Repair Maint Of Internal Electrification At Old Cantt Jnm Axis Under Ge Gangtok, Gangtok-Sikkim

Military Engineer Services-MES has published Repair Maint Of Internal Electrification At Old Cantt Jnm Axis Under Ge Gangtok. Submission Date for this Tender is 23-06-2020. Electrification Work Tenders in Gangtok Sikkim. Bidders can get complete Tender details and download the document.




Tender Notice

24416347
Corrigendum : Repair Maint Of Internal Electrification At Old Cantt Jnm Axis Under Ge Gangtok
Open Tender
Indian
Sikkim
Gangtok
23-06-2020

Tender Details

Repair Maint Of Internal Electrification At Old Cantt Jnm Axis Under Ge Gangtok

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Jun-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-06-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

Name of Work:REPAIR/MAINT OF INTERNAL ELECTRIFICATION AT OLD CANTT AND JNM AXIS UNDER GE GANGTOK.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SCHEDULE 'A' PART-I (E/M WORKS) BI01010001010000000000000515BI0100001113
2 1.01 Taking down carefully point wiring of any type (i.e. on wooden batten, surface conduit, casing-N- capping or concealed conduit) complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, conduit etc. including accessories such as wooden gutties/rawal plug, screw etc including making good disturbed surface to match the existing surface all as specified & directed. 851 Each
3 1.02 M & L for point wiring with 1.5 Sqmm PVC insulated unsheathed single core stranded copper conductor (FRLS) Cable of working voltage 1100 Volts grade conforming to IS-694 pt-I & II of 2000 drawn in and including 25 mm size PVC rigid non matellic casing caping (Double lock) with all casing capping fittings & accessories with 1.60 mm thick pressed steel or mild steel sheet sunk box covered with 3 mm thick backelite sheet fixed with brass screws & cup washers including 1.5 sqmm PVC insulated unsheathed single core stranded copper conductor (FRLS) cable as earth continuity conductor connected to main switch / DB's or common earth dolly complete for for light point/ fan point/ exhaust fan point/ call bell point/ controlled by one switch 5/6 Amp one way complete all as specified and directed. 430 Per Point
4 1.03 All as per item no.2 but one light point controlled by two 2-way switches 5/6 Amps 3 Per Point
5 1.04 All as per item No.2 here-in-before but for one 3 pin socket outlet point, 5/6 Amps on independent board with other switch complete all as specified & as directed. 80 Per Point
6 1.05 All as per item no.2 but for One bell/ buzzer point controlled by one push buttonon the same board with other switches or independent with cables1.5 sq.mm. size switches 5/6 Amps 3 Per Point
7 1.06 All as per item No 2.00 here-in-before but one socket outlet / metal clad socket of 15/16 amps switch socket outlet on independent board with 2.50 Sqmm PVC (FRLS) insulated un-sheathed copper conductor cable multistranded conductor 1100 volts grade and 2.5 Sqmm copper conductor cable (FRLS) as earth continuity conductor complete all as specified & as directed. 250 Per Point
8 1.07 All as per item No.2 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and directed by Engineer-in-Charge 30 Per Point
9 1.08 M & L for Rewiring with 1.5 Sqmm PVC insulated unsheathed single core stranded copper conductor (FRLS) Cable of working voltage 1100 Volts grade conforming to IS-694 pt-I & II of 2000 drawn in and including in existing surface/ recessed steel/PVC conduit including 1.5 sqmm PVC insulated unsheathed single core stranded copper conductor (FRLS) cable as earth continuity conductor connected to main switch / DB's or common earth dolly complete for light point/ fan point/ exhaust fan point/ call bell point controlled by one switch 5/6 Amp one way complete including dismantling as required all as specified and directed.\n 40 Per Point
10 1.09 All as per item No.8 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 2.5 Sq mm multistranded copper conductor wire FRLS PVC insulated and 2.5 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and directed by Engineer-in-Charge 15 Per Point
11 1.1 All as per item no.8 but for One bell/ buzzer point controlled by one push buttonon the same board with other switches or independent with cables1.5 sq.mm. size switches 5/6 Amps 3 Per Point
12 1.11 S&F in repairs switch piano, flush type, 6 amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge\nMake : Anchor Product Code No 50053 or equivalent of approved make 430 Each
13 1.12 S&F in repairs switch piano flush button,single pole, two way, 6 amps complete.\nMake : Anchor Product Code No 50064 or equivalent of approved make 3 Each
14 1.13 S&F in repairs bell push, flush type, 6 amps, 240 volts ISI marked all as specified and directed.\nMake : Anchor Product Code No 50075 or equivalent of approved make 6 Each
15 1.14 S&F in repairs bell ding dong, AC single pole 220/240 volts white/ivory finish, surface type complete(Make : Anchor Product Code No 50075 or equivalent of approved make 6 Each
16 1.15 S&F in repairs switch socket combination, 2 and 3 pin, 5/6 amps, multipurpose, flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete all as directed including taking down old one. Make : Anchor Product Code No 4056/50483 or equivalent of approved make 80 Each
17 1.16 S&F in repairs switch socket combination, 2 in 1, 6 pin, 5/6 Amps and 15/16 Amps, multipurpose , flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete complete all as directed including taking down old one. Make : Anchor Cat No 38808/50665 or equivalent of approved make 335 Each
18 1.17 S&F in repairs ceiling rose, PVC/polycarbonate insulated body, 3 terminal and 240 volts, ISI marked complete all as specified and directed\nMake : Anchor Product Code No 39040 or equivalent of approved make 300 Each
19 1.18 S&F in repairs lamp holder angular/straight insulated body, with back plate suitable for batten fittings, white/ivory finish complete all as directed.\nMake : Anchor Product Code No 39527 or equivalent of approved make 150 Each
20 1.19 S&F in repairs sheet metal enclosure for 4 way Distribution Boards (DB’s), triple pole and neutral double door with IP-43 protection suitable for fixing MCB's/lsolators after and including taking down old DB with MCB complete all as specified and as directed.\n(Make : L&T cat No DBTPE004DD or equivalent/approved. 2 Each
21 1.2 S&F in repairs sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 8 way with 200 Amps rated copper bus bar double door type complete and including taking down old DB with MCB complete all as specified and as directed. Havells/ABB/Legrand, L&T Cat No. DBSPN008DD or equivalent/approved) 12 Each
22 1.21 S&F in repairs sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 4 way with 200 Amps rated copper bus bar double door type complete and including taking down old DB with MCB complete all as specified and as directed.\n(Make : L&T cat No DBSPN004DD or equivalent/approved) 4 Each
23 1.22 S&F MCB single pole & neutral 40 to 63 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge.\n(Make : L&T cat No BB20400C to BB20630C or equivalent/approved) 16 Each
24 1.23 S&F in repairs MCB single pole 6 to 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. \n(Make : L&T cat No BB10060C to BB10320C or equivalent/approved) 80 Each
25 1.24 S&F in repairs MCB, Triple pole & neutral, 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed \n(Make : L&T cat No BB40630C or equivalent/approved) 2 Each
26 1.25 S&F in repairs T8 fittings with IP 20, Class I, LED light fitting 1 x 18 W (4 FT), CRI >=80, CT >=5700K, wall / surface mounted, integrated type, constructed of fire retardant engineering grade extruded plastic & decorative end caps with integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with suitable fixing arrangements complete including 01 No 18 W (4 FT) LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size all as specified and as directed. (Make : Havells Cat No REGALBATTEN8UPTO1X22WSSBSWH and Tube light Cat No TITANIANEO1213T8SSTL18WLED865SPC or equivalent/approved).\n 257 Each
27 1.26 Supply and fix in repairs integrated LED bulk head fittings of 10 watts, presure die cast housing acrylic diffuser and frame with IP 66 protection complete all as specified and as directed Make : Havells Cat Part No.HEXAFT10WLED857SSYMBOPCLBHE or equivalent/approved). 15 Each
28 1.27 S&F in repairs aesthetically designed 2x2 LED flat panel for surface mounting which provides soft light and glare free illumination 34 watts, including and connecting up all as specified and as directed. (Make : Havells Cat No PLUTOSURFACE2X2PLS34WLED857S or equivalent/approved) 4 Each
29 1.28 S&F in repairs Exhaust Fan 300 mm Sweep, 1400 RPM, 240 Volt, AC 50 HZ, metallic body, including lovers with and including cutting bricks/stone boulders wall for fixing of fan and finished the cutting surface even and smooth by using cement morter complete all as specified and directed.( Make:- Havells Ventil Air-DB or equivalent of EPC/Crompton Greaves) 12 Each
30 1.29 Supply, install, testing & commissioning of electric water heater, storage vertical type, 4 star rated, 25 ltr capacity comprising of high wattage heating element for instant heating, extra thick inner tank of superior grade, rust & shock proof ABS outer body, non-ferrous pressure plate with & incl provn of 04 Nos grouting bolts suitably flushed to wall or any other surface incl water & electric connection with 3 core PVC insulated, sheathed, standed copper conductor cable/flexible chord complete fixed in repairs all as specified and as directed. Make : - Havells Cat No - GHWAMGTWH025 or is equivalent/approved). 20 Each
31 1.3 M&L for submain wiring alongwith earth wire of size 2x6.0 Sqmm + 1x6 Sqmm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor single core cable drawn in and incl PVC casing and caping of adequate size with all accessories as required as specified and as directed incl taking down old unserviceable submain wiring. (Note : Three runs of PVC wire with one run of PVC casing and caping will be measured and paid as one length.) 150 RM
32 1.31 M&L for submain wiring alongwith earth wire of size 2x4.0 Sqmm + 1x4 Sqmm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor single core cable drawn in and incl PVC casing and caping of adequate size with all accessories as required as specified and as directed incl taking down old unserviceable submain wiring. (Note : Three runs of PVC wire with one run of PVC casing and caping will be measured and paid as one length.) 150 RM
33 1.32 M & L for earthing complete in repairs with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continious earth wire on pole, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 1991 print and as directed . 6 Each Job