Military Engineer Services-MES has published Demolition And Reconstruction Of Certain Lattice Masts At Ts Dolphin Hill Visakhapatnam. Submission Date for this Tender is 19-08-2020. Demolition Work Tenders in Visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 15-Apr-2020 | date corr 85363 dt 15 Apr 2020 | Date | 13-05-2020 |
2 | 05-May-2020 | 85363 Date corr 05 May 2020 | Date | 26-05-2020 |
3 | 20-May-2020 | 85363 date corr 20 May 2020 | Date | 15-06-2020 |
4 | 08-Jun-2020 | 85363 date corr 08 Jun 2020 | Date | 22-06-2020 |
5 | 15-Jun-2020 | 85363 date corr 15 Jun 2020 | Date | 29-06-2020 |
6 | 22-Jun-2020 | 85363 date corr 22 Jun 2020 | Date | 06-07-2020 |
7 | 29-Jun-2020 | 85363 date corr 29 Jun 2020 | Date | 13-07-2020 |
8 | 06-Jul-2020 | 85363RevisedDrawings | Other | 17-07-2020 |
9 | 10-Jul-2020 | Date Corrigendum | Date | 22-07-2020 |
10 | 15-Jul-2020 | 85363DateCorr | Date | 31-07-2020 |
11 | 17-Jul-2020 | revised BOQ | BOQ | 31-07-2020 |
12 | 25-Jul-2020 | 85363 Date Corrigendum 25 Jul 2020 | Date | 10-08-2020 |
13 | 31-Jul-2020 | Tender Corrigendum | Technical Bid | 10-08-2020 |
14 | 03-Aug-2020 | 85363_Date_Corrigendum | Date | 12-08-2020 |
15 | 12-Aug-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-08-2020 |
Name of Work:DEMOLITION AND RECONSTRUCTION OF CERTAIN LATTICE MASTS AT TS DOLPHIN HILL VISAKHAPATNAM | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Dismantling structural steel work including doors,gates but except trusses.\nNOTE : The existing lattice towers shall be dismantled which are 30 to 36 Metres hight. | BI01010001010000000000000515BI0100001120 | 775 | Quintal |
2 | 2 | Demolition of un-reinforced cement Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed. | BI01010001010000000000000515BI0100001121 | 47.5 | Cu.m |
3 | 3 | Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed. | BI01010001010000000000000515BI0100001122 | 101 | Cu.m |
4 | 4 | Disposal of debris obtained from demolition upto a distance of 3.0 KM out side MD land at location as shown by Eng-In-charge complete. | BI01010001010000000000000515BI0100001123 | 20.5 | Load |
5 | 5 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses,pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. | BI01010001010000000000000515BI0100001124 | 20 | Point |
6 | 6 | Taking down carefully sub main wiring including batten/conduit by unscrewing from wall, ceiling and making good surfaces to match with original status all as specified and directed. | BI01010001010000000000000515BI0100001125 | 60 | RM |
7 | 7 | Taking down carefully light fitting any type any light. | BI01010001010000000000000515BI0100001126 | 8 | Each |
8 | 8 | Taking down MCB DB any type with MCB SP, MCB SPN. | BI01010001010000000000000515BI0100001127 | 8 | Each |
9 | 9 | Taking down carefully aluminium strip of size 25x3mm. | BI01010001010000000000000515BI0100001128 | 180 | RM |
10 | 10 | Taking out carefully LT UG cable 4 core 16 Sqmm | BI01010001010000000000000515BI0100001129 | 60 | RM |
11 | 11 | Taking down unserviceable Aviation obstruction light LED type 10W filament-less bulb complete including standard fixing arrangements. | BI01010001010000000000000515BI0100001130 | 8 | Each |
12 | 12 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in Hard/ Dense soil complete all as specified and as directed. | BI01010001010000000000000515BI0100001131 | 196 | Sq.m |
13 | 13 | Excavation over areas not exceeding 1.5m depth and getting out in hard/ dense soil complete all as specified and as directed. | BI01010001010000000000000515BI0100001132 | 386 | Cu.m |
14 | 14 | All as per Serial item No.13 above but depth exceeding 1.5m and not exceeding 3.0m | BI01010001010000000000000515BI0100001133 | 103 | Cu.m |
15 | 15 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth of soft/loose soil; for foundation, etc. or for wells, manholes, etc. and n exc 1.5 m in depth and getting out all as specified and directed. | BI01010001010000000000000515BI0100001134 | 54 | Cum |
16 | 16 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm all as specified and directed. | BI01010001010000000000000515BI0100001135 | 52 | Cum |
17 | 17 | Removing excavated materials to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified | BI01010001010000000000000515BI0100001136 | 521 | Cum |
18 | 18 | M&L for Plain Cement Concrete M-7.5 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete all as specified and as directed. | BI01010001010000000000000515BI0100001137 | 24 | Cum |
19 | 19 | M&L for Reinforced Cement Concrete M-30 design mix as in foundation, including raft footing foundation, beam ,bases for columns etc, basement, slabs, under reamed piles and mass concreteall as specified and as directed. | BI01010001010000000000000515BI0100001138 | 293 | Cum |
20 | 20 | M&L for Formwork to sides of concrete foundation, footing, base of columns, raft and raft beam, sides of soffits of foundation & plinth beam and similar work in flat with fair finished surface all as specified and as directed. | BI01010001010000000000000515BI0100001139 | 196 | Sqm |
21 | 21 | M & L TMT bars 10 mm dia and over cut to length bent to shape required cranking hooking and binding with and including MS wire not less than 0.90 mm dia MS wire all as specified and as directed. | BI01010001010000000000000515BI0100001140 | 8685 | Kg |
22 | 22 | M & L TMT bars 6 to 8 mm mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips all as specified and as directed. | BI01010001010000000000000515BI0100001141 | 430 | Kg. |
23 | 23 | S&F Nut and bolt 30mm dia of size 1.66m long with the required shape for base plate, fixed in RCC foundation with proper supporting arrangements for keeping the bolts in required alignment complete all as specified and as directed. | BI01010001010000000000000515BI0100001142 | 192 | Nos |
24 | 24 | S&F HSFG (High Strength Friction Grip) Bolts (machine made) exc 15cm & not exc 22.5cm long with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut. | BI01010001010000000000000515BI0100001143 | 16768 | Nos |
25 | 25 | S&F Structural steel Fe 410W (Gde E-250 Quality B) for Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. complete all as shown in drawings and as specified and as directed.\nNOTE : The work is involved in Lattice Tower of height 30 Mtrs. | BI01010001010000000000000515BI0100001144 | 106456 | Kg |
26 | 26 | S&F Structural steel Fe 410W (Gde E-250 Quality B) for Staircase (framed) including stringers, treads, landing, balusters, hand rails etc, including cleats, brackets, etc. complete all as shown in drawings and as specified and as directed.\nNOTE : The work is involved in Lattice Tower of height 30 Mtrs. | BI01010001010000000000000515BI0100001145 | 18047 | Kg |
27 | 27 | M&L for Preparation of new steel surfaces and applying two coats of PU finished (International Orange / White) Paint over two coats of epoxy Micaceous Protection (Not less than 100 micron) over two coats of zinc rich epoxy primer (Not less than 60 micron) for tower complete all as specified and directed. \nNOTE : The work is involved in Lattice Tower of height upto 30 Mtrs. | BI01010001010000000000000515BI0100001146 | 5112 | Sqm |
28 | 28 | M&L for applying two coats of cement base paint over a coat of white wash on newly plastered surface complete all as specified and directed. | BI01010001010000000000000515BI0100001147 | 336 | Sqm |
29 | 29 | M&L for Hardcore 150mm thick spread thickness with stone/broken boulders or quarried stone of size not exc 63mm deposited, spread and leveled in layers not exc 15cm thick, watered and rolled/rammed to a true surface, complete all as specified and as directed. | BI01010001010000000000000515BI0100001148 | 74.25 | Cum |
30 | 30 | M&L for PCC 150mm thick , M-7.5(using 40 mm graded granite stone aggregate) in foundations, complete all as specified and as directed. | BI01010001010000000000000515BI0100001149 | 495 | Sq.m |
31 | 31 | M&L for PCC 150mm thick, M-15 (using 40 mm graded granite stone aggregate) as in flooring, curb or similar type of work, complete all as specified and as directed. | BI01010001010000000000000515BI0100001150 | 495 | Sq.m |
32 | 32 | Design, Fabrication, supply , erection and testing of winch pulley machine with handle system (Steering handle), Manually operated wire rope at steel structural tower of 30 M high capable of handling 50 kg weight all as specified and directed by Engr-in- charge. \n(a) Gear pulley (steering wheel) 01 No.\n(b) Penion - 04 Nos\n(c) Rope SS 16mm dia. 120 feet.\n(d) Shaft 04 Nos 32 inch/32mm.\n(e) Roller pulley 10 inch/3mm.\n(f) MS plate 24 mm, 75x75cm- 03 Nos.\nNOTE : a) Make of SWR shall be " Usha Martin"\n b) All accessories used in Winch (Pulley, Gear, Rope, roller etc ) shall be conforming to relevant IS .B43 | BI01010001010000000000000515BI0100001151 | 8 | Each |
33 | 33 | S&F LT Sheet Metal Enclosure made out of CRCA sheet 3.15 mm thick out door Pedestal type of suitable size but not less than (0.3x0.3x0.2)Mtr totally enclosed with front opening, hinged door with projected and raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 with MCB 32 Amps SPN for single phase LT AC, 50 Hz 230 V, suitable size of alluminium bus bar as required all as specified and directed. | BI01010001010000000000000515BI0100001152 | 2 | Each |
34 | 34 | M&L for wiring circuit along with earth wire with PVC insulated unsheathed stranded copper conductor of size 2x1.5 sqmm conforming to IS 694 (1100V grade) drawn through and including non metallic rigid PVC conduit 20mm dia medium grade conforming to IS-9537 and PVC conduit accessories complete with concealed/semi concealed sheet metal terminal boxes made out of 2mm thick MS sheet covered with 3 mm thick laminated sheet top cover for fixing switches along with 1 x 1.0 sqmm wire connected to common earth dolly and earth in distribution board complete for one light/fan point controlled by one switch all as specified and directed.B63 | BI01010001010000000000000515BI0100001153 | 150 | RM |
35 | 35 | S&F LED Security light fitting 72 watt complete all as specified and directed.\nMake : Cromption Greaves Model no. LSTP-72-CDL or equivalent model in Bajaj/Havells/Philips. | BI01010001010000000000000515BI0100001154 | 8 | Each |
36 | 36 | S&F MCB DB SPN 4 way single door type 240 volts with 200 Amps rated bus bar all as specified and directed. | BI01010001010000000000000515BI0100001155 | 4 | Each |
37 | 37 | S&F Isolator MCB SPN 32 Amps 240 Volts all as specified and directed. | BI01010001010000000000000515BI0100001156 | 4 | Each |
38 | 38 | S&F MCB SP, 5 to 32 Amps 240 Volts all as specified and directed. | BI01010001010000000000000515BI0100001157 | 8 | Each |
39 | 39 | Supply, laying, testing and commissioning LT XLPE insulated, PVC sheathed (heavy duty) galvanised steel strip or wire armoured electric power cable with aluminium conductor, 1100 Volts grade of size 2 core 10 Sqmm all specified and directed (From taping panel to MCB Enclosure). | BI01010001010000000000000515BI0100001158 | 160 | RM |
40 | 40 | All as item No 39 but of size 6 sqmm 2.0 core . | BI01010001010000000000000515BI0100001159 | 100 | RM |
41 | 41 | M&L for Earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts check nuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 50 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe for watering all as specified and directed and tested on completion. | BI01010001010000000000000515BI0100001160 | 4 | Each |
42 | 42 | S&F GI strip 32 mm x 6 mm Complete with saddles and fixing screws for fitting the strip | BI01010001010000000000000515BI0100001161 | 60 | Rm |
43 | 43 | M&L for Sand cushioning for underground cable complete all as specified and directed. (Note: Punned down thickness will only measured for the purpose of payment.) | BI01010001010000000000000515BI0100001162 | 20 | Cum |
44 | 44 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm all as specified and directed.(For LT cables) | BI01010001010000000000000515BI0100001163 | 1330 | Each |
45 | 45 | Aviation obstruction light LED type filament-less bulb with 10 Watt bulb complete including standard fixing arrangements all as specified and as directed. \nMake : Bajaj Cat NO. BGAB302 LED or equivalent model in Philips/Hovels/CG. | BI01010001010000000000000515BI0100001164 | 8 | Each |
46 | 46 | S&F PVC insulated, FRLS, PVC Armoured, 2.5 sqmm ,3 core cable, multi stranded conductor laid in ground or fixed to wall all as specified and as directed. | BI01010001010000000000000515BI0100001165 | 160 | Rm |
47 | 47 | S&F time switches, 250 V, single Phase, 20 Amp rating with contactor Fitted inside steel enclosure all as specified. | BI01010001010000000000000515BI0100001166 | 4 | Each |
48 | 48 | S&F Air termination, single pointed aluminium rod 12mm dia and 300mm long all as specified and as directed | BI01010001010000000000000515BI0100001167 | 8 | Each |
49 | 49 | S&F Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. | BI01010001010000000000000515BI0100001168 | 320 | Rm |
50 | 50 | S&F Test point terminal box of size 200x100x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed. | BI01010001010000000000000515BI0100001169 | 8 | Each |
51 | 51 | M&L for Earthing complete with Copper earth plate electrode 600x600x3.15 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to Copper strip of 20x 3.15 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts check nuts and washers of brass all as specified and shown in electrical plate No 5 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil M-10 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 50 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe for watering all as specified and directed and tested on completion. | BI01010001010000000000000515BI0100001170 | 8 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy