Military Engineer Services-MES has published Repair And Maintenance To Summer Appliances Such As Air Conditions , Water Coolers , Desert Coolers , Refrigerators , Ac Plant And Voltage Stabilizers Etc At Mil Stn Abohar. Submission Date for this Tender is 29-05-2020. Voltage Stabiliser Tenders in Abohar Mil Stn Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 30-Apr-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 07-05-2020 |
2 | 08-May-2020 | Corrigendum No 2 | Date | 14-05-2020 |
3 | 16-May-2020 | Corrigendum No 3 | Date | 19-05-2020 |
4 | 20-May-2020 | Corrigendum No 4 | Date | 29-05-2020 |
Name of Work: Repair and maint to summer appliances such as Air Conditions, Water Coolers, Desert Coolers, Refrigerators, AC Plant and Voltage Stabilizers etc at Mil Stn Abohar | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | REPAIR TO WATER COOLER | |||
2 | 2 | Disconnecting, dismantling (taking out) existing burnt / unserviceable sealed unit compressor of water cooler of capacity 40/80 litres and provision of new sealed unit compressor from original manufacturer /authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) including transportation from site to workshop for replacement and back, fixing, commissioning, testing including one year warranty period and gas charging etc complete all as specified and as directed by Engineer-in-charge. | 8 | Each Job | |
3 | 3 | All as per Srl item No. 02 (here in before) but capacity 60/120 litres | 10 | Each Job | |
4 | 4 | All as per Srl item No. 02 (here in before) but capacity 80/150 litres | 5 | Each Job | |
5 | 5 | Cleaning the unit with CO2 Gas and recharging of gas complete of water cooler of capacity upto 40/80 litres complete all as specified and as directed by Engineer-in-Charge.\nNote :- The type and specification of gas shall be as per manufacturers instructions of equipment and as directed by Engineer-in-Charge. | 10 | Each Job | |
6 | 6 | All as per Srl item No. 05 (here-in-before) but water cooler capacity 60/120 ltrs | 10 | Each Job | |
7 | 7 | S&F in replacement Starting relay complete of water coolers of capacity 40/40, 40/80, 60/120, 120/150 litres etc complete all as specified and as directed by Engineer-in-charge.\nMake : Renutrol/Indofoss | 15 | Each | |
8 | 8 | S&F in replacement thermostat switch including plate and screw suitable for water cooler of storage capacity upto 150 litres and making necessary electric connection complete all as specified and as directed by Engineer-in-charge. \nMake : Indofoss / Denfoss | 15 | Each | |
9 | 9 | S&F as in replacement electric wiring kit suitable for water cooler of any make/ capacity with all connections complete all as specified and as directed by Engineer-in-charge. | 20 | Each | |
10 | 10 | S&F in replacement self closing type cast copper alloy, chromium plated water tap (ISI marked) suitable for water cooler screwed and making necessary connection etc complete all as specified and as directed by Engineer-in-charge. | 30 | Each | |
11 | 11 | S&F in replacement ball brass valve (ISI marked) 15mm bore, high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule etc complete all as specified and as directed by Engineer-in-charge. | 12 | Each | |
12 | 12 | S&F in replacement running capacitor 16 mfd etc complete all as specified and as directed by Engineer-in-charge. \nMake : Keil/Sharda/Tibcon | 20 | Each | |
13 | 13 | S&F in replacement Starting capacitor 80/100 mfd etc complete all as specified and as directed by Engineer-in-charge. \nMake : Keil/Sharda/Tibcon | 20 | Each | |
14 | 14 | S&F in replacement Running capacitor 25/36 mfd etc complete all as specified and as directed by Engineer-in-charge. \nMake : Keil/Sharda/Tibcon | 20 | Each | |
15 | 15 | S&F in replacement cooling coil suitable for water cooler of capacity 60/120 litres complete all as specified and as directed by Engineer-in-charge. \nMake : USHA / VOLTAS/ SRI RAM | 4 | Each | |
16 | 16 | S&F in replacement new blower motor for water cooler of capacity 80/150 litres etc complete all as specified and as directed by Engineer-in-charge. Make : USHA / VOLTAS/ KHAITAN | 3 | Each | |
17 | 17 | S&F in replacement new blower motor for water cooler of capacity 60/120 litres etc complete all as specified and as directed by Engineer-in-charge. Make : USHA / VOLTAS/ KHAITAN | 8 | Each | |
18 | 18 | S&F in replacement new blower motor for water cooler of capacity 40/80 litres etc complete all as specified and as directed by Engineer-in-charge. Make : USHA / VOLTAS/ KHAITAN | 8 | Each | |
19 | 19 | S&F as in replacement stainless steel tray 1mm thick, for waste water for water cooler of capacity 40/80 litres etc complete all as specified and as directed by Engineer-in-charge. | 4 | Each | |
20 | 20 | Material & labour for spray painting the water cooler of storage capacity upto 80 litre with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge. | 12 | Each Job | |
21 | 21 | Material & labour for spray painting the water cooler of storage capacity upto 120 litre with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge. | 10 | Each Job | |
22 | 22 | REPAIRS TO REFRIGERATORS | |||
23 | 23 | Disconnecting, dismantling (Taking out) existing burnt /unserviceable sealed unit compressor of refrigerator of capacity 165 litres and provision of new sealed unit compressor from manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) and fixing, commissioning and testing including one year guarantee and necessary gas charging including transportations to work shop and back etc complete all as specified and as directed by Engineer-in-Charge. | 9 | Each Job | |
24 | 24 | All as per Srl item No. 23 (here-in-before) but 310 litres capacity | 10 | Each Job | |
25 | 25 | S&F in replacement thermostat switch suitable for 310/165 ltrs refrigerator complete all as specified and as directed by Engineer-in-Charge.\nMake : Danfoss/Indofoss | 15 | Each | |
26 | 26 | S&F in replacement starting relay 1/6 HP to 1/10 HP suitable for refrigerator of capacity 165/286/310 litres including thimbles and screws etc complete all as specified and as directed by Engineer-in-charge. Make : Renutrol/Indofoss | 20 | Each | |
27 | 27 | S&F in replacement over load protector suitable for refrigerator of capacity upto 310 ltr etc complete all as specified and as directed by Engineer-in-charge.\nMake : SRI RAM / Renutrol | 15 | Each | |
28 | 28 | S&F in replacement cooling coil suitable for refrigerator of capacity upto 310 litres complete all as specified and as directed by Engineer-in-charge. \nMake : GODREJ / VOLTAS/ LG / SAMSUNG | 4 | Each | |
29 | 29 | S&F in replacement Vegetable tray suitable for refrigerator of capacity upto 165 ltr complete all as specified and as directed by Engineer-in-charge. | 8 | Each\n | |
30 | 30 | S&F in replacement Vegetable tray suitable for refrigerator of capacity upto 286/300 ltr complete all as specified and as directed by Engineer-in-charge. | 8 | Each\n | |
31 | 31 | S&F in replacement Ice chamber (freezer box) including freezer cover suitable for refrigerator of capacity upto 165 ltr complete all as specified and as directed by Engineer-in-charge. | 8 | Each\n | |
32 | 32 | S&F in replacement Ice chamber (freezer box) including freezer cover suitable for refrigerator of capacity upto 286/300 ltr complete all as specified and as directed by Engineer-in-charge. | 6 | Each\n | |
33 | 33 | Cleaning the unit with CO2 Gas and recharging of gas complete of refrigeator capacity 165/200 ltrs complete all as specified and as directed by Engineer-in-Charge.\nNote :- The type and specification of gas shall be as per manufacturers instructions of equipment and as directed by Engineer-in-Charge. | 15 | Each Job | |
34 | 34 | Cleaning the unit with CO2 Gas and recharging of gas complete of refrigeator capacity 286/300/310 ltrs complete all as specified and as directed by Engineer-in-Charge.\nNote :- The type and specification of gas shall be as per manufacturers instructions of equipment and as directed by Engineer-in-Charge. | 15 | Each Job | |
35 | 35 | Material & labour for spray painting the refrigerator of capacity 165/200 litres with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge. | 10 | Each Job | |
36 | 36 | Material & labour for spray painting the refrigerator of capacity 310 litres with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge. | 10 | Each Job | |
37 | 37 | REPAIR TO WINDOW / SPLIT TYPE AIR CONDITIONER | |||
38 | 38 | Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from the AC and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year with relay terminal box suitable for 1.5 ton capacity window type air conditioner including necessary gas charging, transportation to workshop & back complete all as specified and as directed by Engineer-in-charge. | 5 | Each Job | |
39 | 39 | Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from the AC and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year with relay terminal box suitable for 2 ton capacity window type air conditioner including necessary gas charging, transportation to workshop & back complete all as specified and as directed by Engineer-in-charge. | 5 | Each Job | |
40 | 40 | Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from the AC and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year with relay terminal box suitable for 1.5 ton capacity split type air conditioner including necessary gas charging, transportation to workshop & back complete all as specified and as directed by Engineer-in-charge. | 10 | Each Job | |
41 | 41 | Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from the AC and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year with relay terminal box suitable for 2 ton capacity Split type air conditioner including necessary gas charging, transportation to workshop & back complete all as specified and as directed by Engineer-in-charge. | 5 | Each Job | |
42 | 42 | S&F in replacement blower fan motor, single phase, 230 volt with fan assembly suitable for 1.5 ton capacity AC complete all as specified and as directed by Engineer-in-charge. \nMake: Khaitan / VOLTAS / USHA | 5 | Each | |
43 | 43 | S&F in replacement blower fan motor, single phase, 230 volt with fan assembly suitable for 2 ton capacity AC complete all as specified and as directed by Engineer-in-charge. \nMake: Khaitan / VOLTAS / USHA | 3 | Each | |
44 | 44 | S&F in replacement knob with screw for AC including making necessary connections complete (as per sample) all as specified and as directed by Engineer-in-charge. | 6 | Each | |
45 | 45 | S&F in replacement running capacitor 36 mfd including making necessary connections and testing complete all as specified and as directed by Engineer-in-charge.\nMake : Usha / Unistar / BHEL / Ramco | 15 | Each | |
46 | 46 | S&F in replacement thermostat switch with plate and screws suitable for window type air conditioners upto 1.5 ton capacity including making necessary connections and testing complete all as specified and as directed by Engineer-in-charge. Make : Renutrol/ Indofoss | 10 | Each | |
47 | 47 | S&F in replacement over load protector suitable for 1.5 ton capacity window type air conditioner complete all as specified and as directed by Engineer-in-charge.\nMake : SRI RAM / Renutrol / Indofoss | 10 | Each | |
48 | 48 | S&F in replacement over load protector suitable for 1.5 ton capacity split type air conditioner complete all as specified and as directed by Engineer-in-charge.\nMake : SRI RAM / Renutrol / Indofoss | 10 | Each | |
49 | 49 | S&F in replacement starting relay suitable for Air Conditioner 1.5/2 ton capacity complete all as specified and directed by Engineer-in-Charge. | 15 | Each | |
50 | 50 | S&F in replacement selector switch 3 speed with all connections complete all as specified and as directed by Engineer-in-charge. | 12 | Each | |
51 | 51 | S&F as in replacement electric wiring kit suitable for 1.5/2 ton capacity window/ split type air conditioner with all connections complete all as specified and as directed by Engineer-in-charge. | 10 | Each | |
52 | 52 | S&F in replacement front grill (as per sample kept in GE’s Office) of AC capacity 1.5 /2 ton complete all as specified and as directed by Engineer-in-charge. | 6 | Each | |
53 | 53 | Cleaning the gas system with CO2 Gas and gas charging complete of window/ split type AC all as specified and as directed by Engineer-in-Charge.\nNote :- The type and specificatin of gas shall be as per manufacturers instructions of equipment and as directed by Engieer-in-Charge. | 10 | Each Job | |
54 | 54 | REPAIR TO DESERT COOLERS | |||
55 | 55 | Dismantling all the parts of the desert cooler, taking down desert cooler Motor Kit of cap upto 4000 cum per hour, supply & fixing new desert cooler body made out of GI sheet of 18 gauge duly fitted with 2" thick wood wool pads including one front grill fitted with one piano type 6A switch, three speed selector switch of existing make with all arrangements of inlet pipe for pouring water and wash out valve (hole plugged with nut bolt and washer) for draining out dirty/contaminated water and washing etc complete all as specified and as directed by Engineer-in-charge. | 50 | Each Job | |
56 | 56 | S&F in replacement vertical pump (tullu pump) for desert cooler including making necessary connections complete all as specified and as directed by Engineer-in-charge. \nMake: Air King / Khaitan / Bajaj | 200 | Each | |
57 | 57 | S&F in replacement fan motor 400mm sweep including blades and brackets of desert cooler complete all as specified and as directed by Engineer-in-charge.\nMake: Cool Home / KHAITAN / Crompton / Bajaj | 50 | Each | |
58 | 58 | S&F in replacement fan motor 450mm sweep including blades and brackets of desert cooler complete all as specified and as directed by Engineer-in-charge.\nMake: Cool Home / KHAITAN / Crompton / Bajaj | 50 | Each | |
59 | 59 | S&F in replacement cooling pad (set of three) of desert cooler (as per sample kept in GE’s Office) of any size complete all as specified and as directed by Engineer-in-charge. | 200 | Each Set of three | |
60 | 60 | S&F in replacement PVC white pipe of size 15 mm bore as approved complete all as specified and as directed by Engineer-in-charge. | 300 | RM | |
61 | 61 | S&F in replacement of PVC insulated unarmored copper cable of size 3 Core, 40/0.0076 complete all as specified and as directed by Engineer-in-charge. Make : Plaza/Finolex/Paragon | 450 | RM | |
62 | 62 | S&F in replacement running capacitor 4 Mfd oil filled including making necessary connections and testing complete all as specified and as directed by Engineer-in-charge. \nMake: Usha / Unistar / Tibcon | 100 | Each | |
63 | 63 | Material & labour for spray painting to desert cooler with one coat of synthetic enameled anti corrosive paint using spray machine including preparation of surfaces and writing MES / SM No. with black paint on inner side of water tank etc complete all as specified and as directed by Engineer-in-charge. | 150 | Each Job | |
64 | 64 | S & F in replacement plug top, 6 Amp, 3 Pin, ISI marked complete all as specified and directed by Engineer-in-Charge. | 100 | Each | |
65 | 65 | REPAIR TO DEEP FREEZER | |||
66 | 66 | Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from Deep freezer of capacity 305/ 405 litres capacity and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year including necessary fixing, commissioning, testing and gas charging, transportation to workshop & back complete all as specified and as directed by Engineer-in-charge. | 3 | Each Job | |
67 | 67 | Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from Deep freezer of capacity 200 litres capacity and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year including necessary fixing, commissioning, testing and gas charging, transportation to workshop & back complete all as specified and as directed by Engineer-in-charge. | 3 | Each Job | |
68 | 68 | S&F in replacement Starting relay complete of water coolers of capacity 40/40, 40/80, 60/120, 120/150 litres etc complete all as specified and as directed by Engineer-in-charge.\nMake : Renutrol/Indofoss | 15 | Each | |
69 | 69 | S&F in replacement thermostat switch including plate and screw suitable for water cooler of storage capacity upto 150 litres and making necessary electric connection complete all as specified and as directed by Engineer-in-charge. \nMake : Indofoss / Denfoss | 15 | Each | |
70 | 70 | S&F as in replacement electric wiring kit suitable for water cooler of any make/ capacity with all connections complete all as specified and as directed by Engineer-in-charge. | 20 | Each | |
71 | 71 | S&F in replacement self closing type cast copper alloy, chromium plated water tap (ISI marked) suitable for water cooler screwed and making necessary connection etc complete all as specified and as directed by Engineer-in-charge. | 30 | Each | |
72 | 72 | S&F in replacement ball brass valve (ISI marked) 15mm bore, high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule etc complete all as specified and as directed by Engineer-in-charge. | 20 | Each | |
73 | 73 | S&F in replacement running capacitor 16 mfd etc complete all as specified and as directed by Engineer-in-charge. \nMake : Keil/Sharda/Tibcon | 20 | Each | |
74 | 74 | S&F in replacement Starting capacitor 80/100 mfd etc complete all as specified and as directed by Engineer-in-charge. \nMake : Keil/Sharda/Tibcon | 20 | Each | |
75 | 75 | S&F in replacement new blower motor for water cooler of capacity 80/150 litres etc complete all as specified and as directed by Engineer-in-charge. Make : USHA / VOLTAS/ KHAITAN | 5 | Each | |
76 | 76 | REPAIR TO VOLTAGE STABILIZERS | |||
77 | 77 | Dismantling voltage stabilizer of capacity 1 KVA to 6 KVA single phase 240 volt AC of any make and any Size for inspection, necessary repair and replacement of worn out/defective spare parts, reassembling, connecting up, testing etc complete all as directed(Necessary spare parts required for replacement shall be measured and paid for separately as supply only) | 25 | Each Job | |
78 | 78 | Supply only transformer suitable for voltage stabilizer of capacity 3 KVA of existing make and size complete all as specified and as directed | 10 | Each | |
79 | 79 | All as per Srl item No 78 here-in-before but capacity 4 KVA | 5 | Each | |
80 | 80 | All as per Srl Item No 78 here-in-before but capacity 5 KVA | 3 | Each | |
81 | 81 | All as per Srl Item No 78 here-in-before but capacity 6 KVA | 3 | Each | |
82 | 82 | Supply only circuit diagram plate suitable for voltage stabilizer of capacity upto 3 KVA of existing make and size complete all as specified and as directed | 15 | Each | |
83 | 83 | Supply only volt meter capacity 0-300 volt AC for stabilizer 3 KVA to 5 KVA complete all as specified and as directed | 6 | Each | |
84 | 84 | Supply only out put terminal plate as per existing size and all as directed | 10 | Each | |
85 | 85 | Repair/Maint of Ceiling fan & Exhaust fans | |||
86 | 86 | Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan,cutting the unserviceable winding of starter, rotor and taking out ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling and painting of ceiling fan by scraping/removing old spray paint with brush/emery paper and spray painting with two coat of synthetic enamelled paint complete ceiling fan fixing only old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. \n(Note :- 1. Ball bearing and Gun metal bush are measured and paid separately as supply only rates and minor spares like condensor, rubber bush shackle,holder deemed to beinclude in quoted rates).\n2. Repair/Rewinding of fan shall be carried out in MES yard to bring adequate winding machine,tools & plants and necessary motor winder at site as directed. | 730 | EACH JOB | |
87 | 87 | All as per Item No.86 here-in-before but exhaust fan of size 220/250/300/380/450 mm sweep. | 300 | EACH JOB | |
88 | 88 | All as per Item No.86 here-in-before but pedestal/Air circulator fan of size 400/450 mm sweep. | 10 | EACH JOB | |
89 | 89 | Taking down ceiling fan of 1200/1400 mm sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, servicing/overhauling and replacement of bush, bearing, condenser and including painting of ceiling fan by scraping/removing old spray paint with brush/emery paper and spray painting with two coat of synthetic enamelled paint complete all as specified and directed and marking MES number ass as directed by Engr-in-Charge. (Note :1. Bush, ball bearing are measured and paid separately as supply only rates and minor spares like condensor, rubber bush shackle,holder deemed to be include in quoted rates )\n2. Repair/Servicing of fan shall be carried out in MES yard to bring adequate winding machine,tools & plants and necessary motor winder at site as directed. | 400 | EACH JOB | |
90 | 90 | All as per item No 89 here in before but exhuast fan 220/250/300/380/450 mm sweep complete all as specified and directed and marking MES number ass as directed by Engr-in-Charge | 110 | EACH JOB | |
91 | 91 | Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, including filling the cavities with filler material and painting of ceiling fan by scraping/removing old spray paint with brush/emery paper and spray painting with two coat of synthetic enamelled paint complete all as specified and directed and marking MES number ass as directed by Engr-in-Charge.\nNote: 1. painting of fan shall be carried out in MES yard/given site to bring adequate winding machine,tools & plants and necessary motor winder at site as directed. | 460 | EACH JOB | |
92 | 92 | All as per Item No.91 here-in-before but exhaust fan of size 220/250/300/380/450 mm sweep. | 100 | EACH JOB | |
93 | 93 | All as per Item No. 91 here-in-before but pedestal/Air circulator fan of size 400/450 mm sweep. | 10 | EACH JOB | |
94 | 94 | Supply only ball bearing number of 6201/6202/6203/6204 as required complete all as specified and directed. (Make : SKF/NBC). | 1150 | EACH | |
95 | 95 | Supply only gun metal bush as per existing specification and make as per sample and confirming to ISI complete all as specified and directed. | 650 | EACH | |
96 | 96 | S&F for Condenser 2/2.5/3.15 MFD as per existing capacity and make as per sample and confirming to ISI complete all as specified and directed. \n (Make : Universal/Standard/Jyoti/Usha) | 550 | EACH | |
97 | 97 | S&F for PVC holder for condenser housing as per existing capacity and make as per sample and confirming to ISI complete all as specified and directed. | 60 | EACH | |
98 | 98 | S&F for rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200mm/1400mm sweep. | 60 | EACH | |
99 | 99 | S&F for twin core twisted copper flexible wire/cable of size 23/0.0076 complete all as specified and directed (Note: 0.8 mtr wire shall be used for one connection). (Make : Finolex/Nicco/KDK/KEI/Havells/HPL) | 80 | EACH JOB | |
100 | 100 | Supply only canopy top/bottom suitable for 20 mm dia ceiling fan rod suitable matching color as exising complete all as specified and directed | 30 | Each | |
101 | 101 | Supply only down rod 300 mm long of size 20 mm dia for ceiling fan complete all as specified and directed. | 30 | Each | |
102 | 102 | Supply only ceiling fan blades suitable for 1200/1400 mm sweep suitable for exising make & type as per sample complete all as specified and directed. | 30 | Set of three | |
103 | 103 | Supply only Exhasust fan blades suitable for 1200/1400 mm sweep suitable for exising make & type as per sample complete all as specified and directed. | 20 | Set of three | |
104 | 104 | Supply only exhaust fan canopy suitable size as per exising size of fans 220/250/300/380/450 mm suitable to matching color complete all as specified and directed | 10 | Set | |
105 | 105 | Supply only exhaust fan Louvers GI/MS/PVC suitable to size as per exising fans 220/250/300/380/450 mm complete all as specified and directed | 75 | Each | |
106 | 106 | Supply only fan regulator electronic (socket) type, single phase, 230Volt complete all as specified and directed Make: Anchor/Cona and equivalent make | 40 | Each | |
107 | 107 | Material and labour for making hole of size 220/250/300/380/450 mm round/Square as required for exhaust fan vent to using suitable tools without disturbing other surface and make good with cement plaster and exising color white wash/distemper/putty as existing color and surface including grouting bolts, nuts into wall for fixing exhaust fan complete all as specified and directed. | 30 | EACH Job |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail