cm thick under layer of sand, 11nd class bricks covering, refilling earth compaction of earth making necessary connection testing etc. as required of size 12 corex1.5sqmm. Armoured( Group -1) 500 Mtr
38 26.2 12 coreX2.5Sqmm Armoured( Group -1) 200 Mtr
39 26.3 4 coreX2.5Sqmm Armoured( Group -1) 1200 Mtr
40 27 Supply ,Drawing and Testing of 4 pair,24 AWG UTP Cat 6 Cable as Per latest ammendments of TIA /EIA 568 B.2-1 Specifications in existing MS/PVC Conduits including making connections to information outlets and patch panels with ferruling at both ends for identification with necessary tools for punching,stripping crimping and testing required( Group -1) 300 Mtr
41 28.1 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C setting and conforming to IS 60947-2/IEC 60947-2 with front face and centralize adjustable, line load interchangeability having positive isolation capability provisions for UVR shunt trip, earth fault trip ,push test to trip including making connection with lugs/ spreaders etc. required. 100amp, 25ka, adjustable O/L & fixed S/C setting Ice=100%Icu.( Group -1) 2 Nos
42 28.2 200 Amp , 25/35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 1 Nos
43 28.3 up to 100 Amp , 10 kA, fixed O/L & S/C setting 150 Each
44 28.4 250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 100 Each
45 29 Providing and fixing bus bar chamber housed in sheet matal box made out from 1.2mm thick powder coated CRCA Sheet a front openable, bus bar made out of aluminium or wrought aluminium alloy suitable for 100amp. Capacity bus bar fixed on porcelain insulators at approved spacing including making connections etc. as required. 300mm long, 4 strip. 1 Nos
46 30.1 Providing and making heat shrinkable type indoor/outdoor/ straight through terminations/ joint kit of Group 1 and approved make suitable for XLPE insulated 11 K.V/33KVcable with required components preparation of cable ends testing etc as required of following size. 11kV End termination kit outdoor type 120/150/185/225 Sq.mm 4 Nos
47 30.2 11kv End termination kit outdoor type 240/300 Sq.mm. 2 Nos
48 30.3 11 KV End Termination Kit Indoor type 3 core 120/150/185/225 Sq.mm 4 Nos
49 30.4 11 KV End Termination Kit Indoor type 3 core 240/300 Sq.mm 2 Nos
50 30.5 33kv End termination kit outdoor type 240/400 Sq.mm. 4 Nos
51 30.6 33 KV End Termination Kit Indoor type 3 core 240/400 Sq.mm 4 Nos
52 31.1 P&F laying XLPE insulated IS: 7098/II/85 of Group I and approved make H.T. cable for working voltage 11 KV. Earthed direct in ground including excavating of 30 cm x 100 cm size trench 25 cm layer of river sand IInd class brick covering refilling earth compaction of earth making necessary connection testing etc. as required of size (Group 1). 3 core 185 sqmm. 400 Mtr
53 31.2 3 core 300 sqmm. 160 Mtr
54 32 P&F laying XLPE insulated IS: 7098/II/85 of Group I and approved make H.T. cable for working voltage 33 KV. Earthed direct in ground including excavating of 30 cm x 100 cm size trench 25 cm layer of river sand IInd class brick covering refilling earth compaction of earth making necessary connection testing etc. as required of size. (Group I).3 core 300 sqmm. 340 Mtr
55 33 Supply & fabrication steel structure with ms channel/angle/joist/ISMB/sheet etc. including welding rivetting cutting nut & bolt painting etc as required. 5000 kg
56 34.1 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1KV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.4x2.5sq.mm.( Group -1) 200 Mtr
57 34.2 1x4.0sq.mm.( Group -1) 300 Mtr
58 34.3 1x2.5sq.mm.( Group -1) 300 Mtr
59 34.4 1x1.5sq.mm.( Group -1) 300 Mtr
60 35.1 S & Laying following size B Class GI pipe confirming to IS:1239 P-1 (1990) with accessories for laying earth conductror/strip/cable in ground/surface /recess as required32mmdia 150 Mtr
61 35.2 100mmdia. 100 Mtr
62 35.3 125mmdia. 100 Mtr
63 36 P&F of IP 65/IP66 Protected LED street light luminaire on existing bracket fixture made from powder coated single piece pressure diae cast aluminium housing with heat dessipation fins on housing with UV stablized PC/Toughened Glass cover (from 45W onwards) and should be secondary lens on each LED .The system level luminaire efficacy >=100 with high power LEDs of CREE/NICHIA/OSRA/PHILIPS make to be used. The LED driver shall be BIS certified and input voltage AC 110 to 270 V AC with input frequency 50 HZ+-3% Power factor >0.95 Driver efficiency >85% THD(i)<10% Humidity 10% to 90% RH working temp. -20C to 50C . Life expectancy equal or more than 50000 burning hours with minimum 70% initial lumens maintained, rendering index >75% Surge protection shall be min>= 5KV internal and min 10 KV external. Manufactures word Mark/Name Engra ved/Embossed on die cast housing to allow tracebility/authenticity till life of fixture. fixtures shall be CE complianed. Group A-I LED Street Light Fixture 90 watt. 10 Nos
64 37 Supply and erection of MS swaged tubular pole as per IS 2713-1980 (Part I& II) and made out from tube of ISI mark for structural purpose with MS base plate in position including excavation of pit filling the same with c.c of M-20 grade (1:1:5:3) from bottom to 50 cm above the ground level with the help of steel frame of 40 cm dia up to bottom section of 114.3 mm OD & 50 cm dia beyond 114.3 mm OD around the pole. duly finished with cement plaster earthing terminal cable entry GI cable sleeve complete as required , the pole shall be fabricated by using ISI mark tube for structural purpose of following height & designation (See Table E-09 for specs.) 7.5Mtr Long. (410 SP-5) 10 Nos
65 38 Add for supply and fixing of MS Overhang of following size over the existing poles.88.9mm ODx3.25mm thickness. 10 Mtr
66 39 Providing and Fixing of IP65 Protectd polycarbonate/polysterene fuse box moulded with inside knock outs of following size with hinged cover, trasparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20mmx3mm flat with nut and bolts, complete with. The box shall be provided with Din rail, 4/8way 10.0/16.0 sq.mm heavy duty connector, earth terminal, complete in all respect.225mmx225mmx100mm ( Group -1) 10 Nos
67 40 P&F 240/415V AC MCB with positive isolation of breaking capacity not less than 10KA (B/C/D tripping characteristic) ISI marked IS 8828(1996)1/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required. Single Pole 6Ato 32Arating.( Group -1) 920 Nos
68 41 Double Pole 6Ato 32Arating.( Group -1) 20 Nos
69 42 Supplying and drawing overhead steel core Aluminum conductor (ACSR) ISI marked (IS 398 part II- 96) on existing cross arms through insulator with necessary T&P required including bidding and twisting etc. complete in all respect as required as per Discom specification
70 42.1 100sqmm of (6/4.72mm+1/1. 57mm) Dog Conductor 100 Mtr
71 42.2 Panther Conductor 200 Mtr
72 43 Supply & fixing ISI Marked (IS:15683) portable fire exitnguisher, ABC type, finished externally with red enmel paint, complete in all respects including initial fill and wall suspension of following capacity. 9Kg. 7 Nos
73 44 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size.
74 44.1 3.5 x 70.0 sq.mm 102 Set
75 44.2 3.5 x 120.0 sq.mm 100 Set
76 44.3 3.5 x 185.0 sq.mm 200 Set
77 44.4 4corex10sqmm. 20 Set
78 44.5 3 core X 150Sqmm 100 Set
79 45.1 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, copper lugs duty crimped with crimping tool, PVC tape etc for following size of armoured PVC insulated & PVC sheathed XLPE aluminium conductor cable of 1100Volt grade as required of size.4x2.5sq.mm. 100 Nos
80 45.2 2 x 4.0 sq.mm 50 Nos
81 46 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, round tiles,Hot Dipped Galvanized Modular Box of 20 SWG with earth terminal, 6 A Modular switch,Modular plate with grid plate, screws, making connections, testing etc. as required.
82 46.1 Short point upto 3 Mtr. 5 p.point
83 46.2 Medium point upto 6 Mtr. 15 p.point
84 46.3 Long point upto 10 Mtr. 10 p.point
85 47 Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal, 6 A modular switch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required.
86 47.1 On board 10 p.point
87 47.2 Short point (up to 3 mtr.) 4 p.point
88 47.3 Medium point (upto 6 Mtr. ) 4 p.point
89 48 S&F following sizes dia of ISI marked medium duty PVC conduit along with accessories in surface/recessed using saddles, clamps, fastener as required including cutting the wall covering conduit with wire mesh and making good the same as required. 25mm.Group-I 100 R Mtr
90 49 P&F 1200mm sweep BEE 5 star rated double ball bearing capacitor start, aluminium body & blade ceiling fancomplying to IS 374:1979,I/p 50watt at max speed & 230Volt,air delevery>210CMM,RPM with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc. as required Group 1 10 Nos
91 50 P & F of IP20 LED batten tube light 20watt with external batten made from CRCA sheet steel suitable to replace T 8/ T 12 tube light, integral driver 2000 lumen+ 5% tolrance system lumen efficiency 100 lm /Watt minimum expected life time of 25000 burning hours , CCT 5700 K ,ANSI CRI 80 ,driver efficacy >85%,Life expectancy of driver min 30000 Hr. PF0.95 at full load/230 volt AC Group 1 12 Each
92 51 P&F Recessed/surface mounting heavy duty horizontal type sheet steel distribution board phophatised/powder painted complete with suitable rating insulated copper bus bar, shorting link, neutral link, earth link and din bar, conforming to ISI 13032 & IS8623 including making internal DB terminations with copper lugs, testing etc, as required. 12way.( Group -1) 1 Nos
93 52 P&F 240/415V Isolator conforming to IS:13947-III/IEC 60947-3 on existing board /sheet including making connections with lugs, testing etc as required. Double pole Isolator 63A rating ( Group -1) 4 Nos
94 53 P&F double ball bearing capacitor start, single phase metallic blade fresh air fan 8in existing opening including cost of hardware flexible copper conductor making connection testing etc. as required 300 mm sweep.( Group -1) 1 Nos
95 54 P&F of Gravity louver shutter of superior quality made out of PVC including cost of nuts, bolts etc as required upto 380 mm size.( Group -1) 1 Nos
96 55 P/laying ISI marked PVC insulated submersible cable confirming to IS:694 with flexible copper conductor including making conncetion etc. as required. 6.0sqmm 3core flat/round( Group -1) 250 Mtr
97 56 SITC of radial/mixed flow submersible motor pump sets ISI marked (IS: 8034-1989) of approved make with required accessories including making connection suitable for T.W./ D.C.B/Open Well. The job includes lowering of riser pipe, G.I./ H.D.P.E. Pipe with rope, cables, installation of complete fitting and accessories, jointing of electrical cables up to switch board. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. 100mm diameter submersible pump shall have following HP rating phase Head minimum Discharge respectively.
98 56.1 3.0HP,3phase,(33-90),(166-60)LPM( Group -1) 1 Nos
99 57 Providing of HDPE pipe ISI mark (IS:4984/95) for water supply (suitable for submersible pupe & jet pump) with required fittings 50mm OD 6kg/cmsq.( Group -1) 200 R Mtr
100 58 Supply and fixing of oil /Air break Starter panel made out of sheet steel powder coated enclosourecomprising of over load protection relay, short circuit & single phasing protection ,ON/OFF push Buttons,ammeter,voltmeter, indicating lamps etc complete in all respect suitable for following rating motors
101 58.1 For Three phase Submersible /mono block pump 3.0hp to 10.0hp(DOL)Group 1 1 Each
102 59 SITC of FCBC (Float cum boost charger)suitable for 415V+/-10%, 50 Hz, 1-#/3 & 24/48/110 V DC OutputNatural Cooled, free standing in sheet Steel enclosure, SCR controlled, regulation +/-1%, Efficency > 75% on FCAC/DC instruments, Selector Switch , Built in DC Distribution Board (6 No MCB), Indication, control as required of following rating: 25A + 25A 1 Nos
103 60 Supply and fixing 11Kv pin insulator (IS 731/1971) with minimum creep age distance of 300 mm on existing bracket including all accessories like hot dipped GI spindle and nuts etc(as per specification Discom) 6 Nos
104 61 SITC of battary bank of min 150 AH capacity comprising SMF/VRLA batteries, MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: 110V DC( Group -1) 1 Nos
105 62 Supply and installation of spike of M.S. rod 20mm dia 3.0mtr long for earthing of (tower/pole) drive into earth by mechnical means sturture connection the spike with cross arm top hamper PCC Pole, lattice tower to earth etc, complete technical specification of discom. 20 Nos
106 63 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m , disposed earth to be levelled and neatly dressed: All kinds of soil 200 cum
107 64 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed with a lead in a 50 meter including stacking of useful material if available : Hard rock (blasting prohibited) useful material 30% 300 cum
108 65 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level M10 grade Nominal Mix \n1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). 100 cum
109 66 Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix\n 150 cum
110 67 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 (1 cement : 6 sand) 130 cum
111 68 Random Rubble stone masonry with hard stone in superstructure above plinth level and upto Three Levelabove 30cm. thick walls in :Cement Mortar 1:6 ( 1-Cement : 6-Sand). 150 cum
112 69 Centering and Shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. 250 sqm
113 70.1 Centering & shuttering with plywood or steel Plate including strutting, propping bracing both ways with steel props and removal of formwork for upto floor Three level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. 600 sqm
114 70.2 Columns, pillars, posts and struts etc. 60 sqm
115 71 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 150 cum
116 72 Random rubble dry stone Kharanja under floor. 100 cum
117 73 Flyash Lime Gypsum Brick Works with Flyash Lime Gypsum Brick Works of class designation 75 in superstructure above plinth level upto floor Three Level in all shapes and sizes in : Cement mortar 1 : 3 (1 cement : 3 coarse sand) 150 cum
118 74 Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor Three level excluding the cost of centering and shuttering.M20 grade Nominal Mix \n1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 10 cum
119 75 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor Three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix 100 cum
120 76 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand) 500 sqmm
121 77 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished :20mm thick 1500 sqm
122 78 Providing and fabricating steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete upto floor three level. Hot rolled deformed bars (IS : 1139). 16000 kg
123 79 Supplying and fixing in walls machine cut and polished stone shelves, tands and sills in CM 1:3 with machine cut edges : Kota stone 25 to 30mm thick 10 sqm
124 80 Polished Blue Kota stone flooring skirting, laid over 20 mm thick base of C.M. 1:4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :For area of each slab from 901 to 2000 Sq.Cm : 30 mm thick slab. 400 sqm
125 81 Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design & IS 6248- 1979. (Clear openable area to be measured for payment) 30 sqm
126 82 Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately)Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron) 200 kg
127 83 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge (cost of aluminium snap beading shall be paid in basic item) With glass panes of 4.0mm thickness (weight not less than 10.0 kg/sqm) as per IS:2835. 40 sqm
128 84 Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 2 Nos
129 85 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S.With stainless steel cover plate 4 Nos
130 86 Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 10 sqm
131 87 Providing and fixing M.S. sheet single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint M.S. Sheet 22 S.W.G. 2.5 sqm
132 88 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping and priming coat with cement primer. 1000 sqm
133 89 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 1500 sqm
134 90 Painting with ready mix paint of approved brand and manufacture in all shades to give an even shade: New steel work (two or more coats). 100 sqm
135 91 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 100 sqm
136 92 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 40 sqm
137 93 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm. 1 Each
138 94 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. 1 Each
139 95 P&F WVC Wash Basin (1st quality IS:2556 mark) of approved make with CI brackets duly painted, 1 no. 15mm CP Pillar cock (IS:8934 mark) & 32 mm CP brass waste coupling of approved make, 25mm GI waste pipe complete including cutting & making good the wall. Size 550mm × 400mm 1 Each
140 96 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556mark). Of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall:PVC with PVC bend as per IS : 7231 . 1 Each
141 97 P & F Flush Pipe of approved make with complete fittings for high level flushing cistern:G.I. `B` class (Concealed) 32 mm. 1 Each
142 98 P& F waste Coulping with fittings of approved quality /make:C.P Brass 32 mm dia 1 Each
143 99 P&F Ball cock (IS:1703 mark) with rod & PVC ball complete : Brass wt.Not less than 400 gm, 20mm 2 Each
144 100 P&F 15mm dia connection pipe of approved quality/make : PVC pipe with CP brass nuts upto length 300mm 4 Each
145 101 P&F inlet connection (Angle, Valves) superior quality, of approved make for washbasin Gyser etc. C.P. inlet connection 15mm brass (IS:8931 marked) 4 Each
146 102.1 P&F full-way valve (IS:778 mark) or wheel valve of approved make : Gun metal 15mm nominal bore 2 Each
147 102.2 Gun metal 25mm nominal bore 2 Each
148 103 P&F PVC storage tank conforming to IS : (12701 marked indicating the BIS License No.) of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25cm long wash out pipe with plug & socket, including making connection etc. complete of approved design. 300 ltr. Capacity 2 Each
149 104 Providing and fixing sand cast iron floor trap (Nahni) of (IS:1729 mark) of approved quality/make with socket down or hinged grating including cutting and making good the floor. Size 100×100mm 4 Each
150 105 P&F square-mouth gully trap ‘A’ grade (IS : marked) of approved make complete with C.I. grating, frame & cover masonry chamber in CM 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C. M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type. Trap size 150×100mm, 7.2kg C.I. cover with frame, internal chamber size 300×300mm 1 Each
151 106 Construction of Chamber in all types of soil with 300mm thick masonry in CM 1:6m 100mm thick CC 1:5:10 in foundation 20mm thick insider plaster in cm 1:6, finished with floating neat cement, 50mm thick M-15 grade CC flooring, earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 300 X 300 mm depth upto 0.5 M Cement cover with frame.. 1 Each
152 107 Construction of Manhole in all types of soil inner size 90×60cm with 300mm thick masonry in CM 1:6, 10cm thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade CC flooring, 25kg, CI cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50mtr. lead. Depth upto 0.5m 3 Each
153 108 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 230 x110 x150 cm.(for 20 users) 1 Each
154 109 Providing laying & jointing glazed SW pipes grade ‘A’ (IS:651 marked) of approved make with spun yarn & stiff mixture of cement mortar 1:1 excavation & refilling of earth in all types of soil upto 1.2m depth, SW fittings, including testing of joints etc. complete.100mm dia 20 R Mtr
155 110.1 P&F rigid PVC pipe [IS:4985 mark] class-II [4 kg/cm2] approved quality/make including jointing the pipe with solvent cement rubber ring and lubricant : 75 mmdia 10 R Mtr
156 110.2 110mm dia. 50 R Mtr
157 111 P&F rigid PVC pipe fitting (IS:4985 mark) of approved quality/mark including jointing the fitting with solvent cement rubber ring and lubricant : Vent Cowel 110mm. 2 Nos
158 112 P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make :CP brass push type 25mm nominal bore. 2 Nos
159 113 Construction of tube-well upto 100 mtr. depth and above in all type of rocks by DTH system and over burden, to accommodate casing pipe of following sizes in all types of soils and over-burden including lowering of casing pipes, but excluding cost of casing pipes as per IS:2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube-well should have a throughout bore as per nominal dia of casing pipe : 150mm dia nominal bore 250 Mtr
160 114 Supply of ERW M.S. black casing pipe ISI marked (IS:4270/1992) of grade Fe410 of following sizes at site of work.Nominal bore of pipe (mm)150 20 Mtr
161 115 S&F M.S. clamp, set of 50×6mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 2 Nos
162 116.1 Providing and fixing 3-layer PP-R (Polypropylene random coplymer ) pipes SDR 7.4 UV stabilized and antimicrobial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings and fixing the pipe with clamps at 1.00 spacing. This includes cost of cutting chases and making good the same including testing of joint complete as per direction of Engineer - in charge.(CONCELED WORK INCLUDING CUTTING CHASES AND MAKING GOOD THE WALL ETC.)PN-16 Pipe, 20 mm OD 100 Rm
163 116.2 PN-16 Pipe, 32 mm OD 50 Rm
164 117 Supply of Stone Aggregate (Single size) : 40 mm nominal size 100 cum
165 118 Supply and fixing of Fiber-reinforced Ferro Cement drain cover (light duty) designated for class"B" loading duly marked on cover with adequate steel reinforcement having thickness 50 mm to 75mm, anti corrosive bitumen painted M.S. Plate rim and on M.S. lifting hooks, additives and admixture like plasticizer, shrinkage resristance compound, abrasion resistant etc. as per approved drawing and design complete in all respect. Span 451mm to 700mm Standard Size 1000*800mm 100 sqm
166 119 Interlocking Paver Blocks having 80 mm thickness in M-40 grade concrete Providing and Laying 80 mm thick cement concrete blocks of M-40 Grade (Manufactured with fully mechanised dry cast process with forced action mixer whose arms revolve along the main axis and rotate about its own axis also, having humidity sensor for moisture control of w/c ratio in concrete mix. Manufactured with steel moulds(Milled and manufactured in CSI diamond or CSI Nitro process for accuracy) on steel base plate of min 16 mm thick; Having Vibration and pressing action both together with the help of mutiplesynchronised vibrators. Power of hydraulic station should be minimum 50KW for compaction and cured in controlled chambers having humidity control and automated air circulation system) spreading 25mm thick sand underneath and filling joints with sand on existing W.B.M.base, as per IS15658:2006 and all materials shall conform to MoRTH Specification Clause 602. 200 sqm
167 120 Construction of embankment with approved material abtained from borrow pits with all lifts and leads transpoeting to site sperading grading to required slope and compaction by vibratory roller 8-10 tonn to meet requirement of table 300-2 including cost of compaction for earth taken from private land with all leads and lift as per morth specification clause no 305 1500 cum
168 121 Providing and fixing concertina coil fencing with required dia 610 mm (having 15 nos. round per 6 metre length) up to 3m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. stud tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron all complete as per direction of Engineer In Charge with reinforced barbed tape (R.B.T.)/Spring core(2.5 mm thick) wire of high tensile strength of 165 kg/sq.mm with tape (0.52 mm thick) and weight 43.478 gm/metre (Cost of MS angle, CC block shall be paid extra) 130 Mtr
169 122 SITC of Wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, duly treatd for derusting in 7 tank process with dephosphating and with power coating on both side of panel in desired shade. The panel having PU/neoprene rubber gasket of not less than 3mm thickness, separate detachable gland plate M.S. base channel hinged door with locking arrangement for equipment/switchgear thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. Channel if required. Side walls and cable alley compartment having bolted type doors with detachable extension type structure.(Only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator)( Group -1) 170 Sq. Mtr.
170 123 P&F paper phenolic resin bonded laminates comfirming to IS :2036-1995 for boxes/frames including making holes for switches fet, with brass screws, washers/zinc plated nut and bolts as required. 9.0mm thick. Group 1 70 Sq. Mtr.
171 124 Supply and fixing of aluminium/copper bus bar by means of SMC/DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending cutting in required shape and size and colour coding with heat shrinkable PVC sleeves.Electrolytic grade aluminium bus bar. 400 Kg.
172 125 P & F following modular acessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required.Group 1
173 125.1 16A one Way Switch 10 Each
174 125.2 16A 6 pin shuttered socket 10 Each
175 125.3 5 step fan regulator 2 Module 10 Each
176 126 P&F IS:371 marked 6amp surface type ceiling rose including making connection testing etc. as required. 20 Nos.
177 127 P&F ISI marked 6 amp Bakelite batten/angle holder including making connection testing etc. as required. 10 Nos.
178 128 P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required of Gemini or IS:14930 marked make. Outer Dia. / Inner dia.
179 128.1 50/55 mm 2998 Mtr.
180 128.2 90 / 76 mm 3000 Mtr.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy