Renovation Work In Room . No . 4-7 For Centre Of Excellence In Advanced Manufactiuring At Old Kv School Building, NIT Tiruchirappalli-Tamil Nadu

National Institute Of Technology-NIT has published Renovation Work In Room . No . 4-7 For Centre Of Excellence In Advanced Manufactiuring At Old Kv School Building. Submission Date for this Tender is 20-04-2020. Building Work Tenders in NIT Tiruchirappalli Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

24131073
Renovation Work In Room . No . 4-7 For Centre Of Excellence In Advanced Manufactiuring At Old Kv School Building
Open Tender
Indian
Tamil Nadu
NIT Tiruchirappalli
20-04-2020

Tender Details

Renovation Work In Room . No . 4-7 For Centre Of Excellence In Advanced Manufactiuring At Old Kv School Building

Key Value

Document Fees
Refer document
EMD
INR 31000.0 /-
Tender Value
INR 15.47 Lakhs /-

BOQ Items

Name of Work: Renovation work in Room.No. 4-7 for Centre of Excellence in Advanced Manufactiuring at old KV school building.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
2 1.1 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). 2 Cum
3 2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
4 2.1 Cement mortar 1:6 (1 cement : 6 coarse sand) 3 Cum
5 3 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
6 3.1 Second class teak wood 0.3 Cum
7 4 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
8 4.1 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws 18 Sqm
9 5 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 18 Sqm
10 6 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 18 Sqm
11 7 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 1 Each
12 8 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
13 8.1 250x16 mm 5 Each
14 9 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
15 9.1 200x10 mm 14 Each
16 10 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
17 10.1 125 mm 16 Each
18 11 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
19 11.1 Single rubber stopper 1 Each
20 12 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
21 12.1 Size of Tile 600x600 mm 310 Sqm
22 13 12 mm cement plaster of mix :
23 13.1 1:6 (1 cement: 6 fine sand) 20 Sqm
24 14 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
25 14.1 Water thinnable cement primer 20 Sqm
26 15 Applying priming coat:
27 15.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) 18 Sqm
28 16 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :
29 16.1 Two or more coats on new work 800 Sqm
30 17 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
31 17.1 Two or more coats on new work 18 Sqm
32 18 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
33 18.1 One or more coats on old work 200 Sqm
34 19 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 18 Cum
35 20 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
36 20.1 Of area 3 sq. metres and below 10 Each
37 21 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
38 21.1 For thickness of tiles above 25 mm and up to 40 mm 110 Sqm
39 22 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 190 Sqm
40 23 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :
41 23.1 15 mm to 40 mm nominal bore 30 Metre
42 24 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge:
43 24.1 Up to 150 mm diameter 20 Metre
44 25 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 90 Sqm
45 26 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 10 Cum
46 27 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. INTERNAL WORK - EXPOSED ON WALL
47 27.1 20 mm nominal outer dia Pipes 20 Metre
48 27.2 25 mm nominal outer dia Pipes 20 Metre
49 28 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
50 28.1 25 to 40 mm nominal bore 1 Each
51 29 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
52 29.1 25 mm nominal bore 2 Each
53 30 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
54 30.1 For fixed portion\nPowder coated aluminium (minimum thickness of powder coating 50 micron) 100 Kg
55 30.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)\nPowder coated aluminium (minimum thickness of powder coating 50 micron) 20 Kg
56 31 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge.
57 31.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side 15 Sqm
58 32 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
59 32.1 With float glass panes of 5.50 mm thickness 10 Sqm
60 33 Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 1 Each
61 34 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre- painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
62 34.1 With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7) 320 Sqm
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail