Purvanchal Vidyut Vitaran Nigam Limited has published Special Repair And Maintenance Of 33/11 K . V S/S Dubauliya Distt . Basti. Submission Date for this Tender is 22-04-2020. Substation Tenders in Basti Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: SPECIAL M&R WORK OF 33/11 K.V. S/s DUBAULIYA DISTRICT- BASTI. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Dismantling brick work or stone work in lime or cement mortar and including stacking of materials as directed by the Engineer-in-charge within a distance of 60 metres. (CSI No. 15.01) | 1 | CuM | |
2 | 2 | Dismantling of existing damaged Mud Faska over the roof. Cleaning the surface with wire brush, removal and disposal of rubbish at a distace 100 Meters also including the cost of cleaning and stacking of usable materials etc., including all labour, material required for proper completion of work. (CSI No. 15.14) | 100 | Sqm | |
3 | 3 | Dismantling doors or window leaves including stacking of materials as directed by the Engineer I/C within a dist. 60 M. (CSI No. 15.09) | 15 | Sqm | |
4 | 4 | Dismantaling doors and windows chowkhats including stacking of materials as directed by Engg-in-Charge within a distance of 60 meters. (CSI No. 15.10) | 10 | Sqm | |
5 | 5 | Cement concrete with 4cm gauge approved hard stone ballast, coarse sand (F.M. 1.5 to 2.0) and cement in proportion of 12:6:1 including supply of all materials,labour,side shuttering if required and T&P etc. required for proper completion of work. (CSI No. 5.02) | 0.27 | CuM | |
6 | 6 | Providing of Dr. Fixit 301 pidicrete URP & mixing it properley with cement in the proportion of 1:1.5 apply two coat to the prepared surface including cost of labour, material T&P etc. as required for proper completion of work as directed by E/I (NSI) | 100 | Sqm | |
7 | 7 | Mild Steel or Iron work in heavy sizes such as trusses built up gates, door frames, record, racks roof work gates etc. wrought to required form including holes rivetting or welding where necessary and also fixing in proper position and alignment including cost of all materials supplied by contractor. (CSI No. 9.01) | 0.5 | MT | |
8 | 8 | TMT/Tor steel in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage, bend, hooks and authorized overlapping shall be measured. (Steel shall be arranged by the contractor) (CSI No. 9.03) | 0.45 | MT | |
9 | 9 | RCC work with cement approved coarse sand (F.M.1.8 to 2.5) and 2 cm gauge graded approved hard stone ballast like grainite, quartzite etc from Dalla, Jhansi or other quarries and approved coarse sand in proportion 1:1.5:3 in slab excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P. (CSI No. 5.24) | 8 | CuM | |
10 | 10 | Providing and mixing of Dr. Fixit LW+in RCC/CC/Plaster etc. 200ml per bag fo cement as directed by E/I including supply of all material, labour and T&P etc required for proper completion of work. NSI | 10 | Ltr | |
11 | 11 | 12 mm thick plaster with cement mortar consisting of one part of cement & three part of coarse sand (1:3) minimum thickness not to be less then 10 mm including supply of all material , labour and T&P etc for proper completion of work. (CSI No. 11.06) | 100 | Sqm | |
12 | 12 | Add for extra labour to all items of plaster if done in ceiling. (CSI NO. 11.10) | 100 | Sqm | |
13 | 13 | 3 mm thick floating coat of neat cement finish including supply of all materials, labour and T&P etc. required for proper completion of the work.( cement consumtion 0.044 bag/Sq.m.) (CSI No. 11.20) | 100 | SqM | |
14 | 14 | 1st class brick (class-150) work in 1:6 cement and coarse and (F.M. 1.8 to 2.5) super structure including necessary cutting and moulding of brick as requird & also including honey comb brick thickness of wall 230mm. (CSI 6.01+6.07+6.08) | 4 | Cum | |
15 | 15 | 12 mm thick plaster with cement mortar consisting of one part of cement & four part of coarse sand (1:4), minimum thickness not to be less then 10 mm including supply of all material, labour and T&P etc for proper completion of work. (CSI No. 11.07) | 30.37 | Sqm | |
16 | 16 | Providing and fixing steel glazed window and ventilators of standard rolled Mann or Mahavir steel sections conforming to IS 7452-1974 as per drawing joints metered & welded with 100x14x3.15 mm holdfast embedded in cement concrete block 15x10x10 cm. Size of 1:3:6 proportion I.E. First part of cement 3 part of approved coarse sand & 6 part of graded stone (aggregated 20mm. Nominal size) S/F of glass panes of plain pin headed 4mm. Thick nuts glazing clips and special putty of approved make complete and including a cost of red oxide paint. The fabrication should conform to I.S.1038-1975. (Aluminum beading with rubber packing included). (CSI No. 9.17) | 10 | Sqm | |
17 | 17 | S/F Galvanized Mosquitos proof heavy quality iron wire gauge (14x24) over window frames and including supply of C.P. Teak wood battens 8cm x 1cm. and including supply and fixing of necessary screws, all materials,labour and T&P etc. required for proper complete. (CSI No. 9.18) | 10 | Sqm | |
18 | 18 | Painting or varnishing on previously painted old wood or iron work including its sand papering,rubbing and cleaning as required including supply of all materials, labour and T&P etc. required for proper completion of the work. Paint to be used should conform to the I.S. 103-1950. (CSI No. 13.01+13.02) | 100 | Sqm. | |
19 | 19 | Applying Birla or equivalent putty on new interior or exterior surface over one coat of water based cement primer of ICI or equivalent brand for smoothening and levelling of the surface as per requirement and direction of Engineer I/C including cost of all material, labour, T & P etc required for proper completion of work. (CSI No. 13.20+13.21) | 650 | Sqm | |
20 | 20 | Finishing walll with water proof emulsion paint of ACE of Asian Paint or equivalent make including 3 coats of above and including one priming coat on already well preparied new wall surface to give an even shed including cost of all materials, labour and T & P etc. complete NSI | 250 | Sqm | |
21 | 21 | Two coat with Acrylic emulsion paint of Berger/Asian/ICI OR equivalent paint (Paint and water in the ratio 1:1 by volume) over previousaly painted surface of cement concrete, cement plaster and bricks including supply of all materials, labour and T&P etc. required for proper completion of the work. (C.S.I.No.13.25+13.26) | 398 | Sqm. | |
22 | 22 | Repair to plaster in 1:6 patches including removal of old plaster racking out joints to 1 cm.(3/8") depth,watering the area and then replastering the same including supply of all materials, labour and T&P etc. required for proper completion of the work . (CSI No. 20.02+11.07) | 160 | Sqm | |
23 | 23 | Repair to 2.5 cm (1") cement concrete floor in patches including up to 10cm. Depth renewing 8cm. Base concrete consisting of one partr cement, 4 parts aproved coarse sand and 8 parts of 4cm. gaugr brick ballast as in C.C Floor including supply of all materials.labour and T&P etc. required for proper completion of the work. (CSI No. 20.03+12.01) | 38 | Sqm | |
24 | 24 | Renewing panes of glass including supply of glass with putty and brads including supply of all materials, labour and t&P etc. required for proper completion of the work.(a) glass of 4 mm thick. (CSI No. 20.04) 806b | 8 | SqM | |
25 | 25 | Dismantling existing plaster including disposal of refuse as directed by the Engineer-I/C within a distance of 60 M. (CSI No. 15.11) | 350 | Sqm. | |
26 | 26 | Providing and fixing white glazed China earthen ware water closet squatting " Orisa type" pan weaper size 580mmx140mm Hindustan Make or other equivalent approved make of Ist quality with 100mm dia. White glazed P or S trap fittings including cutting & making good the walls and floors wherever required with cement sand and grit mortar not less than 1:4 the seat and trap shall have to be fixed over minimum 3" thick c.c. in proportion of 12:6:1 including cost of all materials, labour(C.S.I.No. 27.01+27.24) | 1 | No | |
27 | 27 | Providing and laying floor with 20 mm. thick Kota stone over base cement mortar 1:4 mix and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete and including supply of all materials labour and T&P etc required for proper completion of the work. (CSI No. 12.17) | 100 | SqM | |
28 | 28 | Wiring Point for light with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as PSI 131C | 5 | No | |
29 | 29 | Same as above but wiring for fan as PSI 133 B | 3 | No | |
30 | 30 | Wiring for Plug point as PSI 134B | 5 | No | |
31 | 31 | S/F Angle/Batten Holder PSI 405 | 6 | No | |
32 | 32 | S/wiring Sub main with 2 No. 4sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit. PSI 216B | 50 | R.M. | |
33 | 33 | Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect (P.S.I. No 1413.CAT- AAA). | 6 | No. | |
34 | 34 | Supply and burying earth electrodes for lightening conductor of 600 mm. x 600 mm. x 6 mm. G.I. Plate vertically with its top at least 3 meters below ground level complete with 20 mm. G.I. Plat vertically with its top atleast 3 meters below ground level complete with 20mm. G.I. Pipe for watering funnel, 30 cm. Square C.I. Frame with hinged cover masonry housing alternate layers of coke/ charcoal and salt at least 150 mm. thick alround etc. completed in all respects as per P.S.I. No.703. | 1 | No | |
35 | 35 | Supply and fixing ofSurface / Flush mounting 4 ways V TPN distribution board with additional metel door without MCB complete in all respect, as directed at site by Engineer in charge. PSI NO. 1026 C CAT- A | 1 | No | |
36 | 36 | Supply and fixing of 5 Amps to 32 Amps MCB 9KA/10KA HAVELLS or equivalent make (P.S.I. No. 1002CAT A) | 3 | No | |
37 | 37 | Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect. PSI NO. 1112A | 3 | No | |
38 | 38 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect. PSI NO.1451 CAT- AAA | 4 | No | |
39 | 39 | S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. PSI 1139A | 8 | No | |
40 | 40 | SPECIALTERMS & CONDITIONS :-\n | |||
41 | 40.01 | The work shall be started in immediately form the given date of start and to be completed on urgent basis. If any constractor pretend by linking the pending payment against other works bill and stop the work or slow the progress of work, Action shall be taken against as per agreement clause. | |||
42 | 40.02 | The Contractor who already executing some work in the department/division and stop the work/linger on the work without any reason. The performance shall be treated unsatisfactory, part-II of such type of contractor may not be opened. | |||
43 | 40.03 | Before execution of work, the contractor must cover the control panel on his own cost with the help of tirpal. | |||
44 | 40.04 | Due to rainy season, when work is not in progress the contractor must cover the roof on his own cost with help of plastic of required thickness. | |||
45 | 41 | TERMS & CONDITIONS :-\n | |||
46 | 41.01 | Firms are advised to visit the site of work and make themselves acquainted with site condition. No clian what so evel shall be entertained after submission of the tendere. | |||
47 | 41.02 | Cement shall be arranged by the contractor on his own cost, fresh cement conforming to relevant I.S. of brand such as J.K., Birla Uttam, A.C.C., Ambuja or equivalent of major plants shall be used in the work, Contractor shall make proper storage arrangement of cement at site of works to the satisfaction of E/I. Cement should always be stored in such a manned to be esily accessible of proper inspection and in a suitable weather tight building or storage shed to protect the cement from dampness. | |||
48 | 41.03 | During execution of work contractor may be asked to perform the quality test of material as and when required in an approved lab and its cost will be borne by the contractor | |||
49 | 41.04 | TOR stell shall be of Fe 415 grade and of approved make by E/I. | |||
50 | 41.05 | Quantities are approximate and vary up to any extent on either side as per requirement of site condition. | |||
51 | 41.06 | All above work shall be executed as per UPPWD /UPPCL specification or as per direction of E/I. | |||
52 | 41.07 | All electrification material /fittings and other materials of door/ windows including fittings etc shall be got approved from E/I before fixing the same at site of work. | |||
53 | 41.08 | ACE Acrylic distemper and paint etc shall be of ASIAN /BERGER/J&N brand of approved quality which shall be got approved before using in the work from the E/I. | |||
54 | 41.09 | Flush door and other aluminium fittings etc shall be got approved by E/I . Flush door shutter shall be 100% water proof of ISI marked. | |||
55 | 41.1 | If specifications for any item of work are not covered by any of the documents mentioned in the contract the same shall be decided and conveyed by the E/I to the contractor. | |||
56 | 41.11 | IOld bricks , if any shall be recovered from dismantling of brick work in cement/ lime mortar as follows:-\n(a) 60% of the total quantity of dismantling brick work shall be treated as received and shall be reused @Rs.4200.00 per 1000 in relevant item of old B/W.\n(b) 25% of the total quantity of dismantled work shall be treated as brick bats and shall be recovered @Rs.850.00 per Cum at site and balance shall be treated as malba. | |||
57 | 41.12 | Old and dismantled door and windows if any shall be property of contractor which shall be recovered @Rs. 200.00 per Sqm from the contractor. | |||
58 | 41.13 | Old and unusable steel / scrap if any of RCC /RB work shall be recovered@Rs.24.00 per kg from the contractor. | |||
59 | 41.14 | Kachchi shuttering in RCC work is strictly prohibited . If RCC is done with kachchi shuttering , 20% of rate of RCC shall be reduced without giving any notice to the contractor. | |||
60 | 41.15 | The work shall be carried out upto approximately 8m height for double storied building. | |||
61 | 41.16 | The rates are exclusive of GST which shall be paid extra as applicable. For reimbursement of GST contractor must be registerd with Sale tax Department. | |||
62 | 41.17 | Other terms and conditions are same as attached in enclosed tender document. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy