Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Apr-2020 Corrigendum1 Date 23-05-2020
2 14-May-2020 Corrigendum2 Date 06-06-2020
3 30-May-2020 Corrigendum3 Date 20-06-2020
4 12-Jun-2020 Corrigendum4 Date 09-07-2020
5 03-Jul-2020 CorreigendumD Date 21-07-2020
6 15-Jul-2020 Corrigendum15Jul Date 05-08-2020
7 28-Jul-2020 Corrigendum28Jul Date 25-08-2020

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
INR 44.30 Crore /-

BOQ Items

Name of Work: PROVN OF KLP ACCN INCL STP FOR DIV ENGR REGT AT MIL STN KALUCHAK, JAMMU
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Lumpsum price worked out by the contractor for Building work as listed in Schedule 'A' Part-I.\n 1 Lump sum
2 2 Lumpsum price worked out by the contractor for Internal water supply as listed in Schedule 'A' Part-II.\n 1 Lump sum
3 3 Lumpsum price worked out by the contractor for Internal electric supply as listed in Schedule 'A' Part-III.\n 1 Lump sum
4 4 Lumpsum price worked out by the contractor for Plumbing work as listed in Schedule 'A' Part-IV.\n 1 Lump sum
5 5 Lumpsum price worked out by the contractor for Site Clearance and Tree cutting as listed in Schedule 'A' Part-V.\n 1 Lump sum
6 6 Lumpsum price worked out by the contractor for Road, Path and culvert work as listed in Schedule 'A' Part-VI.\n 1 Lump sum
7 7 Lumpsum price worked out by the contractor for Compund wall, Security fencing and steel gate as listed in Schedule 'A' Part-VII.\n 1 Lump sum
8 8 Lumpsum price worked out by the contractor for Sewage disposal as listed in Schedule 'A' Part-VIII.\n 1 Lump sum
9 9 Lumpsum price worked out by the contractor for Rain water Harvesting Work as listed in Schedule 'A' Part-IX.\n 1 Lump sum
10 10 Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule 'A' Part-X.\n 1 Lump sum
11 11 Lumpsum price worked out by the contractor for External Electrification as listed in Schedule 'A' Part-XI.\n 1 Lump sum
12 12 Lumpsum price worked out by the contractor for External Water supply/ Hot water supply & Arboriculture works as listed in Schedule 'A' Part-XII.\n 1 Lump sum
13 13 Lumpsum price worked out by the contractor for Lightening Protection as listed in Schedule 'A' Part-XIII.\n 2 Lump sum
14 14 Lumpsum price worked out by the contractor for Demolition/ dismantling as listed in Schedule 'A' Part-XIV.\n 1 Lump sum
15 15 INTERNAL ELECTRIFICATION :
16 16 Point wiring with 1.5 sqmm copper conductor cables (multistranded), FRLS PVC insulated , unsheathed (using colour code as per IS), 1100 Volts grade in and including concealed PVC rigid conduit of not less than 1.8mm thick heavy duty (ISI marked) of adequate size with sunk cast iron/pressed steel terminal box of adequate size with 3mm thick plastic laminated sheet top cover for one light /fan /exhaust fan point controlled by one, one way 5 Amp switch including continuous 1.5 sqmm copper conductor (multistranded using colour code) FRLS PVC insulated and unsheathed cable as earth wire connected to earth dolly complete all as specified and directed 3123 Per Point
17 17 All as per item No 16 here-in-before but for one multi pin 5 pin socket outlet 5 Amps independent. 743 Per Point
18 18 All as per item No 16 here-in-before but for one 3 pin socket outlet 5 Amps on the same board with other switches. 200 Per Point
19 19 Point wiring with 1.5 sqmm copper conductor cables (multistranded), FRLS PVC insulated, unsheathed (using colour code as per IS), 1100 Volts grade in and including stove enamelled steel conduit (on surface recess) for flame proof light fitting of suitable size having thickness not less than 1.8mm thick heavy duty (ISI marked) of adequate size with sunk cast iron/pressed steel terminal box of adequate size with 3mm thick bakelite sheet top cover for one light /fan /exhaust fan point controlled by one, one way 5 Amp switch including continuous 1.5 sqmm copper conductor (multistranded using colour code) FRLS PVC insulated and unsheathed cable as earth wire connected to earth dolly complete all as specified and directed. 16 Per Point
20 20 Point wiring with 2.5 sqmm copper conductor cables (multistranded), FRLS PVC insulated , unsheathed (using colour code as per IS), 1100 Volts grade in and including concealed PVC rigid conduit of not less than 1.8mm thick heavy duty (ISI marked) of adequate size with sunk cast iron/pressed steel terminal box of adequate size with 3mm thick plastic laminated sheet top cover for one 3 pin socket outlet 15 Amps on independent board controlled by 16 Amp switch including continuous 2.5 sqmm copper conductor (multistranded using colour code) FRLS PVC insulated and unsheathed cable as earth wire and connected to earth dolly complete all as specified and directed. 180 Per Point
21 21 Submain wiring with 2 run of single core, 4 sqmm FRLS PVC insulated and unsheathed, multi stranded copper conductor cable FRLS (using colour code as per IS) with and including 4 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded cable (using colour code as per IS) connected to common earth point and connected to earth dolly drawn through PVC rigid conduit of suitable size, heavy grade (ISI marked) having thickness not less than 1.8mm (ISI marked) with and including all accessories, complete all as specified and directed.\nNote : Two runs of single core cable with one run of earth cable and conduit shall be measured as one run. 695 RM
22 22 Submain wiring with 2 run of single core, 6 sqmm FRLS PVC insulated and unsheathed, multi stranded copper conductor cable FRLS (using colour code as per IS) with and including 6 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded cable (using colour code as per IS) connected to common earth point and connected to earth dolly drawn through PVC rigid conduit of suitable size, heavy grade (ISI marked) having thickness not less than 1.8mm (ISI marked) with and including all accessories, complete all as specified and directed.\nNote : Two runs of single core cable with one run of earth cable and conduit shall be measured as one run. 270 RM
23 23 Submain wiring with 2 run of single core, 10 sqmm FRLS PVC insulated and unsheathed, multi stranded copper conductor cable FRLS (using colour code as per IS) with and including 10 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded cable (using colour code as per IS) connected to common earth point and connected to earth dolly drawn through PVC rigid conduit of suitable size, heavy grade (ISI marked) having thickness not less than 1.8mm (ISI marked) with and including all accessories, complete all as specified and directed.\nNote : Two runs of single core cable with one run of earth cable and conduit shall be measured as one run. 440 RM
24 24 Submain wiring with 2 run of single core, 16 sqmm FRLS PVC insulated and unsheathed, multi stranded copper conductor cable FRLS (using colour code as per IS) with and including 16 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded cable (using colour code as per IS) connected to common earth point and connected to earth dolly drawn through PVC rigid conduit of suitable size, heavy grade (ISI marked) having thickness not less than 1.8mm (ISI marked) with and including all accessories, complete all as specified and directed.\nNote : Two runs of single core cable with one run of earth cable and conduit shall be measured as one run. 35 RM
25 25 S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with and including LED lamp 1x 9 Watt complete all as specified and directed. 469 Each
26 26 SPN MCB DB 6 way, sheet metal enclosures double door 240 Volts AC, 50 Hz AC complete all as specified and directed 16 Each
27 27 S&F MCB SP 240 Volt, 50 Hz, 10 KA of rating 6 Amp to 32 Amp complete all as specified and directed. 731 Each
28 28 S&F MCB SP 240 Volt, 50 Hz, 10 KA of rating 40 Amp complete all as specified and directed. 15 Each
29 29 S&F MCB SP 240 Volt, 50 Hz, 10 KA of rating 50 Amp to 63 Amp complete all as specified and directed. 4 Each
30 30 S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 0.5 Amp to 5 Amp complete all as specified and directed. 27 Each
31 31 S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 10 Amp complete all as specified and directed. 16 Each
32 32 S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 16 Amp complete all as specified and directed. 5 Each
33 33 S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 20 Amp complete all as specified and directed. 12 Each
34 34 S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 25 Amp complete all as specified and directed. 5 Each
35 35 S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 32 Amp complete all as specified and directed. 9 Each
36 36 S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 40 Amp complete all as specified and directed. 5 Each
37 37 S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 50 Amp complete all as specified and directed. 5 Each
38 38 S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 40 Amp complete all as specified and directed. 15 Each
39 39 S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 63 Amp complete all as specified and directed. 2 Each
40 40 S&F MCB TPN 240 Volt, 50 Hz, 10 KA of rating 10 Amp complete all as specified and directed. 5 Each
41 41 S&F MCB TPN 240 Volt, 50 Hz, 10 KA of rating 16 Amp complete all as specified and directed. 3 Each
42 42 S&F MCB TPN 240 Volt, 50 Hz, 10 KA of rating 25 Amp complete all as specified and directed. 1 Each
43 43 Distribution Board iron clad, VTPN double door with IP-43, IK-09 protection suitable for MCB TPN as incomer and MCB as outgoing 415 Volts, 3 phase 50 C/s, 4 way complete all as specified and directed. 8 Each
44 44 Distribution Board iron clad, VTPN double door with IP-43, IK-09 protection suitable for MCCB TPN as incomer and MCB as outgoing 415 Volts, 3 phase 50 C/s, 4 way complete all as specified and directed. 7 Each
45 45 Distribution Board iron clad, VTPN double door with IP-43, IK-09 protection suitable for MCCB TPN as incomer and MCB as outgoing 415 Volts, 3 phase 50 C/s, 6 way complete all as specified and directed. 11 Each
46 46 MCCB 415 Volts, TPN, 16 Amp, 16 KA with thermal release adjustable type (80% to 100%) complete all as specified and directed. 1 Each
47 47 MCCB 415 Volts, TPN, 25 Amp, 16 KA with thermal release adjustable type (80% to 100%) complete all as specified and directed. 7 Each
48 48 MCCB 415 Volts, TPN, 32 Amp, 16 KA with thermal release adjustable type (80% to 100%) complete all as specified and directed. 1 Each
49 49 MCCB 415 Volts, TPN, 50 Amp, 16 KA with thermal release adjustable type (80% to 100%) complete all as specified and directed. 7 Each
50 50 MCCB 415 Volts, TPN, 80 Amp, 16 KA with thermal release adjustable type (80% to 100%) complete all as specified and directed. 1 Each
51 51 MCCB 415 Volts, TPN, 100 Amp, 16 KA with thermal release adjustable type (80% to 100%) complete all as specified and directed. 1 Each
52 52 Blanking plate for MCB DB's all as specified and directed.\n 250 Each
53 53 Supply and fixing Ceiling fan complete with accessories 230 Volt, single phase AC supply, 50 Hz, 1200mm sweep BEE 5 Star rated including connecting up with flexible PVC insulated copper cable 3 Core 23/0.0076 from ceiling rose to fan connector complete all as specified and directed.\n 625 Each
54 54 Exhaust fan 300/305 mm sweep, heavy duty including louver shutter and connecting up with and including provision of FRLS PVC insulated multistranded copper cable of size 3 core cable 1.5 sqmm from ceiling rose to connector of fan complete all as specified and directed. 86 Each
55 55 Exhaust fan 450 mm sweep, heavy duty including louver shutter and connecting up with and including provision of FRLS PVC insulated multistranded copper cable of size 3 core cable 1.5 sqmm from ceiling rose to connector of fan complete all as specified and directed. 14 Each
56 56 LED type tube light, box type fitting 1X18W / 20 Watt including LED tube rod 230 Volt, recessed wall mounted LED batten, extruded aluminium heat shrink provided for efficient dissipation and integrated electronic driver complete with all accessories internally pre wired and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to connector of fitting complete all as specified and directed including connection with 3 core flexible copper conductor cable of suitable size from ceiling rose to fitting.. \nMake:- Cat part No. LCTL-18-CDL of Crompton or equivalent in makes of Group-I. 1580 Each
57 57 LED type tube light, box type fitting 1X 20 Watt including LED tube light 20 Watt, 230 V, AC standalone suspended sleek luminair, extruded aluminium heat shrink provided for efficient dissipation and integrated electronic driver complete with all accessories internally pre wired and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to connector of fitting complete all as specified and directed including connection with 3 core flexible copper conductor cable of suitable size from ceiling rose to fitting all as specified and directed.\nMake:- Cat part No.112233 type BPTxn 20W LED 4F WH of Bajaj or equivalent in makes of Group-I. 186 Each
58 58 LED building / street light fitting complete 1X20 Watt, 230 volt, energy saving and environmental friendly long life versatile pressure dicast aluminium IP- 66 road way luminary with high power LED as light source and electronic driver complete mounted on wall/pole with 40mm dia 1.2 mtr long light grade GI Pipe bent to shape mounted on wall with the help of 02 Nos suitable size of FI holding clamp with nuts, bolts and washers and making electrical connection with 1.5 Sqmm three single core PVC insulated unsheathed copper conductor cable multistranded cable from ceiling rose to light fittings, complete with all accessories internally pre wired complete all as specified and directed. \nMake :- LSTS-25-CDL of make Crompton or equivalent in makes of Group-I. 145 Each
59 59 LED light fitting 1 x 10 Watt bulk head surface mounted luminaires in engineering plastic housing with clear prismatic diffuser CCT 6000K comlete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 V, 50 Hz complete all as specified and directed. Mke : Cat part No CG801B10 W make C&S or equivalent in makes of Group-II. 4 Each
60 60 LED flame proof tube light fitting with LED tube 1x20 Watt made of aluminium alloy LM6 complete with all accessories prewired and including connecting up with twin core twisted flexible copper condutor cable of suitable size and IP 65 protection complete all as specified and directed. Make : Cat part No EXTN1LT816/20W of Crompton or equivalent in makes of group-I. 16 Each
61 61 Porch light fiting 1x18W slim design recessed round down lighter with superior light output and integral driver complete. Make : Cat part No. LCDE-18-CDL or equivalent in makes of group-I. 6 Each
62 62 LED Mirror light 14 Watt with lamp, never lie, linnet true reflection without shadow with all accesssories internally pre wired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Crompton cat prt No LCL-14-CDL or equivalent in makes of group-I. 8 Each
63 63 Supply and fixing wall mounted fan with complete accessories 230 Volt, single phase AC supply, 50 Hz, 1200mm sweep BEE 5 Star rated including connecting up with flexible PVC insulated copper cable 3 Core 23/0.0076 from ceiling rose to fan connector complete all as specified and directed.\n 14 Each
64 64 Supply, installation, testing and commissioning of LT feeder pillar box, factory made (Outdoor type), double door, slopy canopy made out of 3.15mm thick CRCA sheet and mounted on angle iron frame of size 65x65x6mm and 450mm high weather/dust proof, factory made, IP-54 with openable shutters on both sides front and rear having locking arrangements, totally enclosed weather proof, powder coated over a coat of primer suitable for 3 Phase, 4 wire 50 C/s, aluminium bus bar of suitable size and capacity, AC supply, electrically connected as per norms and fitted including connecting up all out going MCCB/MCB with suitable size of Alu bus bar or with stranded copper cable and fixing on suitable 'U' shaped PCC platform comprising of the following accessories complete all as specified and directed by Engr in charge :\n(i) Aluminium bus bar with proper colour code -04 Nos. 150 Amp Cap duly fixed on suitable size insulator, nuts bolts etc complete as per OEM recommendations.\n(ii) Indicator Lamp - 01 Set (Set of three)\n(iii) MCCB, 415 Volt, 4 pole, 100 Amps, 25 KA /37 KA rupturing capacity, Ics=100% Icu, thermal Magnetic release, with adjustable setting 80% to 100% - 01 No (Incoming)\n(iv) MCCB TP 25 Amp, 16 KA, 415Volt thermal Magnetic release, with adjustable setting 80% to 100% (Ics=100% Icu) - 04 Nos (Out going)\n(v) Digital Voltmeter 0-500 Volt with toggle switch. \n(v) Digital Ampmeter 0-800 Amp with toggle switch. \n(x) Complete wiring with suitable size copper cable, thimble etc.\nNote : (i) PCC for platform will be measured separately under relevant item.\n 1 Each
65 65 SUMMER APPLIANCES
66 66 Supply, fixing & installation hi wall AC split units indoor/ outdoor complete with cordless remote control unit, inbuilt air ioniser and plasma filter for better indoor air quality and 3 star rating and EER of capacity 2 TR with and including copper tubing of suitable size from indoor to outdoor unit and outdoor to indoor unit duly insulated complete as per OEM recommendations for efficient functioning of AC including fixing on suitable mounting brackets etc all as directed. 1 Each
67 67 S&F of Voltage stablizer for automatic operation, single phase, naturally air cooler, indoor wall mounted type and designed for input variation between 170V to 270V with out put ovoltage stabilized to 230V with accuracy of +2.5%, high /low voltage protection with time delay device, voltmeter, Amps meter and of capacity 5 KVA all as directed.\n 1 Each
68 68 Supply, fixing, installation hi wall AC split units indoor/ outdoor complete with cordless remote control unit, inbuilt air ioniser and plasma filter for better indoor air quality and 3 star rating and EER of capacity 1.5 TR including copper tubing of suitable size from indoor to outdoor unit and outdoor to indoor unit duly insulated complete as per OEM recommendations for efficient functioning of AC including fixing on suitable mounting brackets etc all as directed. 1 Each
69 69 S&F of Voltage stablizer for automatic operations, single phase, naturally air cooler, indoor wall mounted type and designed for input variation between 170V to 270V with out put ovoltage stabilized to 230V with accuracy of +2.5%, high /low voltage protection wih time delay device, voltmeter, Amps meter and of capacity 3 KVA all as directed.\n\n \n\n 1 Each
70 70 Refrigerator, electric driven (Single phase) five star rating, having storage capacity 195 Litre/210 litres, complete with accessories all as directed. \nMake- whirlpool /Samsung /Godrej /LG 2 Each
71 71 Refrigerator, electric driven (Single phase) five star rating , having storage capacity 310 litres, complete with accessories all as directed. Make- whirlpool /Samsung /Godrej /LG 4 Each
72 72 Refrigerator, electric driven (Single phase) five star rating , having storage capacity 360 litres, complete with accessories all as directed. Make- whirlpool /Samsung /Godrej /LG 1 Each
73 73 Supply , Installation, commissioning of metal top Deep freezer of 230 litre capacity having single phase 240V,50HZ, single door complete with accessories all as directed.\nMake : Blue Star, VOLTAS, SHRI RAM (USHA)\n 1 Each
74 74 Supply , Installation, commissioning of metal top Deep freezer of 320 litre capacity having single phase 240V,50HZ, single door complete. Make : Blue Star, VOLTAS, SHRI RAM (USHA)\n 2 Each
75 75 Supply, installation, commissioning of water cooler stainless steel having storage capacity 80 litre and nominal cooling capacity 40 litre per hour with suitable compressor, condensor and condensor fan motor with complete accessories and gas charged complete all as specified and as directed.\nMakes :- Voltas/Blue Sar/Sidhwal 20 Each
76 76 Supply, installation, commissioning of water cooler stainless steel having storage capacity 120 litre and nominal cooling capacity 60 litre per hour with suitable compressor, condensor and condensor fan motor with complete accessories and gas charged complete all as specified and as directed.\nMakes :- Voltas/Blue Sar/Sidhwal 1 Each
77 77 Supply and fixing electronic voltage stablizer for automatic operations, single phase, naturally air cooler, indoor wall mounted type and designed for input variation between 170V to 270V with out put ovoltage stabilized to 230V with accuracy of +/- 2.5%, high /low voltage protection wih time delay device , voltmeter, Amps meter and of capacity 1 KVA complete all as specified and as directed. 21 Each
78 78 Supply, installation, testing and commissioning of Desert Cooler electric driven, 1 single phase of approximate minimum size (600X810X635) mm made out of 2mm thick GI sheet for body with water tank of capacity 50 litres and with front grills and side directions grills, suitable for minimum Air delivery of 4000 cum per hour approx 450mm sweep fan size with mild steel curved blades duly painted with synthetic anti corrosive paint, fitted to body including prewired electric 4 speed switch control and one 6 Amps piano switch. Water immersed pump of minimum capacity 40 watts 1300 rpm suitable for 230 volts, 50 HZ AC supply and one 6 Amps piano switch for fan motor of minimum capacity 105 watts 1400 rpm, 230 volts, 50 HZ and water inlet pipe with brass float valve of size 15mm and outlet with brass drain plug of 20mm. The pad of three sides shall be of honeycomb type. \nNote :- The rate shall be inclusive of 3 core 2.5 sqmm PVC sheathed and insulated flexible copper cable chord 2 metre long with 3 pin 5 Amps top plug for power supply complete all as specified and directed.\nMakes:- Khaitan/Kenstar/Symphony. 224 Each
79 79 EXTERNAL ELECTRIC SUPPLY
80 80 Supply , Installation, connecting, commissioning and testing outdoor type IP-43, plinth mounted transformer powder coated capacity 500 KVA step down 11/0.433KV, outdoor type, copper wound 3 phase 4 wire 50c/s oil immersed naturally cooled with externally cooling tube, core type delta connected on primary (HV) 11 kv side and star connected on secondary(LV) 433V side having tapping ±2.5%, ±5%, ±7.5% and to change by means of hand operating off load tap changing gear on HV side including first filling of new transfomer oil of dielectric strength not less than 40KV with all fittings such as breather drain out valve, (oil tank) conservator tank of suitable capacity with oil level indicator, exhaust vent, temperature guage and accessories as per recommendation of OEM and all as per IS 1180 of 2014 complete all as specified.\n 1 Each
81 81 Construction of platform of size 3000 x 2500 x 1200 mm for installation of transformer with brick steps on one side, chain link fencing around transformer, fencing should have hinged door and locking arrangements complete all as shown on drawing No CEPZ/C-TD/002/13 sht 2/5 complete all as specified. 1 Each Job
82 82 Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendations made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded Copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :- 1 Each
83 82.01 Aluminium bus bar with proper colour code -04 Nos, 1200 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
84 82.02 Indicator Lamp-01 Set (Set of three) with control wiring.
85 82.03 Incoming ACB 800A, 415 volt, 4 pole, Manual draw out type, 50 KA rupturing capacity, lcu=lcs,lcw ( I Sec), with adjustable settings 80% to 100 % thermal maganatic release and standard accessories as applicable.
86 82.04 Outgoing, MCCB, 4 Pole, 63 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics =100% Icu) - 01 No
87 82.05 Outgoing, MCCB, 4 Pole, 100 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %,Thermal Magnetic Release (Ics = 100% lcu) - 02 No
88 82.06 Outgoing, MCCB, 4 Pole, 160 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %,Thermal Magnetic Release (Ics = 100% lcu) - 02 No
89 82.07 Outgoing, MCCB, 4 Pole, 250 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (lcs = 100% Icu) - 02 No
90 82.08 Three phase digital Voltmeter with range 0 to 500 Volts.
91 82.09 Three phase digital Ammeter with range 0 to 800 Amps with selector switich Make-Legrand
92 82.1 Complete wiring with copper cable, thimble etc.
93 83 Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cable including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :- \n 1 Each
94 83.01 Aluminium bus bar with proper colour code -04 No 150 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
95 83.02 Indicator Lamp-01 Set (Set of three) with control wiring.
96 83.03 Incoming, MCCB, 4 Pole, 100 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% lcu) - 01 No
97 83.04 Outgoing, MCCB, 3 Pole, 50 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% Icu) - 02 Nos \n\n
98 83.05 Outgoing MCB, SPN, 20 Amp, 230V-02 Nos
99 83.06 Outgoing, MCB, SPN, 6 amp, 230V, - 01 No
100 83.07 Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
101 84 Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :- \n 1 Each
102 84.01 Aluminium bus bar with proper colour code -04 Nos 150 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.\n
103 84.02 Indicator Lamp-01 Set (Set of three) with control wiring.
104 84.03 Incoming, MCCB, 4 Pole, 100 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% lcu) - 01 No.\n
105 84.04 Outgoing, MCCB, 3 Pole, 50 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% lcu) - 01
106 84.05 Outgoing, MCCB, 3 Pole, 40 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% lcu) - 01 No
107 84.06 Outgoing, MCB, TP, 10 amp, 415V, 10 KA - 01 No
108 84.07 Outgoing, MCB, SPN, 20 amp, 230V, - 01 No
109 84.08 Outgoing, MCB, SPN, 10 amp, 230V, - 01 No
110 84.09 Outgoing, MCB, SPN, 6 amp, 230V, - 05 Nos
111 84.1 Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.\n
112 85 Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :\n 1 Each
113 85.01 Aluminium bus bar with proper colour code -04 Nos 250 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
114 85.02 Indicator Lamp-01 Set (Set of three) with control wiring.
115 85.03 Incoming, MCCB, 4 Pole, 160 amp, 415V, 25 KA rupturing capacity, with adjustable settings 80% to 100 %, thermal Magnetic Release (Ics = 100% Icu) - 01 No
116 85.04 Outgoing, MCCB, 3 Pole, 50 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% lcu) - 03 Nos
117 85.05 Outgoing, MCB, TP, 16 amp, 415V, 10 KA - 01 No
118 85.06 Outgoing, MCB, SPN, 20 amp, 230V, - 01 No
119 85.07 Outgoing, MCB, SPN, 6 amp, 230V, - 01 No
120 85.08 Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
121 86 Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRl recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :- 1 Each
122 86.01 Aluminium bus bar with proper colour code -04 Nos 250 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
123 86.02 Indicator Lamp-01 Set (Set of three) with control wiring.
124 86.03 Incoming, MCCB, 4 Pole, 160 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %,Thermal Magnetic Release (Ics = 100% Icu) - 01 No\n
125 86.04 Outgoing, MCCB, 3 Pole, 100 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %,Thermal Magnetic Release(lcs = 100% lcu) - 01 No
126 86.05 Outgoing, MCCB, 3 Pole, 25 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% Icu) - 02 Nos
127 86.06 Outgoing, MCB, TP, 16 amp, 415V, 10 KA - 02 No
128 86.07 Outgoing, MCB, SPN, 20 amp, 230V, - 03 No
129 86.08 Outgoing, MCB, SPN, 6 amp, 230V, - 01 No
130 86.09 Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.\n
131 87 Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :- \n 1 Each
132 87.01 Aluminium bus bar with proper colour code -04 Nos 100 A cap, duly fixed on suitable and size of insulator complete as per OEM recommendations.
133 87.02 Indicator Lamp-01 Set (Set of three) with control wiring.
134 87.03 Incoming, MCCB, 4 Pole, 63 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %,Thermal Magnetic Release (Ics = 100% Icu) - 01
135 87.04 Outgoing, MCCB, 3 Pole, 50 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% lcu) - 01 Nos
136 87.05 Outgoing, MCB, TPN, 16 amp, 415V, 10 KA - 01 No ( For FP 5A)
137 87.06 Outgoing, MCB, SPN, 20 amp, 230V - 01 No
138 87.07 Outgoing, MCB, SPN, 6 amp, 230V - 08 Nos
139 87.08 Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
140 88 Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking .arrangement, 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :- 1 Each
141 88.01 Aluminium bus bar with proper colour code - 04 Nos 16 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
142 88.02 Indicator Lamp-01 Set (Set of three) with control wiring.
143 88.03 Incoming, MCB TPN, 16 amp, 415V, 10 KA - 01 No
144 88.04 Outgoing MCB SPN, 16 amp, 230V, - 01 No
145 88.05 Outgoing , MCB SPN, 6 amp, 230V, - 09 Nos
146 88.06 Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
147 89 Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :- \n 1 Each
148 89.01 Aluminium bus bar with proper colour code -04 Nos 80 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
149 89.02 Indicator Lamp-01 Set (Set of three) with control wiring.
150 89.03 Incoming, MCB, TPN, 50 amp, 415V, 16KA - 01 No
151 89.04 Outgoing, MCB, SPN, 6 amp, 230V, - 14 Nos (For 14 nos Water jet pumps. (Jet Pumps are to be provided by user)
152 90 Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :- 1 Each
153 90.01 Aluminium bus bar with proper colour code -04 Nos 400 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
154 90.02 Indicator Lamp-01 Set (Set of three) with control wiring.
155 90.03 Incoming, MCCB, 4 Pole, 250 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release, (Ics = 100% lcu) - 01 No
156 90.04 Outgoing, MCCB, 3 Pole, 100 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release, (lcs = 100% lcu) - 01 No (For STP) \n
157 90.05 Outgoing, MCCB, 3 Pole, 50 amp, 415V, 16 KA rupturing 80% to 100 %, Thermal Magnetic Release, (lcs = 100% lcu) - 01 No
158 90.06 Outgoing, MCCB, 3 Pole, 25 amp, 415V, 16 KA rupturing capacity , with adjustable settings -80% to 100 %, Thermal Magnetic Release, (Ics = 100% Icu) - 02 Nos
159 90.07 (g) Outgoing, MCCB, 3 Pole, 16 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release, (Ics = 100% Icu) - 02 Nos \n
160 90.08 Outgoing , MCB TP, 10 amp, 415V, 10 KA - 01 No
161 90.09 Outgoing, MCB, SPN, 20 amp, 230V, - 01 No
162 90.1 Outgoing, MCB, SPN, 6 amp, 230V, - 04 Nos
163 90.11 Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
164 91 Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :\n 1 Each
165 91.01 Aluminium bus bar with proper colour code -04 Nos 400 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
166 91.02 Indicator Lamp-01 Set (Set of three) with control wiring.
167 91.03 Incoming, MCCB, 4 Pole, 250 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release, (Ics = 100% Icu) - 01 No
168 91.04 Outgoing, MCCB, 3 Pole, 200 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release, (Ics = 100% Icu) - 01 No (For Adm Bldg)
169 91.05 Outgoing, MCCB, 3 Pole, 16 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release, (Ics = 100% Icu) - 01 No (For Trg Shed)
170 91.06 Outgoing, MCB, TP, 10 amp, 415V, 10 KA - 01 No
171 91.07 Outgoing, MCB, SPN, 20 amp, 230V, - 01 No
172 91.08 Outgoing, MCB, SPN, 6 amp, 230V, - 02Nos
173 91.09 Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.\n
174 92 S&F Post top lantern fittings complete with all accessories LED type 1x25 watt including electric connection complete from terminal box to light fittings in PVC conduit of suitable size having thickness not less than 1.8mm including suitable size junction box with 2 nos 50 amps Aluminium bus bar suitable to connect UG cable and grouting 40mm dia GI pipe light grade of length not less than 30cm each for fixing post top lantern fitting complete all as specified and directed by Engr In Charge.\n 6 Each
175 93 M&L earthing complete with galvanised steel earth plate eletrode 600mmx600mm and 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top prjgc, of the plate not less than 1.5m below normal ground level, connected to the Galvanise Iron earth lead 32mmx6mm (GI Strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , reinforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to feeder pillers and Transformer all as specified including testing on completion complete all as specified and directed. 32 Each
176 94 Earthing complete with G.l earth plate electrode 60 cm x 60 cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connecting to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth lead protected by provision of GI medium grade pipe 15mm bore including 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. 84 Each
177 95 S&F LED street light fitting complete with all accessories with rating 1X36 watt all as specified and directed by Engr-in-Charge. Make : Cat part No LTESSI36WLED of C&S or equivalent in makes of group-I\n(Note : GI Brackets shall be measured seperately under relevant item).\n 109 Each
178 96 M&L for Bracket for fixing of street light fittings bent to shape, made out of 40 mm dia GI pipe medium grade not less than 1.5 mtr long fixed with two sets of MS clamps made out of flat iron of size 50mmx6 mm fabricated to shape and fixed with nuts bolts and washers & two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge. \n(Note : MS clamps, nuts, bolt and washer shall be measured seperately under relevant item) 109 Each
179 97 S&F three core PVC insulated and FR PVC round sheathed, copper conductor 1100 volts grade cable of size 1.5 sqmm (multi stranded) complete all specified and directed by Engr-in-charge. 900 RM
180 98 S&F pole mounting junction box of size 300mmx200mmx100mm fabricated out of 2mm thick MS sheet, front openable door with hinges, duly painted with aluminium paint internally and externally over a coat red oxide primer suitable to house and including 02 Nos aluminium bus bar of 63 Amps capacity mounted on suitable insulators, one No MCB SP 6A mounted on dinrail, internally wired with suitable size of copper conductor cable, provision on bottom side for two cable entry holes including fixing with steel tubular poles with two Nos Fl clamps 25mmx3mm with nuts, bolts and washers complete and making connection with 1.5 sqmm copper conductor unsheathed FRLS PVC insulated 3 core from junction box to security lights fittings duly laid inside the streel tubular pole and bracket. complete all as specified.\nNote : 40 mm bore GI pipe light grade, MS clamps , nuts , bolts & washers and 3 core 1.5 sqmm cable, GI brackets will be measured separately.\n 109 Each
181 99 EXTERNAL WATER SUPPLY & ARBORICULRURE
182 100 Supply, laying, jointing and testing of DI (Ductile iron) Pipe 150 mm bore spigot and socketed type of Class K-7 conforming to IS 8329, with inside surface of centrifugally cement mortar lined, laid in trenches / on ground suitable for & including rubber gasket (Push-on) joint and jointing material complete all as specified and directed. \nNote :- Excavation and earth work will be measured and paid separately under relevent items. 20 RM
183 101 Ductile iron fittings confiorming to IS 9523 for spigot and socket pipes up to 150 mm bore such as bends (any type, radius and angle) tapes, any (straight, bend incresasing, decreasing or double socket etc) Tee pipes, single branch, 'Y' junction double branch, cross collers, caps and plug including push on joints complete all as specified and directed. \n 155 Kg
184 102 Construction of brick masonry valve pit of size 90cmx90cmx90cm (internal dimension of chamber) with brick work in cement mortar 1:4 including plastering internally and pointing externally as the work proceeds complete with MS sheet cover 3.15mm thick and angle iron frame 40mmX40mmX6mm with handle, locking arangement and painting with two coats of synthetic enamelled paint over a coat of red oxide primer on steel surfaces including earth work & excavation in any type of soil, disposal of surplus spoil not exceeding 50m concrete etc all as specified and shown on drawing. 11 Each Job
185 103 Construction of brick masonry valve pit of size 105cmx105cmx105cm (internal dimension of chamber) with brick work in cement mortar 1:4 including plastering internally and pointing externally as the work proceeds complete with MS sheet cover 3.15mm thick and angle iron frame 40mmX40mmX6mm with handle , locking arangement and painting with two coats of synthetic enamelled paint over a coat of red oxide primer on steel surfaces including earth work & excavation in any type of soil, disposal of surplus spoil not exceeding 50m concrete etc all as specified and shown on drawing. 2 Each Job
186 104 Gun metal, globe or gate valve (ISI marked), class 2 with iron wheel head, screwed both ends for 80mm bore iron pipe and fixed complete all as specified and as directed. 5 Each
187 105 Suuply, Fabrication & installation of header made out of heavy duty MS pipe 300 mm dia not less than 12 mm thick and not less than 3 mtr long duly painted and welded on both sides with MS plate having thickness not less than 12mm with suitable holes for incoming pipe 150mm dia - 01 No and 80mm dia - 05 Nos for out going pipes, The job includes welding 01 No 150mm dia MS pipe 600 mm long, heavy grade at one end and other end duly welded with MS flange having thickness not less than 10mm, duly holes drilled matching with the holes of sluice valve flange 150mm dia including sluice valve 01 No of 150mm dia conforming to IS 14846 with SS spindle and hand wheel and including 5 Nos MS pipe pieces 600mm long 80mm dia heavy grade welded at one end and other end duly welded with MS flange having thickness not less than 10mm duly holes drilled matching with the holes of sluice valve flange 80mm dia including sluice valves 04 Nos. of 80mm dia conforming to IS 14846 with SS spindle and hand wheel all as direced by Engineer in charge. \nThe job also includes fabrication of connecting piece made out of 80mm GI pipe medium grade 600mm long duly welded MS flange having thickness not less than 10mm duly holes drilled matching with the holes of flange of 80mm dia sluice valve at one end and other end threaded for cotinuous laying of GI pipes-03 Nos. and fabrication of connecting piece made out of 50mm dia GI pipe medium grade 600mm long duly welded MS flange having thickness not less than 10mm duly holes drilled matchng with the holes of flange of 80mm dia sluice valve at one end and other end threaded for continuous laying of GI pipes -02 Nos.\n 1 Each Job
188 105.01 Note : Header shall be placed above ground level on PCC block of size 2m x 1.2m x 0.8m built in PCC 1:3:6, type C-2 all as directed by the Engineer in charge. Rate of PCC block shall deemed to be included in this item.\n
189 106 Cutting of existing DI Pipe line 150mm dia, (two cuts in position) by any means, inserting and including new DI Tee of size 150mmX150mmX150 mm dia for branch connection all as directed by Engr-in-charge. \nNote : CI/DI fittings, excavation and earth work, Lead joint/ Flanged joint etc shall be measured and paid seperately. 1 Each Job
190 107 Suuply, Fabrication & installation of header made out of heavy duty MS pipe 150 mm dia not less than 12 mm thick and not less than 1.5 mtr long duly painted and welded on both sides with MS plate having thickness not less than 12mm with suitable holes for incoming pipe 100mm dia - 01 No and 80mm dia - 03 Nos for out going pipes, The job includes welding 01 No 100mm dia MS pipe 600 mm long heavy grade at one end and other end duly welded with MS flange having thickness not less than 10mm, duly holes drilled matching with the holes of sluice valve flange 100mm dia including sluice valve 01 No, 100mm dia conforming to IS 14846 with SS spindle and hand wheel and including 3 Nos MS pipe pieces 600mm long, 80mm dia heavy grade welded at one end and other end duly welded with MS flange having thickness not less than 10mm duly holes drilled matching with the holes of sluice valve flange 80mm dia including sluice valves 03 Nos of 80mm dia conforming to IS 14846 with SS spindle and hand wheel all as directed by the engineer in charge. \nThe job also includes fabrication of & including connecting piece made out of 80mm GI Pipe medium grade, 600mm long duly welded MS flange having thickness not less than 10mm duly holes drilled matching with the holes of flange of 80mm dia sluice valve at one end and other end threaded for continious laying of GI/PPR pipes - 03 Nos \nNotes :- (a) Header shall be placed above ground level on PCC block built in PCC (1:3:6) type C2 of size 2mx1.2mx0.8 m all as directed. \n(b) The rate of the PCC block is included in this item only.\n(c) PPR pipes shall be measured and paid seperately under relevent items 1 Each Job
191 108 Supply, fixing, installation of Mono block pump set of capacity 2 HP suitable for 415 V, 3 phase system, Head 10 mtr, Discharge 720 LPM, all as specified and directed. 2 Each
192 109 Supply, fixing, installation of Heavy duty DOL starter type DX-P with robust, 4 pole contactor & LR1 D OLR in SS enclosure for 2 HP Mono block pump set, complete as per specified. 2 Each
193 110 Supply and fixing of PVC insulated cable with copper conductor 1.1 KV of size 2.5 Sqmm complete with thimbling and providing cable connections all as directed. 60 RM
194 111 HOT WATER SUPPLY
195 112 Supply, installation and testing water heater storage type (Geyser) of capacity 25 litres, Five star rating of BEE complete, single phase 240 volts 50 Hz with copper inner tank, including necessary electrical & water connections fixed on wall with suitable nut & bolts including grouting in PCC 1:2:4 type B-I using 20mm graded crushed stone aggregate with 02 Nos of PVC flexible pipe for connection (hot & cold supply) with suitable size of nuts complete all as specified & directed.. 4 Each
196 113 Supply, installation, testing and commissioning of solar water heating system with ETC TECHONOLOGY of capacity 200 LPD with electric backup as per recommendations of manufacturer suitable for single phase 220 volts AC supply complete with ETC type collectors , HOT water tanks , Tank Stands etc with the following specifications :- \n(a) COLLECTOR ETC type with nos, size, level of vaccum transmittance of cover glass tubes, reflectance of glass tubes, absorbance of glass tubes, type of coating and reflectance of coating as recommended by manufacturer having wind resistance upto 100 km, with freezing resistance minus 20 degrees C heating up coefficent 240 degrees C having average thermal efficiency 58.76% and maximum rise in temp 53.04 deg C without night losses fixed at angle of inclination from horizontal, as per recommendations of manufacturer. \n(b) HOT WATER TANK : Hot water tank of 100 Itrs capacity made out of stainless steel sheet not less than 0.5mm thick duly insulated with puff insulation 50mm thick having density not less than 36 kgs having thermal conductivity 0.29m/K duly covered with PPGI cladding fixed with temperature gauge, inlet and outlet valves of suitabvle size duly installed on staging fabricated out of MS angle of appropriate size as recommended by manufacturer duly fixed properly and painted with two coats of anti corrosive paint over a coat of red oxide primer. \n(c) MAKE : Make of Solar system Sun Magic/BipinIndustries/Tata BP Solar/BORO Solar/INTERSOLAR\nNOTE:- PCC/Foundation work as recommended by the manufacturer will be included in the rate quoted for this work. 4 Each
197 114 All as per srl item No 113 here in above but Solar water heating system of 300 LPD capacity with hot water tank 300 litres capacity duly insulated and PPGI cladding inciuding electric backup as per recommendations of manufacturer. \nNOTE (for srl item No 113 & 114)\n(a) MS staging, puff insulated water storage tank, Hot water and cold water pipe insulation to pipe and valves to be measured and paid separately. \n(b) Any other items required for sucessful operation of system is deemed to be included in the rates quoted for above items 1 Each
198 115 SEWAGE TREATMENT PLANT (STP)
199 116 Designing, Construction, Installation and Commissioning STP (MBBR based) of capacity 340 cumday with Tertiary treatment, providing, constructing, hydraulic testing, commissioning and giving satisfactory trials of STP consisting of Inlet chamber (RCC), Fine bar Screen chamber (manual), RCC with steel screen, Oil & Grease Remover (RCC), Grit separator, Equalization Tanks, Air Grid for Equalization Tanks, Feed Pumps, Moving Bed Bio Reactor(s) with plastic media (of appropriate density, size and quantity to keep very high MLSS > 15,000 mg/lit), Air Blowers for MBBR, Tube Settler assembly, Sludge Drying Bed of appropriate size, Chlorine Dozing System, Chlorine contact tank, Foundation for all E/M equipments, Associated piping work with required valves, gates, drains, pathways, boundrywall/fencing gate, strom water drain , approach road , street lights, filter feed tanks of RCC, filter feed pumps , dual media filter, activated carbon filter , treated water tank in RCC for tertiary treatmnet including necessary chemical required for trial run and sucessful commissioning of plant , Electrical control Panel with interconnected cables , spare parts for 2 years of operation etc complete with all involved civil,electrical, digital and mechinacal works as per detailed specifications for civil electrical and mechanical components complete as per manufacturer/Tenderar design.\nNote :- (a) The rates includes the cost of trial run for three months from the date of completion.\n(b) Grease, Oil, Sodium hypo chloride, chlorine gas, granuals, bleaching powder and any other chemical required for smooth functioning of STP during the trial run shall deemed to be included in the quoted rates\n 1 Each
200 117 Supply and installation of ON LOAD change over switch 415 V in sheet metal enclosures 4 pole of capacity 125 Amps all as directed by Engineer in charge. 1 Each
201 118 Supply, installation, commissioning and testing of Diesel engine driven Water cooled generating set of capacity 50 KVA, 415 volts, BHP as per manufacture recommendation, AC supply, 50 Hz, 3 phase 4 wire, 0.8 PF at NTP, speed 1500 RPM at Jammu mounted on common base frame with flexible coupling and meeting the requirement of IS-4722/BIS specification with CPCB approved acoustic enclosures fabricated out of CRCA sheets as per manufacture recommendation. Sound proofing of enclosures is done with high quality foam conforming to IS-8183 for 75 dBT 01 metre complete including PCC foundation in all respect as per norms of OEM.\nMake: Kirloskar Oil Engines/ Cummins/ Greaves Ltd/ Ashok Leyland/ Mahindra & Mahindra / Ruston/Cater pillar 1 Each
202 118.01 DIESEL ENGINE: Water cooled diesel engine of adequate capacity at 1500 RPM generally in accordance with latest BIS/IS specification, 12 volts self starting including maintenance free battery of suitable capacity, charging dynamo/ alternator, air cleaner, diesel/ oil filters, complete in all respect. The engine shall be capable of taking 10% over load for one hour for every 12 hours running confirming to the environment (PROTECTION ACT 1986) (29 pf 1986) and as amended vide Gazette of India Notifications Part-II sections-III Sub Section (I) dated 12 Jul 2004.\n\n
203 118.02 ENGINE INSTRUMENT PANEL : All relevant information shall be displayed on a complete panel for easy monitoring of lubricant, oil pressure, battery charging, ammeter, hours meter, startin switch, etc.\n
204 118.03 FUEL TANK : In built fuel tank of adequate capacity for 12 hours running with stop cock, drain plug as per recommendation of OEM\n
205 118.04 ALTERNATOR : 50 KVA at NTP at Jammu Military Stn, 3 Phase, 50 Hz, 415 volts, AC supply, 0.3 PF at 1500 RPM, this shall be self excited screen protected and drip proof type brushless, conforming to relevant IS/BIS code as per latest manufacturing schedule.
206 118.05 CONTROL PANEL : The standard control panel shall be built in acoustic enclosures with the following accessories complete wired with suitable size of copper cable:- \n(i) MCCB of suitable capacity with over load and short circuit protection. \n(ii) Digital Ammeter. \niii) Digital voltmeter. \n(iv) One set of indicating LED lamps RYB and fuses. \n(v) Frequency meter, RPM meter, Hour meter, Fuel level indicator. \n(vi) KWH meter of suitable capacity digital type for 3 phase 415 volt AC supply and for unbalanced load \n(vii) Water temperature gauge, oil pressure gauge. \nNote : The Gen set must be affixed with label meeting the following requirement (The label shall be durable and legible) \n(a) Name and address of the engine manufacturer. \n(b) Statement that this engine conforms to the environment (PROTECTION) \n(c) Type and approval certificate number. \n(d Date of manufacturing of Gen set.
207 118.06 Acoustic enclosure: Acoustic enclosure should be as per manifucturer recommendation. The walls of enclosures will be insulated to get 75 dba at 1 metre sound leveled as recommended by ministry of environment and forest. The enclosure shall have following provisions :\n(i) Fitting arrangement \n(ii) Point for neutral and bod earthin iii Fuel drain \n(iv) Lub oil drainage \n(v) Air breather \n(vi) Easy stop push button \n(vii) Panel meter viewinG window\n(viii) Canopy light as per OEM recommendations\n\nNote: (i) DG set should be sound proof as per latest policy\n (ii) First filling of Engine oil and Fuel etc should be arranged by contractor for testing \n
208 119 Designing, Installation, commissioning and testing of Non clog submersible pump with chrome steel impeller and cutter to pass 40mm-80mm size particles with suitable capacity of motor including guide wire and lifting chain, suitable size of discharge pipes from pump at collection sump No 1 to collection sump No 2 with all fittings, NRVs and suitable capacity of submersible pump starter and connected items required for smooth functioning of pump set all as directed by Engr-in-charge.\nNote :- The rate for this items shall deamed to be inclusive of any other items reqd for installation and proper functioning of pump sets as per ground requriment. 2 Each
209 120 Sump well cum pump house 401 to 500 Cum/day of 8 metre overall depth and dia 3m internally with IL upto 4 m, designing and constructing RCC sumps in M-30 design mix of required capacity including excavation in all type of soil strata, foundation concrete, container walls, bottom slab, top RCC roof slab with CI manhole covers, internal plaster and water proofing as specified including epoxy paint inside, refilling of earth and disposal of surplus earth within 50m lead including all piping connctions, valves, internal electrification, MS ladder, ventilation shaft, BB chambers with 5m of outer wall of tannk complete including test for water tightness and hydralic functioning, top roof as per zonal specification all as directed by Engr-in-charge. 1 Each
210 121 ROAD BARRIER & ROAD FURNITURE :
211 122 Supply installation, commissioning & testing of Electrically operated Security Road Barrier consisting of aluminium boom of length 6 mtrs , counter balance channels and weights, boom support , control switch gear push button unit for control of barrier with VFD control system for multispeed control all as specified and directed with following specifications : 1 Each
212 122.01 Drive Mechanism : (i) Consisting of max. 1/4 H.P heidz India make or similar reversible motor, coupled through a Timing Belt (No V Belting) to be oil/gel filled and sealed type composite gear drive unit with internal locking feature, friction clutch, circuit controller, with Jai Balaji roller type Limit Switches, hand crank arrangement for manual operation at time of power failure, control switchgear with Schnieder/Telemechanique contactors, Schnieder Motor Rating MCB, electronic circuit, Phoenix terminals etc. complete as required\n(ii) System operates satisfactorily within voltage range of 200-250V, 50 Hz AC Option also available with multi speed VFD Drive Unit for speed control & smoother operation.\n(iii) Operating time (opening/closing) within 6/7sec or as per manufacturer for boom length up to 6m\n
213 122.04 Aluminium Boom: Fabricated from suitable thickness of 3, 2.5 & 1.9 mm aluminum sheets die pressed to form tapering channels. Two such channels joined flange with riveted joint plates to form a tapering box section. Special stiffening bends provided in web of channels to increase the strength. The size of the box section at the larger end min. 180 x 180mm.\n
214 122.05 COUNTERBALANCE CHANNELS & WEIGHTS \nFor fixing the boom to the mechanism and for counterbalancing the weight of the boom. These should be of M.S.\n
215 122.06 BOOM STAND for supporting the tip of the boom in its lowered position this should be of MS with suitable rubber pad.
216 122.07 PUSH BUTTON CONTROL UNIT For remote control of the barrier, consisting of 3 push buttons for raising, lowering & mid stopping
217 122.08 CABLING REQUIREMENTS \n(i) 4 core x 1.5 sq mm unarmored flexible control cable between push button unit & mechanism box (Barrier Machine). \n(ii) 3 core unarmored cable for 230 V AC 5 amp power supply to barrier (with earthing), from power point to mechanism box.
218 123 Preparation of new or previously treated surface and Painting lines, dashes, arrows, letters etc on road pavement (Bituminous surfaces) and the like using thermoplastic paint with 8% glass beads using special applicator machine with heating arrangement upto 160ºC with road marking paint of white or golden yellow complete all as directed by Engr-in-Charge. Make : Asian/ STP Ltd/ Automat/ 3M. 1600 Sqm
219 124 Road sign boards with legs of size 1200mmx600mm made out of 18 \ngauge (1.25mm) thick CRCA steel sheet duly framed in 32mm sq MS pipe of 16 gauge sheet provided with 25 mm Sq pipe hold fast. Board stove enamenaled and baked 1200 C to make it all weather resistant . Board laminated on both sides with reflective sheets, computer cut letters, sign and as directed by the Engineer in charge. Sign board to have 12mm reflective boarder all around the board supported with bolts, over a pair of legs made out of 47mm Sq MS pipe of 16 gauge sheet of length 3mtr each duly painted with black and white 1st grade synthetic enamel paint over a coal of red oxide metal primer complete all as spedified and directed. Make : Greenlite / Dark eye / 3M / Avery Dennison as approved by GE. 15 Each
220 125 Note: The schedule of credit has been attached in tender in Pdf format and amount of credit schedule i.e. Rs 5908673.65 shall be deducted from the total amount of BOQ to arrive at the contract sum.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail