Repair/Maintenance Of Electrical Appliances At Sub Stations Including Replacement Of Capacitor Control Switch , Street Light With Led Fittings , Earthing Pits Etc At Certain Otm Accn And Residential Area At Af Stn Rajokri Of Ge ( Af ) Gu Repair/Maint, GE (AF) Gurgaon-Haryana

Military Engineer Services-MES has published Repair/Maintenance Of Electrical Appliances At Sub Stations Including Replacement Of Capacitor Control Switch , Street Light With Led Fittings , Earthing Pits Etc At Certain Otm Accn And Residential Area At Af Stn Rajokri Of Ge ( Af ) Gu Repair/Maint. Submission Date for this Tender is 19-05-2020. Electrical Maintenance Tenders in GE (AF) Gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

24141520
Corrigendum : Repair/Maintenance Of Electrical Appliances At Sub Stations Including Replacement Of Capacitor Control Switch , Street Light With Led Fittings , Earthing Pits Etc At Certain Otm Accn And Residential Area At Af Stn Rajokri Of Ge ( Af ) Gu Repair/Maint
Open Tender
Indian
Haryana
GE (AF) Gurgaon
19-05-2020

Tender Details

Repair/Maintenance Of Electrical Appliances At Sub Stations Including Replacement Of Capacitor Control Switch , Street Light With Led Fittings , Earthing Pits Etc At Certain Otm Accn And Residential Area At Af Stn Rajokri Of Ge ( Af ) Gu Repair/Maint Of Electrical Appliances At Sub Stations Including Replacement Of Capacitor Control Switch , Street Light With Led Fittings , Earthing Pits Etc At Certain Otm Accn And Residential Area At Af Stn Rajokri Of Ge ( Af ) Gurgaon

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Apr-2020 Pospondnit Date 05-05-2020
2 04-May-2020 Pospond Date 19-05-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 82000.0 /-
Tender Value
INR 40.98 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINT OF ELECTRICAL APPLIANCES AT SUB STATIONS INCLUDING REPLACEMENT OF CAPACITOR CONTROL SWITCH, STREET LIGHT WITH LED FITTINGS, EARTHING PITS ETC AT CERTAIN OTM ACCN AND RESIDENTIAL AREA AT AF STN RAJOKRI OF GE (AF) GURGAON
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Comprehensive maintenance of oil cooled servo voltage stabilizer by isolating, disconnecting of input/output, supply cable, opening of top of voltage stabilizer, detecting of fault, u/s component in control panel /dimmer stat /PCB etc, cleaning of serviceable parts/ component, including replacement of worn out spare parts etc, if required all as directed. \nNote:- Cost of replacement of worn out cable for wiring shall deemed to be included in quoted unit rate.
2 1.01 Voltage stabilizer of capacity 25 KVA three phase 3 Each Job
3 1.02 Voltage stabilizer of capacity 75 KVA three phase 1 Each Job
4 1.03 Voltage stabilizer of capacity 300 KVA three phase 1 Each Job
5 1.04 Voltage stabilizer of capacity 450 KVA three phase 2 Each Job
6 2 M&L for Dehydration including filtration and cleaning of Transformer oil by dehydrating machine incl testing of sample before and after dehydration, filtration and replacement of silica gel all as directed\nNote:- Contractor has to arrange the dehydration machine and testing kit without any extra cost to the dept. Test report to be submitted after completion of Job. 3000 Litre
7 3 Supply & Filling /pouring of up to the appropriate level Transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as directed \nNote:- Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site.\n 409 Litre
8 4 M&L for defect rectification of HT 11 KV cable laid in trenches by locating fault with help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator for cable of any size XLPE 11 KV complete all as directed 3 Each Job
9 5 Supply, jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core X 120-185 Sqmm XLPE cable of 11000 volts (E) grade complete all as specified and as directed. (Make / Model - Birla 3 M Ltd, Raychem RPG) \n 3 Each Job
10 6 Supply, jointing and testing outdoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core X 95 Sqmm XLPE cable of 11000 volts (E) grade complete all as specified and as directed. (Make / Model - Birla 3 M Ltd, Raychem RPG) \nNote for Item Nos. 5.00 to 6.00:- Cost of cutting of existing end termination joint shall deemed to be included in quoted unit rate. 3 Each
11 7 Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 95 Sqmm and laid in trenches/ ducts/ pipe or on poles complete all as specified and as directed. 100 RM
12 8 Ditto all as per item No. 7 described here-in-before but size 3.5 core X 50 Sqmm 150 RM
13 9 Ditto all as per item No. 7 described here-in-before but size 3.5 core X 35 Sqmm 180 RM
14 10 Ditto all as per item No. 7 described here-in-before but size 4 core X 25 Sqmm 300 RM
15 11 Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables, pipes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. 136 Cum
16 12 Returning, filling in, including spreading, levelling, watering and well ramming in layers\nnot exc 25 cm thick in soils complete all as specified and as directed. 32 Cum
17 13 Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. 104 Cum
18 14 M&L for boring/auguring suitable hole & insertion of 65 mm dia GI pipe including pipe not less than 600 mm below existing PCC/ road/ hard standing complete all as directed.\nNotes :- Cost of equipment, tools & plants & material required for boring shall deemed to be included in the quoted rates .\n 20 RM
19 15 M&L for sand cushioning for cable protection in trenches complete all as specified and as directed. 54 Cum
20 16 Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and as directed. 4600 Each
21 17 Taking down the existing cables from trenches of any size complete all as directed. 730 RM
22 18 M&L for earthing complete with galvanized steel earth plate electrode size 600 x 600 x 6mm thick buried directly in ground vertically not less than 4m below normal ground level with the top edge of the earth plate not less than 3.25 m below the normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron earth strip 25x4 mm means of galvanised iron bolts, nuts, check nuts and washers and earth strip protected by galvanised iron pipe 40mm dia bore light grade with all fittings from top edge of earth plate to body of equipments fixed with and including mild steel clamp made out of FI 32x6mm and also including provision of GI pipe 20mm dia bore light grade for watering including test point 75x75x25mm all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, funnel including 40mm thick RCC slab cover and testing on completion complete all as specified and as directed. 8 Each Set
23 19 Comprehensive maintenance of transformer by isolating, disconnecting of input/output, supply cable, opening of top of transformer, detecting of fault, u/s component etc, cleaning of serviceable parts/ component, including replacement of worn out spare parts etc, if required complete all as directed.
24 19.01 Transformer 300/400 KVA 3 Each
25 19.02 Transformer 160/250 KVA 2 Each
26 19.03 Transformer 50/75/100 KVA 3 Each
27 20 Taking out of VCB trolley from HT Control Panel 11 kV, 3 phase, 630 Amp, 18.4 kA (Make CG) and cleaning the trolley with CRC removing all dust, carbon etc greasing the mechanical parts, gears lever charging, male female contact and spring holder & material and labour for calibration of IDMT numerical relay as per existing load for earth fault, over current, short circuit including setting the relay on required electric load and testing on earth fault, short circuit and over load with the help of relay testing kit including replacement of all fuses with existing rating complete all as directed. 9 Each
28 21 M&L for maintain earthing pit complete with copper earth plate electrode size 600 x 600 x 3.15mm thick buried directly in ground vertically not less than 4m below normal ground level with the top edge of the earth plate not less than 3.25 m below the normal ground level by filling surrounding all sides by mixture of charcoal and common salt and replacing copper earth strip 20X 3 mm means of copper iron bolts, nuts, check nuts and washers and earth strip protected by galvanised pipe 40mm dia bore light grade with all fittings from top edge of earth plate to body of equipments fixed with and including mild steel clamp made out of FI 32x6mm and also including provision of GI pipe 20mm dia bore light grade for watering all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, funnel including 40mm thick RCC slab cover and testing to get required result on completion of maintenance complete all as directed. 40 Each
29 22 Taking down and dismantling HPSV street light fitting for 70/150/250 watt capacity of any make/type from pole/GI pipe unserviceable items to be kept in safe custody and taken as credit complete all as directed. 45 Each
30 23 Taking down of worn out PVC insulated copper cable 1.5 sqmm from street light fitting to junction box including conduit pipe complete all as directed. 250 RM
31 24 M&L for wiring PVC insulated, stranded sheathed copper cable conductor size 1.5 Sqmm 3 core and drawing through and including S&F steel rigid conduit not less than 20mm dia and fixed on pole including 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable connected to earth including connecting to earth dolly complete all as specified and as directed. 250 RM
32 25 Supply and fix LED street light luminaries IP-66 grade of protection with 24 High power LED of 45 watt rating and extendable up to 48 watt rating with unique peanut lens to ensure uniform distribution complete all as directed. Make: CG or its equivalent in Wipro/ Havells/ Surya\n 45 Each
33 26 M&L for bracket for street light fitting made of 40mm bore light grade GI tube bent to shape required, fixed with and including MS flat iron clamps, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete including taking down the existing bracket and refixing and connecting up the light fitting etc complete all as directed 45 Each Job
34 27 Supply and fix in replacement of steel weather proof, dust proof, duly powder coated street light junction box of size 300 x 200 x 105mm including MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as directed. \nMake : Hensel/Sintex/Universal Switch Gear control \nNote:- The rates quoted shall inclusive of provision and fixing of suitable lugs and glands for cable connection. 80 Each
35 28 Supply and fix in replacement of automatic timer switch panel mounted enclosure consisting of ON/OFF switch based on LUX level power contactor 40 Amps, 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as directed. \nMake : Kakatiya/Healer/Bajaj.\nNote:- (i) Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr shall deemed to be included in the unit rate. \n(ii) Provn of glands and lugs shall deemed to be included in the quoted rate. 2 Each
36 29 M&L for rewinding of fans with same gauge of super enamelled copper wire complete varnishing, baking, connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with knots /bolts/ washer /split pin and blade screws etc testing, complete all as directed :-
37 29.01 Ceiling fan 1200 /1400 mm sweep 15 Each
38 29.02 Exhaust fan 300 mm sweep 15 Each
39 29.03 Exhaust fan 450 mm sweep 15 Each
40 30 Supply and fix in repair new metal bush bearing made out of gun metal/ brass of same size suitable for ceiling fans, wall mounted fan and exhaust fans complete all as directed. 45 Each
41 31 Supply and fix in repair ball bearing suitable for the following fans: Make: NBC/SKF/Tata
42 31.01 Ceiling fan 1200 /1400 mm sweep 15 Each
43 31.02 Exhaust fan 300 mm sweep 15 Each
44 31.03 Exhaust fan 450 mm sweep 15 Each
45 32 Supply and fix in repair capacitor 2.5 mfd, 400 volt, 50 Hz complete all as directed. Make : Tibcon 60 Each
46 33 Supply and fix in repair capacitor 4 mfd, 400 volt, 50 Hz complete all as directed. Make : Tibcon 60 Each
47 34 S&F MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as directed 2 Each
48 35 S&F MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA complete all as directed 2 Each
49 36 S&F MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as directed 3 Each
50 37 S&F MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as directed 3 Each
51 38 Supply & fix anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as specified & as directed 100 Each
52 39 Supply & fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified & as directed 60 Each
53 40 Comprehensive maintenance of Capacitor bank panel by isolating, disconnecting of input/ output, supply cable, detecting of fault, u/s component in panel ,cleaning of serviceable parts/ component, including replacement of worn out switches LED indicator, spare parts, Welding of Panel door & replacement of Door lock, replacement of old wiring with 2.5 sqmm to 6 sqmm etc, if required complete all as directed. \nNote:- Replacement of Capacitor of various size shall be measured & paid separately 8 Each
54 41 S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 5 KVAR complete all as directed 8 Each
55 42 S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 10 KVAR complete all as directed 5 Each
56 43 S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 15 KVAR complete all as directed 4 Each
57 44 S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 20 KVAR complete all as directed 4 Each
58 45 S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 25 KVAR complete all as directed 3 Each
59 46 S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 50 KVAR complete all as directed 2 Each
60 47 Comprehensive maintenance of EMF panel by isolating, disconnecting of input/output, supply cable, detecting of fault, u/s component in panel, cleaning of serviceable parts/ component, including replacement of worn out switches LED indicator, spare parts, Welding of Panel door & replacement of Door lock etc, if required all as specified and directed. Replacement of Contactor, relay, WLC, replacement of old wiring with 2.5 sqmm to 6 sqmm etc. of various size shall be measured & paid separately 8 Each
61 48 Supply and fix in replacement of 32 to 160 Amp, 415 Volts, 50 Hz Power contactor of coil voltage 240 Volts, complete all as directed. \nMake: L&T/ Schneider/ Havells 8 Each
62 49 S&F of 3 phase water level controller, 415 Volt, 50 Hz complete all as directed. 5 Each
63 50 S&F of 3 phase phase protector relay, 415 Volt, 50 Hz complete all as directed. 5 Each
64 51 S&F of 3 phase single line preventer 415 Volt, 50 Hz complete all as directed. 4 Each
65 52 Supply, install, testing, commissioning and testing in replacement factory made feeder pillar compartmentalised outdoor type, weather proof, dust and vermin proof double door front and rear openable made out of 3.15 mm thick CRCA sheet and angle iron 45x45x 6mm duly powder coated, suitable for floor /platform mounting of CPRI certified and IP65 class suitable for 415 volt, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars of rating 900 Amps installed on porcelain /SMC insulator with apron for cable entry, closing locking arrangement with and including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS 694 marked, 1100 volt grade of appropriate size (but not less than 2.5 sqmm ) and comprising of the following\nIncoming :-\n(a) ACB 415, 4 pole, 600 Amp, 50 Hz micro processor based release unit type MP4 LSIG draw out type specially fix for incoming supply with overload short circuit and earth fault protection (service breaking capacity 50 KA with spring loaded liver & key locking in drawn out position with under voltage release and motor operating system for charging as well as manual charging coil complete all as specified and directed - 01 No\n 2 Each
66 52.01 Item No. 52.00 Contd.......\nNote:- Cost of retrofitting of existing panel shall deemed to be included in the quoted rate \n(b) Digital Voltmeter 0-500 volts digital type with 4 way rotary selector switch -01 \n(c) Digital ammeter 0-400 Amp digital type with 4 way rotary switch -01 No\n(d) CTs ratio 400/5 A , class 1, ISI marked -01 set of three\n(e) Indicating lamps -01 Set of three\nOutgoing :-\n(a) MCCB 3 pole, 125 Amp, 50 Hz, 415 volts, 36 KA with magnetic and thermal release -04 Nos \n(b) MCCB 3 pole, 250 Amp, 50 Hz, 415 volts, 36 KA with magnetic and thermal release -02 Nos\n(c) MCCB 3 pole, 200 Amp, 50 Hz, 415 volts, 25 KA with magnetic and thermal release -03 Nos \nPlatform of panel:- Platform for the panel with PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate),15 cm thick in foundation, brick work in CM 1:6 with sub class B old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) on top and grouting bolts etc for panel. The platform shall be at a height of 45 cm above the nearest road level. The platform shall be constructed as per Manufacturer drawing and design.
67 53 Supply, install, testing and commissioning in replacement of AMF panel capacity 62.50 KVA cubical floor mounted type made out of MS sheet of not less than 2 mm thick with both side openable hinged cover for easy accessibility with necessary control circuit fuses aluminium bus bar of suitable size TPN.The panel shall have indicating instruments and switches and provn of incoming and outgoing electric connection. The AMF control panel should be manufactured preferably by the manufacturer of DG set or by the approved manufacturer of LT panels is universal switch gear, shalabh switch gear, milestone or equivalent the following accessories.:- \n(a) AC voltmeter 0-500 volts flush type - 01 No. Make :- AE/IMP/MECO\n(b) Suitable voltmeter selector switch having ON/OFF - 01 No. Make : AE /IMP/MECO\n(c) Frequency Meter 100 mm square flush type- 01 No. Make :AE /IMP/MECO\n(d) Ammeter 0-200 Amps with CTS flush type - 01 No. Make : AE /IMP/MECO\n(e) Battery charger one number ammeter. Make : AE/Havells \n 1 Each
68 53.01 Item No. 53.00 contd.....\n(i) Transformer /Rectifier unit\n(ii) DC ammeter Make : AE/Havells\n(iii) Charging rate selector switch off/trickle/Booster. Make AE/ Havells\n(f) Main supply air break contactor 3 pole of suitable rating Make : Siemens/L & T /ABB\n(g) Alternator air break contactor 3 pole of suitable rating and providing with a separate over load delay for over load protection. Make : Siemens / L & T /ABB\n(h) Set of control relays and timer - 01 set \n(i) Mode selector switch off/auto main test.\n(j) Set of push buttons starter /stop/ acknowledge /test /main/ breaker/ close trips - 01 set.\n(k) Audio alarm hooter - 01 set \n(l) KW meter flush type - 01 No. Make : Havells/ Capital/ Jaipur.\n(m) Power factor meter - 01 No. Make : Havells /AE/ L & T \n(n) Suitable size MCCB -02 Nos
69 54 S&F, installing, testing and commissioning in replacement of AMF panel capacity 25 KVA cubical floor mounted type made out of MS sheet of not less than 2 mm thick with both side openable hinged cover for easy accessibility with necessary control circuit fuses aluminium bus bar of suitable size TPN.The panel shall have indicating instruments and switches and provn of incoming and outgoing electric connection. The AMF control panel should be manufactured preferably by the manufacturer of DG set or by the approved manufacturer of LT panels is universal switch gear, shalabh switch gear, milestone or equivalent following accessories.:- \n(a) AC voltmeter 0-500 volts flush type - 01 No. Make :- AE/IMP/MECO\n(b) Suitable voltmeter selector switch having ON/OFF - 01 No. Make : AE /IMP/MECO\n(c) Frequency Meter 100 mm square flush type- 01 No. Make :AE /IMP/MECO\n(d) Ammeter 0-200 amps with CTS flush type - 01 No. Make : AE /IMP/MECO\n(e) Battery charger one number ammeter. Make : AE/Havells \n 1 Each
70 54.01 Item No. 54.00 contd.... \n(i) transformer /Rectifier unit\n(ii) DC ammeter Make : AE/Havells\n(iii) Charging rate selector switch off/trickle/Booster. Make AE/ Havells\n(f) Main supply air break contactor 3 pole of suitable rating Make : Siemens/L & T /ABB\n(g) Alternator air break contactor 3 pole of suitable rating and providing with a separate over load delay for over load protection. Make : Siemens / L & T /ABB\n(h) Set of control relays and timer - 01 set \n(i) Mode selector switch off/auto main test.\n(j) set of push buttons starter /stop /acknowledge /test /main/ breaker/ close trips - 01 set.\n(k) Audio alarm hootere - 01 set \n(l) KW meter flush type - 01 No. Make : Havells/ Capital/ Jaipur.\n(m) Power factor meter - 01 No. Make : Havells /AE/ L & T \n(n) Suitable size MCCB -02 Nos
71 55 M&L for defect rectification of LT 1.1 KV cable laid in trenches by locating fault with help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator for cable of any size XLPE 1.1 KV complete all as directed 3 Each Job
72 56 Supply, jointing and testing indoor/outdoor type cold shrinkable straight through cable joint including all material and accessories suitable for 3.5 core X 50-95 Sqmm XLPE cable of 1100 volts (E) grade complete all as specified and as directed. (Make / Model - Birla 3 M Ltd, Raychem RPG) \nNote :- Cost of cutting of existing end termination joint shall deemed to be included in quoted unit rate. 2 Each
73 57 Supply and fix in replacement of Lead acid maintenance free Battery 12 Volts 120 AH of existing type & size suitable for DG Sets. Make : EXIDE/AMCO including initial charging. 2 Each