}

Call Basis Maintenance Of Wac, Sac Units At Various Te Bldgs/ Bts Sites In Solapur & Osmanabad Ssas, Mumbai-Maharashtra

Bharat Sanchar Nigam Limited-BSNL has published Call Basis Maintenance Of Wac, Sac Units At Various Te Bldgs/ Bts Sites In Solapur & Osmanabad Ssas. Submission Date for this Tender is 21-04-2020. Tanks and Cylinders Tenders in Mumbai Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

24042116
Corrigendum : Call Basis Maintenance Of Wac, Sac Units At Various Te Bldgs/ Bts Sites In Solapur & Osmanabad Ssas
Open Tender
Indian
Maharashtra
Mumbai
21-04-2020

Tender Details

Call Basis Maintenance Of Wac, Sac Units At Various Te Bldgs / Bts Sites In Solapur & Osmanabad Ssas , Attending And Rectification Of Existing Window / Split Ac Faults Including Providing Minor Spares If Reqd Such As Connecting Copper Wires , Removing & Cleaning Of Filters , Cleaning Of Units By Blowers , Control Fuse , Ferrules , Lugs I / C Minor Works Etcalongwith Testing & Commissioning In Urban Site Complete As Required . ( Item Will Be Measured On Submission Of Visit Report Duly Signed By Bsnl Authority And Allowed At Once Per Site Per Fault ) ( Note:- For Subsequent Visit To Attend The Window / Split Ac To Provide The Items Hereunder Will Not Be Paid Separately . It Is Assumed That All Items As Below Shall Be Carried Out By Firm In First Visit Only ) , Attending And Rectification Of Existing Window / Split Ac Faults Including Providing Minor Spares If Reqd Such As Connecting Copper Wires , Removing & Cleaning Of Filters , Cleaning Of Units By Blowers , Control Fuse , Ferrules , Lugs I / C Minor Works Etcalongwith Testing & Commissioning In Rural Site Complete As Required . ( Item Will Be Measured On Submission Of Visit Report Duly Signed By Bsnl Authority And Allowed At Once Per Site Per Fault ) ( Note:- For Subsequent Visit To Attend The Window / Split Ac To Provide The Items Hereunder Will Not Be Paid Separately . It Is Assumed That All Items As Below Shall Be Carried Out By Firm In First Visit Only ) , Carrying Out Wet Servicing Of 1 . 5Tr / 2Tr Window / Split Ac Unit I / C Removing , Cleaning All Components And Filters , Dedusting By High Pressure Air Blower , Washing Condenser , Evaporator I / C Chemical Cleaning ( If Required ) , Refixing , Tightening Electrical Connections , Testing Of Ac Unit , Recording All Parameters In Service Report Etc As Reqd . , Carrying Out Leak Testing Of 1 . 5Tr / 2 Tr Split / Wac Ac Units With Nitrogen Gas Including Dismantling Of Machine , Flushing The System , Brazing / Flaring The Leak Points , Vacumising , Purging And Making The System Leak Proof I / C Transportation Of Nitrogen Cylinder , Brazing Kit & Vacuum Pump , Supplying & Charging Of R22 Refrigerant Gas At Site , Reinstallation , Testing & Commissioning Etc As Required . , 1 . 5 Tr , 2 . 0 Tr , Replacement Of Following Capacity Of Existing Old Defective Compressor With New Sealed Compressor I / C Dismantling Of Faulty Compressor , Cutting Refrigerant Piping , Brazing & Making Necessary Addition / Alteration I / C Proper Mounting On Base Plate , Connection Of Suction And Discharge Lines , Leak Test & Charging Refrigerant I / C Testing Etc As Reqd . ( M / S Emerson / Tecumseh / Ss Make ) ( Note- The Firm Shall Submit Test Certificate Or Documentary Proof Towards Purchase Of New / Oem Factory Repaired Compressor . ) The Defective Compressor Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting . The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) , 1 . 5 Tr , 2 . 0 Tr , Replacement Of Following Material For Repairing & Attending Break Down Complaints Of 1 . 5 / 2 Tr Wac / Sac Units I / C Dismantling , Connection , Fixing & Testing Etc As Required ( Note- The Defective Material Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting . The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory . , Starting Capacitor ( Metal Body ) Of Rating 80 / 100 Mfd ( M / S Epcos / Asian / Ss Make ) , Running Capacitor ( Metal Body ) Of Rating 36 Mfd ( M / S Epcos / Asian / Ss Make ) , Repairing Of Control Card Of Indoor Split Ac Unit , Replacement Of Control Card Pcb Suitable For 1 . 5Tr Split Ac Units , Condenser Fan Blade ( Pvc / Frp ) , Box Type Relay For Window Ac Units . ( M / S Arvind / Ranutrol / Ss Make ) , Selector Switch For Window Ac Units , Blower Fan Motor For Idu Of Split Ac Unit ( M / S Aue / Marathonge / Natinoal / Diamond / Ss Make ) , Thermostat ( M / S Danfoss / Indfoss / Arvind / Ss Make , Washable Nylon Air Filter , Replacement Of Condenser Motor Of 1 . 5 / 2 Tr Split / Window Ac Unit From Workshop Complete With Reinstallation , Testing Etc As Required , Replacement Of Rusted Base Plate Of Window Ac 1 . 5 Tr Unit With Ms Sheet Plate I / C Fabrication & Mounting Of All Accessories Etc As Required . , Dismantling & Shifting Of Existing Indoor & Outdoor Unit From One Site & Itc At Another Site & Dismantling Existing / Faulty Unit & Keeping It To The Location As Directed By Engineer-In-Charge Etc . Complete Testing , Connections Complete As Reqd . ( Note: Transportation Charges Shall Be Paid Extra )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Mar-2020 Corrigendum Date 21-04-2020

Key Value

Document Fees
INR 590 /-
EMD
INR 9692.0 /-
Tender Value
INR 4.84 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail