Providing Electrical Works To Newly Allotted Space For Centre Of Excellence In Advanced Manufacturing At Kv School Building, NITT, Tiruchirappalli-Tamil Nadu

National Institute Of Technology-NIT has published Providing Electrical Works To Newly Allotted Space For Centre Of Excellence In Advanced Manufacturing At Kv School Building. Submission Date for this Tender is 21-04-2020. Electrical Maintenance Tenders in NITT, Tiruchirappalli Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

24136839
Providing Electrical Works To Newly Allotted Space For Centre Of Excellence In Advanced Manufacturing At Kv School Building
Open Tender
Indian
Tamil Nadu
NITT, Tiruchirappalli
21-04-2020

Tender Details

Providing Electrical Works To Newly Allotted Space For Centre Of Excellence In Advanced Manufacturing At Kv School Building

Key Value

Document Fees
Refer document
EMD
INR 26373.0 /-
Tender Value
INR 13.18 Lakhs /-

BOQ Items

Name of Work: Providing Electrical works to newly allotted space for Centre of Excellence in Advanced Manufacturing at KV school building in production Dept.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 WIRING\n
2 1.1 \nWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.\n
3 1.11 Group C 12 Point
4 1.2 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
5 1.21 Group C 24 Point
6 1.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
7 1.31 5/6 A switch 24 Each
8 1.32 15/16 A switch 19 Each
9 1.33 3 pin 5/6 A socket outlet 24 Each
10 1.34 6 pin 15/16 A socket outlet 19 Each
11 1.4 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 4 Each
12 1.5 Supplying and fixing following size/ modules, Plastic/GI box in surface/recess etc. as required.
13 1.51 Plastic surface box - 4 module \t\t\r\n 5 Each
14 1.52 Plastic surface box - 6 module \t\t\r\n 12 Each
15 1.53 Plastic surface box - 8 module \t\t\r\n 7 Each
16 1.6 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
17 1.61 4 Module 5 Each
18 1.62 6 Module 12 Each
19 1.63 8 Module 7 Each
20 1.7 DLP plasticTrunking wiring (Make: Legrand/MK)
21 1.71 DLP Pastic Trunking 105x50mm and accessories Flexible cover 85mm -1No, Joints for cover 85mm width-1No,Basejoint-25Nos,Clips-15Nos,Separation partition-1No,Endcap-2No,Internal angles-adjustable from 80 degr - 120 deg - 1No, VDI accessories for internal angles-1No,VDI accessories for external angles -1No, Flat angles -1No, VDI accessories for flat angles-1No, Flat junctions-1No, Flat junctions for specific size-tap off to an 80mm wide branch -1No, VDI accessories for juctions -1No, Wall crossing -1No, Capacity change -1No,Capacity change-1No, partition junction -1No, Cable ties base -1No. \n(Make: Legrand/MK) 178 Metre
22 1.72 DLP Pastic mini Trunking system 32x12.5mm and accessories Endcap-1No,Internal angles-adjustable from 85 degr - 95 deg - 1No,Flat junctions -1No.(Make: Legrand) 124 Metre
23 1.8 DLP Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed as required.(Make: Finolex/Polycab/RR)
24 1.81 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire 422 Metre
25 1.82 4 X 6.0 sq. mm + 2 X 6.0 sq. mm earth wire 349 Metre
26 2 MCCB, MCB & DB'S
27 2.1 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.\n\n200 A, 36kA, FPMCCB\n 2 Each
28 2.2 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.\n\nTriple pole\n 11 Each
29 2.3 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 11 Each
30 2.4 Supplying and fixing of following rating,Three/four pole,415 volts,Isolator/MCB in the existing MCB/DB complete with connections,testing and commissioning erc.as required.
31 2.41 Triple Pole 40-63A MCB 1 Each
32 2.42 Four Pole 40-63A MCB 4 Each
33 2.5 Supplying and fixing FP sheet steel enclosure on surface/ recess along with following amps 415 volts "C" curve FP MCB complete with connections, testing and commissioning etc. as required.\n\n2-4 Pole Enclosure only 2 Each
34 2.6 Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 160-250 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision of 160 amps TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB's/ MCCB) as required .(Note : Vertical type MCCB TPDB is normally used where 3 phase outlets are required.) (Make: Legrand/Siemens)\n\n12 way, 250A, Double door 1 Each
35 2.7 Supplying and fixing of following amps, 230/415volts, SPN/TPN industrial type, socket outlet, with 2/4pole and earth, metal enclosed plug top along with following amps "C" curve, DP/FP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. (Make: Legrand - Tempra or Equivalent)
36 2.71 6-32A 2P+E - DP industrial socket 8 Each
37 2.72 6-32A 3P+N+E - FP industrial socket 14 Each
38 3 EARTHING
39 3.1 Supplying and laying 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm)\n 20 Metre
40 3.2 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.\n 20 Metre
41 3.3 Supplying and fixing cosmos earthig electrode systems.\n\nCosmos Roma 40mm Dia 3 Mtrs Length with moisture Enhancer 25kg. 2 Each
42 4 MV CABLE LAYING \n\nLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. (1 or 6per Circuit) \n
43 4.1 Upto 35 sq. mm 149 Metre
44 5 MV CABLE JOINTING & END TERMINATION\n\nSupplying and making indoor end termination with copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.\n
45 5.1 1X6 Sq.mm 10 Each
46 5.2 1X16 Sq.mm 12 Each
47 5.3 1X25Sq.mm 6 Each
48 5.4 1X35Sq.mm 6 Each
49 6 SUPPLY OF ELECTRICAL ITEMS
50 6.1 Supplying and fixing extra conduit down rod\n\nSupplying and fixing of tube light fitting hook & chain including chipping,fixing & surfacing to make good condition. 24 Each
51 6.2 Supplying and fixing of wall mounting fan of following 450mm sweep , suitable for operation on 230 Volts, single phase, 50 Hz, AC Supply including wall braket rod and resistance type regulator as required. \n\nWall mouting fan (Medium type) 12 Each
52 6.3 Repairing and painting works.\n
53 6.31 Removing of Tube light fittings & Fans with necessary arrangents etc. as req. 86 Each
54 6.32 Labour charges for fixing of three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, with necessary interconnections. 2 Each
55 6.33 Labour charges for fixing DP sheet steel enclosure on surface/ recess with necessary connections, testing and commissioning etc. as required. 11 Each
56 6.34 Labour charges for fixing of SP MCB in existing DB including connection, testing & commissioning etc. as req. 20 Each
57 7 Supplying of Cables. \n\nSupplying and fixing of following size ISI marked PVC insulated and unsheathed copper single core conductor cable of 1.1 KV grade as required.(Make:Finolex,Gloster,Polycab and Havells with 18 months warranty from the date of supply)
58 7.1 1x16.0sq mm 432 Metre
59 7.2 1x25.0sq mm 231 Metre
60 7.3 1x35.0sq mm 231 Metre
61 8 Supply of Light Fixtures with Lamps \n\nSupply and fixing of indoor decorative LED fitting of high efficincy luminaire range suitable for recessed/surface mounting in moudular ceiling with 600 x 600/300X300/round type/down light module and extemely low hight of 50 mm. (Make: philips, Wipro, Crompton Greaves, Bajaj ) \n
62 8.1 1x1 LED Cirrus Mini Pro SM200C LED15S 4000 PSU OD WH 41 Each
63 8.2 2x2 rcess mounting LED BZRSQL 36W GZ 24 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail