}

Rep And Maint Of Dist Trans , Rep/Repl Of Two/Four Pole Str , Lt Cables And Street Lgt And Cleaning Of Oh Reser , Shallow Wells , Ug Sumps , Oh Service Tanks And Rep/Maint Of Ro Plants And Sand Filters At Ins Baaz Technical Area Under Ge ( I ) Camp, GE (I) Campbell Bay-Andaman And Nicobar Islands

Military Engineer Services-MES has published Rep And Maint Of Dist Trans , Rep/Repl Of Two/Four Pole Str , Lt Cables And Street Lgt And Cleaning Of Oh Reser , Shallow Wells , Ug Sumps , Oh Service Tanks And Rep/Maint Of Ro Plants And Sand Filters At Ins Baaz Technical Area Under Ge ( I ) Camp. Submission Date for this Tender is 07-05-2020. Construction Material Tenders in GE (I) Campbell Bay Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

24109374
Corrigendum : Rep And Maint Of Dist Trans , Rep/Repl Of Two/Four Pole Str , Lt Cables And Street Lgt And Cleaning Of Oh Reser , Shallow Wells , Ug Sumps , Oh Service Tanks And Rep/Maint Of Ro Plants And Sand Filters At Ins Baaz Technical Area Under Ge ( I ) Camp
Open Tender
Indian
Andaman And Nicobar Islands
GE (I) Campbell Bay
07-05-2020

Tender Details

Rep And Maint Of Dist Trans , Rep/Repl Of Two/Four Pole Str , Lt Cables And Street Lgt And Cleaning Of Oh Reser , Shallow Wells , Ug Sumps , Oh Service Tanks And Rep/Maint Of Ro Plants And Sand Filters At Ins Baaz Technical Area Under Ge ( I ) Campbell Bay , Excavation In Trenches Not Exceeding 1 . 5M Wide And Not Exceeding . 1 . 5M In Depth For Foundation And Not Exceeding 10 Sqm On Plan And Not Exceeding 1 . 5M In Depth On Plan And Getting Out In Any Soil Complete All As Specified And Directed . , Ditto All As Per Sl Item No 1 But For Excavation Exc 1 . 5 Metre And N . Exc 3 . 0 Metre , Returning , Filling In , Including Spreading , Levelling , Watering And Well Ramming In Layers Not Exceeding 25 Cm . Complete All As Specified And Directed . , Removing Excavated Material Not Exceeding 50 Metre & Depositing At A Level Not Exceeding 1 . 5 Metre Above The Starting Point , Complete All As Specified And Directed . , Supply And Lay In Trenches/ Wall/ Pole Cable Xlpe Insulated , Screened Pvc Bedded , Glavanized Steel Strip Or Wire Armoured , Electric Power Cable ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 35 Sqmm 3 . 5 Core Complete Including Taking Down Existing Cable All As Specified And Directed . ( Note : Excavation And Earth Work , Sand Cushioning And Pcc Cable Cover Will Be Measured And Paid Separately ) . , Ditto All As Per Sl Item No 5 But For Aluminium Conductor Of Size 25 Sqmm 4 Core , Ditto All As Per Sl Item No 5 But For Aluminium Conductor Of Size 16 Sqmm 4 Core , Ditto All As Per Sl Item No 5 But For Aluminium Conductor Of Size 16 Sqmm 2 Core , Supply & Laying Hdpe Double Wall Corrugated ( Dwc ) Pipes Of Grade Pe 63 & Pn-4 , Isi Marked With Outer Dia 50 Mm & Inner Dia 38 Mm Conforming To Is : 14930 Part Ii Including Necessary Fittings & Fixtures Laid In Trenches Or Poles For Lt Cable Protection Etc Complete All As Specified And Directed . , Supply And Fixing Of Gi Pipe Of Size 50 Mm Bore , Light Grade With And Including Fittings On Pole/In Floors/On Walls For Cable Protection Complete All As Specified And As Directed . , Dismantling Unserviceable Burnt Out Mccb By Disconnecting The Cable And Supply & Fix New Mccb , 63 Amps , 4 Pole 16Ka , 440 Volts In The Existing Panel Boards With New Bolts , Nuts , Lugs & Glands Etc Complete All As Specified And As Directed . , Ditto All As Per Sl Item No 11 But For Mccb 100 Amps , 4 Pole 16Ka , 440 Volts , Ditto All As Per Sl Item No 11 But For Mccb 125 Amps , 4 Pole 16Ka , 440 Volts , Supply & Fix Synthetic Insulating Mat Of Size 2000X1000x19mm For Lt Panel , Complete All As Specified And Directed . , Material & Labour In Repairs To Arrest The Oil Leakage In Transformer By Decaning Transformer Oil Apprx 250 Litre , Dismantling The Top Cover Along With Conservator Tank , Replacing The Top Gasket Washers Etc , Replacement Of Ht/Lt Bushes Complete Dismantling The Cooling Fins And Welding As Necessary To Arrest Oil Leakage Reassembling Transformer Refilling Duly Filtered/Tested Oil For A Capacity Upto 200Kva Transformer Including Two Coats Of Synthetic Enamel Paint After Preparation For Outer Surface , Complete All As Specified And Directed . , Material & Labour For Filteration Of Transformer Oil/Potential Transformer Oil ( Immersed Type ) And Servo Voltage Stabilizer Through Stream Line Filtration Plant For Extracting Moisture Content In The Oil And Carbon Deposits And Bringing The Dielectric Strength To 50Kv For A Minute With A Sphere Gap Of 2 . 5Mm Of Test Kit And Also Checking The Acidity Of Oil With A Acidity Test Kit And Submitting The Necessary Test Report And Certificate And Refilling The Same Complete All As Specified And Directed . , Supply And Filling Of Top Up Transformer Oil Conforming To Is 335-1993 Ehv Grade With And Including Testing Complete All As Specified And As Directed . Make: Electrol , Power Oil , Supply & Fix In Repairs Breather Set Suitable Up To 200 Kva Transformer Including Silica Gel Complete All As Specified And As Directed . , Material & Labour For Prepration Of Old Painted Surfaces Of Rcc Poles By Scratching With Wire Brush And Cleaning Etc . And Applying Two Coats Of Cement Based Paint White And Black Colour In Bottom Including Applying Two Coats Of Synthetic Enamel Paint On Bracket Of Street Light & Clamb Complete All As Directed . , Material & Labour For Removing The Existing Paint Of 2 Pole/4 Pole Structure Completely By Scratching With Wire Brushes And Cleaning Thoroughly Applying Two Coats Of Synthetic Enamel Paint ( Silver Colour ) Over One Coat Of Primer On Prepared Surface By Spray Pinting Complete All As Specified And Directed . , Supply & Fix Light Emitting Diode Street Light , 60 Watts , Pressure Die Cast Aluminium Housing Led Steet Light Lnuminaries , Heat Resistant Toughened Glass With Frame , Ip 66 Protection In And Including Bracket Made Out Of Gi Pipe 50Mm Dia , Light Grade , Bent To Shape As Directed , 1 . 2M Long With Two Set Of Clamp Made Out Of Flat Iron 50X6mm , Bolt , Nuts And Washers & Two Coats Of Aluminium Paint Over One Coat Of Red Oxide/Zinc Chrome Primer , Connecting Electrically With Pvc Multi Stranded Copper Cable Of Suitable Size In With And Including 60 Watts Lamp Complete All As Specified And Directed . Make: CromptonNexus+ Cat Part No . Lstp-60-Cdl Or Equivalent . , Servicing And Cleaning Of God , Fixed And Moving Contact , Ht Jumbers , Drop Out Fuse , Springs And Cleaning By Carbon Tetra Chloride ( Ctc ) And Applying Grease For Easy Operation Complete All As Specified And Directed By The Engineer-In-Charge . , Dismantling And Taking Out Old Unserviceable Earthing And Material & Labour For Earthing With Galvanised Steel Earth Plate Electrode 60Cmx60cmx6 . 3Mm Burried Earth Pit Not Less Than 2 . 25M Depth Below Normal Ground Level With To Edge Of The Plate Vertically To Depth Of Not Less Than 1 . 5 M Below Ground Level Connected To & Including Gi Strip Of Size 25X4 Mm As Earthing Lead Connecting To Equipment By Mean Of Gi Bolts & Nuts Etc With Provision Of Char-Coal And Salt Etc All As Per Electrical Plate No-3 Of Ssr-2010 Including Rcc Cover And Ms Angle Iron Frame , Watering With Gi Pipe 20 Mm Dia ( Medium Grade ) & Ms Funnel , Concrete Pit Including Excavation And Earthwork And Testing Complete All As Specified And Directed . Note : 1 . Refilling Of The Earth Pit Shall Be Carried Out With Black Cotton Soil . 2 . Gi Strip 25X4 Mm & Gi Protection Pipe Upto 7 . 5 M Length Will Be Measured Under This Item . , Material & Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/Pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc . As Required 25X4 Mm Galvanised Iron Strip Complete Including Taking Down Existing Old Gi Strip All As Specified And Directed By Engineer In Charge , Material & Labour For Cleaning Of Shallow Water Wells Of Size 10M Dia , 4M Depth By Dewatering The Complete Well , Removing The Sediments Settled At The Bottom And Depositing Where Directed , Scraping The Walls With Wire Brush And Washing With Clear Water And Applying One Coat Of White Wash Both Internally And Externally And Writing The Date Of Cleaning , Due Date Of Cleaning And Capacity Of Well In Paint ( White Letters On Black Background ) Complete All As Specified And Directed . , Material & Labour For Cleaning Of Rcc Water Tanks By Dewatering The Complete Tank , Removing The Sediments Settled At The Bottom Of Tank , Scraping The Walls And Bottom Of Tank With Wire Brush And Cleaning With Bleaching Powder Solution , Washing With Clear Water And Applying One Coat Of White Wash Both Internally And Externally And Writing The Date Of Cleaning , Due Date Of Cleaning And Capacity Of Tank In Paint ( White Letters On Black Back Ground ) Including Removing Of Any Vegetation Growth On And Around The Tank Com

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Mar-2020 Date Corrigendum Date 20-04-2020
2 18-Apr-2020 Corrigendum No 3 Date 07-05-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail