Special Repairs Mo To Modification Of Existing Panel And Over Head Line To Replace Ug Cable From Single Officers Accn To Officers Mess Area And Provision Of Security Lights Near Main Gate And Near Gate At 191 Fd Regt Madukkarai Under Ge Wellington, Coimbatore-Tamil Nadu

Military Engineer Services-MES has published Special Repairs Mo To Modification Of Existing Panel And Over Head Line To Replace Ug Cable From Single Officers Accn To Officers Mess Area And Provision Of Security Lights Near Main Gate And Near Gate At 191 Fd Regt Madukkarai Under Ge Wellington. Submission Date for this Tender is 09-06-2020. Electrical Panel Tenders in Coimbatore Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

24012612
Corrigendum : Special Repairs Mo To Modification Of Existing Panel And Over Head Line To Replace Ug Cable From Single Officers Accn To Officers Mess Area And Provision Of Security Lights Near Main Gate And Near Gate At 191 Fd Regt Madukkarai Under Ge Wellington
Open Tender
Indian
Tamil Nadu
Coimbatore
09-06-2020

Tender Details

Special Repairs Mo To Modification Of Existing Panel And Over Head Line To Replace Ug Cable From Single Officers Accn To Officers Mess Area And Provision Of Security Lights Near Main Gate And Near Gate At 191 Fd Regt Madukkarai Under Ge Wellington

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Apr-2020 Corrigendum to Critical Dates Date 24-04-2020
2 27-Apr-2020 Corrigendum to Critical Dates1 Date 06-05-2020
3 08-May-2020 Corrigendum to Critical Dates2 Date 18-05-2020
4 19-May-2020 Corrigendum to Critical Dates No 3 Date 26-05-2020
5 27-May-2020 Corrigendum to Critical Dates No 5 Date 02-06-2020
6 03-Jun-2020 Corrigendum to Critical Dates No 7 Date 09-06-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 12000.0 /-
Tender Value
INR 6 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIRS (M&O) TO MODIFICATION OF EXISTING PANEL AND OVER HEAD LINE TO REPLACE UG CABLE FROM SINGLE OFFICERS ACCN TO OFFICERS MESS AREA AND PROVN OF SECURITY LIGHTS NEAR MAIN GATE AND NEAR GATE AT 191 FD REGT MADUKKARAI UNDER GE WELLINGTON
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down of ACSR conductor of any size from RCC / steel tubular poles by dismantling the binding wire, insulator, etc all as specified and directed. 1.11 QTL
2 2 Taking down existing cross arms of any type and any size including bracing, support clamps and back plate by unscrewing bolts and nuts etc all as specified and directed. 0.3 QTL
3 3 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in hard / dense soil for laying of UG cables, etc all as specified and directed. 110.6 CUM
4 4 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft / loose soil for laying of UG cables, etc all as specified and directed. 30.5 CUM
5 5 Removing excavated materials not exceeding 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed. 26 CUM
6 6 Returning, filling in, spreading, levelling, watering and ramming in layers not exceeding 25cm thick in any type of soil all as specified and directed. 109.6 CUM
7 7 Supply, Laying and testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 70 Sqmm, 3.5 core all as specified and as directed. 40 RM
8 8 All as item No 7 hereinbefore but Size of cable 50 Sq.mm, 3.5 core complete all as specified and as directed. 280 RM
9 9 All as item No 7 hereinbefore but Size of cable 16 Sq.mm, 4 core complete all as specified and as directed. 45 RM
10 10 All as item No 7 hereinbefore but Size of cable 16 Sq.mm, 2 core complete all as specified and as directed. 30 RM
11 11 All as item No 7 hereinbefore but Size of cable 6 Sq.mm, 2 core complete all as specified and as directed. 260 RM
12 12 GI tubing light grade 40mm dia bore for protection of cable fixed in wall or laid in trenches including taking up or down old unserviceable tubing all as specified and directed. 20 RM
13 13 Cutting of existing bituminous surface road including returning filling in and making good with material and labour for PCC (1:3:6) type C1 using 20mm graded stone aggregrate to match with the existing surfaces all as specified and directed. 7.4 CUM
14 14 Sand cushioning to PVC cable with using crushed stone sand produced from hard granite having cubical shape particle known as M sand or river sand gently punned below / around cable all as specified and directed. \nNote: Punned thickness only will be measured and paid.\n 42.6 CUM
15 15 Burnt bricks sub class B of old size, laid dry in trenches for under ground cable protection all as specified and directed. 4134 EACH
16 16 Straight through cable jointing kit for 1100volts grade cable complete with jointing material heat shrinkable and accessories suitable for 2 core / 4 core XLPE / PVC insulated armoured aluminium conductor cable of size 10Sqmm to 70Sqmm all as specified and directed. 4 EACH
17 17 Earthing complete with GI earth plate electrode 60x60cmx6.3mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth wire 4mm dia protected by GI pipe light grade 15mm dia and connected to panel board / DB by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 3 of SSR part I including necessary earth work and excavations in any type of soil, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 cover slab, reinforcement with 6mm dia MS bars at 100mm dia both ways, MS hook 6mm dia MS bars etc complete all as specified and directed. 1 EACH
18 18 Supply, install, testing and commissioning of factory made LT cubical panel outdoor type made up of 3.15 mm thick CRCA sheet weather, dust & vermin proof, approximate size 2.25x0.50x1.50M, double door, front & back opening detachable type complete made up of suitable angle iron frame with locking arrangement duly mounted on angle iron frame of suitable size grouted on PCC plinth, painted with two coats of powder coating over a coat of red oxide primer conforming to IS 8623, IP 54 protection including necessary glands etc at the bottom sheet cover and consisting of the following items:- \n(i) Busbar chamber 100Amps capacity mounted on porcelain insulator copper strip insulated complete alongwith internal wiring for measuring instruments.\n(a) MCCB 100 amps, 4 pole, 25KA, 415 Volts - 01 No for main Incomming.\n(b) MCCB 100 amps, 4 poles, 25KA, 415 volts -01 No for main outgoing.\n(c) MCCB 63 amps, 4 poles, 25KA, 415 volts -03 Nos for outgoing.\n(d) MCCB 63 amps, 4 poles, 25KA, 415 volts -01 No for spare.\n(e) MCB 32 amps, 4 poles, 10KA, 415 volts -01 No for outgoing.\n(f) LED indicator lamps (R,Y,B) - 01 Set\n(h) Digital Ampire meter with current coil of 100 x 100 mm - 01 No.\n(j) Digital volt meter with selector switch of 100 x 100mm square - 1 No\n(k) Timer of Digital time switch FM / 1 quarts of L&T\n(l) Contactor of type MNX 40 3 pole contactor of Cat Part No CS94190 of make L&T 1 JOB
19 19 GI tubing light grade 25mm dia bore for protection of cable fixed in wall or laid in trenches including taking up or down old unserviceable tubing all as specified and directed. 25 RM
20 20 Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, silver colour painted as specified type 410 SP-22 (8.5 meters long) all as specified and directed. 7 EACH
21 21 PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundations filling and mass concrete for steel tubular pole (0.10 x 0.60 x 0.60) all as specified and directed. 0.2 CUM
22 22 Cement concrete (1.50 x 0.60 x 0.60) in mass concrete type C1, 1:3:6 using 20mm grade stone aggregate for steel tubular pole all as specified and directed. 3 CUM
23 23 Cement concrete (45 x 0.45 x 0.45) in mass concrete type B1, 1:2:4 using 20mm grade stone aggregate for steel tubular pole all as specified and directed. 0.54 CUM
24 24 Energy conservation 120 watts ENDURA city liner NEO IP-66 impact resistance of 1K07 including connection with suitable size of cable with PVC conduit and 40mm GI bracket 3 meter length 90 bend with clamp and nuts, bolt all as specified and directed.\nMake: Havells Cat Part No. ENDURACITY LINER NEOSEL120WLED757SASYBOTG) or equivalent in Philips / CG LED light as approved by GE) 7 EACH
25 25 Junction box sheet moulding compound type with hinged type door locking arrangement, white colour of size 200x100x105 (out door type) with MCB SP 6Amps fixing in the box complete all as specifed and directed. 7 EACH
Disclaimer :