Completion Of Incomplete Work For Provn Of Otm Accn For 314 Fd Hospital And 20 Bedded Section Hospital At Clement Town Dehradun, Dehradun-Uttarakhand

Military Engineer Services-MES has published Completion Of Incomplete Work For Provn Of Otm Accn For 314 Fd Hospital And 20 Bedded Section Hospital At Clement Town Dehradun. Submission Date for this Tender is 16-06-2020. Building Work Tenders in Dehradun Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

24043787
Corrigendum : Completion Of Incomplete Work For Provn Of Otm Accn For 314 Fd Hospital And 20 Bedded Section Hospital At Clement Town Dehradun
Open Tender
Indian
Uttarakhand
Dehradun
16-06-2020

Tender Details

Completion Of Incomplete Work For Provn Of Otm Accn For 314 Fd Hospital And 20 Bedded Section Hospital At Clement Town Dehradun

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Apr-2020 Amendment to critical dates Date 06-05-2020
2 22-Apr-2020 Date Corrigendum Date 18-05-2020
3 04-May-2020 Amendment to imp dates Date 09-06-2020
4 27-May-2020 amendment to tender doc Other 09-06-2020
5 09-Jun-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-06-2020

Key Value

Document Fees
INR 3000 /-
EMD
INR 650000.0 /-
Tender Value
INR 6.50 Crore /-

BOQ Items

Name of Work : COMPLETION OF INCOMPLETE WORK FOR PROVN OF OTM ACCN FOR 314 FD HOSPITAL & 20 BEDDED SECTION HOSPITAL AT CLEMENT TOWN DEHRADUN
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SCHEDULE 'A' PART-I (BUILDING WORK)\n
2 1.01 Completion of incomplete work for construction of block of Single living accn (single storeyed) for Captain room, garage & ramps all as shown on drawings and as specified . 1 Each Block
3 1.02 Completion of incomplete work for construction of block of Single living JCOs accn (Double storeyed) complete including scooter shed as shown on drawings and as specified . 1 Each Block
4 1.03 Completion of incomplete work for Construction of block of Single living accn for Hav/ORs (Double storeyed) complete including BAGGAGE room all as shown on drawings and as specified . 1 Each Block
5 1.04 Completion of incomplete work for Construction of block of Accn for JCOs Mess (16-20) (single storeyed) complete all as shown on drawings and as specified . 1 Each Block
6 1.05 Completion of incomplete work for Construction of block of Accn for cook house &Dinning Hall (single storeyed) complete including ramp all as shown on drawings and as specified . 1 Each Block
7 1.06 Completion of incomplete work for Construction of block of Officer mess for 19 Officer(11-18) (Double storeyed) complete including ramp all as shown on drawings and as specified . 1 Each Block
8 1.07 Construction of block of Servant Quaters for Offr Mess(Double storeyed) complete including ramp all as shown on drawings and as specified . 1 Each Block
9 1.08 Completion of incomplete work for Construction of Open garrage with apron for 06 nos car complete including ramp all as shown on drawings and as specified . (Refer Drg No BZ/DDN/679 and its series). 1 Each
10 1.09 Completion of incomplete work for Construction of block of Guard house (100-350) (single storeyed) complete including ramp all as shown on drawings and as specified . (Refer Drg No BZ/DDN/680 and its series). 1 Each Block
11 1.1 Completion of incomplete work for Construction of Administration Accomadation (Double storeyed)(central corridoor) complete including ramp all as shown on drawings and as specified . (Refer Drg No BZ/DDN/681 and its series). 1 Each Block
12 1.11 Completion of incomplete work for Construction of Parking Shed(Open)for Adm office (9 car) complete including ramp all as shown on drawings and as specified . 1 Each
13 1.12 Completion of incomplete work for Construction of Parking Shed(Open)for Adm office (10 car) complete including ramp all as shown on drawings and as specified . 1 Each
14 1.13 Completion of incomplete work for Construction of Covered accn for Vehicle complete including ramp all as shown on drawings and as specified . \n(a) 38 vehicle of one block (b) 3 vehicle of one block\n(Refer Drg No BZ/DDN/684 and its series). 1 Each
15 1.14 Completion of incomplete work for Construction of Cycle cum scooter shed (36 nos) for Adm Office complete including ramp all as shown on drawings and as specified . 1 Each
16 1.15 Completion of incomplete work for Construction of block of 04 Repair Bay including ramps & aprons etc complete all as shown on drawings and as specified . (Refer Drg No BZ/DDN/686 and its series). 1 Each
17 1.16 Completion of incomplete work for Construction of MT Storage and Battery charging shops including ramp etc complete all as shown on drawings and as specified 1 Each Block
18 1.17 Completion of incomplete work for Construction of Central MI Room (strength 5001-10000) complete including ramp all as shown on drawings and as specified . (Refer Drg No BZ/DDN/688 and its series). 1 Each Block
19 1.18 Completion of incomplete work for Construction of garage for cycle cum scooter/Ambulance including ramps etc complete all as shown on drawings and as specified (Refer Drg No BZ/DDN/689 and its series). 1 Each
20 1.19 Completion of incomplete work for Construction of Education Building and computer room (Double storeyed)) complete all as shown on drawings and as specified . 1 Each Block
21 1.2 Completion of incomplete work for Construction of OR Institute up to 500 men complete including ramp all as shown on drawings and as specified . (Refer Drg No BZ/DDN/691 and its series). 1 Each Block
22 1.21 Completion of incomplete work for Construction of Football and Hockey ground complete including all as shown on drawings and as specified . 1 Each
23 1.22 Completion of incomplete work for Construction of basketball court complete including all as shown on drawings and as specified . 1 Each Block
24 1.23 Completion of incomplete work for Construction of Volley ball court omplete including all as shown on drawings and as specified . 1 Each
25 1.24 Completion of incomplete work for Construction of Specialiased Scales of Field Ambulances all as shown on drawing and as specified 1 Each Block
26 1.25 Completion of incomplete work for Construction of Dryingroom & Ironing rooms complete all as shown on drawings and as specified 1 Each Block
27 1.26 Completion of incomplete work for Construction of block for Religious Institute Hall (small unit) complete including ramp all as shown on drawings and as specified . (Refer Drg No BZ/DDN/694 and its series). 1 Each Block
28 1.27 Completion of incomplete work for Consruction of Storage Accomamodation including ramp etc complete all as shown on drawing and as specified. 1 Each Block
29 1.28 Completion of incomplete work for Consruction of Tradesman shop etc complete all as shown on drawing and as specified. 1 Each Block
30 1.29 Completion of incomplete work for Construction of Block for Oil fire Incinerator complete including plate form etc all as shown on drawings and as specified 1 Each Block
31 1.3 Completion of incomplete work for Construction of RCC Over head tank-30000 gallan including 21.4 meter height staging complete all as shown on drawings and as specified . 1 Each
32 1.31 Completion of incomplete work for Construction of block of 20 Bedded Hospital including ramp etc complete all as shown on drawings and as specified . 1 Each Block
33 1.32 Completion of incomplete work for Construction of block for SM Barrack for 10 ORs complete all as shown on drawings and as specified . 1 Each Block
34 1.33 Completion of incomplete work for Construction of Cook House for Hospital complete all as shown on drawings and as specified . 1 Each Block
35 1.34 Completion of incomplete work for Construction of Parking Shed) for Adm office for 2 car,10 scooter,&10cycles complete including ramp all as shown on drawings and as specified . 1 Each
36 2 Total amount of SCHEDULE 'A' PART-II A (INTERNAL WATER SUPPLY) (For details see Schedule 'A' Part-II-A in PDF folder) 1 Complete Sch 'A' Part-II-A
37 3 SCHEDULE 'A' PART-II B (INTERNAL WATER SUPPLY)
38 3.01 S&F, Elbow operated chromium plated fancy Bib tap cast copper alloy with crutch or butter fly handle, screwed down, for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed. Make - Jaguar cat no FLR- 5033B of Medi series or equivalent as approved. 3 Each
39 3.02 S&F brass CP central hole wash hand basin mixerw/o PUW with 450 mm SS flexible hose sreewed down high pressure screwed for iron pipe etc complete all as specified and directed. Make Hindware cat no F-200014/Jaquar cat no CON 167B equivalent make as specified 28 Each
40 3.03 S&F 15 mm dia brass CP sink mixer with swivel spout wall mounted for mixing hot & cold water screwed down for iron pipe and fixed all as specified and directed. Make Hindware cat no F-200023/Jaquar cat no CON 309 or equivalent make as specified 7 Each
41 3.04 S&F15 mm dia brass CP WALL mixer for over head shower with 115 mm long bend pipe &wall flange for mixing hot & cold water screwed down for iron pipe and fixed all as specified and directed. Make Hindware cat no F-200020/Jaguar cat no CON 273UPR or equivalent make as specified 13 Each
42 3.05 S&F,brass ,CP Bib tap long body Fancy type cast copper alloy with crutch or butter fly handle, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket with wall flange complete all as specified and directed. Make Hindware cat no F-200001/Jaguar cat no CON 107 or euivlent make as specified 39 Each
43 3.06 S&F,fancy type brass angle cock Chromium plated , screwed both ends suitable for 15mm bore GI pipe complete all as specified and directed, Make Hindware cat no F-200005/Jaquar cat no CON 053or euivlent make as specified 94 Each
44 3.07 S&F,fancy type brass stop valve Chromium plated , screwed both ends suitable for 15mm bore GI pipe complete all as specified and directed, Make Hindware cat no F-200007/Jaquar cat no CON 069 or equivalent make as specified 71 Each
45 3.08 S&F brass chromium plated shower rose Fancy type , 125mm dia with or without swivel joints, incl shower arm fixing to 15mm bore pipe or union complete all as specified.. Make Hindware cat no F-880011 orequivalent make as specified 14 Each
46 4 Total amount of SCHEDULE 'A' PART-III-A (INTERNAL ELECTRIFICATION) (For details see Schedule 'A' Part-III-A in PDF folder) 1 Complete Sch 'A' Part-III-A
47 5 SCHEDULE 'A' PART-III-B (INTERNAL ELECTRIFICATION)\n
48 5.01 M & L for Point wiring with 1.5 Sq mm single core, multi stranded PVC insulated, unsheathed copper conductor cable FRLS and including rigid non metallic concealed conduit 20 mm dia or higher medium grade ISI marked complete with all conduit accessories / fittings and sunk CI/pressed steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, concealed in wall including earth wire continuous of PVC insulated, unsheathed 1.5 Sq mm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic laminated sheet screwed with brass screws, cup washers complete all as specified and directed for the following :-
49 5.02 (a) One light point controlled by one way switch 5/6 Amps 735 Per Point
50 5.03 (b) One fan point controlled by one way switch 5/6 Amps 207 Per Point
51 5.04 (c) One Exhaust Fan point controlled by one way switch 5/6 Amps 15 Per Point
52 5.05 (d) One Bell point controlled by one way switch 5/6 Amps 13 Per Point
53 5.06 (e) 6 Amps 3 Pin Socket on same board controlled by one switch 59 Per Point
54 5.07 (f) 6 amps 3 pin socket on independent board controlled by one switch 208 Per Point
55 5.08 (g) One light point controlled by 2 way switch 5/6 Amps 14 Per Point
56 5.09 Note : Switch, socket outlet etc will be paid and measured separately.
57 5.1 M & L for Point wiring with 2.5 Sq mm single core, multi stranded PVC insulated, unsheathed copper conductor cable FRLS and including rigid non metallic concealed conduit 20 mm dia or higher medium grade ISI marked complete with all conduit accessories / fittings and sunk CI/pressed steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, concealed in wall including earth wire continuous of PVC insulated, unsheathed 1.5 Sq mm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic laminated sheet screwed with brass screws, cup washers complete all as specified and directed for the following :- Note.- Switch & Socket Shall be measured and paid Separately. 28 Per Point
58 5.11 S&F florescent T/light 1 x 28 Watt fitting box type complete with all accessories such as electronic choke condenser and F/Tube rod 28 watt 230 volt fixed on wall/ceiling connected with 3 core 14/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified. CAT Part No LHIT 12128032 of Havells or as approved equivalent make 352 Each
59 5.12 S&F Fluorescent T/Light fitting decorative box with aluminum reflector complete with electronic choke 2 x 28W HPF and connected with 14/0.0076 insulated copper wire from ceiling rose to fitting connector fixed with conduit bell mouth coupler, 2 x 28 W T/Light fitting complete with all accessories incl F/Tube rod all as specified CAT Part No LHIT 1228033 of Havells or as approved equivalent make 176 Each
60 5.13 S&F Ceiling fitting complete with all accessories such as electronic choke and CFL 3 x 36 W , 230V fixed with on ceiling/roof connected with 3 core 14/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified CAT Part No LHCL 01336425 Make Havells/equivalent 58 Each
61 5.14 S&F Ceiling fitting 1 x 20 W complete with all accessories such as electronic choke, and CFL of 20W 230V fixed on ceiling connected with 3 core 14/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified CAT Part No LHKC 071120099 of Havells or as approved equivalent make 166 Each
62 5.15 Supply & fixing security light fitting suitable for 2 x 11 watt CFL and including 2 Nos CFL lamp of 11 watt complete with M&L GI pipe mounting bracket of size 25/32 mm dia and 1.20 m long fixed to wall with and including nut, bolts and GI clamps of size 50 x 6 mm as required including two coats of synthetic enameled paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed. Make – Bajaj Cat Pt No. BJSLF 211 DD , or equivalent. 189 Each
63 5.16 S&F mirror light fitting 2 x 18 W complete with all accessories such as electronic choke, and CFL 2 Nos of 18W 230 V fixed on wall connected with 3 core 14/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified CAT Part No BCRL 218 CFL of Make Havellsor equivalent. 25 Each
64 5.17 M & L for Sub main wiring with four single core,16 Sqmm, PVC insulated PVC unsheathed stranded copper conductor cable FRLS and including PVC conduit, 25 mm or higher dia, ISI marked, medium grade complete with all conduit accessories/ fittings including extension of earth wire with 6 Sqmm single core PVC insulated, unsheathed copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed. 1000 RM
65 5.18 M & L for Sub main wiring with four single core,10 Sqmm, PVC insulated PVC unsheathed stranded copper conductor cable FRLS and including PVC conduit, 25 mm or higher dia, ISI marked, medium grade complete with all conduit accessories/ fittings including extension of earth wire with 4Sqmm single core PVC insulated, unsheathed copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed. 830 RM
66 5.19 M & L for Sub main wiring with two single core,16 Sqmm, PVC insulated PVC unsheathed stranded copper conductor cable FRLS and including PVC conduit, 20 mm or higher dia, ISI marked, medium grade complete with all conduit accessories/ fittings including extension of earth wire with 6 Sqmm single core PVC insulated, unsheathed copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed. 7065.5 RM
67 5.2 -do all as per Item No 5.19 but two 10 sqmm with 4.0 sqmm earthwire 5223 RM
68 5.21 -do all as per Item No 5.19 but two 6 sqmm with 4.00 sqmm earthwire 3807.3 RM
69 5.22 M & L for Tripple pole and neutral DB’s, 8 way suitable for mounting MCBs/ Isolators as outgoing and incoming MCCB 125 Amp TP complete vertical load line type including all fixing materials/accessories for double door DB, all as specified and directed. Note : Incoming MCCB and outgoing MCB SP/TP will be measured and paid seperately. 7 Each
70 5.23 M & L for Distribution board single pole and neutral 12way, 240 volts, double door type suitable for mounting incoming and outgoing MCB’s double pole/single pole, 4/8 Nos respectively out going MCB’s. all as specified and directed Note : Incoming and outgoing MCB SP/TP will be measured and paid seperataely. 8 Each
71 5.24 -do all as per Item No 5.23 but 8 way 11 Each
72 5.25 -do all as per Item No 5.23 but 4 way 29 Each
73 5.26 S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps (for geyser) 22 Each
74 5.27 M & L for Miniature circuit breaker single pole with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistant moulding suitable for single phase circuit of 240 Volts and 6 to 32 Amps current rating ‘C’ series, 10 KA complete all as specified. 448 Each
75 5.28 S&F,Miniature circuit breaker triple pole and neutral with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistant moulding suitable for three phase circuit of 415Volts and 63 Amps , 10 KA complete all as specified. 13 Each
76 5.29 S&F,Miniature circuit breaker single pole and neutral (SPN) with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistant moulding suitable for single phase circuit of 240 Volts and 6 to32 Amps series, 10 KA complete all as specified. 311 Each
77 5.3 -do- all as per Item No 5.29 but 63 Amps 18 Each
78 5.31 S&F MCCB TP 415 Volts 125 Amps Cap, 25 KA fixed on load line vertical DB TPN. (Make : Legrand), and equivalent. 11 Each
79 5.32 S&F Ceiling fan 1200 sweep with regulater and completed with capistor canpy and down rod including flexible twincore copper (23/0.0076)with provision of ceiling rose/connector to fan all as specified 315 Each
80 5.33 S&F Ceiling fan 1400 sweep with regulater and completed with capistor canpy and down rod including flexible twincore copper (23/0.0076)with provision of ceiling rose/connector to fan all as specified. 12 Each
81 5.34 S&F only propeller type AC ventilating fans 300 mm sweep (Exhaust fan) with louver shutter complete including M&L for providing/cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/.0076 copper cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. Make- Usha/Havells. 44 Each
82 5.35 All as per item No. 5.34 hereinbefore but 450 mm sweeps. 5 Each
83 5.36 Numbering of all fans / light fitting / geysers / Exhaust fans with points 525 Each
84 5.37 S&F Blanking plate 2 Each
85 5.38 S&F, call bell AC 240 V single pole 18 Each
86 5.39 S&F wall light fittings fancy type 1 x 15W, 230 volt incl 15 watt Fixed on wall and connected complete all as specified CAT Part No MBBS -802 Make Mepro or equivalent etc all as specified and directed. 90 Each
87 5.4 Earthing complete with galvanized mild steel earth plate (electrode) 600 x 600 x 6.00 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 4 mm dia GI wire as earth wire moulded and riveted to earth plate at one end and connected to main switch/control switch of the building at another end, GI earth wire incased in and including 15 mm dia GI ‘light grade’ pipe from upper end of earth plate uopto main switch/control of the building including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of earth plate, CI funnel with wire mesh fixed on water pipe and provision of PCC chamber and RCC pit cover with lifting handle, excavation, earth work including laying the GI pipe concealed in floor /wall all as described in electrical plate No 3 of SSR Part I. 36 Each
88 5.41 S&F propeller type AC ventilating fans 300 mm sweep PVC Body (Exhaust fan) with louver shutter complete including M&L for providing/cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core14/0.0060 copper cable rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed Make-Usha / Havells, 10 Each
89 5.42 M&L for point wiring with 2.5 Sqmm single core, PVC insulated with multi stranded unsheathed copper conductor cable (FRLS) in and including rigid non-metallic concealed conduit 20mm dia, medium grade ISI marked complete with all conduit accessories/ fittings controlled by modular type switch one way with metal box concealed in wall including continuous earth wire of PVC insulated, unsheathed 1.5 Sqmm solid copper conductor connected to all fittings, all as specified and directed
90 5.43 (a)One light point controlled by one, one way modular switch, 5/6 Amps 89 Per Point
91 5.44 (b)One fan point controlled by one, one way modular switch, 5/6 Amps 31 Per Point
92 5.45 (c)One Exhaust fan point controlled by one, one way modular switch, 5/6 Amps 7 Per Point
93 5.46 (d)6 Amps 3 pin modular socket on independent board controlled by one, one modular switch, 5/6 Amps 22 Per Point
94 5.47 M&L for point wiring with 2.5 Sqmm single core, PVC insulated with multi stranded unsheathed copper conductor cable (FRLS) in and including rigid non-metallic concealed conduit 20mm dia, medium grade ISI marked complete with all conduit accessories/ fittings controlled by modular type switch one way with metal box concealed in wall including continuous earth wire of PVC insulated, unsheathed 1.5 Sqmm solid copper conductor connected to all fittings, all as specified and directed 21 Per Point
95 6 SCHEDULE 'A' PART-IV (SITE CLEARANCE AND EARTHWORK\n
96 6.01 Excavation over areas exc. 3.0 m but n exc 4.50m deep and getting out in hard / dense soil complete all as specified and directed. 386.17 Cum
97 6.02 Surface excavation n.exc 30cm deep and averaging 15cms deep and getting out in soft/ loose soil complete all as specified and directed. 38438.2 Sqm
98 6.03 site clearance ,cleaning away grass,bush, saplings shrubs,brushwood undergrowth,roots and trees not exc 30cm girth and removing rubbish up to adistance of 50 mtrs out side Mdland surfaces dressing n exc 15cm in hard/dense complete all as specified and directed 7243.15 Sqm
99 6.04 Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed. 348.2 Cum
100 6.05 All as per item No 6.04 above but exc 1.5m and n exc 3.00 m 41.17 Cum
101 6.06 All as per item No 6.04 above but exc 3.00m and n exc 4.50 m 5 Cum
102 6.07 Removing excavated soil to a distance not exceeding 50 metres depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. 4751.27 Cum
103 6.08 Removing excavated soil to a distance exc 50 metre not exceeding 250metres depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. 7498.13 Cum
104 6.09 Forming embankment including raising (or lowering) earth spreading in layers n.exc 30 cm thick, watering ramming / rolling and finishing to required size, shape etc n.exc 1.5m high from base complete all as specified and directed.\n(Note : Surplus soil obtained from excavation vide various parts of Sch 'A' shall be used for forming embankment 4341.49 Cum
105 6.1 M&L for stone boulder pitching, grouted with cement and sand morter 1;6 etc complete all as specified and directed. 100 Cum
106 7 Total amount of SCHEDULE 'A' PART-V ( PROTECTIVE WORK) (For details see Schedule 'A' Part- V in PDF folder) 1 Complete Sch 'A' Part-V
107 8 Total amount of SCHEDULE 'A' PART-V A ( Hardstanding/Apron/washing Plateform/Parade ground) (For details see Schedule 'A' Part- V A in PDF folder) 1 Complete Sch 'A' Part-V A
108 9 Total amount of SCHEDULE 'A' PART-VI A ( ROAD, PATH & CULVERT) (For details see Schedule 'A' Part- V A in PDF folder) 1 Complete Sch 'A' Part-V A
109 10 SCHEDULE 'A' PART-VI B ( ROAD, PATH, & CULVERT)
110 10.01 M&L Applying thermoplastic reflective paint as in road marking of minium 2.50mm thick single coat of 100/150mm wide using HOT MARK thermo plastic paint (hot application) white golden yellow by indigenous modern prperty road marking machine as directed. 720 Sqm
111 10.02 Supply and fixing of 3 MUSA brand markers (cat eyes) made of non breakable polycarbonate with electronically welded primatic Retro reflecive in wet and dry condition with dust proof body complete all as specified and directed. 330 Each
112 10.03 M&L for 65mm thick Rubber moulded Glazed interlocking tiles laid dry over sand cushioning complete all as specified and directed 130.18 Sqm
113 10.04 S&F ABS/plastic of size speed breaker 250x750x75 mm block black and yellow reflectors on both sides incl installaltion with application of Epoxy and spikes for Anchoring complete all as specified and as directed 100 RM
114 10.05 S&F Delinators post of 60cm height from ground level, black or red colour made of 16guage 48mm dia MS round pipe heavy duty incl two coats of powder coated black colour paint over one coat of primer with three reflective device all as per MOST & IRC specification and as directed. 50 Each
115 10.06 Provn of RCC hume pipe culvert class NP-2 610mm ,internal dia 9.40 m long (in between parapet ) including excavation work in ordinary soil, PCC in foundation ,RCC hume pipe, brick work in CM 1:4 ,PCC coping ,cement plaster and white wash complete all as specified and directed. 4 Each
116 10.07 Provn of RCC hume pipe culvert class NP-2 450 mm ,internal dia 7.40 m long (in between parapet ) including excavation work in ordinary soil, PCC in foundation ,RCC hume pipe, brick work in CM 1:4 ,PCC coping ,cement plaster and white wash complete all as specified and directed. 10 Each
117 10.08 Provn of RCC hume pipe culvert class NP-2 450 mm ,internal dia 9.40 m long (in between parapet ) including excavation work in ordinary soil, PCC in foundation ,RCC hume pipe, brick work in CM 1:4 ,PCC coping ,cement plaster and white wash complete all as specified and directed. 8 Each
118 11 Total amount of SCHEDULE 'A' PART-VII A (SEWAGE DISPOSAL) (For details see Schedule 'A' Part-VII A in PDF folder) 1 Complete Sch 'A' Part-VII A
119 12 Total amount of SCHEDULE 'A' PART-VIII (AREA DRAINAGE) (For details see Schedule 'A' Part-VIII in PDF folder) 1 Complete Sch 'A' Part-VIII
120 13 SCHEDULE 'A' PART-IXA (BOUNDARY WALL AND GATE) (For details see Schedule 'A' Part-IX A in PDF folder) 1 Complete Sch 'A' Part-IXA
121 14 SCHEDULE 'A' PART-IX B (BOUNDARY WALL AND GATE)
122 14.01 Completion of incomplete work for construction of Steel gate 5.50mtr wide (clear distance between RCC pillar toRCC pillar) 2.45 mtr high including RCC pillars,excavation and eartwork in any type of soil , PCC in foundation ,PCC block , steel work and painting etc complete all as specified and shown on drawing.\nNote : 50 % work of all 7 gates has been completed by previous contractor. 7 Nos
123 15 SCHEDULE 'A' PART-XA (EXTERNAL WATER SUPPLY) (For details see Schedule 'A' Part-X A in PDF folder) 1 Complete Sch 'A' Part-XA
124 16 SCHEDULE 'A' PART-X B (EXTERNAL WATER SUPPLY)
125 16.01 M&L for providing lowering in trenches, laying and jointing ductile iron pipe (K-9), socket and spigot end, as per specifications (IS-8329) with internal cement mortar lining and external bitumen coating for portable water supply with rubber ring joints, including cost of rubber rings as per IS:5382 (1985), giving satisfactory hydraulic field testing and commissioning as per Technical specification etc complete of 100mm dia complete all as specified and directed. 110 RM
126 16.02 M&L for providing lowering in trenches, laying and jointing ductile iron pipe (K-7), socket and spigot end, as per specifications (IS-8329) with internal cement mortar lining and external bitumen coating for portable water supply with rubber ring joints, including cost of rubber rings as per IS:5382 (1985), giving satisfactory hydraulic field testing and commissioning as per Technical specification etc complete of 150mm dia complete all as specified and directed. 450 RM
127 16.03 M&L for providing lowering in trenches, laying and jointing ductile iron pipe (K-9), socket and spigot end, as per specifications (IS-8329) with internal cement mortar lining and external bitumen coating for portable water supply with rubber ring joints, including cost of rubber rings as per IS:5382 (1985), giving satisfactory hydraulic field testing and commissioning as per Technical specification etc complete of 200mm dia complete all as specified and directed. 480 RM
128 16.04 Supply,laying in trenches and testing Ms heavy duty ERW Steel pipe 5.40mm thick welded in any shape, and making bends etc including flange 10mmthick both end including two coat of rubber black paint in outer all complete with fittings etc for following sizes complete all as specified and directed.
129 16.05 150mm dia 30 RM
130 16.06 200 mm dia 20 RM
131 16.07 Supply,laying and testing of cast iron sluice valves of class PN1.6, conforming to relevent IS 14846 including , flanged ends, drilled having stainless steel spindle(ISI Marked) with cast iron wheel at top complete with nut bolts, washer and rubber gasket complete all as specified for following:-
132 16.08 200mm dia 3 Each
133 16.09 150 mm dia 6 Each
134 16.1 100mm dia 3 Each
135 16.11 80 mm dia 3 Each
136 16.12 S&F valves reflux 200mm dia with by pass arrangement fixed in the pipe line including fixing accessories complete all as specified and directed. 1 Each
137 16.13 S&F cast iron air realease valves with two air outlets, 80mm dia bore and fixing up in cast iron water supply mains including all fixing arrangement complete all as specified and directed. 1 Each
138 16.14 M&L for construction of brick masonery valve pit of size 1000x1000x1000 mm.(Internal dimensions) with brick work of sub class 'B' old size bricks built in cement mortar 1:4 and 10mm thick rendering on internal and exposed external surfaces and including 40x40x6 mm mild steel angle frame 3.15 mm thick mild steel sheet cover in two nos shutters with handle and locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate make Navtal including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawing and as directed 3 Each
139 16.15 M&L for construction of brick masonery valve pit of size 750x750x750 mm.(Internal dimensions) with brick work of sub class 'B' old size bricks built in cement mortar 1:4 and 10mm thick rendering on internal and exposed external surfaces and including 40x40x6 mm mild steel angle frame 3.15 mm thick mild steel sheet cover in two nos shutters with handle and locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate make Navtal including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawing and as directed \n\nNote :- All excavation & earth work as involved in this schedule shall be measured & paid under Sch 'A' Part IV (Site clearance & earth work) 12 Each
140 17 Total amount of SCHEDULE 'A' PART-XIA (EXTERNAL ELECTRIC SUPPLY) (For details see Schedule 'A' Part-XIA in PDF folder) 1 Complete Sch 'A' Part-XIA
141 18 SCHEDULE 'A' PART-XI B (EXTERNAL ELECTRIC SUPPLY)
142 18.01 M&L for 2x36W CFL Roadway lightining luminaires light fittings with a refelector, perplex cover, ballast, connector,capacitor etc complete and pre wired with copper flexible wire and fixing complete fixed on steel tubular pole / RCC rectangular pole complete taking down old existing light U/S fittings all as directed. Make : Bajaj Model : BJSLF236 CFL /Philips/Havells .\n 85 Each
143 18.02 M&L for replacement light grade GI pipe bracket made of 40mm dia light grade pipe, 1.2 mtr long bend to shape as directed , fixed on pole with two nos MS clamp made of 40 x 5mm flat (duly painted) with nuts bolts etc for steel tubular pole / RCC rectangular pole etc complete, all as specified and directed 85 Each
144 18.03 Supply & laying,Testing and commisioning insulated , galvanised steel strip or wire armoured, heavy duty electric power cable with stranded aluminium conducter 1100 volt grade cross sectional areas 10 sqmm,2core \n 291 RM
145 18.04 -do- all as per item No.18.03 above but 16 Sqmm 4 core. 755.1 RM
146 18.05 -do- all as per item No.18.03 above but 25 Sqmm 3.5 core. 442.5 RM
147 18.06 -do- all as per item No.18.03 above but 50 Sqmm 3.5 core. 156 RM
148 18.07 -do- all as per item No 18.03 above but 70 Sqmm 3.5 core. 104 RM
149 18.08 -do- all as per item No.18.03 above but 240 Sqmm 3.5 core. 40 RM
150 18.09 Supply, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable in trenches on poles/through duct, (Heavy duty) with std aluminium conductor, 11/6.35KV (UE) grade of size120 Sqmm 3 Core etc complete, all as specified and directed 250 RM
151 18.1 S&F in replacement triple pole, mechanically operated gang operated air break switch mounted on insulator (Three post insulator for each phase) and steel frame complete with operating mechanism worked from ground level with heavy tinned non-ferrous metal spring loaded copper contact silver/tin plated at contact points with locking arrangement for correct rating upto 400 Amps suitable for 11000 volts grade complete all as specified and directed 6 Each
152 18.11 Supply & fixing sheet metal encloser made out of 3.15 mm thick CRCA sheet, dust, factory made vermin proof powder coated of size 300x200x150mm, 415 Volt, TPN, single door, with 20x3mm aluminium bus bar of suitable size complete with MCB SP 10 Amps with 40x5mm MS clamp nut bolt washer etc. complete all as specified and directed 65 Each
153 18.12 Supply and install AC 3 phase 200 KVA capacity transformer copper wound step down outdoor type 11000/433 volts at no load oil immersed naturally cooled with external cooling tubes/fins core type, Delta connection on primary ( HV side) in accordance with vector group DY-11 with neutral brought on secondary ( LV side and having tappings at + 2.5, + 5%, + 7.5% be changed by means of hand operated "OFF LOAD" Tap changer gear complete including testing and comprising with the following :- 1 Each
154 18.13 (a) HT bushing suitable for 11 KV complete with all accessories \n housing in sheet steel enclosure - 03 Nos \n(b) LT bushing suitable for 1100 BV complete with all accessories \n housing in sheet steel enclosure- 04 Nos \n(c) Oil conservator with filter type drain valve and oil level gauge. \n(d) Dehydrating breather with first fill dehydrating agent. \n(e) Explosive vent.\n(f) Thermometer pocket on tank cover. \n(g) One number 100 mm dia type thermometer, vapour pressure type, having range 0-120 degree centrigrade with maximum reading pointer,\n Max temperature indicator and resting device. \n(h) Rating plate with terminal marking . \n(j) Two Nos earthing terminals on tank and cover to facilitable fixing of 32mm x 6m strip. \n(k) Oil level gauge. \n(l) Oil drain filter valve. \n(m) lifting lugs. \n( n) Oil filter hole with cap/plug with connection complete. \n(o) Air release valve plug \n(p) Four plain solid cast settel detachable rollers. \n(q) First fill of fresh trams former oil confirming to relevant I.S and tested upto 40 Kv dielelctric strength.
155 18.14 All as per Item No. 18.12 & 18.13 above but of capacity 315 KVA 1 Each
156 18.15 S&F MD XL double metalized paper capactior for three phase 440 Volt 50 cycle system for permissible for nonlinear load of capacity 70 KVAR (25X3) etc complete, all as specified and directed 1 Each
157 18.16 Supply & fixing APFC Panel with MD XL double meatilize capacitor and MCCB as incomer auto/manual operation for three phase 440 Volt 50 Cycle system for permissible for nonlinear load of capacity 100 KVAR (25X4).etc complete, all as specified and directed 1 Each
158 18.17 Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at depth not less than 1.5 meter below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt fillling in alternate layers and electrode connections by using GI strip 32 x 6 mm iron and protected by light grade 40 mm dia GI pipe connected to main switch board or main control board and GI pipe light grade, 20 mm bore for watering and including funnel wire mesh RCC pit cover and PCC chamber pit with PCC 1:2:4: type C2 (including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 meter) all as specified and shown on plate No. 3 SSR Part I-complete all as specified and directed. 16 Each
159 18.18 M&L earthing complete with galvanised mild steel earth plate (electrode) 600 x 600 x 6.00 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.5m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 4 mm dia GI wire as earth wire lead moulded and riveted to earth plate at one end and connected to main switch/control switch of the building at another end, GI earth wire incased in and including 15 mm dia GI ‘light grade’ pipe from upper end of earth plate upto main switch/control of the building including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of earth plate, CI funnel with wiremesh fixed on water pipe and PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in pit chamber & RCC pit cover 50mm thick precast RCC 1:2:4 type B-1 duly reinforced with MS bar 6mm dia@ 100cc both ways with 10mm dia MS bar in lifting handle excavation earth work etc all as directed in electrical plate No 3 of SSR pt 1 complete all as specified and directed 18 Each
160 19 Total amount of SCHEDULE 'A' PART-XII A (CABLE NETWORKING) (For details see Schedule 'A' Part-XII A PDF folder) 1 Complete Sch 'A' Part-XIIA
161 20 SCHEDULE 'A' PART-XII B (CABLE NETWORKING)
162 20.01 M & L for Telephone socket RJ-11 with metal flush box sand cover plat complete all as specified and directed. 25 Each
163 20.02 M & L Providing, drawing, connecting and testing of telephone wire 20 pair 0.5mm dia tinned annealed high conductivity copper conductor with high density Polyethylene insulation, paired, polyster taped and FR PVC sheathed complete all as specified and directed. 500 RM
164 20.03 Supply&Fixing co-axial cable RG-11 etc complete all as specified and directed. 500 RM
165 21 Total amount of SCHEDULE 'A' PART-XIII A (LIGHTING PROTECTION) (For details see Schedule 'A' Part-XIII A PDF folder) 1 Complete Sch 'A' Part-XIII A
166 22 SCHEDULE 'A' PART-XIII B (LIGHTING PROTECTION)
167 22.01 M&L for Earthing complete with GI earth plates electrode 600x600x6mm thick burried directly in ground earth pit not less than 4.50 mtr deep below ground level with top edge of earth plate not less than 1.5m below GL the plate surrounded with adequate quantity of charcoal dust mixed with salts to a packet thickness of 15 cm all around the plate,using GI earth strip 32x6mm connected to earth plate by means of nut ,bolts and washers GI pipe light grade 40mm bore for protection of strips from edge of earth plate to test point including water pipe of size light grade 40 mm from earth chamber to edge of earth plate,CI funnel with wiremesh fixed on water pipe and PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in pit chamber and RCC pitcover 50mm thick pre-cost RCC 1:2:4 type B-1 dully rainforced with MS bars 6mm dia @150 C/C both ways with 10mm dia MS bar in lifting handle including excavation earth work etc all as directed in electrical plate No 3of SSR pt I complete all as specified and directed. 16 Each Set
168 23 SCHEDULE 'A' PART-XV (WATER COOLER, DESERT COOLER, REFRIGRATOR AND GYESER
169 23.01 Supply and Installation Deep freezer with metal top,non CFC refrigerant type,electric driven(single phase) of capacity 300/320 Ltrs,frost free complete all as directed. 2 Each
170 23.02 S&F automatic operation single phase stablizer,naturaly air cooled and designed for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts with accuracy of +/- 2.5% and capacity 2 KVA complete all as directed. 3 Each
171 23.03 Supplying& Installation commissioning and testing mortuary cabinet single phase 230volt ,0.5mm thick exterior and interior finish prepainted GIsheet 0.50mm thick front finish in stain less including vapour proof incandescent lamp,one piece stainless steel tray ,inbuilt power pannel etc suitable for unitary type refrigeration system and and temprature range of 4-6 degree centrigate of capacity two body complete all as specified & directed. 1 Each
172 23.04 Supply & Installation only, Desert cooler,electric driven(S.P),230 volts,AC,air flow capacity 4000Cum/Hr,blade size 406/16 mm ,PVC body,3 speed,1400 RPM,160 watt,45 ltrs water tank cap,motorisedloures movement,top water inlet complete with pump & motor all as directed. 44 Each
173 23.05 Supply & Fixing Water heater storage type,25Litre capacity electric supplied and installed etc complete all as specified and directed 11 Each
174 24 Total amount of SCHEDULE 'A' PART-XVI A (SOLAR WATER HEATER ) (For details see Schedule 'A' Part-XVIA PDF folder) 1 Complete Sch 'A' Part-XVI A
175 25 SCHEDULE 'A' PART-XVI B (SOLAR WATER HEATER)
176 25.01 Supply & Installation Only, of solar water heating system ETC (Evacuvaed Tube Collector) type complete with electric back up based on direct transfering of heat of capacity 100 LPD etc complete in all respect duly clamped.etc complete all as specified and directed. 2 Each Job
177 25.02 Supply & Installation Only, of solar water heating system ETC (Evacuvaed Tube Collector) type complete with electric back up based on direct transfering of heat of capacity 500 LPD etc complete in all respectt duly clamped.etc complete all as specified and directed. 1 Each Job
178 26 SCHEDULE 'A' PART-XVII (EMERGENCY LIGHT FITTING &HAND DRYER& SHADOWLESS LIGHT FITTING)
179 26.01 Supply and fixing Automatic air hand dryer with sensor suitable for 230volts 50Hz etc complete all as specified and directed 5 Each
180 26.02 Supply and fixing Soap Dispenser of 500ML Capacity etc complete all as specified and directed 5 Each
181 26.03 Supply and fixing Miniature emergency light fitting including suitable size of cable with accessories for 2 x 8 watts 200 LM signaling ,single phase 230volts 50Hz complete all as specified and directed 7 Each
182 26.04 M&L for Shadow less light fittings complete with emergency power unit & battery back up for min 30 minutes (3 KVA),having dome of 710 mm dia fully counter balanced, moveable on ceiling trolly having a min longitude travel of 1350 mm,color temprature 42000K,07 Nos halogen bulbs,12 v 50 Watt each and axial rotation of 360 degree lux output 130000 lux.The unit to be suitable for operation on 230 V,SP,50 cycles main supply.\nModel : Philips Phililux Major OT light and equivelent as directed. 1 Each
183 26.05 -- do -- All as per item no 26.04 above but for mobile shadow less light fitting (Lux level 75000 lux,Halogen bulb- 05 Nos, 12 Volts .\nModel : Philips S50 Mobile OT light.and equivelent as directed. 2 Each
184 27 SCHEDULE 'A' PART-XVIII (SOLAR STREET LIGHT)
185 27.01 Supply and fixing Solar energy operated street light 14 watts LED including fitting suitable size of cable with accessories ,pole , battery , battery box with locking arrangement , solar plate complete including PCC foundation for pole using PCC 1:3:6 type C-1 using 20mm stone aggregate complete all as specified and directed 10 Each
186 28 SCHEDULE 'A' PART-XIX(AIR CONDITIONING )
187 28.01 Supply, Installation, testing & commissioning only Hi wall split units indoor/outdoor complete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with of capacity 2.0 TR complete all as directed. 4 Each
188 28.02 S&F automatic operation single phase stablizer,naturally air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 5 KVA complete all as directed. 4 Each
189 29 Total amount of SCHEDULE 'A' PART-XX (CHAIN LINK FENCING ) (For details see Schedule 'A' Part-XX PDF folder) 1 Complete Sch 'A' Part-XX
190 30 SCHEDULE 'A' PART-XXI (FIRE SAFETY) \n
191 30.01 Supply & Installation of Multipurpose fire extinguishers stone Pressure water carbon Dioxide type9.0 Kg capacity ,IS-940/5234 wall mounted type, wall brackets complete in all respect, including fixing on walls complete all as specified and directed. 20 Each
192 30.02 Supply & Installation of portable fire extinguishers ABC Powder type 5 Kg capacity,as per IS-2171/13849,14609, wall mounted type, wall brackets complete in all respect, including fixing on walls complete all as specified and directed. 20 Each
193 30.03 Supply & Installation of Multipurpose fire extinguishers stone Pressure water carbon Dioxide type 5.0 Kg capacity ,IS-2878 wall mounted type, wall brackets complete in all respect, including fixing on walls complete all as specified and directed. 20 Each
194 30.04 M&L,for Provision of 50000 litre SWT complete all specified and shown on Drawing 1 Each
195 31 SCHEDULE 'A' PART-XX1I (MEDICAL GAS SYSTEM)\n
196 31.01 (A) OXYGEN SYSTEM\nSupply, fixing, testing and commissioning of Indian 10 + 10 Size of oxygen manifold complete with 20 nos. pig tail pipes & 20 nos. of non return valves with middle frame .complete all as specified and directed 0.5 Each Set
197 31.02 Supply, fixing, testing and commissioning of Imported Anodised aluminum body and control knob Oxygen flow meter with Humidifier Bottle. 0-15 L/min standard flow rate complies with HTM 02-01,BS 5682:1998 and C-11 all as specified 20 Each
198 31.03 Supply, fixing, testing and commissioning of Imported Oxygen H.P. anstistatic tube,white color all as specified 15 RM
199 31.04 (B) INDIGENOUS MEDICAL COPPER PIPES\nSupply, fixing, testing and commissioning of the copper pipe used should be half drawn tempered seamless phosphorous non arsenic degreased confirming to latest BSEN 13348 : 2008 KITE MARK certification is must Chemical Composition:as per CUDHP to ISO 1190.1CW024A to EN 1412 Cleanliness Maximum total carbon content 0.20mg/dm2. Packaging :Each tube individually end capped tube bundles polythene wrapped and sealed Size 12-76mm copper tubes are stamped with (a) Kite Mark (b)EN 13348. (c)Tamper All as specified and directed
200 31.05 12mm OD 120 RM
201 31.06 15mm OD 275 RM
202 31.07 (C) IMPORTED LOCKABLE LINE VALVES\n\nSupply, fixing, testing and commissioning of Imported 15mm lockable line valves 1 Each
203 31.08 (D) CYLINDERS\n\nSupply, fixing, testing and commissioning of Oxygen D Type bulk cylinder complete all specified and directed as under :-\n\n (a) 232mm ODX1365MM LENGTHX46.7 LITRE water capacity in each cylinder\n\n(b) 6.7 Cubic meter=6700 litres Oxygen capacity in each cylinder\n\n(c) Complies with IS 7285( Part 2 ):2004 \n\n(d) Minimum wall thickness =5.20mm\n\n(e) CCOE Aproved \n\n(f) Test Pressure=250kgf/cm2\n\n(g) Working Pressure at 15DegC= 150 kgf/cm2\n\n(h) Nominal Tare Weight=51.00kg with Neck ring\n\n 10 Each
204 32 SCHEDULE 'A' PART-XXIII (OIL FIRED INCENIRATOR)
205 32.01 Supply, installation, testing and commissioning of oil fired incinerator having 20 Kg/Hr burning capacity horizontal/vertical type comprising of primary chamber, secondary chamber, designed on "controlled air" incineration principle and provided with minimum of 115 mm thick refractory and insulation bricks conforming to IS 8-1994 and IS 2042-2006 to sustain minimum temperature of 1000 C in the primary chamber and 1200 C in secondary chamber, one fully automatic pressure jet type burner for each chamber, chamber made of mild steel plate of adequate thicknes ( minium 5 mm thick), 30 meter high chimnery, exhaust system, high pressure ventury Scrubber, PLC based control panel, droplete separator etc. including all other accessories and piping, equipment and civil works required for insatllation of incinerator chimney complete all as specified including following :- \n 1 Each Job
206 32.02 (a) Fuel tank suitably fabricated out of mild steel, provided with connection for supply, return, drain & vis checking of quantity of fuel in tank. \n\n(b) An emergency stack to vent out the gases in case of power failure. \n\n(c) Circulation pump, recirculation tank, inter connection piping, ID fan, FD fan, instruments, valves, dampers & fitting etc. \n\n(d) Electrical control panel with all electrical power, earth & control cabling.
207 32.03 Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground, earth pit not less than 2.25meters deep below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate using 32x6 mm GI strip as earth conductor moulded and rivetted to earth plate at one end and connected to main switch/control switches of buildings at another end, GI earth strip including 40 mm dia GI light grade pipe from upper end of earth plate upto main switch/control board of building includng 20 mm dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, CI funnel with wire mesh fixed on water pipe and provision of PCC chamber with PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:3:6 type C-1 duly reinforced with MS round bars 6 mm dia at the rate of 150mm C/C both ways with 10mm dia MS round bar as in lifting handles including excavation, earth work laying of GIpipe concealed in floor/wall all as specified and directed. 6 Each Set
208 33 Total amount of SCHEDULE 'A' PART-XXIV (DEMOLITION /DISMANTLING) (For details see Schedule 'A' Part-XXIV PDF folder) 1 Complete Sch 'A' Part-XXIV
209 34 Note : Tenderers may be noted that amount of credit Rs. 1,61,33,559.25 will be deducted from the total amount arrived, at the time of acceptance of contract. (For details please refer Sch 'A' part XXV 'A', part XXV 'B' and part XXV 'C').