Addition/Alteration To Two Rooms Including Drawing Room With Attached Bathroom In Buliding No . Et-110 At Tamulpur And Other Sanctioned Works At Tamulpur And Hattigor Military Station Under Ge Rangia, TAMULPUR AND HATTIGOR-Assam

Military Engineer Services-MES has published Addition/Alteration To Two Rooms Including Drawing Room With Attached Bathroom In Buliding No . Et-110 At Tamulpur And Other Sanctioned Works At Tamulpur And Hattigor Military Station Under Ge Rangia. Submission Date for this Tender is 10-06-2020. Building Work Tenders in TAMULPUR AND HATTIGOR Assam. Bidders can get complete Tender details and download the document.




Tender Notice

24317709
Corrigendum : Addition/Alteration To Two Rooms Including Drawing Room With Attached Bathroom In Buliding No . Et-110 At Tamulpur And Other Sanctioned Works At Tamulpur And Hattigor Military Station Under Ge Rangia
Open Tender
Indian
Assam
TAMULPUR AND HATTIGOR
10-06-2020

Tender Details

Addition/Alteration To Two Rooms Including Drawing Room With Attached Bathroom In Buliding No . Et-110 At Tamulpur And Other Sanctioned Works At Tamulpur And Hattigor Military Station Under Ge Rangia

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-May-2020 OTHER CORRIGENDUM 1 Other 03-06-2020
2 03-Jun-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-06-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 96600.0 /-
Tender Value
INR 48.30 Lakhs /-

BOQ Items

Name of Work: ADDITION/ALTERATION TO TWO ROOMS INCLUDING DRAWING ROOM WITH ATTACHED BATHROOM IN BULIDING NO. ET-110 AT TAMULPUR AND OTHER SANCTIONED WORKS AT TAMULPUR AND HATTIGOR MILITARY STATION UNDER GE RANGIA
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Surface dressing not exc. 15 cm deep in soft/loose soil, complete all as per specified and as directed by Engineer-in-charge. 120 Sqm
2 2 M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation filing and mass concrete complete all as specified and as directed by Engineer-in-charge. 43.5 Cum
3 3 M&L for hardcore of guage not exc. 63mm deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface of broken stone or boulders, complete all as per specified and as directed by Engineer-in-charge. 103.9 Cum
4 4 M&L 75 mm thick PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in sub-base of flooring complete all as specified and as directed by Engineer-in-charge. 140 Sqm
5 5 S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of grade Fe 410-W (Gde- E- 250) quality- B complete all as per specified and as directed by Engineer-in-charge. 250 Kg
6 6 M&L 75 mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) in footpath / hardstanding / pavings / plinth protections, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. 642 Sqm
7 7 Demolition of brick work built in any cement mortar complete all as specified and as directed by Engineer-in-charge. 12 Cum
8 8 M&L for Brickwork with sub- class ‘B’ bricks in CM 1:6 straight or curved on plan exc. 6 m mean radius complete all as per specified and as directed by Engineer-in-charge. 80.1 Cum
9 9 M&L for brick work with sub-class `B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge. 150 Sqm
10 10 Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings etc. complete all as specified and as directed by Engineer-in-charge. 60 Sqm
11 11 S&F pre-painted gavalume aluminium zinc coating GI based corrugated or semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as per specified and as directed by Engineer-in-charge. 413 Sqm
12 12 S&F pre-painted gavalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as per specified and as directed by Engineer-in-charge. 66 Sqm
13 13 S&F MS steel work in tubular trusses including special shaped washers etc. Using ERW or induction butt welded tubes confirming to IS-1161-1979 graded St-240 complete all as specified and as directed by Engineer-in-charge. 530 Kg
14 14 M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description not other wise described of over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as per specified and as directed by Engineer-in-charge. 15 Sqm
15 15 Taking down chowkat/frame with shutters exc. 1.5 sqm but not exc. 4 sqm (without taking off shutters from frame) complete all as per specified and as directed by Engineer-in-charge. 7 Each
16 16 S&F second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as per specified and as directed by Engineer-in-charge. 0.2 Cum
17 17 S&F 35 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as per specified and as directed by Engineer-in-charge. 10.2 Sqm
18 18 S&F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., without sash bars, edges of framing plain, chamferesd or rounded, fitted with cut and mitred beads for securing glass etc., as specified in SSR Pt I Section 8, clause 8.24 (a) and as directed by Engineer-in-charge. 5.6 Sqm
19 19 S&F 300mm dia ordinary rat tail rod pattern springs of mild steel including roller and roller plate for skeletton door shutters complete all as per specified and as directed by Engineer-in-charge. 3 Each
20 20 S&F 300 mm aluminum anodised sliding door bolts, ISI marked, with hasp, staple (bolt type) complete with clamps bolt not less than 16mm dia and fixing clips of sheet, cast or extruded section and fixing bolts an sliding bolt of extruded section or cast aluminum alloy, complete all as per specified and as directed by Engineer-in-charge. 5 Each
21 21 S&F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as per specified and as directed by Engineer-in-charge. 16 Each
22 22 S&F stainless steel wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and as directed by Engineer-in-charge. 8 Sqm
23 23 S&F butt hinges 100 mm long medium weight, cold rolled mild steel complete all as per specified and as directed by Engineer-in-charge. 24 Each
24 24 S&F 150 mm long Aluminium handles, cast type, anodised complete all as specified and as directed by Engineer-in-charge. 16 Each
25 25 S&F solid PVC door frame of size 50x47mm made out of 5 mm single side prelam PVC sheet used instead of plain colour PVC sheet and edges will be painted to match with prelam sheet, reinforced with MS square tube complete all as specified and as directed by Engineer-in-charge. 10 RM
26 26 S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall bw covered with heat moulded plain colour PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and botom rail on either side & as gap insert for tip rail & bottom rails; Panelling of plain colour PVC sheet to be fitted in the MS frame weloded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and as directed by Engineer-in-charge. 2.8 Sqm
27 27 M&L for preparation of new or previously untreated steel or iron surfaces of any description not otherwise described over 10cm girth or width and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as per specified and as directed by Engineer-in-charge. 73 Sqm
28 28 S&F steel windows with side hung shutters including box type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded complete all as per specified and as directed by Engineer-in-charge. 8.4 Sqm
29 29 S&F steel ventilators with top hung shutter including hinges, steel peg stay, complete all as per specified and as directed by Engineer-in-charge. 4.8 Sqm
30 30 S&F 4 mm thick sheet glass, ordinary quality in squares not exceeding 0.5 Sqm in each pane fixed with cut & mitred beads complete all as specified and as directed by Engineer-in-charge. 8 Sqm
31 31 M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. 120 Sqm
32 32 M&L for 20 mm thick rendering in CM 1:4 in two layers of 10mm each using water proofing compound in top layer only including finishing the surface even and smooth (WPC shall be measured and paid seperately) complete all as specified and as directed by Engineer-in-charge. \n 110 Sqm
33 33 Supply only integral water proofing compound confirming to IS complete all as per specified and as directed by Engineer-in-charge. 22 Kg
34 34 M&L for preparing new plastered surface and applying two coats of distemper oil emulsion on wall surfaces over a coat of alkali resistant primer and wall putty complete all as specified and as directed by Engineer-in-charge. 100 sqm
35 35 M&L for preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls including one coat of primer complete all as specified and as directed by Engineer-in-charge. 110 sqm
36 36 M&L 40 mm thick PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in floor, finished even and smooth using extra cement complete all as specified and as directed by Engineer-in-charge. 20 Sqm
37 37 M&L Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 15 mm thick screed bed or bedding layers in CM 1:6, complete all as per specified and as directed by Engineer-in-charge. 75 Sqm
38 38 S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 15 mm thick screed bed or bedding layers in CM 1:6, complete all as per specified and as directed by Engineer-in-charge. 12 Sqm
39 39 M&L for Glazed ceramic tiles in vertical surface 350 x 250 x 7\nmm / 450 X 350 X 7mm thick, coloured etc. set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 10 mm thick screed bed or bedding layers in CM 1:3, complete all as per specified and as directed by Engineer-in-charge. 24 Sqm
40 40 Dismantling of wall and ceiling boards (Fibre, pulp, insulation etc) of any thickness, including cover fillets complete all as specified and as directed by Engineer-in-charge. 74 Sqm
41 41 M&L for 4mm thick Non-Asbestos fiber Cement E-board ceiling of size (595x595)mm fixed in GI frame (snapgrid) of standard section as per manufacturers instructions complete all as specified and as directed by Engineer-in-charge. 74 Sqm
42 42 M&L for cement concrete bed (1:3:6) type C-2 to drain pipe of dia.150mm including packing under and haunching against the sides of pipes after they are laid and tested etc. complete all as specified and as directed by Engineer-in-charge. 18 RM
43 43 M&L for 150 mm bore soil glazed stoneware drain pipes laid in trenches and jointed complete all as specified and as directed by Engineer-in-charge. 18 RM
44 44 M&L for RCC 1:2:4 type B1 (20 mm graded stone aggregate) nominal mix as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed by Engineer-in-charge. 5.25 Cum
45 45 M&L for RCC 1:2:4 type B1 (20 mm graded stone aggregate) nominal mix as in columns, pillars, piers, posts and struts etc complete all as specified and as directed by Engineer-in-charge. 5.5 Cum
46 46 M&L for RCC 1:2:4 type B-1 (20 mm graded stone aggregate) nominal mix as in slabs supported on walls in beams and columns in floors, roofs, landings, balconies, deck slabs etc complete all as specified and as directed by Engineer-in-charge. 0.6 Cum
47 47 M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed by Engineer-in-charge. 10 Sqm
48 48 M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed by Engineer-in-charge. 4 Sqm
49 49 M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed by Engineer-in-charge. 5 Sqm
50 50 M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape as required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-charge. 160 Kg
51 51 M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape as required and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as per specified and as directed by Engineer-in-charge. 50 Kg
52 52 S&F PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints laid in trenches or in floor complete all as per specified and as directed by Engineer-in-charge. 33 RM
53 53 S&F PVC (SWR) 110 mm bore bends complete all as per specified and as directed by Engineer-in-charge. 5 Each
54 54 S&F 75 mm PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as per specified and as directed by Engineer-in-charge. 2 Each
55 55 S&F 75 mm PVC (SWR) pipes double socketed, in any length with rubber ring joints laid in trenches or in floors complete all as per specified and as directed by Engineer-in-charge. 4 RM
56 56 S&F GI tube 15 mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and as directed by Engineer-in-charge. 10 RM
57 57 S&F GI tube 25 mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and as directed by Engineer-in-charge. 12 RM
58 58 S&F sink made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets, including waste pipe, waste coupling and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed by Engineer-in-charge. 1 Each
59 59 S&F 15 mm bore fancy type chromium plated bib tap, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as per specified and as directed by Engineer-in-charge. 4 Each
60 60 S&F 15mm dia PVC connection pipe with PTMT nuts of length 600mm complete all as specified and as directed by Engineer-in-charge. 4 Each
61 61 S&F PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe complete all as specified and as directed by Engineer-in-charge. 1 Each
62 62 S&F Vitreous China wash down water closet pan 580 x 440 mm (Pedestal pattern) white complete incl seat and cover, flush pipe incl all joints complete all as specified and as directed by Engineer-in-charge. 1 Each
63 63 S&F 15mm bore stop cock CP screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe complete all as specified and as directed by Engineer-in-charge. 4 Each
64 64 S&F 15mm bore stop cock fancy type, chromium plated with long shank and cup (concealed type) screwed both end for iron pipe complete all as specified and as directed by Engineer-in-charge. 4 Each
65 65 S&F chromium plated shower rose 125 mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-charge. 1 Each
66 66 S&F towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and as directed by Engineer-in-charge. 1 Each
67 67 S&F 1000 litre storage capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed by Engineer-in-charge. 1 Each
68 68 S&F 25 mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by Engineer-in-charge. 1 Each
69 69 S&F 25 mm bore gun metal globe or gate valve with iron wheet head screwed both ends for iron pipe etc. complete all as specified and as directed by Engineer-in-charge. 2 Each
70 70 S&F in repair 600mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed by Engineer-in-charge. 1 Each
71 71 S&F 15mm bore pillar tap, fancy type, cast copper alloy with capstin head CP screwed down high pressure with or without littered 'H' or 'C' with long screwed shank and fly nuts screwed for iron pipe complete all as per specified and as directed by Engineer-in-charge. 1 Each
72 72 S&F GI tube 20 mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and as directed by Engineer-in-charge. 13 RM
73 73 S&F for PVC (SWR) 110mm Junction (single T) equal or un equal provided with access door complete all as specified and as directed by Engineer-in-charge. 4 Each
74 74 S&F 110 mm bore PVC (SWR) vent cowl complete all as specified and as directed by Engineer-in-charge. 1 Each
75 75 S&F 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including PVC clamps with nut and bolts complete all as per specified and as directed by Engineer-in-charge. 5 RM
76 76 S&F PVC (SWR) 75 mm bore bends with access door complete all as per specified and as directed by Engineer-in-charge. 3 Each
77 77 S&F Vitreous China Ware Wash hand basin white, flat back of size 550 x 400 mm size (flat back or angle back type) including brackets, CP brass waste coupling 32mm and waste pipe 32 mm etc complete all as per specified and as directed by Engineer-in-charge. 1 Each
78 78 M&L for errection of two staging walls with double stable of standard size of height upto 10' all as SSR specifications as per drawing NO RNG/ TD/ 37 sheet NO 1/1 for PVC tank complete all as per specified and as directed by Engineer-in-charge. 1 Each job
79 79 M&L for construction of manholes with 150 mm dia bore for connecting new drains making good to pipe, rendering, benching, forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished as required, Drg No CESZ/TD/40 sheet No 56 complete all as per specified and as directed by Engineer-in-charge. 2 Each
80 80 M&L for construction of septic tanks, exc, in ordinary soil, foundation in PCC (1:2:4), brick work in CM (1:4), RCC (1:1.5:3) slab covers including RCC(1:1.5:3) precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame Vent shaft and sludge chambers etc., complete for 25 users as per drg. No. TD/SZ/504 1/1 complete all as per specified and as directed by Engineer-in-charge. 1 Each
81 81 M&L for providing precast cement concrete 1:2:4, type B0 (using 12.5mm graded stone aggregate) as in louvres and jallies, 35mm thick (measured solid), including all mouldings but excluding frame set in cement mortar 1:4 complete all as per specified and as directed by Engineer-in-charge. 72 Sqm
82 82 M&L precast Coloured cement concrete chequered tiles 300x300x25mm thick set jointed and pointed in with grey cement and pigment laid over and including 20mm thick screed bed in CM 1:6 in floorings, complete all as per specified and as directed by Engineer-in-charge. 90 Sqm
83 83 M&L for sand filling under floors or in foundations including watering and consolidation complete all as per specified and as directed by Engineer-in-charge. 16 Cum
84 84 M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 of 60 mm thickness of M-35 grade with grey cement and pigment including 20 mm thick screed bed in CM 1:6 in flooring, complete all as per specified and as directed by Engineer-in-charge. 520 Sqm
85 85 M&L for rendering 15 mm thick on fair faces of brick work or one side of lathing in cement mortar 1:4, surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. 244 Sqm
86 86 M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as per specified and as directed by Engineer-in-charge. 420 Sqm
87 87 S&F 40 mm dia stainless steel railing (Grade S-304) (thicknes 1.5mm) complete all as per specified and as directed by Engineer-in-charge. 52 RM
88 88 S&F 50 mm dia stainless steel railing (Grade S-304) (thicknes 1.5mm) complete all as per specified and as directed by Engineer-in-charge. 104 RM
89 89 S&F 32 mm dia stainless steel railing (Grade S-304) (thicknes 1.5mm) complete all as per specified and as directed by Engineer-in-charge. 52 RM
90 90 S&F 3mm thick Aluminium composite panel both side decorated side lap fixed with coach screw washers in roof wall etc. complete all as per specified and as directed by Engineer-in-charge. 20 Sqm
91 91 Excavating in post holes not exc 0.5 cum, in soft soil and getting out, returning, filling in and ramming earth in layers not exc. 25 cm, watering and removing surplus soil to a distance not exc. 50 m and making good surfaces complete all as per specified and as directed by Engineer-in-charge. 16 Each
92 92 M&L for PCC 1:3:6 type C-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as per specified and as directed by Engineer-in-charge. 2.9 Cum
93 93 S&F MS rolled sections as in framing work of angle iron, pipe as in vertical post fixed with cleat and connecting plate etc including necessary welding, drilling of grade Fe-410-W (Gde- E- 250) quality-A complete all as per specified and as directed by Engineer-in-charge. 700 Kg
94 94 S&F rolled MS angle iron framed work for roof trusses as in main and cross beams hip and jack rafter, purlins where common rafters and running rails and fixed with angle cleats or other connecting plates incl necessary welding, drilling complete all as per specified and as directed by Engineer-in-charge. 2000 Kg
95 95 M&L for earth filling under floor in layers not exceeding 25cm thick including ramming and watering complete all as per specified and as directed by Engineer-in-charge. 15 Cum
96 96 M&L 25mm thick plain cement concrete type B0, 1:2:4 (using 12.5 mm graded stone aggregate) as levelling course complete all as per specified and as directed by Engineer-in-charge. 120 Sqm
97 97 M&L for double charge vetrified out door tiles of size 600x600x10mm thick heavy duty of approved pattern/design laid on floor over 15mm thick in CM 1:4 screed bed, set and jointed in neat cement slurry and pointed with coloured cement to match of tiles etc complete all as per specified and as directed by Engineer-in-charge. 150 Sqm
98 98 M&L for rendering 10 mm thick on other than fair faces of brick work or other side of lathing in cement mortar 1:6, surface finished even and smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge. 70 Sqm
99 99 M&L for vitrified ceramic tiles 8-10 mm thick (square / rectangular), light shade, polished, area of each tile not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge. 32 Sqm
100 100 All as per serial item No. 99 above but on vertical surfaces such as skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 10 mm thick rendering in CM 1:3 complete all as per specified and as directed by Engineer-in-charge. 8 Sqm
101 101 Removing excavated soils exceeding 250 m but not exceeding 500 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as per specified and as directed by Engineer-in-charge. 1 Cum
102 102 M&L for TMT bars 5mm dia and over upto and incl 10mm dia in stirrups cut to length, bent to shape required including cranking bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as per specified and as directed by Engineer-in-charge. 80 Kg
103 103 M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated single core multi stranded copper conductor cable drawn into and incl PVC conduit of adequate width and length with all accessories and fittings like bends, elbow, crosses and GI modular box of suitable size/module, inner & front plate or combined cover plate for modular fittings etc like switches, sockets and fan regulator incl 1.5 sqmm size PVC insulated multistranded copper conductor cable as earth continuity conductor and connected to earth dolly for one light point controlled by one switch complete all as per specified and as directed by Engineer-in-charge. 14 per Point
104 104 All as per serial item no. 103 above but for one fan point controlled by one switch. 2 per Point
105 105 All as per serial item no. 103 above but for socket combination 5 Amps on independent board. 7 per Point
106 106 All as per serial item no. 103 above but for 5 amp socket on same board. 3 per Point
107 107 All as per serial item no. 103 above but with 4 sqmm (nominal area) cable with 4.00 sq mm size copper earth continuity conductor of green colour for 15 A socket outlet on independent boards . 5 per Point
108 108 S&F modular switch, single pole, 5 AMPs, 230 volts complete all as specified and as directed by Engineer-in-charge. 26 Each
109 109 S&F modular switch for 15/16 Amps complete all as specified and as directed by Engineer-in-charge. 5 Each
110 110 S&F modular socket outlet 3 Pin 5/6 AMPs shuttered socket with ISI marking complete all as specified and as directed by Engineer-in-charge. 10 Each
111 111 S&F modular socket outlet 3 Pin 6/16 A shuttered socket with ISI marking complete all as specified and as directed by Engineer-in-charge. 5 Each
112 112 S&F stepped type 4 Step Fan Regulator - 1 module electronic fan regulator on the existing laminated sheet (plate) etc. as reqd including necessary electric connection complete all as specified and as directed by Engineer-in-charge. 2 Each
113 113 S&F ceiling rose three terminals PVC/Polycarbonate, isolated body complete all as specified and as directed by Engineer-in-charge. 10 Each
114 114 S&F 34 watt reccess mounted luminaire with high brightness LED light fittings high efficiency glare free uniform light distribution 2x2 ft recess LED edge lit luminaire including driver, 230V, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge. 6 Each
115 115 S&F 10 Watt bulk head fitting, environmental friendly, ultra modern, energy saving, surface mounted, decorative back-lit LED luminaire comprising of high brightness LEDs, IP66, complete all as specified and as directed by Engineer-in-charge. 2 Each
116 116 S&F LED tube light fitting, Wall mounted, extruded head dissipation & integrated with crystal glass LED tube (double side connection) 22 W LED (4ft), 230V, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and as directed by Engineer-in-charge. 4 Each
117 117 Supply and Fixing 15 W building security light fittings suitable for new generation energy saving & environmental friendly long life LED street light made up of pressure die-cast aluminium housing with high efficient LED as lighting source and PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete all as specified and as directed by Engineer-in-charge.\nMake - Havells cat No. ENDURAPEARLSL15WLED757SASYTOPCMP or equivalent model of makes mentioned in the "LIST OF PRODUCTS FOR INCORPORATION IN THE WORK" of Particular Specification. 2 Each
118 118 S&F street light bracket made out of GI tubing 25 mm bore medium grade 1.00 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 50mm x 6mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for steel tubular pole including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.\n 2 Each
119 119 S&F single pole & neutral 8 way DB with double door complete all as specified and as directed by Engineer-in-charge. 1 Each
120 120 Supply and fix MCB SPN 240 Volts 40 Amps breaking capacity 10 KA rating complete all as specified and as directed by Engineer-in-charge. 1 Each
121 121 Supply and fix MCB SP 240 Volts 6 to 32 Amps breaking capacity 10 KA rating complete all as specified and as directed by Engineer-in-charge. 6 Each
122 122 Excavating in trenches, not exc. 1.5 m wide and not exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 sqm on plan and not exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge. 59.66 Cum
123 123 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as per specified and as directed by Engineer-in-charge. 29.66 Cum
124 124 Removing excavated material (soil) not exc. 50m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as per specified and as directed by Engineer-in-charge. 29 Each
125 125 M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed by Engineer-in-charge.\nNote - Measurement and payment shall be done only for punned thickness. 4.8 Cum
126 126 Supply & Laying of Sub-Class 'B' Bricks, well burnt, laid breadth wise along the length of cable laid in trenches laid for UG cable protection, complete all as per specified and as directed by Engineer-in-charge. 0.48 Per 1000 Nos.
127 127 Supply, laying and testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 core complete all as specified and as directed by Engineer-in-charge. 75 RM
128 128 Supply & laying of GI pipe 25 mm bore light grade for under ground cable protection complete all as per specified and as directed by Engineer-in-charge. 6 RM
129 129 Supply and fix LED tube light fittings with regal batten for LED, wall mounted, extruded head dissipation & integrated with crystal gladd LED tube (single side connection) 22 W LED 4', 230 V complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to tube light fitting complete all as specified and as directed by Engineer-in-charge. 6 Each
130 130 S&F ceiling fan hook made out of MS flat 50 X 6 mm thick suitable for hanging of ceiling fan including nuts, bolts and washer with 12 mm dia round bar hook after taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge. 2 Each
131 131 Supply and fixing ceiling fan having sweep size of 1200 mm, 240 volt, BEE 5 star, 3 blades with inetrnal pre-wired, complete all as per specified and as directed by Engineer-in-charge. 2 Each
132 132 S&F electric water heater, storage type, metal body, 25 litres capacity, BEE 5 star rated, fixed by using min 2 Nos 75 mm long MS fasteners, nuts and washers and making all necessary electric connection complete all as specified and as directed by Engineer-in-charge. 1 Each
133 133 Supply and fix metal body exhaust fan of 300 mm Sweep, Single phase, 230 Volt, 50 HZ, Heavy duty copper wound motor, double ball bearing, 900 RPM, complete all as specified and as directed by Engineer-in-charge. 2 Each
134 134 M&L for cutting/chasing in brick wall for exhaust fan of 300 mm dia for air outlet and repairing/making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. 2 Each Job
135 135 M&L for earthing with Galvanised Iron Earth Plate Electrode 600X600X6mm size buried directly in Ground vertically at a depth not less than 2.25 METRE below Ground Level with the Top Edge of Earth Plate at a depth not less than 1.50 METRE below Ground Level connected to Galvinased earth lead wire 4.0mm dia by means of Bolts, Nuts, Check Nuts and Washers of Galvanised Steel, Earth Plate Electrode surrounded by a packed thickness of Char Coal or Coke Dust mixed with common Salt in alternate layers not exc. 150mm thick including Galvanised Iron Pipe 25mm Bore (dia) Light Grade, upto test points above the Floor Level of the Building situated including PCC Pit in Cement Concrete 1:3:6 (20mm Graded Stone Agg-regate) and RCC Cover of size 540X540X50 mm in RCC 1:2:4 (20mm Graded Stone Aggregate) einforced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways complete all as specified and as directed by Engineer-in-charge.\nNOTE:- \n(I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. \n(ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. \n(iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow, etc. shall be deemed included in the unit rate. 1 Each
136 136 Supply, errection and testing of solar power traffic blinker of yellow color mounted on GI pipe minimum of 50 mm dia and height 2.0 m from FFL with following specification including necessary foundation complete all as specified and as directed by Engineer-in-charge. \nSpecification:-\nBattery: 24V / 7Ah, Lighting Type: LED, working mode: 24 Hr/Light, Sensor Control, Solar Panel : 10 W, Size: Dia-300 mm, Sheet Material: Polycarbonate, Flashing Frequency: 50 Times/minute\nMake : H2 Safety India Private Limited Model Number: H2SB300. \nNote:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ. 8 Each