Irrigation And Public Health Department has published Providing Lwss To Phatti Peej , Phatti Khahrahal Phatti Balh , Barahar And Kadihar In Tehsil Bhunter Distt Kullu H . P . Sh-Const . Of Pump House , Sanitary Tank Electrical Fitting , Septick Tank Cnst . Of Rcc Storagetank Of Various Capacity , Pro. Submission Date for this Tender is 16-06-2020. Anchors Tenders in kullu Himachal Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: Providing LWSS to Phatti Peej , Phatti Kharahal,Phatti Balh, Barahar and Khadiar in tehsil and district Kullu ( SH:- C/O Pump house, sanitary fitting, electrical fitting. septic tank ,C/O RCC Storage tanks of various capacity, Providing ,laying jointing & testing of Rising main, distribution system, providing and errection of Pumping machinery and C/O anchor block ) Estimated Cost :- 23794887/- EMD :-270450/- Time:- 12 Months | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | SCHEDULE -A CIVIL WORKS Excavation in foundation and trenches up to all depths and in all classification of earth work such as pick work, jumper work, situated soil including bailing or pumping out water, blasting soft/ hard rock, chiseling /wedging of soft / hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking, timbering and dewatering wherever required. Stacking usable and unusable material /soil separately and after laying jointing and testing of pipes, returning the usable soil in 15cm layers by ramming and watering and then disposing of all surplus excavated soil/ unusable material as directed with in all leads/ lifts including restoration of un-metalled surfaces to its original conditions and including cost of diversion for traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. Complete in all respects within all leads and lifts as per direction of the Engineer-in-Charge. | BI01010001010000000000000515BI0100001114 | 15988.2 | Cum |
2 | 2 | Providing and laying cement concrete 1:6:12 (1cement: 6 sand: 12 graded crushed stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts . | BI01010001010000000000000515BI0100001115 | 9.86 | Cum |
3 | 3 | Providing form work with steel plates 3.15mm thick welded with angle iron in frames 30x30x5mm so as to give a fair finish including centering ,shuttering, propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plain concrete work in all leads and fifts:- | BI01010001010000000000000515BI0100001116 | ||
4 | 3.01 | Foundation, footings basis of columns etc. and mass concrete. | BI01010001010000000000000515BI0100001117 | 123.04 | Sqm |
5 | 3.02 | Columns, pillars, posts and struts up to floor two level (Square rectangular polygonal in plain) | BI01010001010000000000000515BI0100001118 | 134.4 | Sqm |
6 | 3.03 | Vertical surfaces such as wall(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like - | BI01010001010000000000000515BI0100001119 | 2475.76 | Sqm |
7 | 3.04 | Flat surfaces such as soffits of suspended floors roofs landings and the like floors etc. up to 200 mm in thickness with in all leads and lifts. | BI01010001010000000000000515BI0100001120 | 233.71 | Sqm |
8 | 3.05 | Beam cantiliver girders and lintels Sides and soffits of beams, beam haunchings, cantilevers, bressumers and lintels not exceeding 1 Mtr. in depth in all heights from floor. | BI01010001010000000000000515BI0100001121 | 272.44 | Sqm |
9 | 3.06 | Edges of slab and breaks in floors and walls under 20 cm wide with in all leads and lifts.. | BI01010001010000000000000515BI0100001122 | 171.2 | Rmt |
10 | 3.07 | Arches, dom, vaults upto all span | BI01010001010000000000000515BI0100001123 | 400.32 | Sqm |
11 | 4 | Providing and laying cement concrete work 1:1.5:3 (1cement :1.5 sand: 3 graded crushed stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. in: - | BI01010001010000000000000515BI0100001124 | ||
12 | 4.01 | Foundation footing bases of columns and like mass concrete | BI01010001010000000000000515BI0100001125 | 118.11 | Cum |
13 | 4.02 | In suspended floor roofs landing shelves & their support balconies, beams, girders bressumers cantilevers upto floor two level with in all leads and lifts. | BI01010001010000000000000515BI0100001126 | 73.81 | Cum |
14 | 4.03 | Column,pillars post and struts upto floor two level | BI01010001010000000000000515BI0100001127 | 12.6 | Cum |
15 | 4.04 | Wall ( any thickness but not less than 0.10 mtrs. Thickness) including attached pillasters buttresses, plinth and string courses etc. from top of foundation level upto floor two level. | BI01010001010000000000000515BI0100001128 | 197.4 | Cum |
16 | 4.05 | Beam cantiliver girders and lintels Sides and soffits of beams, beam haunchings, cantilevers, bressumers and lintels not exceeding 1 Mtr. in depth in all heights from floor. | BI01010001010000000000000515BI0100001129 | 9.81 | cum |
17 | 5 | Providing wood work in frames of doors, wndows, clerestory windows and other frames wrouhgt, frramed and fixed in position in 1st class Deodar wood within all leads and lifts as per direction & satisfaction of Engineer-in-charge. | BI01010001010000000000000515BI0100001130 | 1.39 | Cum |
18 | 6 | Providing and fixing panelled glazed or panelled and glazed shutters for doors, windows and clerestory windows i/c bright finished black enammeled iron hinges with necessary screws: 2nd class deodar wood 40mm thick including entire carriage of material as per satisfaction of Engineer-in-charge. | BI01010001010000000000000515BI0100001131 | 52.92 | Sqm |
19 | 7 | Providing and fixing wire gauge shutters using galvanised M.S.wire gauge of I.S gauge designation 85 G with wire of dia 0.56mm for doors windows and clerestory windowsincluding bright finished black enamelled iron hinges with necessary screws 40mm thick 2nd class deodar wood. | BI01010001010000000000000515BI0100001132 | 49.77 | Sqm |
20 | 8 | Tor steel reinforcement for RCC work including bending, binding & placing in position complete upto floor two level i.c cost of binding wire with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. | BI01010001010000000000000515BI0100001133 | 34384.6 | Kg |
21 | 9 | Random rubble masonry/polygonal rubble masonry (uncoursed/brought to courses) with hard stones of approved quality in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement :6 sand : 12 graded stone aggregate 20mm nominal size) at plinth level in Cement Mortar 1:6(1 cement:6 sand) | BI01010001010000000000000515BI0100001134 | 37.69 | Cum |
22 | 10 | Providing and laying 20cm thick composit stone masonry with stone facing of chisel dressed stones one line dressed in cement mortar 1:6 (1cement :6sand) and concrete backing with cement concrete 1:3:6 complete up to floor two level.nominal size)on inner face of walls including centring , shuttering and propping(1cement:3sand:6graded stone aggregate,20mm | BI01010001010000000000000515BI0100001135 | 180.45 | Sqm |
23 | 11 | 15 mm cement plaster in single coat on rough side of brick/concrete stone walls for interior plastering up to floor two levels including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortar 1:6 (1 cement:6 sand) with in all leads and lifts | BI01010001010000000000000515BI0100001136 | 251.35 | Sqm |
24 | 12 | 6mm cement plaster to ceiling in CM 1:3 ( 1Cement :3 Sand) finished with a floating coat of neat cement and thick coat brush on top of when dry for bearing of RCC slabs and beam with in all leads and lifts | BI01010001010000000000000515BI0100001137 | 87.61 | Sqm |
25 | 13 | White washing with lime on undecorated wall surfaces(two coats) to give an even shade including thoroughly brooming the surface to remove all dust dirt & other foreign matter with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. | BI01010001010000000000000515BI0100001138 | 338.96 | Sqm |
26 | 14 | Applying priming coat on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,greese,dirt and other foreign matters,sand papering and knotting.Ready mixed paint brushing wood primer pink with in all leads and lifts. | BI01010001010000000000000515BI0100001139 | 93.56 | Sqm |
27 | 15 | Painting two coats (excluding priming coat) on new wood and wood based surfaces,with readt mixed paint to give an even shade including cleaningthe surface of dirt ,dust and other foreign matters sand papering and stopping with ready mixed paint other than white with in all leads and lifts. | BI01010001010000000000000515BI0100001140 | 93.56 | Sqm |
28 | 16 | Steel work in builtup section including cutting hoistig R.S. Joints channel angles iron 65x65x6mm thick angle iron for posts and applying a priming coat of red lead steel paint. | BI01010001010000000000000515BI0100001141 | 3312.76 | Kg |
29 | 17 | Providing corrugated G.I Sheet roofing fixed with GI J or L hooks bolts and nuts 8mm dia within bitumen and GI limpet washers filled with white lead complete including the cost of purlins rafters and trusses 0.63mm thick. | BI01010001010000000000000515BI0100001142 | 187.95 | Sqm |
30 | 18 | Providing ridges or hip 60cm over all in plain with GI, G.I sheet fixed J or L hooks bolts and nuts 8mm dia with in bitumen and G.I limpet washers filled with white lead complete including the cost of purlins ratters and trusses 0.63mm thick | BI01010001010000000000000515BI0100001143 | 17.9 | Rmt |
31 | 19 | Supplying and fixing rolling shutter of approved make made of 80mmx1.25 mm M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with bracket side guides and arrangement for inside and outside locking with push pull operation complete but excluding the cost of the top cover and spring shutter having width below 3.5 meters within all leads and lifts. | BI01010001010000000000000515BI0100001144 | 7.83 | Sqm |
32 | 20 | Providing and fixing aluminium tower bolts(barrel type)anodized transparent or dyed to required shade and colour with screws etc.complete 150x10mm. | BI01010001010000000000000515BI0100001145 | 80 | each |
33 | 21 | Providing and fixing aluminium handles anodized transparent or dyed to required colour or shade with necessary screws etc. complete with in all leads and lifts 100mm | BI01010001010000000000000515BI0100001146 | 40 | each |
34 | 22 | Providing and fixing anodized alumnium sliding door bolt anodized transparent or dyed torequired colour and shade with bolts and nuts and screw complete with in all leads and lift 250x16mm | BI01010001010000000000000515BI0100001147 | 4 | Each |
35 | 23 | Providing Stone soling properly hand packed tightly under floor with in all leads and lifts | BI01010001010000000000000515BI0100001148 | 131.08 | Cum |
36 | 24 | 40mm thick cement concrete flooring 1:2:4(1cement 2sand 4 graded stone agg.20mm nominal size ) including finishing the top surface of concrete smooth with in all leads and lifts. | BI01010001010000000000000515BI0100001149 | 136.98 | Sqm |
37 | 25 | Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement: 3sand: 6 graded stone aggregate 20mm nominal size) including finishing the top surface of concrete smooth with in all leads and lifts | BI01010001010000000000000515BI0100001150 | 26.15 | Sqm |
38 | 26 | Providing 40x3mm flat iron hold fast 40cm long i.e fixing to from with 10mm dia bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm 1:3:6 ( 1cement 3 sand 6 graded stone agg. 40mm nominal size) | BI01010001010000000000000515BI0100001151 | 136 | Each |
39 | 27 | Brick work using common burnt clay building bricks in super structure above plinth level upto floor two level 2nd class bricks cement mortar 1:6(1cement:6sand) with in all leads and lifts. | BI01010001010000000000000515BI0100001152 | 2.42 | Cum |
40 | 28 | Providing and laying cement concrete 1:4:8 (1cement: 4 sand: 8 graded crushed stone aggregate 40mm nominal size )and curing complete excluding cost of form work in foundation and plinth with in all leads & lifts as per the entire satisfaction & direction of Engineer - in - charge. | BI01010001010000000000000515BI0100001153 | 10.74 | Cum |
41 | 29 | Half brick masonary in common burnt clay buildings bricks in cement mortar 1:4(1cement:4sand) 2nd class bricks with in all leads and lifts. | BI01010001010000000000000515BI0100001154 | 5.76 | Sqm |
42 | 30 | Providing and laying cement concrete 1:2:4 (1cement :2 Sand: 4 graded crushed stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. in:- | BI01010001010000000000000515BI0100001155 | ||
43 | 30.01 | Beam cantiliver girders and lintels Sides and soffits of beams, beam haunchings, cantilevers, bressumers and lintels not exceeding 1 Mtr. in depth in all heights from floor. | BI01010001010000000000000515BI0100001156 | 0.04 | Cum |
44 | 30.02 | Suspended floor, roofs, landings, shelves and their supports, balconies, beams and girders, bressumers and cantilevers upto floor two level including all leads and lifts etc. complete in all respect. | BI01010001010000000000000515BI0100001157 | 15.85 | Cum |
45 | 31 | 15 mm cement plaster in single coat on rough side of brick/concrete stone walls for interior plastering up to floor two levels including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortar 1:3 (1 cement:3 sand) with in all leads and lifts | BI01010001010000000000000515BI0100001158 | 30.96 | Sqm |
46 | 32 | Providing and laying cement concrete 1:2:4 (1cement :2 Sand: 4 graded crushed stone aggregate 40 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. in:- | BI01010001010000000000000515BI0100001159 | ||
47 | 32.01 | Foundation footing and base of coloumn etc. | BI01010001010000000000000515BI0100001160 | 51.6 | Cum |
48 | 33 | Providing and laying cement concrete 1:3:6(1 Cement :3 Sand : 6 graded stone aggregate 40mm nominal size)and curing complete excluding the cost of form work in foundation and plinth including all carriage of materials upto all leads and lifts complete in all respects. | BI01010001010000000000000515BI0100001161 | 109.75 | Cum |
49 | 34 | Providing and fixing MS man hole cover of size 600 x 600 mm made up of 3.15 mm thick plain MS sheet fixed in angle iron frame frame of 50x50x5mm supported with MS flat of 50x5mm at center of sheet including fising hold fast ,hinges and locking arrangement and lock of medium size etc complete in all respects as per the direction of Engineer-in-Charge. | BI01010001010000000000000515BI0100001162 | 28 | Each |
50 | 35 | Fixing GI pipe light grade for inlet, outlet , over flow and scour pipe complete in all respect in all leads and lifts. | BI01010001010000000000000515BI0100001163 | ||
51 | 35.01 | 65mm dia | BI01010001010000000000000515BI0100001164 | 180 | Rmt. |
52 | 35.02 | 80mm dia | BI01010001010000000000000515BI0100001165 | 18 | Rmt. |
53 | 36 | SCHEDULE -B SANITARY FITTINGS Providing and fixing Cera/Hindware make double symphonic “P” or “S” trap WC pan (two piece )complete in all respect. With built in cistern 10 litr capacity of required shade (CRUSE 2018) WC-1 | BI01010001010000000000000515BI0100001166 | 1 | Each |
54 | 37 | Providing and fixing Cera/Hindware make double symphonic “P” or “S” trap WC pan (indian type )complete in all respect. WC-2 | BI01010001010000000000000515BI0100001167 | 1 | Each |
55 | 38 | Providing and fixing 10 litr vitreous china high level flushing cistern of Hindware/ Cera make. | BI01010001010000000000000515BI0100001168 | 1 | Each |
56 | 39 | Providin and fixing plastic seat cover solid type | BI01010001010000000000000515BI0100001169 | 1 | Each |
57 | 40 | Providing and fixing vitreous china 55x40cm flat back wash basin ( White colour) with MS brackets duly painted (cornet-1008 of Cera/Hindware make.) | BI01010001010000000000000515BI0100001170 | 1 | Each |
58 | 41 | Providing and fixing PVC waste pipe 32mm nominal dia for wash basin and sink | BI01010001010000000000000515BI0100001171 | 1 | Each |
59 | 42 | Providing and fixing M.I. Union for wash basin or sink | BI01010001010000000000000515BI0100001172 | 1 | Each |
60 | 43 | Providing and fixing 450x600mm bevelled edge mirror of reputed make mounted on AC sheet and fixed with brass screws. | BI01010001010000000000000515BI0100001173 | 1 | Each |
61 | 44 | Providing chromium plated brass soap dish with brass bracket | BI01010001010000000000000515BI0100001174 | 1 | Each |
62 | 45 | Providing and fixing 15mm angle valve ISI (Heavy duty) | BI01010001010000000000000515BI0100001175 | 2 | Each |
63 | 46 | Providing and fixing PVC connection 15mm of superior quality | BI01010001010000000000000515BI0100001176 | 2 | Each |
64 | 47 | Providing and fixing 100mm dia CP grating for floor traps of superior quality | BI01010001010000000000000515BI0100001177 | 4 | Each |
65 | 48 | Providing and fixing CP Pillar tap 15mm with capstain | BI01010001010000000000000515BI0100001178 | 4 | Each |
66 | 49 | Providing & fixing CP 15mm dia short body bib tap | BI01010001010000000000000515BI0100001179 | 4 | Each |
67 | 50 | Providing and fixing spray flushing jet | BI01010001010000000000000515BI0100001180 | 4 | Each |
68 | 51 | Providing and fixing GMS tube heavy class ) including GI fitting of following dia:-15mm dia | BI01010001010000000000000515BI0100001181 | 36 | Rmt |
69 | 52 | Providing and fixing PVC pipe ISI marked make Jindle pipe 100 mm dia | BI01010001010000000000000515BI0100001182 | 60 | Rmt |
70 | 53 | Providing and fixing PVC pipe ISI marked make Jindle pipe 75mm dia | BI01010001010000000000000515BI0100001183 | 60 | Rmt |
71 | 54 | Providing and fixing PVC door bend of following dia :-100mm dia Door Bend | BI01010001010000000000000515BI0100001184 | 4 | Each |
72 | 55 | Providing and fixing PVC plain bend of following dia :-100 mm dia | BI01010001010000000000000515BI0100001185 | 4 | Each |
73 | 56 | Providing and fixing PVC plain bend of following dia :-75mm dia | BI01010001010000000000000515BI0100001186 | 4 | Each |
74 | 57 | Providing and fixing 500 ltr capacity Sintex/Diplast make water storage tank | BI01010001010000000000000515BI0100001187 | 1 | Each |
75 | 58 | SCHEDULE -C ELECTRICAL FITTINGS Re-wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface/recessed Steel / PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable including dismantling of the existing wiring as required. ( including switch & bakelite sheet etc.) | BI01010001010000000000000515BI0100001188 | 4 | Nos |
76 | 59 | Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required. | BI01010001010000000000000515BI0100001189 | ||
77 | 59.01 | i )2x1.5 Sq.mm | BI01010001010000000000000515BI0100001190 | 30 | Per/M |
78 | 59.02 | ii )2x4.0 Sq.mm | BI01010001010000000000000515BI0100001191 | 40 | Per/M |
79 | 59.03 | iii )2x6.0 Sq.mm | BI01010001010000000000000515BI0100001192 | 10 | Per/M |
80 | 60 | Supplying and fixing following rating Piano-type switch /socket on the existing switch box / cover including connections etc. as required. | BI01010001010000000000000515BI0100001193 | ||
81 | 60.01 | i ) S.P. 15/16 Amps one way switch, porcelain base/ piano type. | BI01010001010000000000000515BI0100001194 | 2 | Each |
82 | 60.02 | ii) S.P. 15/16 Amps socket outlet, porcelain base/ piano type. | BI01010001010000000000000515BI0100001195 | 2 | Each |
83 | 60.03 | iii ) Bell push, piano type. | BI01010001010000000000000515BI0100001196 | 2 | Each |
84 | 61 | Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/ recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required. | BI01010001010000000000000515BI0100001197 | 1 | Each |
85 | 62 | Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/ recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, painting etc. as required. | BI01010001010000000000000515BI0100001198 | 1 | Each |
86 | 63 | Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Double pole. Cat-A. | BI01010001010000000000000515BI0100001199 | 1 | Each |
87 | 64 | Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Single pole. Cat-A. (Mr. Rate) | BI01010001010000000000000515BI0100001200 | 1 | Each |
88 | 65 | Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps. Cat-A. | BI01010001010000000000000515BI0100001201 | 1 | Each |
89 | 66 | Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Double door-12 way | BI01010001010000000000000515BI0100001202 | 1 | Each |
90 | 67 | Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit, with 2-way, 5/6 amps piano type switch and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Group A. | BI01010001010000000000000515BI0100001203 | 1 | Each |
91 | 68 | Supplying and fixing ceiling rose on the existing junction box / wooden block including connections etc. as required. | BI01010001010000000000000515BI0100001204 | 3 | Each |
92 | 69 | Supplying and fixing bakelite batten/angle holder including connections etc. as required:- | BI01010001010000000000000515BI0100001205 | 3 | Each |
93 | 70 | Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Exhaust Fan, Light duty, (Domestic) 300 mm sweep | BI01010001010000000000000515BI0100001206 | 1 | Each |
94 | 71 | SCHEDULE -D DISTRIBUTION SYSTEM Laying, jointing and testing of GMS tubes medium grades (to be levelled to grade) in trenches including fitting with tees,unions sockets testing & commissioning complete as per IPH specification within in all leads and lifts | BI01010001010000000000000515BI0100001207 | ||
95 | 71.01 | 25mm dia | BI01010001010000000000000515BI0100001208 | 7670 | Rmt |
96 | 71.02 | 32mm dia | BI01010001010000000000000515BI0100001209 | 5700 | Rmt |
97 | 71.03 | 40mm dia | BI01010001010000000000000515BI0100001210 | 5200 | Rmt |
98 | 71.04 | 50mm dia | BI01010001010000000000000515BI0100001211 | 6500 | Rmt |
99 | 71.05 | 65mm dia | BI01010001010000000000000515BI0100001212 | 10850 | Rmt |
100 | 71.06 | 80mm dia | BI01010001010000000000000515BI0100001213 | 9300 | Rmt |
101 | 72 | Providing and fixing peet valve of various dia including housing chamber complete.within al lleads and lifts | BI01010001010000000000000515BI0100001214 | ||
102 | 72.01 | 15mm | BI01010001010000000000000515BI0100001215 | 12 | Each |
103 | 72.02 | 20mm | BI01010001010000000000000515BI0100001216 | 12 | Each |
104 | 72.03 | 25mm | BI01010001010000000000000515BI0100001217 | 10 | Each |
105 | 72.04 | 32mm | BI01010001010000000000000515BI0100001218 | 12 | Each |
106 | 72.05 | 40mm | BI01010001010000000000000515BI0100001219 | 10 | Each |
107 | 72.06 | 50mm | BI01010001010000000000000515BI0100001220 | 8 | Each |
108 | 72.07 | 65mm | BI01010001010000000000000515BI0100001221 | 6 | Each |
109 | 72.08 | 80mm | BI01010001010000000000000515BI0100001222 | 6 | Each |
110 | 73 | Providing , laying, fixing, jointing and testing in trenches (ISO:3183) of following dia meters confirming to X- 70 (latest with upto date amendments) steel grade- A having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, provinding and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). | BI01010001010000000000000515BI0100001223 | ||
111 | 73.01 | Phase - 1st | BI01010001010000000000000515BI0100001224 | ||
112 | 73.02 | a) 80mm dia MSERW pipe X-70: Wall thickness 4.80 mm, flange table-38 from RD 0 to Rd 1000 (5%) | BI01010001010000000000000515BI0100001225 | 50 | Rmtr |
113 | 73.04 | a) 80mm dia MSERW pipe X-70: Wall thickness 4.80 mm, flange table-28 from RD 1000 to RD 2950 (5%) | BI01010001010000000000000515BI0100001226 | 97.5 | Rmtr |
114 | 74 | Providing Butt welding, laying and testing to levelled grades, IS marked Galvanised beveled ended of following dia mtr. / specifications confirming ISO:3183 ( with upto date amendments ) of steel grades X- 46 and X-42 jointing the pipes with butt welding at both and according to relevant BIS standards / approved specifications including manufacturing reducers/ tapers all short pieces , and bends as per site requirements and made from parent tubes ( to be measured and paid along with pipes ). Bends shall be manufactured in such a way that not more than 11-1/4 degree deflection is caused by a single cut and internal dia is not reduced including hydraulic testing to the entire satisfaction of Engineer-in -charge. The pipes and specials shall have in factory galvanized coating as per IS :4739 ( with latest amendments ) . The damaged portion of galvanization due to welding shall be provided with anticorrosive treatment by applying two coats of bituminous paint over priming coat as per AWWA specification C-203-1978 ( Earth work to be measured & paid for separately) | BI01010001010000000000000515BI0100001227 | ||
115 | 74.01 | Phase - 1st a) 80 mm dia MSERW pipe X-70 :Wall thickness 4.80 mm, From RD 0 to RD 2950 (95%) | BI01010001010000000000000515BI0100001228 | 2802.5 | Rmtr |
116 | 75 | SCHEDULE -E PUMPING MAHINERY Providing,laying jointing, installation testing and commissoning horizontal spindle, horizontal radial split casing/end suction (back out arrangment) single/double/multistage centrifugal pump or combination of pump in seris/parallel of recommended pumps such as Mather and Platt/KSB/Beacon/L&T/Kirloskar/Jyoti/all approved make as per BIS 1520-1980 with upto date amendments, read with IS 9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze impellers/priming funnels, casing ring and shaft sleeves of bronze,shaft of steel grade with cast iron casing coupled directly through a flexible coupling and common Ci/Cast steel base plateform ( base plate to be from the manufactturer of pumping unit only) to slip ring/screen protented drip proof induction motor.motors of standard make such as Kirloskar/BHEL/Compton/NGEF/GEC/Siemens/Jyoti and suitable for operation on 415+/-5% volts, 50cycles/second, 3 phase AC electric supply. The power of electric motor/motors should be designed +10% in excess of the maximum power required by the p[ump/pumps inthe operation rangeof (+) 10% and (-) 15% of duty point head. The motor.motors a per IS 325-1978 with uo to date amendments read with IS 900-1972. It should include cost of bearing nuts, bolts and painting etc. | BI01010001010000000000000515BI0100001229 | 4 | Set |
117 | 75.01 | Discharge: 2.10 LPS for each pump | BI01010001010000000000000515BI0100001230 | ||
118 | 75.02 | Static head head: 650.0 mtrs. | BI01010001010000000000000515BI0100001231 | ||
119 | 75.03 | Total Head :- 712.24 | BI01010001010000000000000515BI0100001232 | ||
120 | 75.04 | a) LWL in sump well: 1651.50 mtrs. | BI01010001010000000000000515BI0100001233 | ||
121 | 75.05 | b) Pump shaft level: 1651.00 mtrs. | BI01010001010000000000000515BI0100001234 | ||
122 | 75.06 | c) Level at discharge point: 2301.00 mtrs. | BI01010001010000000000000515BI0100001235 | ||
123 | 75.07 | d) Suction lift : +ve | BI01010001010000000000000515BI0100001236 | ||
124 | 75.08 | Rising main: a) Length 2950 mtrs 80mm dia | BI01010001010000000000000515BI0100001237 | ||
125 | 75.09 | Pumping hours: 8 | BI01010001010000000000000515BI0100001238 | ||
126 | 75.1 | Altitude of installation above MSL: 1651 mtrs. | BI01010001010000000000000515BI0100001239 | ||
127 | 75.11 | Characteristics of water: Clear cold water, turbidity up to 50 PPM | BI01010001010000000000000515BI0100001240 | ||
128 | 75.12 | Temprature : 25 degree centigrade. | BI01010001010000000000000515BI0100001241 | ||
129 | 76 | Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments, immediately after the power meter of the HPSEBL. | BI01010001010000000000000515BI0100001242 | 1 | Set |
130 | 77 | Providing MS sheet 16G steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.75 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n | BI01010001010000000000000515BI0100001243 | 1 | Each |
131 | 77.01 | a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS:2516-1985 with upto date ammendments\n | BI01010001010000000000000515BI0100001244 | 1 | Each |
132 | 77.02 | b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n | BI01010001010000000000000515BI0100001245 | 1 | Each |
133 | 77.03 | c) The voltage monitor relay of AE/MEI/L&T/Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482 (latest edition)\n | BI01010001010000000000000515BI0100001246 | 1 | Each |
134 | 77.04 | d) Providing digital VAF meter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n | BI01010001010000000000000515BI0100001247 | 1 | Each |
135 | 77.05 | g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n | BI01010001010000000000000515BI0100001248 | 2 | Set |
136 | 77.06 | h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n | BI01010001010000000000000515BI0100001249 | 4 | Set |
137 | 77.07 | i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n | BI01010001010000000000000515BI0100001250 | 4 | Set |
138 | 77.08 | j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n | BI01010001010000000000000515BI0100001251 | 4 | Set |
139 | 77.09 | k) Capacitor of Crompton/L&T/NGEP/Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n | BI01010001010000000000000515BI0100001252 | 4 | Each |
140 | 77.1 | l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n | BI01010001010000000000000515BI0100001253 | 4 | Each |
141 | 77.11 | m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n | BI01010001010000000000000515BI0100001254 | 4 | Each |
142 | 78 | Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Kartar make for the suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments\n | BI01010001010000000000000515BI0100001255 | 4 | Each |
143 | 79 | Providng double flanged cast steel sluice valves ASA-600 of leader/BHEL Kirlosker/Kilburn GLED/fourses make for delivery line of pump and capable of withstanding the normal seat pressure and as per API 600 with upto date ammdnements\n | BI01010001010000000000000515BI0100001256 | 4 | Each |
144 | 80 | Providing double flanged cast steel reflux valves class ASA-600 of Leader/BHEL/KILROSKER/Kartar/KILBURN/GLED/FOURSES make having bye pass arrangements on delivery line of pump and capable of withstanding normal seat pressure as per IS:1868 with upto date ammendments.\n | BI01010001010000000000000515BI0100001257 | 4 | Each |
145 | 81 | Providing double flanged cast steel reflux valves class ASA-600 of Leader/BHEL/KILROSKER/Kartar/KILBURN/GLED/FOURSES make and of 80mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per IS:1868 with upto date ammendments.\n | BI01010001010000000000000515BI0100001258 | 4 | Each |
146 | 82 | Providing 100mm dia circular dial digital analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n | BI01010001010000000000000515BI0100001259 | 4 | Each |
147 | 83 | Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n | BI01010001010000000000000515BI0100001260 | 2 | Each |
148 | 84 | Installation of all the items apparing at serial No.75 to 83 as per the systematic drawing \n | BI01010001010000000000000515BI0100001261 | 1 | Job |
149 | 85 | Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.95. The size of the various components to be as under:\n | BI01010001010000000000000515BI0100001262 | ||
150 | 85.01 | Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n | BI01010001010000000000000515BI0100001263 | 15 | Rmtr. |
151 | 85.02 | Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n | BI01010001010000000000000515BI0100001264 | 15 | Rmtr. |
152 | 85.03 | Common header :One dia higher then delivery of pump x80 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed\n | BI01010001010000000000000515BI0100001265 | 10 | Rmtr. |
153 | 86 | Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor\n | BI01010001010000000000000515BI0100001266 | ||
154 | 86.01 | (a) Motor side (From switch to starter and starter to motor) | BI01010001010000000000000515BI0100001267 | 10 | Mtr. |
155 | 86.02 | (b) Supply side (From Meter of HPSEB to bus bar and switch) | BI01010001010000000000000515BI0100001268 | 10 | Mtr. |
156 | 87 | Providing and fixing double loop earth with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.\n | BI01010001010000000000000515BI0100001269 | 1 | Job |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail