Ge 874/Ews-01/2020-21 Spl Repair To Bld No T-158 Of Inf Bde And External Water Supply At Baghbella And Replacement Of Ber Air Conditioners At Tangdhar Under Ge 874 Ews, TANGDHAR-Jammu And Kashmir

Military Engineer Services-MES has published Ge 874/Ews-01/2020-21 Spl Repair To Bld No T-158 Of Inf Bde And External Water Supply At Baghbella And Replacement Of Ber Air Conditioners At Tangdhar Under Ge 874 Ews. Submission Date for this Tender is 11-06-2020. Building Repair Tenders in TANGDHAR Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

24357234
Corrigendum : Ge 874/Ews-01/2020-21 Spl Repair To Bld No T-158 Of Inf Bde And External Water Supply At Baghbella And Replacement Of Ber Air Conditioners At Tangdhar Under Ge 874 Ews
National Competitive Bid
Indian
Jammu And Kashmir
TANGDHAR
11-06-2020

Tender Details

Ge 874/Ews-01/2020-21 Spl Repair To Bld No T-158 Of Inf Bde And External Water Supply At Baghbella And Replacement Of Ber Air Conditioners At Tangdhar Under Ge 874 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Jun-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-06-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 44000.0 /-
Tender Value
INR 22 Lakhs /-

BOQ Items

Name of Work: SPL REPAIR TO BLD NO T-158 OF INF BDE AND EXTERNAL WATER SUPPLY AT BAGHBELLA AND REPLACEMENT OF BER AIR CONDITIONERS AT TANGDHAR UNDER GE 874 EWS.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed. 4.38 Cum
2 2 Taking down cement plaster on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified. 37.6 Sqm
3 3 Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. 3.21 Cum
4 4 Walling of random rubble stone masonry uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified. 2.5 Cum
5 5 All as per ser Item No 4.00 above but except stone, complete all specified and directed 0.71 Cum
6 6 Dismantling of timber scantling 40sqcm and over in section unframed work,as in any position, complete all as specified. 5.6 Cum
7 7 Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, all as specified. 212 Sqm
8 8 2nd class soft wood as in scantling, clean sawn fixed in unframed work, complete all as specified and directed. 5.26 Cum
9 9 M&L 2nd class soft wood as in scantling, clean sawn fixed in unframed work (except timber), complete all as specified and directed. 0.34 Cum
10 10 Taking down chowkhats of frame exc 1.5 sqm and n. Exc 4 sqm each with shutter (without taking off shutters of the frame), complete all as specified. 5 Each
11 11 Taking down chowkats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.5Sqm each, complete all as specified. 8 Each
12 12 M&L 2nd class soft wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified. 0.19 Cum
13 13 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed. 10 Sqm
14 14 M&L 30mm thick 2nd class soft wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc (divided in square with sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete, all as specified. 8.64 Sqm
15 15 S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. 205 Sqm
16 16 Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified. 7 Sqm
17 17 100 mm Mild steel butt hinges, cast brass, bright polished and fixed type B-11,complete all as specified and directed. 15 Each
18 18 Aluminium anodised, barrel tower bolts of extruded section of size 200mm and fixed, complete all as specified and directed. 10 Each
19 19 Aluminium alloy, anodised, 250mm sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed. 5 Each
20 20 Aluminium alloy handles, cast type, anodised of size 150mm and fixed, complete all as specified and directed. 10 Each
21 21 M&L for 12mm thick cement plaster rendering in CM 1:6 on other than fair faces of stone masnory/brick or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified. 37.6 Sqm
22 22 M&L for Applying three coats of white wash including preparation of newly plastered surfaces of wall complete all as specified. 37.6 Sqm
23 23 M&L Non skid coloured ceramic tiles 7 - 8 mm thick area of each tile exceeding 0.18sqm but not exceeding 0.38sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over and including 15mm thick screed bed in CM (1:4) laid over and including 25mm thick PCC (1:2;4) type B0 using 12.5mm graded crushed stone aggregate, complete all as specified and directed. 91.21 Sqm
24 24 Sheet glass ordinary quality, 3mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and as directed. 8.64 Sqm
25 25 75 mm Butt hinges, heavy weight, cold rolled mild steel, and fixed, complete all as specified and directed. 32 Each
26 26 Aluminium anodised, barrel tower bolts of extruded section of size 125 mm and fixed, complete all as specified and directed. 16 Each
27 27 Aluminium alloy handles, cast type, anodised ISI marked of size 100mm and fixed, complete all as specified and directed. 16 Each
28 28 Two coat of synthetic enamel paint over a coat of pink primer on new wooden or plywood surface of any description, not otherwise described over 10 cm width or girth, incliding preparation of surfaces complete, all as specified. 193 Sqm
29 29 Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) any thickness including cover fillets all as specified & directed 266 Sqm
30 30 M&L Plain fillets, rectangular or triangular in section clean sawn, secured with nails or brads sectional area, exc 3 Sqcm & not exc 6 sqcm, second class soft wood complete all as specified. 275 RM
31 31 M&L 6mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face fixed with screws to timber frame work as in wall linning, all as specified directed. 175 Sqm
32 32 6mm thick plywood (05 No of Ply) grade BWR type BB fixed with nails to timber frame work as in ceiling, complete all as specified. 91 Sqm
33 33 Dismantling boarding of any description fixed in any position with nails, complete all as specified and directed. 82.72 Sqm
34 34 20mm thick ,second class soft wood boarding, planed one side, with butt joints and fixed with nails in facia, eaves boarding, complete, (except flooring and skirting) all as specified and directed. 7.52 Sqm
35 35 2nd class soft wood weather boarding clean sawn, plain, 20mm thick or feather edge 15mm to 20mm thick and fixed with 30mm laps complete all as specified. 75.2 Sqm
36 36 Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed. 52 Per\nPoint
37 37 Points wiring for one light point/fan point/socket controlled by one switch with 1.5 sqmm PVC FRLS insulted un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC FRLS insulted un-sheathed copper conductor single core multi stranded flexible cable as earth lead (using colour coding) in and including cable 1100 volts grade including casing and capping (ISI marked) for one light/fan point including 2nd class hard wood rectangular block open recessed cover with 3mm thick plastic laminated sheet cover including cutting chases to wall making good the distrubed surfaces to match with the existing specification complete all as specified. 40 Per \nPoint
38 38 Points wiring for one socket on same board of 5 Amp controlled by one switch with 1.5 sqmm PVC FRLS insulted un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC FRLS insulted un-sheathed copper conductor single core multi stranded flexible cable as earth lead (using colour coding) in and including cable 1100 volts grade including casing and capping (ISI marked) for one light/fan point including 2nd class hard wood rectangular block open recessed cover with 3mm thick plastic laminated sheet cover including cutting chases to wall making good the distrubed surfaces to match with the existing specification complete all as specified. 6 Per \nPoint
39 39 Point wiring for 6 pin socket outlet 15 Amps on the independent board controlled by one switch with 4 sqmm PVC FRLS insulted un-sheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC FRLS insulted un-sheathed copper conductor single core multi stranded flexible cable as earth lead (using colour coding) in and including cable 1100 volts grade including casing and capping (ISI marked) including 2nd class hard wood rectangular block open recessed cover with 3mm thick plastic laminated sheet cover including cutting chases to wall making good the distrubed surfaces to match with the existing specification complete all as specified. 6 Per \nPoint
40 40 S & F LED batton T-8 Endura liner NEO with tube rod with surface and wall mounted, extruded aluminium housing provided for efficient heat with polycarbonate diffuser and integrated electronic driver' 20 watts 4 fits Make Havells cat no- LUMILINEBS20WLED830SPCWH or equivalent Wipro/Bajaj/Philips/Syska as approved by Engr-in-charge, complete all as specified and directed. 17 Each
41 41 Switch piano flush button single pole, one way 6 amps complete all as specified and directed. 46 Each
42 42 S & F Switch Socket combination 6 in 1, 5 and 15 Amp flush type universal controlled by one switch (ISI Marked) complete all as specifed and directed. 6 Each
43 43 Socket outlet 2 in 1, 5 pin, 5A, flush type universal, all as specified and as directed. 18 Each
44 44 Ceiling rose, PVC/poly carbonate, isolated body three terminal complete all as specified and directed. 19 Each
45 45 Lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed. 8 Each
46 46 Supply only LED lamp energy saving 9W LED lamp 6500 K Make Suriya or equivalent in Crompton greaves, Bajaj 8 Each
47 47 S & F in replacement of Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs 9W alongwith complete accessories. complete all as specified and directed. Havells item descrition RUGBYNEONFT10WLED860SSYMTOPC or equivalent of make Bajaj/Crompton/Philips/C&S. 2 Each
48 48 MCB single pole & neutral 6 to 32 Amps 230 Volts'C' series, 10 KA, complete all as specified and directed. 1 Each
49 49 S&F MCB's single pole 240 volts 6 to 32Amps 10 KA 'C' series, all as specified and as directed by Engr -in-Charge. 10 Each
50 50 Electric bell Multi Music type 230 volts AC supply all as specified and directed by Engineer-in-Charge. 1 Each
51 51 Switch bell push flush type 5 Amp single pole one way (ISI marked) complete all as specified 1 Each
52 52 Sheet metal enclosures factory made, (Double door) for DBs, single pole and neutral, 240 volts, 12 ways with 200Amp rated busbar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, testing and commissioning, complete all as specified and directed. 1 Each
53 53 Supply laying jointing and testing LT XLPE and PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 2 core, including taking down old cable, complete all as specified 100 RM
54 54 Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation laying of pole stay assembly and laying of LT cable as in any type of soil and getting out, complete all as specified. 108 Cum
55 55 Returning, filling, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete all as specified and directed. 82 Cum
56 56 Sand cushioning to protection of underground cables, laid 8cm before laying and 15cm after laying of cable and punned to form an overall layer of 18cm thick complete all as specified and directed by the Engr-in-Charge. Note: Punned down thickness shall be considered for measurement. 6 Cum
57 57 Material and labour for kiln burnt Sub class 'B' bricks laid dry , flat , width wise along the length of cable in trenches after sand cushioning for protection of under ground cable complete all as specified and directed. 560 Each
58 58 Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI medium grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 as in earthig pit, CI pit cover 5.5mm thick common salt charcoal all as specified. 1 Each
59 59 Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point complete all as specified and directed. 26 Cum
60 60 Taking up or down steel tubing of 20mm bore pipe and connection fixed to walls, ceiling or laid in floor or trenches and including cleaning for refixing or removal to store complete all as specified and directed. 100 RM
61 61 Taking up or down steel tubing of 25mm bore pipe and connection fixed to walls, ceiling or laid in floor or trenches and including cleaning for refixing or removal to store complete all as specified and directed. 150 RM
62 62 Taking up or down steel tubing of 40/50mm bore pipe and connection fixed to walls, ceiling or laid in floor or trenches and including cleaning for refixing or removal to store complete all as specified and directed. 220 RM
63 63 20mm dia GI steel water tubing ,medium grade ISI marked ,laid in trenches with and incl all fittings such as bends, elbows, tees, short pieces, diminishing pieces, union etc complete all as specified. 100 RM
64 64 25mm dia GI steel water tubing ,medium grade ISI marked ,laid in trenches with and incl all fittings such as bends, elbows, tees, short pieces, diminishing pieces, union etc complete all as specified. 150 RM
65 65 40mm dia GI steel water tubing ,medium grade ISI marked ,laid in trenches with and incl all fittings such as bends, elbows, tees, short pieces, diminishing pieces, union etc complete all as specified. 100 RM
66 66 50mm dia GI steel water tubing ,medium grade ISI marked ,laid in trenches with and incl all fittings such as bends, elbows, tees, short pieces, diminishing pieces, union etc complete all as specified. 120 RM
67 67 20mm bore Gun metal, globe or gate valves (ISI Marked), with iron wheel head, screwed both ends for iron pipe, fixed in repair, complete all as specified and directed. 10 Each
68 68 25mm bore Gun metal, globe or gate valves (ISI Marked), with iron wheel head, screwed both ends for iron pipe, fixed in repair, complete all as specified and directed. 7 Each
69 69 40mm bore Gun metal, globe or gate valves (ISI Marked), with iron wheel head, screwed both ends for iron pipe, fixed in repair, complete all as specified and directed. 4 Each
70 70 50mm bore Gun metal, globe or gate valves (ISI Marked), with iron wheel head, screwed both ends for iron pipe, fixed in repair, complete all as specified and directed. 3 Each
71 71 Construction of valve pit brick masonary, internal size 90x90x90 cm (from top of PCC to bottom of cover) including excavation in any type of soil, returning, filling in around foundation, removal of surplus soil to a distance not exceeding 50m, PCC 1:4:8 type D-2 in foundation, half brick thick brick work in CM 1:4, 12mm thick plaster in CM 1:4 to internal surfaces and flush pointed externally as the work proceeds in the same mortar PCC coping 1:2:4 type B-0 using 12.5mm graded stone aggregate, pit cover of MS sheet 3mm thick, handle and 40x 6mm FI 230mm long with 25mm dia hole at other end locking arrangement, fixing arrangement and painting with synthetic enamel paint two coat over a coat of red oxide primer, complete all as specified and directed. 2 Each
72 72 Lagging to pipes 20 mm bore used in internal water supply or plumbing all round with 40 mm thick bonded mineral wool preformed 'SNAP ON' pipe sections of density 144Kg/Cum conforming to IS-9842 provided with chicken mesh wire netting 25 gauge, 20mm mesh and covered with 0.01mm aluminium foil, complete all as specified. 60 RM
73 73 Lagging to pipes 25mm bore used in internal water supply or plumbing all round with 40mm thick bonded mineral wool preformed 'SNAP ON' pipe sections of density 144Kg/Cum conforming to IS-9842 provided with chicken mesh wire netting 25 gauge, 20mm mesh and covered with 0.01mm aluminium foil complete all as specified and directed. 45 RM
74 74 Supply, installation, testing and commissioning (hot and cold, reverse cycle) hi wall split Air conditioner of capacity 2.0 Ton (of refrigeration) (including all drilling and fasteners and making good any disturbed surface, taking down the old BER split AC and depositing to the MES store Yard) complete with Tripple filter (plasmater catechin filter, silver ion filter, Anti Bacteria Filter) fitted with suitable Rotary compressor, with anti fungalfunction, for operation with Non CFC Regrigerant suitable for operation in ambient temperature of 0 to 46 degrees celcius and with star rating of 4 star or above, Make- Daikin, VOLTAS, LG or Blue Star, capble operation on 220-240 volts single phase 50 Hz AC supply (after stabiliser as mentioned below)including comprising of the following:- (a) Refrigerant Copper tubing (with mokey tamper proof suitable insulation covered with aluminium sheet) for suction and discharge connection between indoor and outdoor units of suitable sizes and lenths as required at site. (b) Electric connections between outdoor and indoor units, industrial socket connection for the AC, submain wiring, all with suitable sized electric copper cable as per manufacturer's instruction and engineer in charge's directions. (c) Remote assembly complete with suitable size and capacity of batteries (cells) compatible with the AC. (d). Stand and galvalum cover for outer unit (including installation and making good any distrubed surface). (e) Flexible Drain pipe of suitable size and length fixed to wall all as specified and directed by engineer in charge. (f) 2 Ton AC stabiliser, digital type of make voltas or vinitec capable of operation in electric input 130V to 300V and providing output of 230V with not more than 6 seconds initial delay with surge voltage protection. (g) RCBO/MCB of suitable capacity with industrial socket enclosed in steel enclosure as directed by engineer in charge. 2 Each Job
75 75 Supply, installation, testing and commissioning (hot and cold, reverse cycle) hi wall split Air conditioner of capacity 2.0 Ton (of refrigeration) (including all drilling and fasteners and making good any disturbed surface, taking down the old BER split AC and depositing to the MES store Yard) complete with Tripple filter (plasmater catechin filter, silver ion filter, Anti Bacteria Filter) fitted with suitable Twin Rotary compressor, with anti fungalfunction, for operation with Non CFC Regrigerant suitable for operation in ambient temperature of minus 15 to plus 46 degrees celcius, Make- Daikin Cat part no FTXF71TV16 or equivalent in, VOLTAS, LG or Blue Star, capble operation on 220-240 volts single phase 50 Hz AC supply (after stabiliser as mentioned below)including comprising of the following:- (a) Refrigerant Copper tubing (with mokey tamper proof suitable insulation covered with aluminium sheet) for suction and discharge connection between indoor and outdoor units of suitable sizes and lenths as required at site. (b) Electric connections between outdoor and indoor units, insdustrial socket connection for the AC, submain wiring, all with suitable sized electric copper cable as per manufacturer's instruction and engineer in charge's directions. (c) Remote assembly complete with suitable size and capacity of batteries (cells) compatible with the AC. (d). Stand and galvalum cover for outer unit (including installation and making good any distrubed surface). (e) Flexible Drain pipe of suitable size and length fixed to wall all as specified and directed by engineer in charge. (f) 2 Ton AC stabiliser, digital type of make voltas or vinitec capable of operation in electric input 90V to 300V and providing output of 230V with not more than 6 seconds initial delay with surge voltage protection. (g) RCBO/MCB of suitable capacity with industrial socket enclosed in steel enclosure as directed by engineer in charge. 3 Each Job