Military Engineer Services-MES has published Special Repairs Bldg To Bldg No P 2 Offrs Md Accn At Vlo An Spl Repair Bldg Complete Rewiring Including Led Light Fitting At Or Md Accn Balwant Line Bldg No P 135 At Cmp Centre And School Under Ge South Bangalore As Per Boq And Tender Document. Submission Date for this Tender is 23-06-2020. Electrification Work Tenders in BANGALORE Karnataka. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 03-Jun-2020 | BOQ Corrigendum | BOQ | 16-06-2020 |
2 | 16-Jun-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-06-2020 |
Name of Work : SPL REPAIRS(BLDG) TO BLDG NO P-2 (OFFRS MD ACCN) AT VLO AND SPL REPAIR (BLDG) COMPLETE REWIRING INCLUDING LED LIGHT FITTING AT OR MD ACCN, BALWANT LINE (BLDG NO P-135) AT CMP CENTRE AND SCHOOL UNDER GE (SOUTH) BANGALORE | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolition of cement concrete n exc 15 cm thickness in any position below or above ground level including removing of demolished materials outside the MD land complete all as specified and as directed. | 1.5 | Cum | |
2 | 2 | Demolition of concrete of any description and in any position not otherwise specifically provided for including removing of demolished materials outside the MD land complete all as specified and as directed. | 1 | Cum | |
3 | 3 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. | 0.5 | Cum | |
4 | 4 | Taking down door shutter with frame (without taking off shutter from frame) exc 1.5 sq m but n.exc 4 sq m complete all as specified and directed. | 6 | Each | |
5 | 5 | Taking down door shutter with frame (without taking off shutter from frame) n.exc 1.5 sq m complete all as specified and directed. | 6 | Each | |
6 | 6 | Taking down, easing, adjusting and refixing in same opening as required, shutters of any description exc 1 Sqm and n exc 2 Sqm each complete all as specified and as directed. | 24 | Each | |
7 | 7 | Taking down shutters of any description exc 1.00 Sqm but n. exc 2.00 Sqm complete all as specified and directed. | 2 | Each | |
8 | 8 | Taking down shutters of any description n. exc 1.00 Sqm complete all as specified and directed. | 4 | Per Leaf | |
9 | 9 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises complete all as specified and directed. | 235 | Sqm | |
10 | 10 | S&F 35 mm thick second class hard wood glazed and skelton shutters open rebated and prepared to receive glass , gauge etc divided in to squares with plain, chamfered or rounded mittered and rebated sash bars any numbers, edges of framing plain chamfered complete all as specified and directed. | 3 | Sqm | |
11 | 11 | S&F 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. | 6 | Sqm | |
12 | 12 | S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought frame rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. | 0.12 | Cum | |
13 | 13 | S&F 30 mm thick IInd class hard wood glazed and skelton shutters open rebated and prepared to receive glass , gauge etc, but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any number into squares with plain, chamfered or rounded mittered and rebated sash bars any numbers, edges of framing plain chamfered complete all as specified and directed. | 3 | Sqm | |
14 | 14 | S&F anodised aluminium frame for doors,windows,ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. | 30 | Kg | |
15 | 15 | S&F mild steel work in window guard bars, plain, let in and fixed independently in wooden frames and similar work confirming to Fe 410 -O or Fe 310 -O complete all as specified and directed. | 25 | Kg | |
16 | 16 | Cutting holes into or through brick walls built in cement mortar superficial area exc 150 sqm but n. exc 400 sq cm complete all as specified and directed. | 100 | CMD | |
17 | 17 | S & F solid door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube , supplying and fixing in opening as per specification and drawing complete all as specified and directed. | 18 | RM | |
18 | 18 | S&F factory made solid pannel PVC door shutter 30mm thick (style) consisting of frame made out of MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck in side with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame wedded /sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement supplying and fixing in the frame at site including two nos tower bolts/ handles for each shutter as per specification and drawing. | 6 | Sqm | |
19 | 19 | S&F 4 mm thicksheet glass ordinary quality in square not exceeding 0.5 Sqm each fixed to wooden /steel frames incl necessary beading/putty complete all as specified and directed. | 6 | Sqm | |
20 | 20 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. | 8 | Sqm | |
21 | 21 | S&F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. | 28 | Sqm | |
22 | 22 | S&F 100 mm long medium weight, cold rolled mild steel butt hinges complete all as specified and directed. | 24 | Each | |
23 | 23 | S&F continuous (piano) hinges, width of flaps (when open) 30mm made of mild steel, bright finish or electrogalvanised complete all as specified and directed. | 20 | RM | |
24 | 24 | S&F 75 mm long medium weight, cold rolled mild steel butt hinges complete all as specified and directed. | 30 | Each | |
25 | 25 | S&F 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. | 28 | Each | |
26 | 26 | S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section | 28 | Each | |
27 | 27 | S&F in repairs 150 mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. | 20 | Each | |
28 | 28 | S&F 375 mm mild steel ordinary rat rail rod pattern springs including roller and roller plate complete all as specified and directed. | 4 | Each | |
29 | 29 | S&F 100 mm aluminium anodised hasp and staple, safety type complete all as specified and directed. | 8 | Each | |
30 | 30 | M&L for 10mm thick rendering in CM (1:4) on brick or stone wall surface finished even and fair to receive tiles complete all as specified and directed. | 25 | Sqm | |
31 | 31 | M&L for 15mm thick screed bed or bedding layer in CM (1:6) for laying floor finishes complete all as specified and directed. | 212 | Sqm | |
32 | 32 | M&L for PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) 25 mm thick as in levelling course complete all as specified and directed. | 80 | Sqm | |
33 | 33 | M&L for non - skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. | 10 | Sqm | |
34 | 34 | M&L for light shaded vitrified tiles 10 mm thick (square/rectangular) polished, area of each tiles n.exc 0.36 sqm,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. | 200 | Sqm | |
35 | 35 | M&L for coloured glazed ceramic tiles in vertical surface 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing complete all as specified and directed. | 10 | Sqm | |
36 | 36 | M&L for light shaded vitrified tiles 10 mm thick and 100 mm high in vertical surfaces (square/rectangular) polished, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. | 15 | Sqm | |
37 | 37 | M&L for 20mm thick granite telephonic black including round cutting work for wash hand basin /sink (table rubbed and polished) as in cooking platforms and like over and including 20mm thick screed bedding layer in cement mortar 1:4 including pointing in coloured cement to match with the shade of granite including rounding of exposed edges complete all as specified and directed. | 2 | Sqm | |
38 | 38 | M&L for machine cut cudappah stone 20-25mm thick over 20mm thick screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and directed. | 2 | Sqm | |
39 | 39 | Rounding to edges of stone slabs one edge, such as in steps,ooking platform, and other similar situations complete all as specified and directed. | 5 | RM | |
40 | 40 | M&L for 600x450mm bevelled edge mirror of selected quality glass,mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. | 5 | Each | |
41 | 41 | S&F mirror cabinate of size 300mmx450mm mirror of selected quality fixed in wall with screws complete all as specified and directed. | 4 | Each | |
42 | 42 | S&F in repair wash down water closet (pedastal pattern), (excluding fixing bolt, seat cover,flushing cistern, flushing pipe) complete all as specified and directed. | 2 | Each | |
43 | 43 | Supply only plastic seat cover, coloured closed pattern flat bottom and cover and CP hinging device complete all as specified and directed. | 2 | Each | |
44 | 44 | S&F in repairs wash hand basin under counter basin oval size 195X505x410mm incl cutting for pinning in ends of brackets, waste pipe and waste coupling complete all as specified and directed. | 2 | Each | |
45 | 45 | S&F in repairs 10 ltr capacity PVC valveless syphopnic action type flushing cistern, low level, coloured, with inlet, ball valve, float and handle including brackets and flush pipe complete all as specified and directed. | 2 | Each | |
46 | 46 | S&F hot and cold wall mixer of size 15mm bore with 115mm long bend pipe for connection to over head shower with aerator fixed to wall etc complete all as specified and directed. | 2 | Each | |
47 | 47 | S&F in repairs 15mm dia bib cock long thread, cast copper alloy fancy type, chromium plated screwed down, high pressure, with capstan head, screwed down screwed for iron pipe complete all as specified and directed. | 2 | Each | |
48 | 48 | S&F in repairs 15mm dia two way bib cock, cast copper alloy fancy type, chromium plated screwed down, high pressure, with capstan head, screwed down screwed for iron pipe complete all as specified and directed. | 2 | Each | |
49 | 49 | S&F in repairs swivel shower rose of brass chromium plated 150 mm dia round with shower arm of 190mm long light body complete all as specified and directed. | 2 | Each | |
50 | 50 | S&F in repair 15mm bore pillar tap cast copper alloy, chromium plated, fancy type with capstan head, high pressure long neck with aerator with long screwed shank and fly nuts complete all as specified and directed. | 2 | Each | |
51 | 51 | S&F in repairs stainless steel health faucet with PVC tube 1.00m long and holder with screwed nut for inlet connection of 15mm bore fixed to stop cocks faucet complete all as specified and directed. | 2 | Each | |
52 | 52 | S&F in repairs 15mm dia chromium plated angular stop cock fancy type male end complete all as specified and directed. | 4 | Each | |
53 | 53 | S&F in repairs chromium plated toilet paper holder fancy type complete all as specified and directed. | 2 | Each | |
54 | 54 | S&F in repairs chromium plated tubular towel rail D type 20mm dia 600mm long fixed with CP screws complete all as specified and directed. | 2 | Each | |
55 | 55 | S&F stainless steel soap dish of approximate size 160x160x90mm complete all as per specified and directed. | 2 | Each | |
56 | 56 | S&F 15 mm bore dia medium grade galvanised water tubing, with all fitting, fixed complete to walls and ceilings or laid in floors, including taking down old unserviceable GI tubing complete all as specified and as directed. | 40 | RM | |
57 | 57 | S&F 20 mm bore dia medium grade galvanised water tubing, with all fitting, fixed complete to walls and ceilings or laid in floors, including taking down old unserviceable GI tubing complete all as specified and as directed. | 25 | RM | |
58 | 58 | M&L for brick work sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed. | 2 | Cum | |
59 | 59 | M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed. | 10 | Sqm | |
60 | 60 | M&L for rendering 10mm thick in CM 1:6 on fair face of brick or concrete surfaces of walls finished even and smooth without using extra cement complete all as specified and as directed. | 20 | Sqm | |
61 | 61 | M&L for 75mm thick PCC 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and as directed. | 30 | Sqm | |
62 | 62 | M&L for 75mm thick PCC 1:4:8 type D-2, using 40 mm graded stone aggregate as in sub base of flooring complete all as specified and as directed. | 20 | Sqm | |
63 | 63 | M&L for 50mm thick PCC 1:2:4 type B-1, using 20 mm graded stone aggregate as in base course of flooring complete all as specified and as directed.\n | 20 | Sqm | |
64 | 64 | M&L for preparation of old plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed. | 30 | Sqm | |
65 | 65 | Demolition and breaking up drain pipes upto 110mm dia (salt glazed stone ware, AC or PVC , reinforced concrete, CI pipe) set in cement mortar complete all as specified and as directed. | 60 | Rm | |
66 | 66 | M&L for providing cement concrete 1:5:10 type E-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. | 1.5 | Cum | |
67 | 67 | Spply only ISI marked water proofing compound complete all as specified and as directed. | 25 | Kgs | |
68 | 68 | S&F PVC (SWR) 110 mm bore pipes single socketed, in any length with rubber ring joints laid in floors complete all as specified and as directed. | 10 | RM | |
69 | 69 | S&F PVC (SWR) 75 mm bore pipes single socketed, in any length with rubber ring joints laid in floors complete all as specified and as directed. | 10 | RM | |
70 | 70 | S&F PVC (SWR) 75 mm bore pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and as directed. | 20 | RM | |
71 | 71 | S&F PVC (SWR) 110 mm bore pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and as directed. | 20 | RM | |
72 | 72 | S&F PVC (SWR) 110 mm bore bends with access door complete all as specified and directed. | 4 | Each | |
73 | 73 | S&F PVC (SWR) 75 mm bore bends with access door complete all as specified and directed. | 6 | Each | |
74 | 74 | S&F 110 mm PVC (SWR) junction single, (single T) equal or unequal with acess door complete all as specified and directed. | 4 | Each | |
75 | 75 | S&F 75 mm PVC (SWR) junction single, (single T) equal or unequal with acess door complete all as specified and directed. | 4 | Each | |
76 | 76 | S&F PVC (SWR) 110 mm vent cowl complete all as specified and directed. | 4 | Each | |
77 | 77 | S&F 25 mm dia fancy type brass bracket with screws including wooden plugs complete all as specified and directed. | 24 | Pair | |
78 | 78 | S&F 25 mm dia fancy type brass bracket with screws for wall corners including wooden plugs complete all as specified and directed. | 5 | Pair | |
79 | 79 | S&F fancy type aluminium powder coated curtain rods 25 mm dia complete all as specified and directed. | 24 | RM | |
80 | 80 | S&F in repairs 75mm dia PVC (SWR) floor trap, plain with grating including solvent cement complete all as specified and directed. | 7 | Each | |
81 | 81 | S&F in repair 15mm size PVC connection 450mm long complete all as specified and directed. | 8 | Each | |
82 | 82 | Taking down cement plaster on walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. | 80 | Sqm | |
83 | 83 | M&L for 5mm thick rendering in CM (1:3) on concrete surfaces of walls complete all as specified and directed. | 10 | Sqm | |
84 | 84 | M&L for 15mm thick cement plaster with CM 1:6 on fair faces of brick/concrete surfaces finished even and smooth (with out using extra cement) complete all as specified and directed. | 30 | Sqm | |
85 | 85 | M&L for rendering 5 mm thick in cement mortar 1:4 on other than fair face of brick or concrete surfaces mixed with WPC @3% by weight of cement over 15 mm thick in cement plaster in CM 1:6 finished even and smooth without using extra cement all as specified and as directed.\n(Note:- Water proofing compound shall be measured and paid separately under relevant item of this schedule) | 40 | Sqm | |
86 | 86 | M&L for preparation of newly plastered surface of wall including three coats of white wash complete all as specified and directed. | 10 | Sqm | |
87 | 87 | M&L for preparation of newly plastered surface of ceiling including three coats of white wash complete all as specified and directed. | 10 | Sqm | |
88 | 88 | M&L for preparation of newly plastered surface of walls and applying two coats of cement based paint including priming with alkali resistant primer complete all as specified and directed. | 40 | Sqm | |
89 | 89 | M&L for preparing newly plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed. | 20 | Sqm | |
90 | 90 | M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. | 24 | Sqm | |
91 | 91 | M&L for preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. | 12 | Sqm | |
92 | 92 | M&L for PCC 1:2:4 type B0 using 12.5mm graded stone agg for filleting and benching slightly rounded or chamfered on edges complete all as specified and directed. | 0.8 | cum | |
93 | 93 | Excavation in trenches , not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc. and getting out in soft/loose soil complete all as specified and directed. | 2 | Cum | |
94 | 94 | Removing excavated surplus soil exc 250m and n.exc 500m depositing where directed at a level not exec 1.5m above the starting point complete all as specified and directed. | 0.8 | Cum | |
95 | 95 | Returning, filling in, including spreading, leveling, watering and well ramming in layers in soft/loose soil not exceeding 25 cm with soils complete all as specified and directed. | 1.2 | Cum | |
96 | 96 | S&F 12 mm ply wood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified and directed. | 10 | Sqm | |
97 | 97 | S&F plain fillets exc 13 & n exc 25 sqcm square, rectangular or triangular in section, clean sawn se-cured with nails/ screws complete all as specified and directed. | 40 | Rm | |
98 | 98 | S&F 75 mm brass handles cast type polished bright complete all as specified and directed. | 8 | Each | |
99 | 99 | S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with choromium plated bracket guard and railing 60 cm long complete all as specified and directed. | 2 | Each | |
100 | 100 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. | 641 | Per Point | |
101 | 101 | M&L for point wiring with concealed type with PVC insulated, unsheathed, single core multistranded copper conductor cable (FRLS) of size 1.5 Sqmm, 1100 volts grade including 1.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through 20mm dia PVC conduit ISI marked with its acessories and sunken box and frame cover plate for mounting as required at site for switches/sockets/regulators etc for one light /CB/fan point controlled by one switch complete all as specified and as directed.\n(Note :- MS Sunken boxes, cover plates with frame switches, sockets shall be measured and paid seperately under relevent items of this Schedule. Fixing of sunken box and cover with frame is included in quoted rate.) | 140 | Per Point | |
102 | 102 | All as per item No. 101 here-in-before but for one 3 pin 5 Amps socket outlet point on independent board complete all as specified and as directed. | 48 | Point | |
103 | 103 | All as per item No. 101 here-in-before but for one 3 pin 5 Amps socket outlet on the same board with other switches complete all as specified and as directed. | 16 | Point | |
104 | 104 | All as per item No 101 here-in-before but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 6 pin 15 amp socket outlet on independent board complete all as specified and as directed. | 32 | Point | |
105 | 105 | S&F bell push modular type 5A one way complete all as specified and as directed. | 4 | Each | |
106 | 106 | S&F switch modular type 5A one way complete all as specified and as directed. | 136 | Each | |
107 | 107 | S&F one way switch 16A one module complete all as specified and as directed. | 32 | Each | |
108 | 108 | S&F socket outlet 2 in 1, 3 pin, 5 Amps modualr type complete all as specified and as directed. | 64 | Each | |
109 | 109 | S&F socket outlet 6/16 Amps modular type complete all as specified and as directed. | 32 | Each | |
110 | 110 | S&F stepped type electronic fan regulator modular type, complete all as specified and as directed. | 20 | Each | |
111 | 111 | S&F ceiling rose surface bakelite 65 x 50mm 3 terminals complete all as specified and as directed. | 406 | Each | |
112 | 112 | Taking down fan, dismantling blades and removing fan and blades to store, painting of celing fans complete, in situ with one coat of synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dust etc. and hanging in original position and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed. | 20 | Each | |
113 | 113 | All as per item No. 112 here-in-before but exhaust fan of any sweep complete all as specified and as directed. | 8 | Each | |
114 | 114 | Dismantling existing serviceable geyser of any capacity and refixing the same including provn of PVC connection of suitable length as per item obtained above complete all as specified and as directed. | 8 | Each | |
115 | 115 | Material and labour for sub main wiring with two runs of single core, PVC insulated unsheathe multi-stranded copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi-stranded copper conductor cable (FRLS) for earth continuity conductor drawn through and including ISI marked rigid PVC casing and caping with all necessary accessories including taking down old unserviceable wiring complete all as specified and directed. \n(Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm earth continuity conductor and one run of PVC casing and caping with all necessary accessories will be measured as one length). | 126 | RM | |
116 | 116 | Supply, fabricate, test and ommissioning wall mounting meter box of size 900mm x 900mm x 200mm depth concealed type, powder coated made out of 2.0mm thick CRCA sheet, weather and vermin proof with double stud hinged door front open with internally and externally locking arrangement and 3mm thick hylam sheet fixed inside box including dismatling of old meter box with old meters and cutouts from old meter box and refixing energy meter, cutout in new box complete all as specified and directed. \n(Note : For removing of old meter, permission shall be taken from concerned BESCOM and the rate for the same shall be included in the quoted rate.) | 1 | Job | |
117 | 117 | S&F TPN DBs-ETPN DBs with provision for FP MCB/Isolator as incomer and SP MCB as outgoing IP 43 IK 09 with metal door 4 way including taking down old unserviceable one complete all as specified and directed. \nMake :- Legrand Cat Part No 607715 or equivalent make of ABB/L&T | 1 | Each | |
118 | 118 | S&F sheet metal enclosure (for DB's when MCBs to be used), single pole and neutral, 12 way, 240 Volts, single door with 200 Amps rated bus bar including taking down old unserviceable one complete all as specified and directed.\n | 4 | Each | |
119 | 119 | Supply and fix sheet metal enclosure (for DB's when MCBs to be used), single pole and neutral, 8 way, 240 Volts, single door with 200 Amps rated bus bar including taking down old unserviceable one complete all as specified and directed.\n | 4 | Each | |
120 | 120 | Supply and fix sheet metal enclosure (for DB's when MCBs to be used), single pole and neutral, 2 way, 240 Volts, single door with 200 Amps rated bus bar including taking down old unserviceable one complete all as specified and directed.\n | 4 | Each | |
121 | 121 | S&F MCB DP 32Amps including taking down old unserviceable MCB complete all as specified and directed.\n | 12 | Each | |
122 | 122 | S&F MCB SPN 40Amps including taking down old unserviceable MCB complete all as specified and directed.\n | 4 | Each | |
123 | 123 | S&F MCB FP 415 Volt 63Amp capacity complete all as specified and directed.\nMake -Legrand Cat No 408794 or equivalent make of ABB/L&T | 1 | Each | |
124 | 124 | S&F sheet metal enclosures with socket plug top and MCB' single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 A MCB complete all as specified and directed.\n | 10 | Each | |
125 | 125 | S&F LED batten 18/20 watt, 4 feet long suitable for indoor applications with integrated electronic driver of operating voltage 110 to 270 Volts , constructed of fire retardant engineering grade extruded plastic and decorative end caps including connecting up and taking down existing unserviceable light fittings complete all as specified and as diretcted. \nMake: Crompton Cat No LCTL-18-CDL/Bajaj Cat No. BCLSBAL 20 CW/C&S Cat No LTTB2F20WLED/W or equivalent in Wipro/Havells | 130 | Each | |
126 | 126 | S&F LED batten 9/10 watt, 2 feet long suitable for indoor applications with integrated electronic driver of operating voltage 110 to 270 Volts , constructed of fire retardant engineering grade extruded plastic and decorative end caps including connecting up and taking down existing unserviceable light fittings complete all as specified and as diretcted. \nMake:- Crompton Cat No LCTL-9-CDL/Bajaj Cat No. BCLSB 10 WH/C&S Cat No LTTB2F10WLED/W or equivalent in Wipro/Havells | 42 | Each | |
127 | 127 | S&F LED batten 7 watt, mirror light fittings with integrated electronic driver of operating voltage 110 to 270 volts including connecting up and taking down existing unserviceable surface/ceiling mounted light fittings complete all as specified and as diretcted. \nMake:- Crompton Cat No LCL-7-CDL or equivalent in Wipro/Havells. | 12 | Each | |
128 | 128 | M&L for point wiring surface type with single core 1.5 Sqmm PVC insulated unsheathed single core multistranded copper conductor cable (FRLS) including 1.5 Sqmm PVC insulated unsheathed copper conductor as earth continuity conductor drawn through 20mm dia PVC conduit ISI marked with its acessories, and fixed in existing sunken boxes and covered with 3.00 mm thick ISI marked laminated sheet cover and brass screws with cup washers for fixing switches/sockets/regulators etc for one light/CB/fan point controlled by one switch complete all as specified and as directed. | 270 | Each | |
129 | 129 | All as per item No. 128 here-in-before but for one 3 pin 5 Amps socket outlet point on independent board complete all as specified and directed.\n | 45 | Point | |
130 | 130 | All as per item No. 128 here-in-before but for one 3 pin 5 Amps socket point on the same board with other switches complete all as specified and directed.\n | 45 | point | |
131 | 131 | S&F in repair call bell, musical type, 230 volts AC single pole complete all as specified and directed.\n | 15 | Each | |
132 | 132 | All as per item No 128 here-in-before but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 3 pin 15 amp socket outlet complete all as specified and as directed. | 45 | Point | |
133 | 133 | S&F switch piano, flush type single pole, one way 5 Amps complete all as specified and as directed. | 315 | Each | |
134 | 134 | S&F switch socket combination 2 in 1, 3 pin 5 Amps flush type universal complete all as specified and as directed. | 45 | Each | |
135 | 135 | S&F switch socket combination 2 in 1, 3 pin, 5 Amps and 15 Amps flush type universal complete all as specified and as directed. | 45 | Each | |
136 | 136 | S&F switch socket outlet 2in1, 3pin, 5A complete all as specified and as directed. | 45 | Each | |
137 | 137 | S&F stepped type electronic fan regulator flush type, 230 volt complete all as specified and as directed. | 45 | Each | |
138 | 138 | S&F MCB single pole, 240 volts 6 to 32 Amps including taking down old unserviceable one complete all as specified and directed.\n | 139 | Each | |
139 | 139 | S&F MCB single pole and neutral 06 to 32 Amps, 240 Volts including taking down old unserviceable one complete all as specified and directed.\n | 15 | Each | |
140 | 140 | S&F MCB triple pole and neutral 63 Amps, 415 Volts including taking down old unserviceable one complete all as specified and directed.\n | 2 | Each | |
141 | 141 | Supply and fix sheet metal enclosure (for DB's when MCBs to be used), single pole and neutral, 8 way, 240 Volts, double door with 200 Amps rated bus bar including taking down old unserviceable one complete all as specified and directed.\n | 15 | Each | |
142 | 142 | S&F sheet metal enclosure (for DB's when MCBs to be used), single pole and neutral, 12 way, 415 Volts, double door with 200 Amps rated bus bar including taking down old unserviceable one complete all as specified and directed.\n | 2 | Each | |
143 | 143 | M&L for sub main wiring with two runs of single core, PVC insulated, unsheathed multi stranded copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including ISI marked 20mm dia rigid PVC conduit with necessary accessories such as bends, tees, junction boxes, elbows etc including taking down old unserviceable submain wiring complete all as specified and as directed. \n(Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length). | 50 | RM | |
144 | 144 | S&F LED batten, 5 watt, 1 feet long, suitable for indoor applications with integrated electronic driver of operating voltage 110 to 265 Volts lumin output not less than 900 lm including connecting up and taking down existing unserviceable light fittings complete all as specified and as diretcted.\nMake:- Bajaj Cat No. BCLSB 05 NW/C&S Cat No. LTTB1F5WLED/W | 45 | Each | |
145 | 145 | S&F in repair LED bulk head 10 watt with PDC aluminium housing and milky diffuser including connecting up and taking down existing unserviceable light fittings complete all as specified and as diretcted.\nMake:- Bajaj Cat No. BIBWP10WLED/C&S Cat No. LTB10WLED/Crompton Cat No LBH-10-CDL | 6 | Each | |
146 | 146 | Supply and laying or fixing or passing in trenches/ on pole / through pipes, 1100 volts grade XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of cross sectional area 4 core 35 sq mm including connection with cable glands & lugs etc and testing on completion including taking out old unserviceable cable complete all as specified and directed.\nNote: Excavation & earth work, sand cushioning and bricks,GI protection pipes shall be measured and paid seperately under respective items of this Sch. | 30 | RM | |
147 | 147 | Supply and laying or fixing or passing in trenches/ on pole / through pipes, 1100 volts grade XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of cross sectional area 3.5 core 50 sq mm including connection with cable glands & lugs etc and testing on completion including taking out old unserviceable cable complete all as specified and directed.\nNote: Excavation & earth work, sand cushioning and bricks,GI protection pipes shall be measured and paid seperately under respective items of this Sch. | 35 | RM | |
148 | 148 | Excavation in trenches , not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc. and getting out in hard/dense soil complete all as specified and directed. | 9 | Cum | |
149 | 149 | Returning, filling in, including spreading, leveling, watering and well ramming in layers in hard/dense soil not exceeding 25 cm with soils complete all as specified and directed. | 1.08 | Cum | |
150 | 150 | Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. | 7.92 | Cum | |
151 | 151 | M&L for sand cushioning to under ground cable in layers ( 8 cm before laying the cable and 15 cm after laying the cable and punned into 18 cm thickness) in trenches for cable protection complete all as specified and directed.\nNote : - Punned thickness only will be measured and paid. | 3.24 | Cum | |
152 | 152 | Supplying and laying sub class 'B' bricks locally available best quality, designation 75 for cable protection complete all as specified and as directed. | 0.347826 | PER 1000 NOS | |
153 | 153 | S&F GI pipe light grade 50 mm for cable protection under road/floor or fixed to wall/panel complete all as specified and as directed. | 7 | RM | |
154 | 154 | M&L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished iron earth wire 4mm dia by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC (1:3:6) type C-1 (with 20mm graded stone aggregate),chamber and 50mm thick precast RCC (1:2:4) cover slab re-inforced with XPM Jalli including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. | 3 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail