Military Engineer Services-MES has published Tender For Additional Alternation Of Central Air Conditioning Plant Of Icu/Ot Complex At Af Stn Jorhat. Submission Date for this Tender is 20-06-2020. Air Conditioner Tenders in GE (AF) JORHAT Assam. Bidders can get complete Tender details and download the document.




Tender Notice

24011807
Corrigendum : Tender For Additional Alternation Of Central Air Conditioning Plant Of Icu/Ot Complex At Af Stn Jorhat
Open Tender
Indian
Assam
GE (AF) JORHAT
20-06-2020

Tender Details

Tender For Additional Alternation Of Central Air Conditioning Plant Of Icu / Ot Complex At Af Stn Jorhat

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Apr-2020 Corrigendum _1 Date 01-05-2020
2 22-Apr-2020 Corrigendum2 Date 12-05-2020
3 04-May-2020 Corrigendum_3 Date 20-05-2020
4 13-May-2020 Corrigendum_4 Date 27-05-2020
5 19-May-2020 Corrigendum_5 Date 02-06-2020
6 23-May-2020 Corriendum_6 Date 06-06-2020
7 27-May-2020 Corrigendum_7 BOQ 06-06-2020
8 06-Jun-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-06-2020
9 12-Jun-2020 Corriendum8 Date 20-06-2020
10 18-Jun-2020 Corriendum9 Technical Bid 20-06-2020

Key Value

Document Fees
INR 2000 /-
EMD
INR 495000.0 /-
Tender Value
INR 4.20 Crore /-

BOQ Items

Name of Work: ADDN/ALTN OF CENTRAL AIR CONDITIONING PLANT OF ICU/OT COMPLEX AT 5AFH JORHAT
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Addn/Altn to buildings\nDismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as directed. 1250 Sqm
2 2 S&F bonded fibre mineral wool blanket slabs made from mineral wood blanket slabs made from rock slag density 48 Kg/Cum and fixed as per markers instruction of 40 mm thick fixed on ceiling complete all as directed. 1250 Sqm
3 3 S&F 20 mm size wire netting of galvanised steel wire 1.4 mm dia fixed with tinned tracks of wire staples fixed to ceiling complete all as directed. 1250 Sqm
4 4 Supply and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) 1250 Sqm
5 5 Supply and fixing for false ceiling anodised aluminium snap grid (605X605mm size) to support the boards / tiles with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long\nall as specified and directed. 1250 Sqm
6 6 Material & labour for preparing new plastered or unplastered surfaces of ceilings and applying two coats of distemper oil bound washabel distemper, as in ceilings complete all as specified and as directed. 1250 Sqm
7 7 Material & labour for preparing old distempered surfaces of walls by washing, rubbing down stopping of distempered and painted surfaces and applying one coat of distemper oil emulsion (oil bound washable distemper), complete all as specified and as directed. 4000 Sqm
8 8 Material & Labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as directed. 13 Sqm
9 9 Material & Labour for precast RCC (1:1.5:3) type A1( using 20mm graded agg) as in cover slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves s etc set in cm 1:4 complete all as directed. 3 Cum
10 10 Supply and fixing for TMT bars, 10mm dia and over, cut to length, bent to shape\nrequired, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.\n 190 Kg
11 11 Material and labour for 250mmX375mmX7mm thick decorative type wall tiles (coloured) joint free as in vertical surfaces of and jointed with neat cement slurry and pointed in white/coloured cement to match the surface laid over and including 10mm thick rendering in CM(1:3) complete all as specified and as directed . 42 Sqm
12 12 Supply and Fixing Granite (of any type) tiles 20mm thick machine cut, bedded and\njointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing\ncomplete over and including 20mm screed bed in CM(1:6) completed all as directed 32 Sqm
13 13 Material and labour for 2mm thick linoleum, plain colouredlaid dry in floors including stretching, cutting and fitting is sealed down with an approved adhesivew complete all as specified and directed. 100 Sqm
14 14 S&F anodised aluminium frame for doors, windows, ventilators, with one or more rebates including joining cleat for fixing etc complete all as specified and directed. 190 Kg
15 15 Supply and Fixing Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. 12 Sqm
16 16 M&L12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work incl necessary fitting complete all as specified and directed. 10 Sqm
17 17 S&F 75mm long hasp and staple, safety type, aluminium anodised including bolt to hinge plate and fixed with screws complete all as directed. 12 Each
18 18 InternalElectrification Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified. 115 Per Point
19 19 M & L for point wiring with 1.5 sqmm FR grade PVC insulated cable 1100 volts grade as per IS-694 stranded copper conductor cable drawn through and including PVC casing and capping (not less than 20 mm wide) complete with all fittings and acessories including MS sunk box of thickness 1.6mm and hylem sheet cover of 3 mm thick for mounting of switches, sockets, regulators, etc and 1.5 sq mm stranded copper conductor cable FR grade PVC insulated for earth continuity all as specified and directed for one light / Fan Point controlled by one Switch. 115 Per Point
20 20 Supply and fix switch piano flush type, 6 Amps 240 volts single pole one way. \nMake:- Anchor cat No. 14111, Havells cat No. Reo-AHESXXW061. 115 Each
21 21 Supply and fix ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body. Make:- Anchor Cat No. 39040, Havells Cat No.AHLHXCW000. 115 Each
22 22 Supply and fix stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as specified and directed by Engr-in-Charge. \nMake Havells Cat No. AHERFXW002 OR any equivalent model in Anchor / SSK 30 Each
23 23 Supply and fix ceiling/recess mounting LED 4x1 luminaire of capacity 36W/34W with white powder coated CRCA housing with LEDs and full window acrylic diffuser etc. complete with all accessories, internally prewired, suitable for single phase 230 Volts, 50 Hz AC supply including connecting up with flexible copper conductor cable of size 0.5 Sqmm (nominal area) of Make : Bajaj, Cat No. BZRSLL 36W WH / Havells, Cat No.- LHEWEBP6PL1W034 or equivalent model in Crompton Greaves / Philips. 85 Each
24 24 Taking down carefully unserviceable sub main wiring single/three phase with neutral & earthing of any description with all accessories complete and making good disturbed surface of wall/floor/ceiling etc complete all as specified. 80 RM
25 25 Supply and draw submain wiring with two single core 6 sqmm FR PVC insulated copper cable 1100 vots grade multistrand, unseathed conductor drawn into PVC casing and caping and all necessary fittings including 4 sqmm multi strand FR PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete (for shadowless lamp connection from CVT), complete all as specified and directed. 80 RM
26 26 Taking down Ceiling Fan of any Sweep and Make by disconnecting Electric Connection, dismantling Blades, Down Rod and removing Ceiling Fan and deposite to MES STORE YARD OF AGE E/M (AF) JORHAT, complete all as specified and as directed. 30 Each Job
27 27 M&L for overhauling and painting of ceiling fan / Exhaust fan of any make/ model/ sweep of 1200/1400 mm with one coats of synthetic enamel paint of approved quality and colour as that of existing by spray painting after prepairing the surface throughly including filling cavities by filler and marking of MES No. all as specified and directed 30 Each
28 28 Assembling and hanging only ceiling fan of any sweep, complete including connections with PVC insulated 3 core copper flexible wire of size 1.0 sqmm of length not exc 1.5 Mtrs. 30 Each
29 29 External Water Supply\nSupply & Laying & testing in trenches GI pipe medium grade 80 mm bore ISI marked with all fittings complete all as specified and directed . 440 RM
30 30 Material and labour for Sluice valve PN 1.6 conforming to IS 9338, supplied and installed of size 80mm dia complete all as specified and directed. 2 Each
31 31 Material & Labour for brick masonry valve pit of internal size 90cm x 90cm x 90cm suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cement mortar 1:6 renderin 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including necessary earth work, including MS sheet cover of thickness 3.15mm on 50X50X6.0mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement including demolished old valve pit complete all as specified and as directed . 2 Each
32 32 Material & Labour for horizontal boring below pavement/road, in soft/loose soil for crossing 50mm size GI pipe lines all as specified and as directed. 25 RM
33 33 Material and labour for Cutting of cast iron pipe in position for insertion of new tee ,branch 80 mm dia complelte all as specified and as directed. 1 Each
34 34 Material and labour for Rotational moulded polyethylene water storage tanks of capacity 24,000 Ltrs (in case of two nos tank min capacity must be 12000Ltrs each) (cylindrical vertical with closed top) hoisted and fixed in position with and including necessary foundation of brick and PCC and making connection all as specified and directed . Make:- Sintex/Vectus or equivalents. 1 Each Job
35 35 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. 319 Cum
36 36 Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed. 243 Cum
37 37 Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and as directed. 76 Cum
38 38 External Electrification\nHorizontal Boring for passing GI protection pipe up to 80 mm bore (dia), under road / foot path, not exc. 10.00 metre in a single length, complete all as specified and as directed. 18 RM
39 39 S&F Galvanised Iron Pipe 80mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed.\nMake : JINDAL/BANSAL/NTL. 18 RM
40 40 M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. \n(NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid for). 38 Cum
41 41 S&F Sub-Class B brick, well burnt, laid breadth-wise along the axis of Cable laid in Trenches over Sand Cushion laid for UG Cable protection, complete all as specified and as directed 3680 Each
42 42 Supply and Install testing and commissioning of silent type 380KVA DG set of following rating with outdoor type AMF panel & acoustic enclosure panel conforming to latest enviroment protection regulations for emission and noise level comprising of radiator, water cooled, vertical multi-cylinder disel engine equipped with fly weels, inbuilt disel tank for contineous 08 hrs running at full load in enclosure with level controller and residential type exhaust silencer with suitable exhaust extension pipes from DG engine to top of the sub station building as per pollution control requirement and fitted with facility for auto/manual start with electrical starting equipements directly coupled to alternator of brushless, self excited, self regulated suitable for contineous operation at 1500RPM at 0.8 lagging p.f 3Phase, 50 Hz, 415V 4wire AC supply complete with base plate, antivibration pads, power & control cabilig etc as detailed in the specification and as required. Installation of DG sets on the foundation and including foundation providing necessary anti-vibration mounting battery and battary statnd including first filling of lub oil, filling of diesel for testing and commisioning & necessary load testing & commisioning. 1 Each Job
43 43 Supply laying & testing LT electric cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 3½ core 300 sq mm. 500 RM
44 44 M&L Earthing with Galvanised Steel Earth Plate Electrode 600X600X6.0mm thick, buried directly in Ground (Earth Pit not less than 2.25 METRE deep below Ground Level) with Top Edge of the Plate not less than 1.50 METRE below Normal Ground Level connected to GI strip 32x6mm Earthing Lead upto 7.5 METRE from Testing Point by means of Bolts, Nuts, Check Nuts and Washers of Galvanised Iron or Steel, Earth Plate Electrode surrounded by a packed thickness of Char Coal mixed with Common Salt in alternate layers of not exc.150mm thick, Aluminium Strip protected with and including GI Pipe 40mm Bore (dia) ‘Medium Grade’ for mechanical protection including PCC Pit in Cement Concrete (1:3:6) Type C1 (20mm Graded Stone Aggregate) and Pre-Cast RCC Cover of Size 450X450X50mm in RCC (1:2:4) Type B1 (20mm Graded Stone Aggregate) with Mild Steel Round Bar 10mm Handle of suitable Size, Reinforced with and including 8.0mm dia TMT Bars @ 100mm Centre to Centre both ways GI Wire Mesh, Funnel, GI Watering Pipe 20mm Bore (dia) Medium Grade, necessary Excavation in Soft/Loose Soil, Returning Filling in and Removal of Surplus Spoil upto a distance of 50.00 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion including Taking down Unserviceable Earthing, complete all as specified and as directed. 4 Each
45 45 M&L for earthing with copper earth plate electrode 300 x 300 x 3 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to copper strip of size 25x3 mm as earthing lead means of nut, bolts and washers made out of galvanised ireon mild steel and 40 mm dia GI pipe "medium grade" for protection of earth lead and connected to Transformer / DG Set Neutral/body or as directed by Engr -in-Charge including PCC Pit in Cement Concrete 1:3:6 (20mm Graded Stone Agg-regate) and RCC Cover of size 450X450X50mm in RCC 1:2:4 (20mm Graded Stone Aggregate) rein-forced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, Galvanised Iron Wire Mesh, Funnel, Galvanised Iron Watering Pipe 20mm Bore (dia) light Grade, necessary Excavation in Soft/ Loose Soil, returning, filling in and removal of surplus Spoil upto a distance of 50.00 metre and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and Testing on completion including Taking down Unserviceable Earthing, complete all as specified and as directed. 2 Each Job
46 46 S&F of cubical housing cabinet type LT feeder pillor box indoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 14 SWG (2mm) thick CRCA MS Sheet of overall size 2500 mm (height) x 2500 mm (width) x 900 mm (depth) and built upon suitable size angle iron frame work , having front and rear hinged doors,GI earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply powder coated paint (RAL-7032) The panel should be suitable for 415 volts , 50Hz, 3 phase 4 wire system and internal connection should be provided with copper strips of suitable size and necessary foundation work and comprising following:- \nNote: All Internal connection of MCCB from BUS Bar made By using copper busbar of rated Capacity\nINCOMING\n(a) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid copper bus bars, rated 2200 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - SET OF 4, 1 No. \n(b) ACB 800 amps, 415 volt, 50 KA Breaking capacity 4 pole duly connected to bus bar as in coming -01 Nos. 1 Each Job
47 47 Item No 46 Contd//-\nOUTGOING\n(c) MCCB 630 amps, 415 volt, 50 KA Breaking capacity 4 pole duly connected to bus bar As in coming -02 Nos (for AC Panel-01 & Spare-01).\n(d) MCCB 400 amps , 415 volt, 50 KA Breaking capacity 4 pole duly connected to Bus Bar As out going - 01 No \nINDICATING DEVICES\n(a) LED Indicating lamps for Main Supply indicating R', Y' B' - Set of 3.\n(b) Digital Voltmeter (96mmx96mm) 0-500 Volt with selector switch of 10Amps -1No\n(c) Current Transformer having Ratio 1200/5 burden 15 VA - SET OF 3.\n(d) Digital Ammeter 0 to 1200 Amps with selector switch \n(Make: L&T/ Havells) - 1 No.\n(e) Control MCB 2.0 Amps- 2 No.\n
48 48 CENTRAL AC PLANT\nSupply, Installation, Testing and Commissioning of water-cooled scroll chiller with multi compressors, comprising of Hermetic compressors, DX Evaporator, shell & tube condenser, suitable expansion device, suitable for operation on R-407C refrigerant and complete in all respects as required for 62.5 TR (2 working +1 stand by) actual Cooling Capacity.\n\nWater Temperature IN - 54.0 deg F\nWater Temperature OUT - 44.0 deg F\nFouling Factor - 0.0005 FPS\n\nCondenser :\nWater Temperature IN - 90.0 deg F\nWater Temperature OUT - 97.5 deg F\nFouling Factor - 0.001 FPS\n\nWater flow rate through Chiller - 150 USGPM\nWater flow rate through Condenser - 250 USGPM\nNote 1 :-\n(a) Contractor / bidder needs to check the desired inside design conditions carefully and submit the bid only after ascertaining the capacity of the AC plant required to achieve the inside design conditions. \n(b) Contractor / bidder should submit complete design for the Central AC plant comprising of heat load calculations, working drawings of complete AC plant supported with design/calculations of each component duly vetted by IIT/NIT within two months of the date of commencement of work through GE for the approval of Accepting Officer before execution of the work.\n 3 Each Job
49 49 (c) Contractor/bidder will be responsible for performance guarantee of complete AC plant to achieve the inside design conditions round the clock throughout the year with overall COP of the system not less than 3. \n(d) Design, Supply, Installation, Testing and Commissioning of Chilled water Central Air-conditioning system shall be undertaken through Manufacturers/ Specialist Firms.\nNote 2 :- All the rates quoted by the contractor shall be complete for finished work including cost of all labour, material, scaffolding, finishing as required with tools, plants, cartage, lift, taxes, tolls, octroi, royalties etc. except those especially excluded in the description of the individual items. All works shall be executed as per drawings and instructions of Engineer-in-charge and shall include the supply and installation at site of all the equipment, ancillary materials as specified and all such items what-so-ever which may be required to fulfil the intent and purpose as laid down in the drawings. All materials shall be as per ISI specification and with IS certification marked wherever applicable. The material shall be duly approved by Engineer-in-charge before incorporation in the actual work.
50 50 Supply, Erection, Testing and Commissioning of split-casing end-suction type Chilled water primary pump set capable of delivering 150 USGPM of water against 12 mtr head comprising of the following and complete as required. (2 working + 1 standby) \n(i) 1 no. - split-coupled type single-stage Pump with bronze impeller, S.S Shaft, CI body and mechanical seal\n(ii) 1 no. suitable HP, TEFC squirrel cage motor (IE-2) with class 'F' insulation, 2900/1450 RPM synchronous speed, operating at 415 ± 10 % Volts, 3 phase, 50 Hz A.C. supply; Minimum Efficiency 75%.\n(iii) Duly insulated with 32 mm thick closed cell elastomeric nitrile rubber insulation cladded with aluminium sheets of 0.63mm thickness and properly clamped to pump in two semi-circular sections as required\n(iv) Pump casing should be PN-16 rated & tested at 1.5 times higher pressure than the designed pressure.\n(v) Lot-Mounting frame work with anti-vibration pads 3 Each Job
51 51 Supply, Erection, Testing and Commissioning of split-casing end suction Secondary Chilled water pumping system( 2 working+1 standby), with VFD and all pump system controller, comprising of:\n (a) Vertical Inline split coupled type single stage pumping set with cast iron casing, bronze impellers with stainless steel shaft, connected to suitable capacity TEFC ventilated induction motor (IE-2) with class' F' insulation of 3 phase, 2900/1450 RPM, suitable for 415 volts +10%, 3 phase, 50 Hz A.C. supply. \n(b) Duly insulated with 32 mm thick closed cell elastometric nitrile rubber insulation cladded with aluminium sheets of 0.63 mm thickness and properly clamped to pump in two semicircular sections as required.\n(c) Variable secondary Panel should have a dedicated Programmable Logic Controller, with individual drive for each pump and with required nos. of sensors and the entire unit has to be procured from the Pump manufacturer to ensure the smooth operation of the system. The Programmable Logic Controller shall be able to control minimum 1 Pump and maximum of 3 to 4 Pumps, Automatic cascade control of pumps, automatic sequence change, Friction loss compensation, pump status shall be provided. Display shall be graphical type with minimum 320 pixels X 240 Pixels VGA display with backlight. Drive should have rated input frequency 50 Hz and output frequency range of 0.5 to 132 Hz. An IP55 Nema Standard powder coated steel enclosure with sufficient capacity of cooling fan shall house all the electrical control components. 3 Each Job
52 52 (d) Electrical Control Panel capable of cyclic operation of pumps - Pump working sequence should change after every operation. Control panel with programmable logic controller (PLC) with inbuilt PID controller, digital display with fluorescent screen with two lines of min. 20 character each and equipped with function keys and service keys. 3 ph, 415 (±10%)V, AC variable speed drive for each pump of suitable capacity rating having standard function of BI loop, controlled stop on loss of supply power loss side through, DDC injection breaking fast stop. Drive should have rated input frequency 50 Hz and output frequency range of 0.5 to 132 Hz. \n(e) Microprocessor-based Control Panel shall have suitable hardware & software so that it can be integrated directly to iBMS with standard communication open protocol using BACnet / MODBUS as well as open IP.\n(f) All pumps to be provided with separate variable frequency drives. Control panel should also consist of cooling fan. (All the Pump set will have their control panel with respect to the motor rating).\n(g) All necessary Electronic Differential Pressure Transmitters and control wiring as required.\n(h) Pump casing should be PN 16 rated & tested at 1.5 times higher pressure then the designed pressure.\n(i) Lot-Mounting frame work with anti vibration pads.\nNote :- Flow Rate (USGPM) : 150, Pump Head (m) : 20, Minimum Efficiency : 75 %\n
53 53 Control Panel for Secondary Chilled Water Pump 1 Each
54 54 Differential Pressure Transmitter for Load 1 Each
55 55 Supply, Installation, Testing and Commissioning of end suction centrifugal Condenser water pump set (2 working+ 1 standby) capable of delivering 250 USGPM of water against 18 mtr WG head each comprising of the following and complete as required:- \n(a) 1 No. - Pump with bronze impeller, S.S Shaft, CI body and mechanical seal\n(b) 1 No. suitable HP, TEFC squirrel cage induction motor (IE-2) with class 'F' insulation, 2900/1450 RPM synchronous speed, operating on 415 ± 10 % Volts, 3 phase, 50 Hz A.C. supply; Minimum Efficiency 75%.\n(c) Lot-Mounting frame work with anti vibration pads\n 3 Each
56 56 Supply, Erection, Testing and Commissioning of Mono block pump for hot water capable of delivering of water against head, each comprising of 56.74 USGPM capacity of water against 16 mtr WG head (1 working + 1 standby) for OT's and Burn OT's and complete as required:-\n(a) 1 No. - Mono block type pump with bronze impeller and mechanical seal.\n(b) Lot - Closed cell nitrile rubber insulation of not less than 32 mm thick duly cladded between aluminium sheets of 0.63 mm thickness and properly clamped to pump in two semicircular sections as required.\n(c) 1 No. suitable HP, TEFC squirrel cage induction motor(IE-2) with class ' F' insulation, 3000 RPM synchronous speed, operating on 415 Volts + 10 % , 3 phase, 50 Hz A.C supply. 2 Each
57 57 Supply, Erection, Testing and Commissioning of Mono block pump for hot water capable of delivering of water against head, each comprising of 34.0 USGPM capacity of water against 16 mtr WG head (1 working + 1 standby) for Other Areas and complete as required:-\n(a) 1 No. - Mono block type pump with bronze impeller and mechanical seal.\n(b) Lot - Closed cell nitrile rubber insulation of not less than 32 mm thick duly cladded between aluminium sheets of 0.63 mm thickness and properly clamped to pump in two semicircular sections as required.\n(c) 1 No. suitable HP, TEFC squirrel cage induction motor(IE-2) with class ' F' insulation, 3000 RPM synchronous speed, operating on 415 Volts + 10 % , 3 phase, 50 Hz A.C supply. 34.0 USGPM of water against 16 mtr WG head (1 working + 1 standby) for Other Areas 2 Each
58 58 Supply, Installation, Testing and Commissioning of electrically operated Hot Water Generator of following actual capacity; made of 8 mm M.S. sheet and dish end made of 10mm M.S. having 16 gauge stainless steel lining with heaters arranged in banks and Controller and Thermostat so that required qty. of hot water is generated at 50°C with nominal variation, including 100mm thick resin-bonded fiber glass insulation of 24 kg / cum. density finished with 1.25mm thick aluminium sheet cladding including necessary Electrical panel with automatic controls including inlet and outlet connections for water complete with pressure release valve, low level cut-out, Autovent sight-glass as per specifications complete as required. \n(Degree of protection IP-52 with IS 2147)\n(a) Heating capacity : 75 kW (for OTs and Burn OTs)\n(b) Water in temp. : 45 deg C\n(c) Water out temp : 50 deg C\n(d) Flow Rate : 56.74 USGPM \n\n 1 Each
59 59 Supply, Installation, Testing and Commissioning of electrically operated Hot Water Generator of following actual capacity; made of 8 mm M.S. sheet and dish end made of 10mm M.S. having 16 gauge stainless steel lining with heaters arranged in banks and Controller and Thermostat so that required qty. of hot water is generated at 50°C with nominal variation, including 100mm thick resin-bonded fiber glass insulation of 24 kg / cum. density finished with 1.25mm thick aluminium sheet cladding including necessary Electrical panel with automatic controls including inlet and outlet connections for water complete with pressure release valve, low level cut-out, Autovent sight-glass as per specifications complete as required. \n(Degree of protection IP-52 with IS 2147)\n(a) Heating capacity : 45 kW (for OTs and Burn OTs)\n(b) Water in temp. : 45 deg C\n(c) Water out temp : 50 deg C\n(d) Flow Rate : 34 USGPM 1 Each
60 60 Supply, Installation, Testing and Commissioning of induced draft counter flow, vertical discharge-type FRP Cooling tower of 2.36 lakhs kCal/hr heat rejection capacity with ultra-violet treated durable & highly efficient PVC fillings with integral louvers and drift eliminators, open pan suitable for water distribution complete with hot FRP water basin. The hot water shall be distributed to fills in each cell via open-type gravity basin or with spray nozzles or having self-rotating sprinklers. Cooling tower shall be provided with statically and dynamically balanced two nos. anti-corrosion treated axial flow type fan - direct-driven or driven through special bevelled reduction gear box with TEFC induction motor with IP-65 protection, IE-2, suction screen, make up and quick fill arrangement, overflow and drain connections and suitably inspected hot-dipped galvanized ladder, access arrangement for cooling tower interior, anti vibration mountings etc., complete as required. The cooling tower capacity should be certified by CTI/JCI. The unit shall be installed at proper foundation as per requirements. \n(Civil foundation works is not included in the item, shall be in the scope of civil contractor)\n(a) Water Leaving Temperature : 90 deg F\n(b) Water Entering Temperature : 97.5 deg F\n(c) Water Flow Rate : 250 USGPM\n(d) Ambient Wet Bulb Temperature : 82.6 deg F 2 Each
61 61 Supply, Installation, Testing and Commissioning of steam-Type Humidifier package of 12.0 kW with suitable humidistat as required. (The humidifier shall be interlocked with thermostat of RH sensor) suitable for outdoor installation. 2 Each
62 62 Supply, Installation, Testing and Commissioning of steam-Type Humidifier package of 9.0 kW with suitable humidistat as required. (The humidifier shall be interlocked with thermostat of RH sensor) suitable for outdoor installation. 1 Each
63 63 Supply, Installation, Testing and Commissioning of steam-Type Humidifier package of 6.0 kW with suitable humidistat as required. (The humidifier shall be interlocked with thermostat of RH sensor) suitable for outdoor installation. 5 Each
64 64 Supply, Installation, Testing and Commissioning of factory built Floor-standing double-skin type air handling unit of 9700 CFM / 31.0 TR capacity made of 25 mm thick panels consisting of pre-plasticized G.I. casing of thickness 0.6 mm at outside layer and 0.6 mm thick plain aluminium. sheet at inside layer with polyurethane foam (PUF) insulation of density 40(+2) kg/m3 factory injected between them by injection moulding machine, complete with blower section with Direct Driven plug fan of 65mm WG static pressure. The unit shall consist of 4/6 rows deep cooling coil & 2 rows deep heating coil with aluminium finned copper tubes, filter sections with 50 mm thick washable synthetic type Pre-filters having efficiency 90% down to 10 micron, Fine filters having efficiency 99% down to 5 micron, direct-driven package with TEFC drive motor (IE-2) suitable for VFD application at 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, complete with drain connections with drain valve, stainless steel drain pan, necessary vibration isolation arrangement (spring-loaded), silicon-coated flexible duct connector etc., complete as as directed.\nThe AHU should have space for humidifier.\nVFD panel with VFD (quantified separately), necessary control arrangement to switch off the fan in case of fire, indicating lamp & all safety precautions in a flame-proof powder-coated MS enclosure with necessary power and control cable as required. 1 Each
65 65 Supply, Installation, Testing and Commissioning of factory built Floor-standing double-skin type air handling unit of 5500 CFM / 18.0 TR capacity made of 25 mm thick panels consisting of pre-plasticized G.I. casing of thickness 0.6 mm at outside layer and 0.6 mm thick plain aluminium. sheet at inside layer with polyurethane foam (PUF) insulation of density 40(+2) kg/m3 factory injected between them by injection moulding machine, complete with blower section with Direct Driven plug fan of 65mm WG static pressure. The unit shall consist of 4/6 rows deep cooling coil & 2 rows deep heating coil with aluminium finned copper tubes, filter sections with 50 mm thick washable synthetic type Pre-filters having efficiency 90% down to 10 micron, Fine filters having efficiency 99% down to 5 micron, direct-driven package with TEFC drive motor (IE-2) suitable for VFD application at 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, complete with drain connections with drain valve, stainless steel drain pan, necessary vibration isolation arrangement (spring-loaded), silicon-coated flexible duct connector etc., complete as directed.\nThe AHU should have space for humidifier.\nVFD panel with VFD (quantified separately), necessary control arrangement to switch off the fan in case of fire, indicating lamp & all safety precautions in a flame-proof powder-coated MS enclosure with necessary power and control cable as required. 1 Each
66 66 Supply, Installation, Testing and Commissioning of double skin construction, horizontal floor mounted in two tier construction blow-through type chilled water Air handling units for burn OT No.1 of 1422 CFN/7.15 TR capacity fabricated out of extruded aluminium section with 0.8 mm pre-plasticized / pre-coated galvanised steel sheet outside & 0.8 mm polished SS-304 sheet inside each, complete with modules as listed below. The AHU panels shall be minimum 43 mm thick & insulated with 40 (± 2) kg/m³ density compressed glass wool & shall have thermal break profile. Total static pressure shall be checked by vendor. Change in static pressure will not attract any price implication.The AHU shall be complete in all respects along with accessories as per specifications. The capacity of Air-handlers shall be as follows:\nSUPPLY AIR STREAM (LOWER TIER)\n(i) Fresh Air Intake section with manual type low leakage Aluminium aerofoil gear driven VCD with 50mm thick pre filters (washable type) of non-woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8). Filter frame shall be made of Aluminium only.\n(ii) Fan section with direct driven Plug fan (minimum 75%) with lowest sound level for the design duty conditions; suitable to work in varying static pressure range (due to 3 stage filtration IPD to FPD). Plug type fan shall be complete with motor, vibration isolators and VFD. Fan shall be suitable to deliver 1422 CFM at total static pressure of 125 mm WG. Motor shall be atleast IE-3 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. The motor & blower assembly shall be mounted on extruded aluminium section only. 1 Each
67 67 (iii) Heat recovery section with enthalpy type heat reclaim wheel . The wheel shall have minimum 75% both sensible and latent balanced effectiveness and performance shall be AHRI certified. Wheel shall also be certified for 0% fungal and bacterial growth at 95% RH and above.Wheel shall be selected for minimum pressure drop to handle the 1422 cfm and maximum face velocity. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. Design conditions shall be Supply air: 1422 cfm at 93.0 DB degF/WB 82.0 Deg F during summer & DB 90.5 deg F/82.6 DegF during monsoon and Return/Exhaust air: 1364 cfm at DB 83 deg F /RH 70% . \n(iv) Cooling coil section having 8 rows deep chilled water coil and 2 rows deep hot water coil for winter heating and monsoon reheat. Cooling coils shall be constructed of copper tube & aluminium fins construction alongwith di- electric union. Coil shall have copper header and supporting frame work / end plates in SS 304 construction, polished SS 304 drain pan made out of 22G sheet duly insulated with 25mm thick nitrile rubber. Sufficient space shall be made available between the 2 nos. coil for cleaning/maintenance and shall be provided with required access doors. Coil size shall be selected for a maximum face velocity of 450 feet/minute and performance shall be AHRI certified.
68 68 (v) 8 rows cooling coil shall be suitable to deliver 7.15 TR capacity with ON coil conditions of DB 93 deg F/ WB 82 deg F with a flow rate of 17.16 USGPM maximum.\n(vi) 2 rows Hot water coil shall be suitable to deliver minimum 8.0 kW capacity with ON coil conditions of DB 50 deg F/ WB 49 deg F during winter conditions.Hot water IN at 45 deg C and flow rate of 6.0 GPM maximum.\n(vii) Humidifier section comprising of steam type humidfier of 12 kW capacity.\n(viii) Discharge plenum comprising of 300mm thick bag type fine filters (dry-cleanable type with high pressure blower) of non-woven synthetic media (efficiency 99% down to 3 microns complying to MERV-14) Filter frame shall be made of Aluminium only. At the outlet of discharge section, fire resistance Neoprene flexible connections shall be provided for connection with duct.\nNote: Hepa filters shall be at terminals along with laminar flow plenum & shall not be included in the AHU cost.\nEXHAUST / RETURN AIR STREAM (UPPER-TIER)\n(i) Return Air Intake section comprising of frame mounted 50mm thick pre filters (washable type) of non-woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8) . Filter frame shall be made of Aluminium only. At the inlet of the section, fire resistance Neoprene flexible connections shall be provided for connection with duct.\n(ii) Heat recovery section with enthalpy type heat reclaim wheel. The wheel shall have minimum 75% both sensible and latent balanced effectiveness and performance shall be AHRI certified. Wheel shall also be certified for 0% fungal and bacterial growth at 95% RH and above.Wheel shall be selected for minimum pressure drop to handle the 1422 cfm and maximum face velocity. Motor shall be atleast IE 3 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. DOL starter shall be included as per the specifications. Design conditions shall be Supply air: 1422cfm at DB 93 deg F/WB 82 deg F during summer & DB 90.5 deg F/82.6 deg F during monsoon and Return/Exhaust air: 1364 cfm at DB 83 deg F /RH 70% .
69 69 (iii) Fan section with direct driven Plug fan (minimum 75%) with lowest sound level for the design duty conditions; suitable to work in varying static pressure range (due to 3 stage filtration IPD to FPD). Plug type fan shall be complete with motor, vibration isolators and VFD. Fan shall be suitable to deliver 1422 cfm at total static pressure of 40mm WC. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. The motor & blower assembly shall be mounted on extruded aluminium section only.\n(iv) Discharge plenum comprising of frame mounted 300mm thick bag type fine filters (dry-cleanable type with high pressure blower) of non woven synthetic media (efficiency 99% down to 3 microns complying to MERV-14). Filter frame shall be made of Aluminium only. It shall also have face & by pass dampers between the lower & upper tier and at the outlet.The dampers shall be opposed blade manual type low leakage Aluminium aerofoil gear driven VCD. \nNote:- The above AHU shall have provision of space for installation of steam type humidifier package & have remote control provision in the OT for temp. & RH adjustment. (The AHU shall be interlocked with digital temp. & RH controller)
70 70 Supply, Installation, Testing and Commissioning of double skin construction, horizontal floor mounted in two tier construction blow-through type chilled water Air handling unit for Burn OT No 2 of 1395 CFM/7.12 TR capacity fabricated out of extruded aluminium section with 0.8 mm pre-plasticized / pre-coated galvanised steel sheet outside & 0.8 mm polished SS-304 sheet inside each, complete with modules as listed below. The AHU panels shall be minimum 43 mm thick & insulated with 40 (± 2) kg/m³ density compressed glass wool & shall have thermal break profile. Total static pressure shall be checked by vendor. Change in static pressure will not attract any price implication.The AHU shall be complete in all respects along with accessories as per specifications. The capacity of Air-handlers shall be as follows:-\nSUPPLY AIR STREAM (LOWER TIER)\n(i) Fresh Air Intake section with manual type low leakage Aluminium aerofoil gear driven VCD with 50mm thick pre filters (washable type) of non-woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8). Filter frame shall be made of Aluminium only.\n(ii) Fan section with direct driven Plug fan (minimum 75%) with lowest sound level for the design duty conditions; suitable to work in varying static pressure range (due to 3 stage filtration IPD to FPD). Plug type fan shall be complete with motor, vibration isolators and VFD. Fan shall be suitable to deliver 1395 CFM at total static pressure of 125 mm WG. Motor shall be atleast IE-3 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. The motor & blower assembly shall be mounted on extruded aluminium section only. 1 Each
71 71 (iii) Heat recovery section with enthalpy type heat reclaim wheel . The wheel shall have minimum 75% both sensible and latent balanced effectiveness and performance shall be AHRI certified. Wheel shall also be certified for 0% fungal and bacterial growth at 95% RH and above.Wheel shall be selected for minimum pressure drop to handle the 1395 cfm and maximum face velocity. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. Design conditions shall be Supply air: 1395 cfm at 93.0 DB deg F/WB 82.0 deg F during summer & DB 90.5 deg F/82.6 deg F during monsoon and Return/Exhaust air: 1341 cfm at DB 83 deg F /RH 70% . \n(iv) Cooling coil section having 8 rows deep chilled water coil and 2 rows deep hot water coil for winter heating and monsoon reheat. Cooling coils shall be constructed of copper tube & aluminium fins construction alongwith di- electric union. Coil shall have copper header and supporting frame work / end plates in SS 304 construction, polished SS 304 drain pan made out of 22G sheet duly insulated with 25mm thick nitrile rubber. Sufficient space shall be made available between the 2 nos. coil for cleaning/maintenance and shall be provided with required access doors. Coil size shall be selected for a maximum face velocity of 450 feet/minute and performance shall be AHRI certified.\n(v) 8 rows cooling coil shall be suitable to deliver 7.12 TR capacity with ON coil conditions of DB 93 deg F/ WB 82 deg F with a flow rate of 17.088 USGPM maximum.\n(vi) 2 rows Hot water coil shall be suitable to deliver minimum 8.0 kW capacity with ON coil conditions of DB 50 deg F/ WB 49 deg F during winter conditions. Hot water IN at 45 deg C and flow rate of 6.0 GPM maximum.\n(vii) Humidifier section comprising of steam type humidfier of 12 kW capacity\n
72 72 (viii) Discharge plenum comprising of 300mm thick bag type fine filters (dry-cleanable type with high pressure blower) of non-woven synthetic media (efficiency 99% down to 3 microns complying to MERV-14) Filter frame shall be made of Aluminium only. At the outlet of discharge section, fire resistance Neoprene flexible connections shall be provided for connection with duct.\nNote:- Hepa filters shall be at terminals along with laminar flow plenum & shall not be included in the AHU cost.\n
73 73 EXHAUST / RETURN AIR STREAM (UPPER-TIER)\n(i) Return Air Intake section comprising of frame mounted 50mm thick pre filters (washable type) of non woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8) . Filter frame shall be made of Aluminium only. At the inlet of the section, fire resistance Neoprene flexible connections shall be provided for connection with duct.\n(ii) Heat recovery section with enthalpy type heat reclaim wheel. The wheel shall have minimum 75% both sensible and latent balanced effectiveness and performance shall be AHRI certified. Wheel shall also be certified for 0% fungal and bacterial growth at 95% RH and above.Wheel shall be selected for minimum pressure drop to handle the 1395 cfm and maximum face velocity. Motor shall be atleast IE 3 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. DOL starter shall be included as per the specifications. Design conditions shall be Supply air: 1395 cfm at DB 93 deg F/WB 82 deg F during summer & DB 90.5 deg F/82.6 deg F during monsoon and Return/Exhaust air: 1341 cfm at DB 83 deg F /RH 70% . \n(iii) Fan section with direct driven Plug fan (minimum 75%) with lowest sound level for the design duty conditions; suitable to work in varying static pressure range (due to 3 stage filtration IPD to FPD). Plug type fan shall be complete with motor, vibration isolators and VFD. Fan shall be suitable to deliver 1395 cfm at total static pressure of 40mm WC. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. The motor & blower assembly shall be mounted on extruded aluminium section only.\n
74 74 (iv) Discharge plenum comprising of frame mounted 300mm thick bag type fine filters (dry-cleanable type with high pressure blower) of non-woven synthetic media (efficiency 99% down to 3 microns complying to MERV-14). Filter frame shall be made of Aluminium only. It shall also have face & by-pass dampers between the lower & upper tier and at the outlet.The dampers shall be opposed blade manual type low leakage Aluminium aerofoil gear driven VCD. \nNote:- The above AHU shall have provision of space for installation of steam type humidifier package & have remote control provision in the OT for temp. & RH adjustment. (The AHU shall be interlocked with digital temp. & RH controller)
75 75 Supply, Installation, Testing and Commissioning of double skin construction, horizontal floor mounted in two tier construction blow-through type chilled water Air handling unit for OT No. 1 of 2297 CFM/10.22 TR capacity fabricated out of extruded aluminium section with 0.8 mm pre-plasticized / pre-coated galvanised steel sheet outside & 0.8 mm polished SS-304 sheet inside each, complete with modules as listed below. The AHU panels shall be minimum 43 mm thick & insulated with 40 (± 2) kg/m³ density compressed glass wool & shall have thermal break profile. Total static pressure shall be checked by vendor. Change in static pressure will not attract any price implication.The AHU shall be complete in all respects along with accessories as per specifications. The capacity of Air-handlers shall be as follows:-\nSUPPLY AIR STREAM (LOWER TIER)\n(i) Fresh Air Intake section with manual type low leakage Aluminium aerofoil gear driven VCD with 50mm thick pre filters (washable type) of non-woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8). Filter frame shall be made of Aluminium only. \n(ii)Fan section with direct driven Plug fan (minimum 75%) with lowest sound level for the design duty conditions; suitable to work in varying static pressure range (due to 3 stage filtration IPD to FPD). Plug type fan shall be complete with motor, vibration isolators and VFD. Fan shall be suitable to deliver 2297 CFM at total static pressure of 125 mm WG. Motor shall be atleast IE-3 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. The motor & blower assembly shall be mounted on extruded aluminium section only. 1 Each
76 76 (iii) Heat recovery section with enthalpy type heat reclaim wheel . The wheel shall have minimum 75% both sensible and latent balanced effectiveness and performance shall be AHRI certified. Wheel shall also be certified for 0% fungal and bacterial growth at 95% RH and above.Wheel shall be selected for minimum pressure drop to handle the 2297 cfm and maximum face velocity. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. Design conditions shall be Supply air: 2295 cfm at 93.0 DB deg F/WB 82.0 deg F during summer & DB 90.5 deg F/82.6 deg F during monsoon and Return/Exhaust air: 2106 cfm at DB 78.0 deg F /RH 57% . \n(iv) Cooling coil section having 8 rows deep chilled water coil and 2 rows deep hot water coil for winter heating and monsoon reheat. Cooling coils shall be constructed of copper tube & aluminium fins construction alongwith di- electric union. Coil shall have copper header and supporting frame work / end plates in SS 304 construction, polished SS 304 drain pan made out of 22G sheet duly insulated with 25mm thick nitrile rubber. Sufficient space shall be made available between the 2 nos. coil for cleaning/maintenance and shall be provided with required access doors. Coil size shall be selected for a maximum face velocity of 450 feet/minute and performance shall be AHRI certified.
77 77 (v) 8 rows cooling coil shall be suitable to deliver 10.82 TR capacity with ON coil conditions of DB 93 deg F/ WB 82 deg F with a flow rate of 25.968 USGPM maximum.\n(vi) 2 rows Hot water coil shall be suitable to deliver minimum 12.6 kW capacity with ON coil conditions of DB 50 deg F/ WB 49 deg F during winter conditions. Hot water IN at 45 deg C and flow rate of 9.53 GPM maximum.\n(vii) Humidifier section comprising of steam type humidfier of 6 kW capacity.\n(viii) Discharge plenum comprising of 300mm thick bag type fine filters (dry-cleanable type with high pressure blower) of non-woven synthetic media (efficiency 99% down to 3 microns complying to MERV-14) Filter frame shall be made of Aluminium only. At the outlet of discharge section, fire resistance Neoprene flexible connections shall be provided for connection with duct.\nNote: Hepa filters shall be at terminals along with laminar flow plenum & shall not be included in the AHU cost.\nEXHAUST / RETURN AIR STREAM (UPPER-TIER)\n(i) Return Air Intake section comprising of frame mounted 50mm thick pre filters (washable type) of non woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8) . Filter frame shall be made of Aluminium only. At the inlet of the section, fire resistance Neoprene flexible connections shall be provided for connection with duct.\n
78 78 (ii) Heat recovery section with enthalpy type heat reclaim wheel. The wheel shall have minimum 75% both sensible and latent balanced effectiveness and performance shall be AHRI certified. Wheel shall also be certified for 0% fungal and bacterial growth at 95% RH and above.Wheel shall be selected for minimum pressure drop to handle the 2297 cfm and maximum face velocity. Motor shall be atleast IE 3 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. DOL starter shall be included as per the specifications. Design conditions shall be Supply air: 1395 cfm at DB 93 deg F/WB 82 deg F during summer & DB 90.5 deg F/82.6 deg F during monsoon and Return/Exhaust air: 2106 cfm at DB 78.0 deg F /RH 57% . \n(iii) Fan section with direct driven Plug fan (minimum 75%) with lowest sound level for the design duty conditions; suitable to work in varying static pressure range (due to 3 stage filtration IPD to FPD). Plug type fan shall be complete with motor, vibration isolators and VFD. Fan shall be suitable to deliver 2297 cfm at total static pressure of 40mm WC. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. The motor & blower assembly shall be mounted on extruded aluminium section only.\n(iv) Discharge plenum comprising of frame mounted 300mm thick bag type fine filters (dry-cleanable type with high pressure blower) of non-woven synthetic media (efficiency 99% down to 3 microns complying to MERV-14). Filter frame shall be made of Aluminium only. It shall also have face & by-pass dampers between the lower & upper tier and at the outlet.The dampers shall be opposed blade manual type low leakage Aluminium aerofoil gear driven VCD. \nNote: The above AHU shall have provision of space for installation of steam type humidifier package & have remote control provision in the OT for temp. & RH adjustment. (The AHU shall be interlocked with digital temp. & RH controller)
79 79 Supply, Installation, Testing and Commissioning of double skin construction, horizontal floor mounted in two tier construction blow-through type chilled water Air handling unit of 2143 CFM/11.52 TR capacity fabricated out of extruded aluminium section with 0.8 mm pre-plasticized / pre-coated galvanised steel sheet outside & 0.8 mm polished SS-304 sheet inside each, complete with modules as listed below. The AHU panels shall be minimum 43 mm thick & insulated with 40 (± 2) kg/m³ density compressed glass wool & shall have thermal break profile. Total static pressure shall be checked by vendor. Change in static pressure will not attract any price implication.The AHU shall be complete in all respects along with accessories as per specifications. The capacity of Air-handlers shall be as follows:-\nSUPPLY AIR STREAM (LOWER TIER)\n(i) Fresh Air Intake section with manual type low leakage Aluminium aerofoil gear driven VCD with 50mm thick pre filters (washable type) of non-woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8). Filter frame shall be made of Aluminium only.\n(ii) Fan section with direct driven Plug fan (minimum 75%) with lowest sound level for the design duty conditions; suitable to work in varying static pressure range (due to 3 stage filtration IPD to FPD). Plug type fan shall be complete with motor, vibration isolators and VFD. Fan shall be suitable to deliver 2143 CFM at total static pressure of 125 mm WG. Motor shall be atleast IE-3 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. The motor & blower assembly shall be mounted on extruded aluminium section only.\n 1 Each
80 80 (iii) Heat recovery section with enthalpy type heat reclaim wheel . The wheel shall have minimum 75% both sensible and latent balanced effectiveness and performance shall be AHRI certified. Wheel shall also be certified for 0% fungal and bacterial growth at 95% RH and above.Wheel shall be selected for minimum pressure drop to handle the 2143 cfm and maximum face velocity. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. Design conditions shall be Supply air: 2143 cfm at 93.0 DB deg F/WB 82.0 deg F during summer & DB 90.5 deg F/82.6 deg F during monsoon and Return/Exhaust air: 1970 cfm at DB 78.0 deg F /RH 57% . \n(iv) Cooling coil section having 8 rows deep chilled water coil and 2 rows deep hot water coil for winter heating and monsoon reheat. Cooling coils shall be constructed of copper tube & aluminium fins construction alongwith di- electric union. Coil shall have copper header and supporting frame work / end plates in SS 304 construction, polished SS 304 drain pan made out of 22G sheet duly insulated with 25mm thick nitrile rubber. Sufficient space shall be made available between the 2 nos. coil for cleaning/maintenance and shall be provided with required access doors. Coil size shall be selected for a maximum face velocity of 450 feet/minute and performance shall be AHRI certified.\n(v) 8 rows cooling coil shall be suitable to deliver 10 TR capacity with ON coil conditions of DB 93 deg F/ WB 82 deg F with a flow rate of 24 USGPM maximum.\n(vi) 2 rows Hot water coil shall be suitable to deliver minimum 11.52 kW capacity with ON coil conditions of DB 50 deg F/ WB 49 deg F during winter conditions. Hot water IN at 45 deg C and flow rate of 8.716 GPM maximum.\n(vii) Humidifier section comprising of steam type humidfier of 6 kW capacity.\n
81 81 (viii) Discharge plenum comprising of 300mm thick bag type fine filters (dry-cleanable type with high pressure blower) of non-woven synthetic media (efficiency 99% down to 3 microns complying to MERV-14) Filter frame shall be made of Aluminium only. At the outlet of discharge section, fire resistance Neoprene flexible connections shall be provided for connection with duct.\nNote: Hepa filters shall be at terminals along with laminar flow plenum & shall not be included in the AHU cost.\nEXHAUST / RETURN AIR STREAM (UPPER-TIER)\n(i) Return Air Intake section comprising of frame mounted 50mm thick pre filters (washable type) of non woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8) . Filter frame shall be made of Aluminium only. At the inlet of the section, fire resistance Neoprene flexible connections shall be provided for connection with duct.\n(ii) Heat recovery section with enthalpy type heat reclaim wheel. The wheel shall have minimum 75% both sensible and latent balanced effectiveness and performance shall be AHRI certified. Wheel shall also be certified for 0% fungal and bacterial growth at 95% RH and above.Wheel shall be selected for minimum pressure drop to handle the 2143 cfm and maximum face velocity. Motor shall be atleast IE 3 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. DOL starter shall be included as per the specifications. Design conditions shall be Supply air: 2143 cfm at DB 93 deg F/WB 82 deg F during summer & DB 90.5 deg F/82.6 deg F during monsoon and Return/Exhaust air: 1970 cfm at DB 78.0 deg F /RH 57% .
82 82 (iii) Fan section with direct driven Plug fan (minimum 75%) with lowest sound level for the design duty conditions; suitable to work in varying static pressure range (due to 3 stage filtration IPD to FPD). Plug type fan shall be complete with motor, vibration isolators and VFD. Fan shall be suitable to deliver 2143 cfm at total static pressure of 40mm WC. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. The motor & blower assembly shall be mounted on extruded aluminium section only.\n(iv) Discharge plenum comprising of frame mounted 300mm thick bag type fine filters (dry-cleanable type with high pressure blower) of non-woven synthetic media (efficiency 99% down to 3 microns complying to MERV-14). Filter frame shall be made of Aluminium only. It shall also have face & by-pass dampers between the lower & upper tier and at the outlet.The dampers shall be opposed blade manual type low leakage Aluminium aerofoil gear driven VCD. \nNote: The above AHU shall have provision of space for installation of steam type humidifier package & have remote control provision in the OT for temp. & RH adjustment. (The AHU shall be interlocked with digital temp. & RH controller)\n
83 83 Supply, Installation, Testing and Commissioning of double skin construction, horizontal floor mounted in two tier construction blow-through type chilled water Air handling unit for OT No.3 of 2365 CFM/11.22 TR capacity fabricated out of extruded aluminium section with 0.8 mm pre-plasticized / pre-coated galvanised steel sheet outside & 0.8 mm polished SS-304 sheet inside each, complete with modules as listed below. The AHU panels shall be minimum 43 mm thick & insulated with 40 (± 2) kg/m³ density compressed glass wool & shall have thermal break profile. Total static pressure shall be checked by vendor. Change in static pressure will not attract any price implication.The AHU shall be complete in all respects along with accessories as per specifications. The capacity of Air-handlers shall be as follows:-\nSUPPLY AIR STREAM (LOWER TIER)\n(i) Fresh Air Intake section with manual type low leakage Aluminium aerofoil gear driven VCD with 50mm thick pre filters (washable type) of non-woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8). Filter frame shall be made of Aluminium only.\n(ii) Fan section with direct driven Plug fan (minimum 75%) with lowest sound level for the design duty conditions; suitable to work in varying static pressure range (due to 3 stage filtration IPD to FPD). Plug type fan shall be complete with motor, vibration isolators and VFD. Fan shall be suitable to deliver 2365 CFM at total static pressure of 125 mm WG. Motor shall be atleast IE-3 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. The motor & blower assembly shall be mounted on extruded aluminium section only. 1 Each
84 84 (iii) Heat recovery section with enthalpy type heat reclaim wheel . The wheel shall have minimum 75% both sensible and latent balanced effectiveness and performance shall be AHRI certified. Wheel shall also be certified for 0% fungal and bacterial growth at 95% RH and above.Wheel shall be selected for minimum pressure drop to handle the 2265 cfm and maximum face velocity. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. Design conditions shall be Supply air: 2365 cfm at 93.0 DB deg F/WB 82.0 deg F during summer & DB 90.5 deg F/82.6 deg F during monsoon and Return/Exhaust air: 2175 cfm at DB 78.0 deg F /RH 57% . \n(iv) Cooling coil section having 8 rows deep chilled water coil and 2 rows deep hot water coil for winter heating and monsoon reheat. Cooling coils shall be constructed of copper tube & aluminium fins construction alongwith di- electric union. Coil shall have copper header and supporting frame work / end plates in SS 304 construction, polished SS 304 drain pan made out of 22G sheet duly insulated with 25mm thick nitrile rubber. Sufficient space shall be made available between the 2 nos. coil for cleaning/maintenance and shall be provided with required access doors. Coil size shall be selected for a maximum face velocity of 450 feet/minute and performance shall be AHRI certified.\n(v) 8 rows cooling coil shall be suitable to deliver 11.22 TR capacity with ON coil conditions of DB 93 deg F/ WB 82 deg F with a flow rate of 26.9 USGPM maximum.\n(vi) 2 rows Hot water coil shall be suitable to deliver minimum 13.09 kW capacity with ON coil conditions of DB 50 deg F/ WB 49 deg F during winter conditions. Hot water IN at 45 deg C and flow rate of 9.9 GPM maximum.
85 85 (vii) Humidifier section comprising of steam type humidfier of 6 kW capacity.\n(viii) Discharge plenum comprising of 300mm thick bag type fine filters (dry-cleanable type with high pressure blower) of non-woven synthetic media (efficiency 99% down to 3 microns complying to MERV-14) Filter frame shall be made of Aluminium only. At the outlet of discharge section, fire resistance Neoprene flexible connections shall be provided for connection with duct.\nNote: Hepa filters shall be at terminals along with laminar flow plenum & shall not be included in the AHU cost.\nEXHAUST / RETURN AIR STREAM (UPPER-TIER)\n(i) Return Air Intake section comprising of frame mounted 50mm thick pre filters (washable type) of non woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8) . Filter frame shall be made of Aluminium only. At the inlet of the section, fire resistance Neoprene flexible connections shall be provided for connection with duct.\n(ii) Heat recovery section with enthalpy type heat reclaim wheel. The wheel shall have minimum 75% both sensible and latent balanced effectiveness and performance shall be AHRI certified. Wheel shall also be certified for 0% fungal and bacterial growth at 95% RH and above.Wheel shall be selected for minimum pressure drop to handle the 2365 cfm and maximum face velocity. Motor shall be atleast IE 3 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. DOL starter shall be included as per the specifications. Design conditions shall be Supply air: 2365 cfm at DB 93 deg F/WB 82 deg F during summer & DB 90.5 deg F/82.6 deg F during monsoon and Return/Exhaust air: 2175 cfm at DB 78.0 deg F /RH 57% .
86 86 (iii) Fan section with direct driven Plug fan (minimum 75%) with lowest sound level for the design duty conditions; suitable to work in varying static pressure range (due to 3 stage filtration IPD to FPD). Plug type fan shall be complete with motor, vibration isolators and VFD. Fan shall be suitable to deliver 2365 cfm at total static pressure of 40mm WC. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. The motor & blower assembly shall be mounted on extruded aluminium section only.\n(iv) Discharge plenum comprising of frame mounted 300mm thick bag type fine filters (dry-cleanable type with high pressure blower) of non-woven synthetic media (efficiency 99% down to 3 microns complying to MERV-14). Filter frame shall be made of Aluminium only. It shall also have face & by-pass dampers between the lower & upper tier and at the outlet.The dampers shall be opposed blade manual type low leakage Aluminium aerofoil gear driven VCD. \nNote: The above AHU shall have provision of space for installation of steam type humidifier package & have remote control provision in the OT for temp. & RH adjustment. (The AHU shall be interlocked with digital temp. & RH controller)
87 87 Supply, Installation, Testing and Commissioning of double skin construction, horizontal floor mounted in two tier construction blow-through type chilled water Air handling unit for OT No. 04 of 2291 CFM/10.56 TR capacity fabricated out of extruded aluminium section with 0.8 mm pre-plasticized / pre-coated galvanised steel sheet outside & 0.8 mm polished SS-304 sheet inside each, complete with modules as listed below. The AHU panels shall be minimum 43 mm thick & insulated with 40 (± 2) kg/m³ density compressed glass wool & shall have thermal break profile. Total static pressure shall be checked by vendor. Change in static pressure will not attract any price implication.The AHU shall be complete in all respects along with accessories as per specifications. The capacity of Air-handlers shall be as follows:-\nSUPPLY AIR STREAM (LOWER TIER)\n(i) Fresh Air Intake section with manual type low leakage Aluminium aerofoil gear driven VCD with 50mm thick pre filters (washable type) of non-woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8). Filter frame shall be made of Aluminium only\n(ii) Fan section with direct driven Plug fan (minimum 75%) with lowest sound level for the design duty conditions; suitable to work in varying static pressure range (due to 3 stage filtration IPD to FPD). Plug type fan shall be complete with motor, vibration isolators and VFD. Fan shall be suitable to deliver 2291 CFM at total static pressure of 125 mm WG. Motor shall be atleast IE-3 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. The motor & blower assembly shall be mounted on extruded aluminium section only. 1 Each
88 88 (iii) Heat recovery section with enthalpy type heat reclaim wheel . The wheel shall have minimum 75% both sensible and latent balanced effectiveness and performance shall be AHRI certified. Wheel shall also be certified for 0% fungal and bacterial growth at 95% RH and above.Wheel shall be selected for minimum pressure drop to handle the 2291 cfm and maximum face velocity. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. Design conditions shall be Supply air: 2291 cfm at 93.0 DB deg F/WB 82.0 deg F during summer & DB 90.5 deg F/82.6 deg F during monsoon and Return/Exhaust air: 2106 cfm at DB 78.0 deg F /RH 57% . \n(iv) Cooling coil section having 8 rows deep chilled water coil and 2 rows deep hot water coil for winter heating and monsoon reheat. Cooling coils shall be constructed of copper tube & aluminium fins construction alongwith di- electric union. Coil shall have copper header and supporting frame work / end plates in SS 304 construction, polished SS 304 drain pan made out of 22G sheet duly insulated with 25mm thick nitrile rubber. Sufficient space shall be made available between the 2 nos. coil for cleaning/maintenance and shall be provided with required access doors. Coil size shall be selected for a maximum face velocity of 450 feet/minute and performance shall be AHRI certified.\n(v) 8 rows cooling coil shall be suitable to deliver 10.56 TR capacity with ON coil conditions of DB 93 deg F/ WB 82 deg F with a flow rate of 25.3 USGPM maximum.\n(vi) 2 rows Hot water coil shall be suitable to deliver minimum 12.51 kW capacity with ON coil conditions of DB 50 deg F/ WB 49 deg F during winter conditions. Hot water IN at 45 deg C and flow rate of 9.4 GPM maximum.
89 89 (vii) Humidifier section comprising of steam type humidfier of 6 kW capacity.\n(viii) Discharge plenum comprising of 300mm thick bag type fine filters (dry-cleanable type with high pressure blower) of non-woven synthetic media (efficiency 99% down to 3 microns complying to MERV-14) Filter frame shall be made of Aluminium only. At the outlet of discharge section, fire resistance Neoprene flexible connections shall be provided for connection with duct.\nNote: Hepa filters shall be at terminals along with laminar flow plenum & shall not be included in the AHU cost.\nEXHAUST / RETURN AIR STREAM (UPPER-TIER)\n(i) Return Air Intake section comprising of frame mounted 50mm thick pre filters (washable type) of non woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8) . Filter frame shall be made of Aluminium only. At the inlet of the section, fire resistance Neoprene flexible connections shall be provided for connection with duct.\n(ii) Heat recovery section with enthalpy type heat reclaim wheel. The wheel shall have minimum 75% both sensible and latent balanced effectiveness and performance shall be AHRI certified. Wheel shall also be certified for 0% fungal and bacterial growth at 95% RH and above.Wheel shall be selected for minimum pressure drop to handle the 2291 cfm and maximum face velocity. Motor shall be atleast IE 3 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. DOL starter shall be included as per the specifications. Design conditions shall be Supply air: 2291 cfm at DB 93 deg F/WB 82 deg F during summer & DB 90.5 deg F/82.6 deg F during monsoon and Return/Exhaust air: 2106 cfm at DB 78.0 deg F /RH 57% .
90 90 (iii) Fan section with direct driven Plug fan (minimum 75%) with lowest sound level for the design duty conditions; suitable to work in varying static pressure range (due to 3 stage filtration IPD to FPD). Plug type fan shall be complete with motor, vibration isolators and VFD. Fan shall be suitable to deliver 2291 cfm at total static pressure of 40mm WC. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible. The motor & blower assembly shall be mounted on extruded aluminium section only.\n(iv) Discharge plenum comprising of frame mounted 300mm thick bag type fine filters (dry-cleanable type with high pressure blower) of non-woven synthetic media (efficiency 99% down to 3 microns complying to MERV-14). Filter frame shall be made of Aluminium only. It shall also have face & by-pass dampers between the lower & upper tier and at the outlet.The dampers shall be opposed blade manual type low leakage Aluminium aerofoil gear driven VCD. \nNote: The above AHU shall have provision of space for installation of steam type humidifier package & have remote control provision in the OT for temp. & RH adjustment. (The AHU shall be interlocked with digital temp. & RH controller)
91 91 Supply, Installation, Testing & Commissioning of 7.5kW HVAC dedicated VFDs suitable for the following AHU fan motor capacities (the integration of the VFD with AHU is included in this item) with IP-55 enclosures with Mains disconnect suitable to fit-out in electrical panel (flame-proof), having:-\n(i) Built-in EMC Filters (electromagnetic compatibility filters) for VFDs for restriction of conducted emissions to comply with IEC61800: 3 (unrestricted distribution):2004 Category C 1 for required cable length between motor & VFD.\n(ii) Three-feedback PID (proportional-integrated-derivative) controller having capability to simultaneously accept 2 feedback signals from temperature sensor for process optimization and accordingly regulate the speed of the AHUs.\n(iii) Automatic Energy optimization for maximum energy savings.\n 1 Each
92 92 Supply, Installation, Testing & Commissioning of 3.7 kW HVAC dedicated VFDs suitable for the following AHU fan motor capacities (the integration of the VFD with AHU is included in this item) with IP-55 enclosures with Mains disconnect suitable to fit-out in electrical panel (flame-proof), having:-\n(i) Built-in EMC Filters (electromagnetic compatibility filters) for VFDs for restriction of conducted emissions to comply with IEC61800: 3 (unrestricted distribution):2004 Category C 1 for required cable length between motor & VFD.\n(ii) Three-feedback PID (proportional-integrated-derivative) controller having capability to simultaneously accept 2 feedback signals from temperature sensor for process optimization and accordingly regulate the speed of the AHUs.\n(iii) Automatic Energy optimization for maximum energy savings.\n 5 Each
93 93 Supply, Installation, Testing & Commissioning of 2.2 kW HVAC dedicated VFDs suitable for the following AHU fan motor capacities (the integration of the VFD with AHU is included in this item) with IP-55 enclosures with Mains disconnect suitable to fit-out in electrical panel (flame-proof), having:-\n(i) Built-in EMC Filters (electromagnetic compatibility filters) for VFDs for restriction of conducted emissions to comply with IEC61800: 3 (unrestricted distribution):2004 Category C 1 for required cable length between motor & VFD.\n(ii) Three-feedback PID (proportional-integrated-derivative) controller having capability to simultaneously accept 2 feedback signals from temperature sensor for process optimization and accordingly regulate the speed of the AHUs.\n(iii) Automatic Energy optimization for maximum energy savings.\n 2 Each
94 94 Supply, Installation, Testing and Commissioning of micro-processor based Room temperature + humidity sensor and remote adjuster package within a MS housing on wall having a stainless steel cover plate.This package shall have a temperature and humidity display - red color 2" high LED character for operation rooms.\nSensor adjuster (snap acting humidistat/proportional thermostat, microprocessor-based) and displayer package, as described above; ssuitable for CHW, Monsoon reheat & humidifire connection\n 6 Each
95 95 Supplying, laying/ fixing, testing and commissioning of 125mm dia(32 mm thick insulation) nominal sizes of chilled / hot water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with closed cell Class 'O' Nitrile Rubber Elastomeric Insulation of density 40 - 60 kg/m3, Thermal Conductivity of 0.035 W/mK at 0 deg. Celsius Mean Temp. and µ=7000 (without any additional Vapour Barrier) and factory laminated 7 mil Glass Cloth (GC) covering; to be applied on pipes using manufacturer's recommended rubber-based adhesive in a blend of solvents, complete as per specifications and as required complete in all respects.\nNote: The pipes of sizes 150mm & below shall be M.S. 'C' class as per IS:1239\n 100 RM
96 96 All as per item No. 62 here-in-before but 100mm dia (32mm thick insulation) complete. 20 RM
97 97 All as per item No. 62 here-in-before but 80mm dia (25mm thick insulation) complete. 10 RM
98 98 All as per item No. 62 here-in-before but 65mm dia (25mm thick insulation) complete. 120 RM
99 99 All as per item No. 62 here-in-before but 50mm dia (25mm thick insulation) complete. 50 RM
100 100 All as per item No. 62 here-in-before but 40mm dia (25mm thick insulation) complete. 30 RM
101 101 All as per item No. 62 here-in-before but 32mm dia (25mm thick insulation) complete. 50 RM
102 102 All as per item No. 62 here-in-before but 25mm dia (25mm thick insulation) complete. 30 RM
103 103 Supplying, Fixing, Testing and Commissioning of butterfly valve(mannual) of 100mm dia with C I body SS Disc, Nitrile Rubber seal & O- Ring PN 16 pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 16 Each
104 104 Supplying, Fixing, Testing and Commissioning of butterfly valve(mannual) of 65mm dia with C I body SS Disc, Nitrile Rubber seal & O- Ring PN 16 pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 10 Each
105 105 Supplying, Fixing, Testing and Commissioning of butterfly valve(mannual) of 50mm dia with C I body SS Disc, Nitrile Rubber seal & O- Ring PN 16 pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 14 Each
106 106 Supplying, Fixing, Testing and Commissioning of 40mm dia ball valve set with and without Y-strainer with bronze body, flanged end type for chilled/hot water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 5 Each
107 107 Supplying, Fixing, Testing and Commissioning of 32mm dia ball valve set with and without Y-strainer with bronze body, flanged end type for chilled/hot water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 6 Each
108 108 Supplying, Fixing, Testing and Commissioning of 25mm dia ball valve set with and without Y-strainer with bronze body, flanged end type for chilled/hot water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 2 Each
109 109 Supplying, Fixing, Testing and Commissioning of 40mm dia ball valve set without Y-strainer with bronze body, flanged end type for chilled/hot water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 10 Each
110 110 Supplying, Fixing, Testing and Commissioning of 32mm dia ball valve set without Y-strainer with bronze body, flanged end type for chilled/hot water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 12 Each
111 111 Supplying, Fixing, Testing and Commissioning of 25mm dia ball valve set without Y-strainer with bronze body, flanged end type for chilled/hot water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 4 Each
112 112 Supplying, Fixing, Testing and Commissioning of 100mm dia balancing valve with BUILT-IN MEASURING FACILITY of C I body flanged construction with EPDM coated disc with long pitch with protruded out pipe insulation & PN 16 pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 3 Each
113 113 Supplying, Fixing, Testing and Commissioning of 65mm dia balancing valve with BUILT-IN MEASURING FACILITY of C I body flanged construction with EPDM coated disc with long pitch with protruded out pipe insulation & PN 16 pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 2 Each
114 114 Supplying, Fixing, Testing and Commissioning of 50mm dia balancing valve with BUILT-IN MEASURING FACILITY of C I body flanged construction with EPDM coated disc with long pitch with protruded out pipe insulation & PN 16 pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 3 Each
115 115 Supplying, Fixing, Testing and Commissioning of 40mm dia balancing valve with BUILT-IN MEASURING FACILITY of C I body flanged construction with EPDM coated disc with long pitch with protruded out pipe insulation & PN 16 pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 5 Each
116 116 Supplying, Fixing, Testing and Commissioning of 32mm dia balancing valve with BUILT-IN MEASURING FACILITY of C I body flanged construction with EPDM coated disc with long pitch with protruded out pipe insulation & PN 16 pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 6 Each
117 117 Supplying, Fixing, Testing and Commissioning of 25mm dia balancing valve with BUILT-IN MEASURING FACILITY of C I body flanged construction with EPDM coated disc with long pitch with protruded out pipe insulation & PN 16 pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 2 Each
118 118 Supplying, Fixing, Testing and Commissioning of 100mm dia Non-Return Valve with dual plates of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 3 Each
119 119 Supplying, Fixing, Testing and Commissioning of 65mm dia Non-Return Valve with dual plates of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 1 Each
120 120 Supplying, Fixing, Testing and Commissioning of 50mm dia Non-Return Valve with dual plates of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 1 Each
121 121 Supplying, Fixing, Testing and Commissioning of 100mm dia Y-Strainer of ductile CI Body flanged ends with stainless steel strainer for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 6 Each
122 122 Supplying, Fixing, Testing and Commissioning of 65mm dia Y-Strainer of ductile CI Body flanged ends with stainless steel strainer for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 3 Each
123 123 Supplying, Fixing, Testing and Commissioning of 50mm dia Y-Strainer of ductile CI Body flanged ends with stainless steel strainer for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 4 Each
124 124 Supplying, Fixing, Testing and Commissioning of three way motorized valves of 10-17 USGPM with modulating motor in cooling/heating coil of air handling units duly insulated to the same specifications as the connected piping and adequately supported as required. 4 Each
125 125 Supplying, Fixing, Testing and Commissioning of three way motorized valves of 5-9 USGPM with modulating motor in cooling/heating coil of air handling units duly insulated to the same specifications as the connected piping and adequately supported as required. 2 Each
126 126 Supplying, Fixing, Testing and Commissioning of 100mm dia Flow Switch of brass/polymer construction for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 6 Each
127 127 Supplying, Fixing, Testing and Commissioning of 65mm dia Flow Switch of brass/polymer construction for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 2 Each
128 128 Supplying, Fixing, Testing and Commissioning of 50mm dia Flow Switch of brass/polymer construction for chilled water circulation duly insulated to the same specifications as the connected piping and adequately supported as required. 2 Each
129 129 Supplying, Fixing and Testing of Industrial type pressure gauges with gunmetal / brass construction isolating valve complete with all accessories as required. 46 Each
130 130 Supplying and Fixing of Industrial type mercury in glass industrial type thermometers with gunmetal/ brass construction isolating valve complete with all accessories as required. 26 Each
131 131 Supplying and Fixing of Digital thermometers with probe suitable for binder test point application with brass construction, nitrile sealing bushes, max. operating pressure of 16 bar & max. working temperature of 110 deg celsius as required. 1 Each
132 132 Supplying and Fixing of Dial type pressure gauge with probe suitable for binder test point application with brass construction, nitrile sealing bushes, max. operating pressure of 16 bar & max. working temperature of 110 deg celsius as required. 1 Each
133 133 Supplying and Fixing of Dial type pressure gauge with probe suitable for binder test point application with brass construction, nitrile sealing bushes, max. operating pressure of 16 bar & max. working temperature of 110 deg celsius as required. 1 Each
134 134 Supplying, Fixing and Testing of Auto Air - purge valve of brass construction of 15 mm dia (Air Vent will be fitted with an isolating ball valve - gunmetal/brass construction) 16 Each
135 135 Supply, Installation, Testing and Commissioning of 100 mm dia Flexible Connector . pipe having PN 16 working pressure with anti vacuum rings complete with flanges, nuts, bolts, seal etc. 18 Each
136 136 Supply, Installation, Testing and Commissioning of 65 mm dia Flexible Connector . pipe having PN 16 working pressure with anti vacuum rings complete with flanges, nuts, bolts, seal etc. 6 Each
137 137 Supply, Installation, Testing and Commissioning of 50 mm dia Flexible Connector . pipe having PN 16 working pressure with anti vacuum rings complete with flanges, nuts, bolts, seal etc. 6 Each
138 138 Supplying, Fixing, Testing and Commissioning of 40 mm dia G.I. medium class water pipes as per IS 1239/1979 of following sizes along with necessary clamps, fittings such as bends, tees etc. adequately supported and duly insulated with 13 mm thick closed cell elastomeric nitrile rubber of class 'O' insulation applied by adhesive conforming to standard specifications complete with type 3, grade 1 roofing feltstrip (as per IS:1322 as amended up to date) at joints and repairing of damage to building etc. as required complete in all respects. 30 RM
139 139 Supply, Installation, Testing of open-type expansion tank size of 500 x 500 x 500 (high) of MS Construction made of 6 mm thick mild steel sheet duly insulated with XLPE insulation applied by adhesive conforming to standard specifications and finally applying 0.63 mm thick aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip (as per IS:1322 as amended up to date) at joints and repairing of damage to building etc., as required, complete in all respects with connection over flow and drain 40 mm dia. 3 Each
140 140 Supply & Installation of make up water tank of 500 Ltr capacity of HDPE Construction as required complete in all respect with connection, over flow and drain. Make up connection with float valve, drain valve, incoming line valves and fittings as required. 3 Each
141 141 Supplying, Fixing, Testing and Commissioning of 150 mm dia condenser water pipes and materials along with necessary clamps, vibration-isolators and fittings such as bends, tees etc. but excluding strainer and gauges etc. adequately supported on rigid supports / including painting valves including minor holes & works making of good the damage done welded black steel pipe as IS:3589 walls etc as required. Note:- The pipes of sizes 150mm & below shall be M.S. heavy class as per IS:1239 30 RM
142 142 Supplying, Fixing, Testing and Commissioning of 125 mm dia condenser water pipes and materials along with necessary clamps, vibration-isolators and fittings such as bends, tees etc. but excluding strainer and gauges etc. adequately supported on rigid supports / including painting valves including minor holes & works making of good the damage done welded black steel pipe as IS:3589 walls etc as required. Note:- The pipes of sizes 150mm & below shall be M.S. heavy class as per IS:1239 50 RM
143 143 Supplying, Fixing, Testing and Commissioning of 150 mm dia Butterfly Valve (Mannual) with cast steel body SS Disc, Buna-N integrally moulded Seal & O-Ring. The valve shall be suitable for PN 16 working pressure for condenser water circulation as required. 3 Each
144 144 Supplying, Fixing, Testing and Commissioning of 125 mm dia Butterfly Valve (Mannual) with cast steel body SS Disc, Buna-N integrally moulded Seal & O-Ring. The valve shall be suitable for PN 16 working pressure for condenser water circulation as required. 16 Each
145 145 S&F 125mm dia BALANCING VALVE with BUILT-IN MEASURING FACILITY of Gunmetal construction upto 50 mm dia & cast steel/ ductile iron body upto 300 mm dia as required having flanged construction with SS disc having long pitch with protruded out pipe insulation & suitable for PN 16 working pressure for condenser water circulation as required. The Ductile iron body shall be painted with one coat of Inorganic ethyl self-curing zinc silicate premier at 75 microns & single coat of Super High build epoxy MIO Coating cured with polyamide hardener at 150 microns & finally two coats of High Build Gloss Aliphatic Acrylic Polyurethane at 50 micron dry film thickness. 3 Each
146 146 S&F 125mm dia NON - RETURN VALVE with dual plates of cast steel construction, SS plates, Body lining-BUNA-N, flanged end construction, suitable for PN 16 working pressure for condenser water circulation as required. 3 Each
147 147 S&F 125mm dia Y - STRAINER of cast steel body, flanged ends with stainless steel strainer, suitable for PN 16 working pressure for condenser water circulation as required. 3 Each
148 148 Supply, Installation, Testing and Commissioning of Flexible Connector of 125mm dia for following dia. pipe having PN 16 working pressure with anti-vacuum rings complete with flanges, nuts, bolts, seal etc. to be installed at condenser suction and discharge. 14 Each
149 149 Supply,Installation, Testing and Commissioning FLOW SWITCH of brass/polymer construction suitable for 125 mm dia. Pipe complete with all accessories as required. 3 Each
150 150 Supply,Installation, Testing and Commissioning Industrial type pressure gauges with gun metal/brass construction isolating valve complete with all accessories as required. 12 Each
151 151 Supply,Installation, Testing and Commissioning Industrial type mercury in glass industrial type thermometers with gun metal/ brass construction isolating valve complete with all accessories as required. 6 Each
152 152 Supply,Installation, Testing and Commissioning Auto Air - purge valve of brass construction of 15 mm dia (air vent will be fitted with an isolating ball valve - gunmetal/brass construction ) complete with all accessories as required. 6 Each
153 153 Supply, Installation, Testing and commissioning of On-line, non-chemical water treatment scale preventer system (suitable for 150 mm dia. pipe) having flow rate 500 USGPM complete with all accessories as required. 6 Each Set
154 154 Supply & Installation of make-up water tank of 10000 Ltr capacity of HDPE Construction as required complete in all respects with connection, over flow and drain. Make up connection with float valve, drain valve, incoming line valves and fittings as required. 1 Each
155 155 Supply, Installation, Balancing and Commissioning of factory-fabricated GSS sheet metal rectangular ducting of 24 gauge (thickness 0.63mm) with supports as per IS 655-2010 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and as required 500 Sqm
156 156 Supply, Installation, Balancing and Commissioning of factory-fabricated GSS sheet metal rectangular ducting of 22 gauge (thickness 0.8mm) with supports as per IS 655-2010 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and as required 300 Sqm
157 157 Supply, Fabrication, Installation, Balancing and Commissioning of site- fabricated GSS sheet metal rectangular ducting of 24 gauge (thickness 0.63mm) with supports as per IS 655-2010 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and as required 150 Sqm
158 158 Supply, Fabrication, Installation, Balancing and Commissioning of site- fabricated GSS sheet metal rectangular ducting of 22 gauge (thickness 0.8mm) with supports as per IS 655-2010 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and as required . 100 Sqm
159 159 Supply, Installation, Testing and Commissioning of factory-fabricated Aluminium sheet metal (conforming to IS:737-1955) rectangular ducting of 22 gauge (thickness 0.8mm) as per BIS (IS : 655) standard, silicon sealed complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications . 360 Sqm
160 160 Supply, Installation, Testing and Commissioning of factory-fabricated Aluminium sheet metal (conforming to IS:737-1955) rectangular ducting of 20 gauge (thickness 1.0 mm) as per BIS (IS : 655) standard, silicon sealed complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications. 300 Sqm
161 161 Supply, Installation, Testing and Commissioning of GI volume control damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as required. 7 Sqm
162 162 Supply, Installation, Testing & Balancing of extruded aluminium in aerofoil construction opposed multi-blade volume control dampers complete with bush, gears, linkages, shaft & operating handles within ducts to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air. (FOR OTs) 2 Sqm
163 163 Supply & Fixing of powder coated extruded aluminum Supply air grilles with volume control dampers complete with nuts, bolts, screws etc. as per approved drawings and as required. 5 Sqm
164 164 Supply & Fixing of powder coated extruded aluminum Return air grilles without volume control damper complete with nuts, bolts, screws etc. as per approved drawings and as required. 5 Sqm
165 165 Supply, Installation, Testing and Commissioning of powder coated extruded aluminium louvers with synthetic removable type filter, bird screen & damper for fresh air intake. 1 Sqm
166 166 Supply, Installation, Testing and Commissioning of factory fabricated single skin (duly insulated from inside with 25mm thick anti-microbial closed cell elastomeric insulation) laminar air flow pattern perforated Plenum made of stainless steel grade SS 304 of 1mm sheet (Hairline finish) with SS 304 grade perforated grill below Hepa filters, extruded Aluminium aerofoil section VCD, DOP/DOS tested point-to-point scanned mini pleat Hepa filters having efficiency better than 99.97 % down to 0.3 micron particle size. Hepa filters frame shall be in aluminium/SS construction and flange type. Media shall be micro fibre glass (imported)protected with Aluminium mesh and sealed with epoxy glue. IPD of filters shall be less than 15mm WG and FPD shall be max 50mm. All type of hard wares like nuts/bolts,angles, cleats, supports, etc. shall be of stainless steel construction only, mild steel shall not be allowed for any component. Air entry in the housing shall be from sides and filters shall be accessible from bottom only. Perforated SS grilles shall have minimum 50% free area to have the face velocity as per the NABH requirement. Plenum housing shall have 2nos. pressure measuring ports and central portion having a provision to fix the OT light fixture. The plenum shall be suitable for operation theatre with all accessories as required & to suit site condition of size 2.7m width x 2.7 m depth x 0.45m Height. Third-party OT Validation and particle count test shall be in the scope of the Vendor. 6 Each
167 167 Supplying, Installation, Testing and Commissioning of fire-cum-smoke motorized dampers as required, the blades and frame shall be min. 1.6 mm thick GI sheet and factory fitted in a sleeve made out of 1.6 mm thick GS Sheet of min. 400 mm lemgth, as & where required, of required sizes including control wiring. The damper shall be motorized and have spring-return mechanism so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall have in-built mechanism and not externally mounted. For smoke extraction, necessary control arrangement shall be provided for passive smoke control system in the event of fire signal. The dampers shall be CBRI tested and certified for 90 minute fire rating against flame penetration as per UL standard 555-1995. The assembly shall be complete in all respects, as required.
168 168 Motorized fire cum smoke damper 4 Sqm
169 169 Spring-return motorized assembly 10 Each
170 170 Actuator with control panel 10 Each
171 171 Supply and Application of 15mm thick Acoustic Insulation of supply Air Duct lining with engineered Nitrile Rubber open cell foam with Density 140 - 180 kg/m3 passing Class-1 Fire Performance test as per BS-476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass fungi resistance test as per DIN EN ISO 846 Method A and bacterial resistance test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended rubber-based adhesive in a blend of solvents. 100 Sqm
172 172 Supply and Application of 25 mm thick Acoustic Insulation on walls and ceiling of AHU Room with engineered Nitrile Rubber open cell foam with density 140 - 180 kg/m3 passing Class 1 Fire Performance test as per BS-476 Part 7; Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in anti-microbial protection. The material should pass fungi resistance test as per DIN EN ISO 846 Method A and bacterial resistance test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended rubber-based adhesive in a blend of solvents. 2 metal strips in cross and 5 anchor fasteners (4 at the corners of the metal strip and 1 at the centre) to be fixed per sqmt. sheet of the material. 100 Sqm
173 173 Supply & Installation of 19mm thick Thermal Insulation on ducts not exposed to sunlight using closed cell class 'O' Nitrile Rubber elastomeric insulation of density 40 - 55 jg/m3, Thermal Conductivity of 0.037 W/mK at 20 deg. celcius mean temp. and µ=7000 (without any additional vapour barrier) and with factory laminated aluminium foil of minimum 60 microns thickness having weight of 193 gsm as per EN ISO 2286-2, tensile strength shall be 90N/15mm as per EN ISO 527-3 with elongation > 10% as per EN ISO 527-3; to be applied on Ducts using manufacturer's recommended rubber-based Aahesive in a blend of solvents. 1600 Sqm
174 174 Supply, Installation, Testing and Commissioning of Building & Energy Management System (BMS) \nPC Workstation or equivalent Server machine, INTEL® XEON® Processor E5 series: 3.0 - 3.8 GHz, 4 Cores, 16 GB RAM & 1 TB HDD, 10 MB cache, 1 Gbps Ethernet LAN; OS: Windows10, integrated graphics, USB 3.0 ports & internal modem, PCIe expansion slots, optical drive (DVD + RW), Web server software, 1 Gbps Network Interface card for network connection, Ethernet switch and network rack (if required), in-built anti-virus software.\n\nAccessories:\n1. Monitor: 27" colour graphics monitor, IPS with LED backlight, 1920x1080 FHD resolution, 16:9 aspect ratio with 7 ms response time\n2. Optical Mouse\n3. Keyboard\n4. Printer: Laser-jet colour A4 multi-function system-compatible printer 1 Each
175 175 Supply, Installation, Testing and Commissioning of Multi-user, with minimum 5 simultaneous users, having web-based Server license for Building Automation solution with energy management module for energy efficiency and maintainability, with dynamic graphics. The system architecture must support open industry standards including BACnet, MODBUS, OPC. The system ought to have secure remote access to each data point, and easy network extension through plug-n-play I/O modules. The web-based Server software shall work with standard web-browsers such as Microsoft Internet Explorer, Google Chrome, etc., as well as proprietary web-browsers, with e-mail / SMS option available. The software shall be capable of High Availability Mode and Multiple Screen Approach. The software must meet the requirements in the given I/O summary and technical specifications including configuration, facilitate graphic mapping for all I/O summary points, must display animated graphics including flexible dashboard - (displays information on screen), navigation between pages, real-time pop-up alarms - (the software automatically highlights issues / deviations - based on set rules and data analytics), display of logs including comparisons, trends and correlations. The software must provide reports in customized format, as and when required. The software must possess configurable robust password protection for the Building Management System, with military-grade encryption. The system shall have provision for secure remote monitoring, with access point granted to authorized users, as and when required.\nNote: All required software shall have original license compliant with BMS software. 1 Each
176 176 Supply, Installation, Testing and Commissioning of Programmable and Application specific - 32 bit, UL Listed BACnet (BTL certified) Real-Time controllers with programmable memory, field mounted, configured as per given Data Point summary for Chilled Water Plant and AHU and as per given distributions. The controllers must be multi-protocol supporting open industry standards, including BACnet IP. The controllers ought to be stand-alone Direct Digital Controllers (DDCs) / Automation Servers, with I/O modules. DDCs must have minimum 2 built-in Ethernet ports. DDCs shall have alarming/trending and scheduling feature and must have storage capacity to store graphical pages/data. The networkable BACnet DDCs must be capable of peer-to-peer chain-in communication with lockable MS mounting cabinets, duly powder-coated connector strip, internal wiring and with space to house controller and relays, as per the I/O summary. Each DDC must have minimum 20% spare I/O points. No module with digital output to analog output, analog output to digital output conversion shall be allowed to integrate with the system. Proprietary protocol shall not be accepted. No external I/O module or Multiplexer shall be allowed. The power supply for BMS controllers must be of the same make as of controller (UL listed) using 24 VDC power for power ON, TRIAC o/p. Each controller shall feature a jog-dial and an integrated graphical display (128 x 64) with backlight and response time down to 10 ms. 2 Lot
177 177 Supply, Installation, Testing & commissioning of third party Integrator for communication with third party devices. These Integrators shall be of same make as the DDC controllers. 1 Lot
178 178 Supply, installation, testing and commissioning of necessary input sensor transmitters/transducers comprising the following:
179 179 (i) Air-differential Pressure Switch 24 Each
180 180 (ii) Water-differential Pressure Switch 15 Each
181 181 (iii) Immersion-type Temperature Sensor with Thermowell 4 Each
182 182 (iv) Water-differential Pressure Transmitter 1 Each
183 183 (v) Duct Temperature and Humidity Sensor 8 Each
184 184 (vi) Duct Static Pressure Sensor 8 Each
185 185 (vii) Water Bi-Level Switch 3 Each
186 186 (viii)Water Bi-Level Switch 1 Each
187 187 Supply, installation, testing and commissioning Digital Energy Meters with RS-485 port, LCD display type, suitable for 3P, 4W LT application, for 5A CT secondary and CT primary selected from 5A to 6000A in steps of 5A; the meter shall operate on RS-485 MODBUS RTU communication protocol and record parameters like kWh, V, A, PF, kW and frequency; class accuracy 1.0. all as specified and directed.\n\n 15 Each
188 188 Supplying, laying, termination, testing and commissioning of signal cable \n(2 core x 1 mm2), flexible, PVC sheathed, tinned copper conductor cable unarmoured for DI & DO all as specified and directed. 4500 RM
189 189 Supplying, laying, termination, testing and commissioning of communication cable (2 core x 1 mm2), flexible, shielded, PVC sheathed, tinned copper conductor cable unarmoured for AI & AO all as specified and directed. 1500 RM
190 190 Supplying, laying, termination, testing and commissioning of power cable \n(2 core x 1.5 mm2), flexible, PVC sheathed, XLPE insulated, tinned copper power cable armoured for DDC panels all as specified and directed. 300 RM
191 191 Supplying, laying, termination, testing & commissioning of flexible CAT-6 LAN cable for computer networking with solid annealed bare electrolytic grade copper conductor and overall FR PVC jacketing, colour blue, shielded twisted pair all as specified and directed. 1000 RM
192 192 Supplying and laying of 25mm dia ISI-mark 1.6 mm thick FRPVC conduit on surface/ recess including cutting/filling chases along with conduit, accessories etc. complete as required. 3000 RM
193 193 Supplying and laying of 20 mm dia ISI-mark 1.6 mm thick FRPVC conduit on surface/ recess including cutting/filling chases along with conduit, accessories etc. complete as required. 3000 RM
194 194 Pre-requisites:-\nThe outgoing feeders as indicated in BOQ shall have suitable range of followings (except capacitor feeders). \n(a) ALL Digital electronic MFM cum kWh meter where provided shall be equipped with communication port & three-phase indicating lamps protected by 2 amps SP MCBs. \n(b) 415/110V suitable rating control transformer shall be provided for aux. control supply. \n(c) Wiring with space heater, thermostat and control MCBs shall be provided for all vertical sections of main LT panel. \n(d) All incoming as well as outgoing feeders shall have pad locking facility. \n(e) Suitable danger board shall be provided. \n(f) All MCCBs shall be provided with front rotary handle and operating mechanism for door interlock with pad locking of MCCBs handles in “OFF” position.\n(g) All hinged door shall be earthed through 2.5 sq.mm tinned braided copper wire.\n(h) Panels shall be powder-coated with grey paint shade no. RAL-7032 of IS-5\n(j) Minimum Degree of protection for following type of distribution panel enclosure shall be as per IS:60439\n(k) All motor feeders MCCBs shall be of motor duty.\n(l) Supporting/Base rigid steel framework.\n(m) TPN MCCB’s shall mean 3 pole MCCB’s with adequate sizes of neutral link.\n(n) Final rating & various parameters, in addition to those specified below, shall be selected on the bases of ambient conditions at site, client specific requirements, requirement for the NOC from various statutory authorities, as per detailed design stage calculations.\n(o) Each Panel incomers/outgoings shall be provided with suitable contacts/terminals to receive the Al. conductor cables given in the latter section.\n(p) Each Panel shall be minimum IP-54 for Indoor environment except for outdoor conditions, which are mentioned separately.
195 195 Supply, installation, testing & commissioning of wall-mounted front operated LT PANEL for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design with CRCA sheet steel of 2mm thickness for frame work and covers, 3mm thickness for gland plates i/c cleaning & surface treatment with 9 tank process before powder coating in approved shade, having specified below Amp. capacity extensible type TPN Aluminium Alloy bus bars with suitable rating: neutral to high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35kA for 1 sec, bottom base channel of MS section not less than 100mm x 75mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 32mm x 5mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size with earth bus, Al. bus bars, numbering & sign writing, interconnection & control wiring including the cost of connection through bus bar / copper conductor flexible connection with necessary interlocking as per requirement with PVC insulated FRLS copper conductor single core cable, cable alleys, cable gland plates in two halves, i/c providing following switch gears:\n\n(a) INCOMER\n(i) 1 no. 630A 4P MCCB (35 kA) Icu=Ics micro-processor based having earth fault protection with 600A 4P ASTS(T) with bridging bars and as per IS/IEC-60947 complete as required.\n(b) METERING & INDICATION\n(i) 1 set of R, Y, B phase, ON indicating lamps\n(ii) 1 no. (0-500V) Voltmeter with built-in VSS with 3 nos. 2A SP MCB\n(iii) 1 no. (0-500A) Ammeter with ASS with 3 nos. 500/5A CTs 1 Each
196 196 (c) BUS-BAR\n(i) 1 set of 800A TPN Aluminium Bus-Bar with colour-coded PVC sleeves\n(d) OUTGOINGS-Following Outgoings with thermal magnetic-based releases (except specified anywhere) with Volt Meter & required CTs, indications, operating handle with door interlock, spreader links and phase barrier, solid neutral link and accessories as required. (Ics=Icu=35kA) for each. Note: Chiller is assumed to be provided with its starting arrangement with chiller supply.\n(i) 4 nos. 125A TP MCCB 25 kA (3 Chiller, 1 spare) microprocessor-based having earth fault\n(ii) 4 nos. 16A TP MCB 10 KA (3 Primary CHWP, 1 spare) \n(iii) 4 nos. 16A TP MCB 10 KA (3 Secondary CHWP, 1 spare) \n(iv) 4 nos. 25A TP MCB 10 KA (3 CDWP, 1 spare) \n(v) 3 nos. 16A TP MCB 10 KA (2 CT Fan , 1 spare ) \n(vi) 2 nos. 200A TP MCCB 25 KA (1 HWG for OTs, 1 spare) \n(vii)2 nos. 125A TP MCCB 25 KA (1 HWG for Common area, 1 spare) \n(viii)5 nos. 16A TP MCB 10 KA (4 HWP, 1 spare) \n(ix) 10 nos. 25A TPN/SPN MCB c curve 10 KA\n(e) Automatic DOL starter for 0.75 kW motors with over load relay, SET indications, Push Buttons, auto manual selector switch, C.T. operated Ammeter with selector switch etc. complete with single phase preventer as required - 1 set (HWP for Common area)\n(f) Automatic DOL starter for 1.1 kW motors with over load relay, SET indications, Push Buttons, auto manual selector switch, C.T. operated Ammeter with selector switch etc. complete with single phase preventer as required - 1 set (HWP for OTs)\n
197 197 (g) Automatic DOL starter for 2.2 kW motors with over load relay, SET indications, Push Buttons, auto manual selector switch, C.T. operated Ammeter with selector switch etc. complete with single phase preventer as required - 3 sets (primary CHWP)\n(h) Automatic Star Delta starter for 9.3 kW motors with over load relay, set of indications, Push Buttons, auto manual selector switch, C.T. operated Ammeter with selector switch etc. complete with single phase preventer as required - 3 Sets (CDWP)\n(j) Automatic DOL starter for 5.5 kW motors with over load relay, SET indications, Push Buttons, auto manual selector switch, C.T. operated Ammeter with selector switch etc. complete with single phase preventer as required - 2 sets (Cooling Tower)
198 198 Supply, installation, testing & commissioning of wall-mounted front operated LT PANEL for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design with CRCA sheet steel of 2mm thickness for frame work and covers, 3mm thickness for gland plates i/c cleaning & surface treatment with 9 tank process before powder coating in approved shade, having specified below Amp. capacity extensible type TPN Aluminium Alloy bus bars with suitable rating: neutral to high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35kA for 1 sec, bottom base channel of MS section not less than 100mm x 75mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 32mm x 5mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size with earth bus, Al. bus bars, numbering & sign writing, interconnection & control wiring including the cost of connection through bus bar / copper conductor flexible connection with necessary interlocking as per requirement with PVC insulated FRLS copper conductor single core cable, cable alleys, cable gland plates in two halves, i/c providing following switch gears:\n(a) INCOMER\n(i) 1 no. 40A 4P MCCB isolator (25 kA) Icu=Ics with front operating rotary handle and as per IS/IEC-60947 complete as required.\n(b) METERING & INDICATION\n(i) 1 set of R, Y, B phase, ON indicating lamps\n(ii) 1 no. (0-500V) Voltmeter with built-in VSS with 3 nos. 2A SP MCB\n(iii) 1 no. (0-60A) Ammeter with ASS with 3 nos. 60/5A CTs\n 1 Set
199 199 (a) INCOMER\n(c) BUS-BAR\n(i) 1 set of 63A TPN Aluminium Bus-Bar with colour-coded PVC sleeves\n(d) OUTGOINGS- Following Outgoings with thermal magnetic-based releases with Volt Meter & required CTs, indications, operating handle with door interlock, spreader links and phase barrier, solid neutral link and accessories as required. \n(Ics=Icu=16kA) for each.\n(i) 2 nos. 25A TP MCB (1 AHU, 1 Spare)\n(ii) 2 nos. 25A TP MCB c curve 10 KA (1 Humidifier, 1 Spare)\n(iii) 5 nos. 16A SPN MCB c curve 10 KA\n(iv) Panel should have space to fix VFD in AHU, indicating lamp & all safety precautions in a GI enclosure with necessary power and control cable as required
200 200 Supply, installation, testing & commissioning of wall-mounted front operated LT PANEL for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design with CRCA sheet steel of 2mm thickness for frame work and covers, 3mm thickness for gland plates i/c cleaning & surface treatment with 9 tank process before powder coating in approved shade, having specified below Amp. capacity extensible type TPN Aluminium Alloy bus bars with suitable rating: neutral to high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35kA for 1 sec, bottom base channel of MS section not less than 100mm x 75mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 32mm x 5mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size with earth bus, Al. bus bars, numbering & sign writing, interconnection & control wiring including the cost of connection through bus bar / copper conductor flexible connection with necessary interlocking as per requirement with PVC insulated FRLS copper conductor single core cable, cable alleys, cable gland plates in two halves, i/c providing following switch gears:\n(a) INCOMER\n(i) 1 no. 40A 4P MCCB isolator (25 kA) Icu=Ics with front operating rotary handle and as per IS/IEC-60947 complete as required.\n(b) METERING & INDICATION\n(i) 1 set of R, Y, B phase, ON indicating lamps\n(ii) 1 no. (0-500V) Voltmeter with built-in VSS with 3 nos. 2A SP MCB\n(iii) 1 no. (0-60A) Ammeter with ASS with 3 nos. 60/5A CTs\n(c) BUS-BAR\n(i) 1 set of 63A TPN Aluminium bus-bar with colour-coded PVC sleeves\n(d) OUTGOINGS- Following Outgoings with thermal magnetic-based releases with Volt Meter & required CTs, indications, operating handle with door interlock, spreader links and phase barrier, solid neutral link and accessories as required. \n(Ics=Icu=16kA) for each. 1 Set
201 201 (i) 2 nos. 16A TP MCB (1 AHU, 1 Spare)\n(ii) 2 nos. 16A TP MCB c curve 10 KA (1 Humidifier, 1 Spare)\n(iii) 5 nos. 16A SPN MCB c curve 10 KA\n(iv) Panel should have space to fix VFD in AHU, indicating lamp & all safety precautions in a GI enclosure with necessary power and control cable as required.
202 202 Supply, installation, testing & commissioning of wall-mounted front operated LT PANEL for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design with CRCA sheet steel of 2mm thickness for frame work and covers, 3mm thickness for gland plates i/c cleaning & surface treatment with 9 tank process before powder coating in approved shade, having specified below Amp. capacity extensible type TPN Aluminium Alloy bus bars with suitable rating: neutral to high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35kA for 1 sec, bottom base channel of MS section not less than 100mm x 75mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 32mm x 5mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size with earth bus, Al. bus bars, numbering & sign writing, interconnection & control wiring including the cost of connection through bus bar / copper conductor flexible connection with necessary interlocking as per requirement with PVC insulated FRLS copper conductor single core cable, cable alleys, cable gland plates in two halves, i/c providing following switch gears:\n(a) INCOMER\n(i) 1 no. 40A 4P MCCB isolator (25 kA) Icu=Ics with front operating rotary handle and as per IS/IEC-60947 complete as required.\n(b) METERING & INDICATION\n(i) 1 set of R, Y, B phase, ON indicating lamps\n(ii) 1 no. (0-500V) Voltmeter with built-in VSS with 3 nos. 2A SP MCB\n(iii) 1 no. (0-60A) Ammeter with ASS with 3 nos. 60/5A CTs\n(c) BUS-BAR\n(i) 1 set of 63A TPN Aluminium bus-bar with colour-coded PVC sleeves\n(d) OUTGOINGS- Following Outgoings with thermal magnetic-based releases with Volt Meter & required CTs, indications, operating handle with door interlock, spreader links and phase barrier, solid neutral link and accessories as required. \n(Ics=Icu=16kA) for each. 2 Set
203 203 (i) 2 nos. 16A TP MCB (1 AHU, 1 Spare)\n(ii) 2 nos. 25A TP MCB c curve 10 KA (1 Humidifier, 1 Spare)\n(iii) 5 nos. 16A SPN MCB c curve 10 KA\n(iv) Panel should have space to fix VFD in AHU, indicating lamp & all safety precautions in a GI enclosure with necessary power and control cable as required.
204 204 Supply, installation, testing & commissioning of wall-mounted front operated LT PANEL for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design with CRCA sheet steel of 2mm thickness for frame work and covers, 3mm thickness for gland plates i/c cleaning & surface treatment with 9 tank process before powder coating in approved shade, having specified below Amp. capacity extensible type TPN Aluminium Alloy bus bars with suitable rating: neutral to high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35kA for 1 sec, bottom base channel of MS section not less than 100mm x 75mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 32mm x 5mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size with earth bus, Al. bus bars, numbering & sign writing, interconnection & control wiring including the cost of connection through bus bar / copper conductor flexible connection with necessary interlocking as per requirement with PVC insulated FRLS copper conductor single core cable, cable alleys, cable gland plates in two halves, i/c providing following switch gears:\n(a) INCOMER\n(i) 1 no. 40A 4P MCCB isolator (25 kA) Icu=Ics with front operating rotary handle and as per IS/IEC-60947 complete as required.\n(b) METERING & INDICATION\n(i) 1 set of R, Y, B phase, ON indicating lamps\n(ii) 1 no. (0-500V) Voltmeter with built-in VSS with 3 nos. 2A SP MCB\n(iii) 1 no. (0-60A) Ammeter with ASS with 3 nos. 60/5A CTs\n(c) BUS-BAR\n(i) 1 set of 63A TPN Aluminium bus-bar with colour-coded PVC sleeves\n(d) OUTGOINGS- Following Outgoings with thermal magnetic-based releases with Volt Meter & required CTs, indications, operating handle with door interlock, spreader links and phase barrier, solid neutral link and accessories as required. \n(Ics=Icu=16kA) for each. 3 Set
205 205 (i) 2 nos. 16A TP MCB (1 AHU, 1 Spare)\n(ii) 2 nos. 25A TP MCB c curve 10 KA (1 Humidifier, 1 Spare)\n(iii) 5 nos. 16A SPN MCB c curve 10 KA\n(iv) Panel should have space to fix VFD in AHU, indicating lamp & all safety precautions in a GI enclosure with necessary power and control cable as required.
206 206 Supply, installation, testing & commissioning of wall-mounted front operated LT PANEL for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design with CRCA sheet steel of 2mm thickness for frame work and covers, 3mm thickness for gland plates i/c cleaning & surface treatment with 9 tank process before powder coating in approved shade, having specified below Amp. capacity extensible type TPN Aluminium Alloy bus bars with suitable rating: neutral to high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35kA for 1 sec, bottom base channel of MS section not less than 100mm x 75mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 32mm x 5mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size with earth bus, Al. bus bars, numbering & sign writing, interconnection & control wiring including the cost of connection through bus bar / copper conductor flexible connection with necessary interlocking as per requirement with PVC insulated FRLS copper conductor single core cable, cable alleys, cable gland plates in two halves, i/c providing following switch gears:\n(a) INCOMER\n(i) 1 no. 25A 4P MCCB isolator (25 kA) Icu=Ics with front operating rotary handle and as per IS/IEC-60947 complete as required.\n(b) METERING & INDICATION\n(i) 1 set of R, Y, B phase, ON indicating lamps\n(ii) 1 no. (0-500V) Voltmeter with built-in VSS with 3 nos. 2A SP MCB\n(iii) 1 no. (0-60A) Ammeter with ASS with 3 nos. 60/5A CTs\n(c) BUS-BAR\n(i) 1 set of 40A TPN Aluminium bus-bar with colour-coded PVC sleeves\n(d) OUTGOINGS- Following Outgoings with thermal magnetic-based releases with Volt Meter & required CTs, indications, operating handle with door interlock, spreader links and phase barrier, solid neutral link and accessories as required. \n(Ics=Icu=16kA) for each. 1 Set
207 207 (i) 2 nos. 16A TP MCB (1 AHU, 1 Spare)\n(ii) 2 nos. 16A TP MCB c curve 10 KA (1 Humidifier, 1 Spare)\n(iii) 5 nos. 16A SPN MCB c curve 10 KA\n(iv) Panel should have space to fix VFD in AHU, indicating lamp & all safety precautions in a GI enclosure with necessary power and control cable as required.
208 208 Supply, laying testing and commissioning of 3.5 core x 70 sq.mm. sizes of XLPE insulated, PVC sheathed, round wire armoured copper conductor cable of 1.1 KV grade on cable tray / surface including clamps, ties etc. as required. 20 RM
209 209 Supply, laying testing and commissioning of 3.5 core x 35 sq.mm. . sizes of XLPE insulated, PVC sheathed, round wire armoured copper conductor cable of 1.1 KV grade on cable tray / surface including clamps, ties etc. as required. 50 RM
210 210 Supply, laying testing and commissioning of 3.5 core x 6 sq.mm. sizes of XLPE insulated, PVC sheathed, round wire armoured copper conductor cable of 1.1 KV grade on cable tray / surface including clamps, ties etc. as required. 100 RM
211 211 Supply, laying testing and commissioning of 3.5 core x 6 sq.mm. sizes of XLPE insulated, PVC sheathed, round wire armoured copper conductor cable of 1.1 KV grade on cable tray / surface including clamps, ties etc. as required. 50 RM
212 212 Supplying and making end terminations with brass compression gland and copper lugs for 3.5 core x 70 sq.mm. sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 1 Set
213 213 Supplying and making end terminations with brass compression gland and copper lugs for 3.5 core x 35 sq.mm. sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 Set
214 214 Supplying and making end terminations with brass compression gland and copper lugs for 3.5 core x 6 sq.mm. sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 8 Set
215 215 Supplying and making end terminations with brass compression gland and copper lugs for 3.5 core x 4 sq.mm. sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 Set
216 216 Providing & fixing of control wiring/power cabling with 2Cx1.5 Sq.mm size of copper conductor armoured cable, making connections etc., as required 150 RM
217 217 Supplying, fabricating and installing of 150mm (50mmx1.6mm thick) size of hot dip galvanized ladder-type cable trays including horizontal vertical bends, reducers, tees, cross members and other accessories as required and duly installed from the ceiling/ side walls with suitable sizes of channels/ angles with anti-corrosion painting, full threaded GI rods etc. complete as required & approved by the Engineer-in-charge 50 RM
218 218 Supplying, fabricating and installing of 200mm (50mmx2.0mm thick) size of hot dip galvanized ladder-type cable trays including horizontal vertical bends, reducers, tees, cross members and other accessories as required and duly installed from the ceiling/ side walls with suitable sizes of channels/ angles with anti-corrosion painting, full threaded GI rods etc. complete as required & approved by the Engineer-in-charge 20 RM
219 219 Materials and labour for earthing complete with galvanised iron earth plate Electrode 600mmx600mmx6.3 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5m below ground level connected with galvanised earth wire of size 4 mmdia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 15mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh charcoal or coke and common salt in alternate layer of 15 cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC 1:3:6 type C-1(With 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation returning filling and removal of surplus earth upto a distance not exceedings 50m etc all as shown on electrical plate No 3 of MES schedule Part-I(2009) including complete all as specified and as directed. 28 Each Set
220 220 Materials and labour for earthing complete with galvanised iron earth plate Electrode 600mmx600mmx6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5m below ground level connected with galvanised strip of size 32mm x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh charcoal or coke and common salt in alternate layer of 15 cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC 1:3:6 type C-1(With 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation returning filling and removal of surplus earth upto a distance not exceedings 50m etc all as shown on electrical plate No 3 of MES schedule Part-I(2009) including complete all as specified and as directed. 18 Each Set
221 221 Manning & operation of chilled water central AC plant 125 TR capacity having 3x62.5 TR Chiller unit (2 working + 1 stand by) & connected equpment installed at OT/ICU complex round the clock in three shifts of 0800 Hrs in all working day including Sunday & holiday. 1002 Shifts
222 222 Ditto all per Srl No item No 221 here-in-before but for next 11 calendar months after completion of 1st 11 calender months. 1002 Shifts
223 223 Ditto all per Srl No item No 221 here-in-before but for next 11 calendar months after completion of 2nd 11 calender months. 1002 Shifts
224 224 Ditto all per Srl No item No 221 here-in-before but for next 03 calendar months after completion of 2nd 11 calender months. 276 Shifts
225 225 Comprehansive maintenance of water cooled scroll chiller central AC plant comprisiging of followings:-\n(a) Water-cooled scroll chiller with multi compressors, comprising of Hermetic compressors, DX Evaporator, shell & tube condenser, suitable expansion device, suitable for operation on \nR-407C refrigerant and complete in all respects as required of 62.5 TR actual Cooling Capacity-3 Nos ( 2 working + 1 standby )\nWater Temperature IN - 54.0 deg F\nWater Temperature OUT - 44.0 deg F\nFouling Factor - 0.0005 FPS\nCondenser :\nWater Temperature IN - 90.0 deg F\nWater Temperature OUT - 97.5 deg F\nFouling Factor - 0.001 FPS\nWater flow rate through Chiller - 150 USGPM\nWater flow rate through Condenser - 250 USGPM \n(b) Split-casing end-suction type Chilled water primary pump set capable of delivering 150 USGPM of water against 12 mtr head comprising of the flowing and complete as required split-coupled type single-stage Pump with bronze impeller, S.S Shaft, CI body and mechanical seal suitable HP, TEFC squirrel cage motor (IE-2) with class 'F' insulation, 2900/1450 RPM synchronous speed, operating at 415 ± 10 % Volts, 3 phase, 50 Hz A.C. supply; duly insulated with 32 mm thick closed cell elastomeric nitrile rubber insulation cladded with aluminium sheets of 0.63mm thickness and properly clamped to pump in two semi-circular sections -3 Nos (2working+1 standby)\n\n\n 1002 Shifts
226 226 Item No 224 Contd./-\n(c) Split-casing end suction Secondary Chilled water pumping system capable of delivering 150 USGPM of water against 20 mtr head , with VFD and all pump system controller, comprising of Vertical Inline split coupled type single stage pumping set with cast iron casing, bronze impellers with stainless steel shaft, connected to suitable capacity TEFC ventilated induction motor (IE-2) with class' F' insulation of 3 phase, 2900/1450 RPM, suitable for 415 volts +10%, 3 phase, 50 Hz A.C. supply, duly insulated with 32 mm thick closed cell elastometric nitrile rubber insulation cladded with aluminium sheets of 0.63 mm thickness and properly clamped to pump in two semicircular sections as required,Variable secondary Panel having dedicated Programmable Logic Controller, with individual drive for each pump and with required nos. of sensors. The Programmable Logic Controller shall be able to control minimum 1 Pump and maximum of 3 to 4 Pumps, These pump are automatic cascade control , automatic sequence change type,with graphical with minimum 320 pixels X 240 Pixels VGA display with backlight type. Drive have rated input frequency 50 Hz and output frequency range of 0.5 to 132 Hz.with an IP55 Nema Standard powder coated steel enclosure with sufficient capacity of cooling fan housed with electrical control components,Electrical Control Panel capable of cyclic operation of pumps - Pump working sequence should change after every operation. Control panel with programmable logic controller (PLC) with inbuilt PID controller, digital display with fluorescent screen with two lines of min. 20 character each and equipped with function keys and service keys. 3 ph, 415 (±10%)V, AC variable speed drive for each pump of suitable capacity rating having standard function of BI loop, controlled stop on loss of supply power loss side through, DDC injection breaking fast stop. Drive should have rated input frequency 50 Hz and output frequency range of 0.5 to 132 Hz,Microprocessor-based Control Panel hava a suitable hardware & software so that it can be integrated directly to iBMS with standard communication open protocol using BACnet / MODBUS as well as open IP.--3 Nos (2 working+1 standby)
227 227 Item No 224 Contd./-\n(d) End suction centrifugal Condenser water pump set capable of delivering 250 USGPM of water against 18 mtr WG head comprising of bronze impeller, S.S Shaft, CI body and mechanical seal , TEFC squirrel cage induction motor (IE-2) with class 'F' insulation, 2900/1450 RPM synchronous speed, operating on 415 ± 10 % Volts, 3 phase, 50 Hz A.C. supply; Minimum Efficiency 75% --3 Nos (2 working+1 standby)\n(e) Mono block pump for hot water capable of delivering of water 56.74 USGPM against 16 meter head, each comprising with bronze impeller and mechanical seal.1 No, TEFC squirrel cage induction motor(IE-2) with class ' F' insulation, 3000 RPM synchronous speed, operating on 415 Volts + 10 % , 3 phase, 50 Hz A.C. supply --2 Nos (1 working+1 standby) \n(f) Mono block pump for hot water capable of delivering of water 34 USGPM against 16 meter head, each comprising with bronze impeller and mechanical seal.1 No, TEFC squirrel cage induction motor(IE-2) with class ' F' insulation, 3000 RPM synchronous speed, operating on 415 Volts + 10 % , 3 phase, 50 Hz A.C. supply --2 Nos (1 working+1 standby) \n(g) Electrically operated Hot Water Generator of actual capacity 75 KW having water inlet temp 45°C & outlet tem 50°C with water flow rate 56.74 USGPM with heaters arranged in banks and Controller and Thermostat so that required qty. of hot water is generated at 50°C with nominal variation, having 100mm thick resin-bonded fiber glass insulation of 24 kg / cum. density finished with 1.25mm thick aluminium sheet cladding including necessary Electrical panel with automatic controls including inlet and outlet connections for water complete with pressure release valve,low level cut-out, Autovent sight-glass-1 No.\n(Degree of protection IP-52 with IS 2147)\n
228 228 Item No 224 Contd/-\n(h) Electrically operated Hot Water Generator of actual capacity 54 KW having water inlet temp 45°C & outlet tem 50°C with water flow rate 34 USGPM with heaters arranged in banks and Controller and Thermostat so that required qty. of hot water is generated at 50°C with nominal variation, having 100mm thick resin-bonded fiber glass insulation of 24 kg / cum. density finished with 1.25mm thick aluminium sheet cladding including necessary Electrical panel with automatic controls including inlet and outlet connections for water complete with pressure release valve, low level cut-out, Autovent sight-glass-1 No.\n(j) Induced draft counter flow, vertical discharge-type FRPCooling tower of 2.36 lakhs kCal/hr heat rejection capacity having water floe rate 250 USGPM with ultra-violet treated durable & highly efficient PVC fillings with integral louvers and drift eliminators, open pan suitable for water distribution complete with hot FRP water basin. The hot water shall be distributed to fills in each cell via open-type gravity basin or with spray nozzles or having self-rotating sprinklers & statically and dynamically balanced two nos. anti-corrosion treated axial flow type fan driven through special bevelled reduction gear box with TEFC induction motor with IP-65 protection, IE-2, suction screen, make up and quick fill arrangement, overflow and drain connections, hot-dipped galvanized ladder, anti vibration mountings etc- 2 Nos.\n(k)Steam-Type Humidifier package with suitable humidistat ( humidifier have interlocking with thermostat of RH sensor) suitable for outdoor installation of capacity 12 KW-2 No, 9KW- 1 No, 6 KW-5 Nos
229 229 Item No 224 Contd/-\n(l) Air Handling Unit factory built Floor-standing double-skin type,made of 25 mm thick panels consisting of pre-plasticized G.I. casing of thickness 0.6 mm at outside layer and 0.6 mm thick plain Al. sheet at inside layer with polyurethane foam (PUF) insulation of density 40(+2) kg/m3 factory injected between them by injection moulding machine, complete with blower section with Direct Driven plug fan of 65mm WG static pressure and 4/6 rows deep cooling coil & 2 rows deep heating coil with aluminium finned copper tubes, filter sections with 50 mm thick washable synthetic type Pre-filters having efficiency 90% down to 10 micron, Fine filters having efficiency 99% down to 5 micron, direct-driven package with TEFC drive motor (IE-2) suitable for VFD application at 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, complete with drain connections with drain valve, stainless steel drain pan, necessary vibration isolation arrangement (spring-loaded), silicon-coated flexible duct connector including ducting network etc. of capacities:\n 9700 CFM -1 No (General area F/F)\n5500 CFM -1 NO (General area G/F)\n\n
230 230 Item No 224 Contd/--\n(m)Air Handling Unit with 100 % fress air having double skin construction, horizontal floor mounted in two tier construction blow-through, fabricated out of extruded aluminium section with 0.8 mm pre-plasticized / pre-coated galvanised steel sheet outside & 0.8 mm polished SS-304 sheet inside each, 43 mm thick & insulated with 40 (± 2) kg/m³ density compressed glass wool & having thermal break profile, manual type low leakage Aluminium aerofoil gear driven VCD with 50mm thick pre filters (washable type) of non-woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8). Filter frame for frash air intake,Heat recovery section with enthalpy type heat reclaim wheel, driven motor is of IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply and VFD compatible, Cooling coil section having 8 rows deep chilled water coil and 2 rows deep hot water coil for winter heating and monsoon reheat. Cooling coils constructed of copper tube & aluminium fins construction alongwith di- electric union. Coil have copper header and supporting frame work / end plates in SS 304 construction, polished SS 304 drain pan made out of 22G sheet duly insulated with 25mm thick nitrile rubber.Discharge plenum comprising of 300mm thick bag type fine filters (dry-cleanable type with high pressure blower) of non-woven synthetic media (efficiency 99% down to 3 microns complying to MERV-14) Hapa filters, fire resistance Neoprene flexible connections for connection of duct & plenum. \nReturn Air Intake section comprising of frame mounted 50mm thick pre filters (washable type) of non-woven synthetic media (efficiency 90% down to 10 microns complying to MERV-8) , fire resistance Neoprene flexible connections for connecting with duct,including ducting network, Heat recovery section with enthalpy type heat reclaim wheel 75% both sensible and latent balanced effectiveness . Capacities of AHU with location are 1422 CFM & 7.15 TR (Burn OT -1)\n1395 CFM & 7.12 TR (Burn OT -2)\n2297 CFM & 10.22 TR (OT - 1)\n2143 CFM & 11.52 TR (OT - 2)\n2365 CFM & 11.22 TR (OT - 3)\n2291 CFM & 10.56 TR (OT - 4)
231 231 Item No 224 Contd/-\n(m) Variable Frequency Devices suitable for the following AHU fan motor capacities ( VFD integrated with AHU ) with IP-55 enclosures with Mains disconnect suitable to fit-out in electrical panel (flame-proof), having Built-in EMC Filters (electromagnetic compatibility filters) for VFDs for restriction of conducted emissions to comply with IEC61800: 3 (unrestricted distribution):2004 Category C 1 for required cable length between motor & VFD.Three-feedback PID (proportional-integrated-derivative) controller having capability to simultaneously accept 2 feedback signals from temperature sensor for process optimization and accordingly regulate the speed of the AHUs for maximum energy savings for following capacities\n7.5 KW - 1 Set\n3.7 KW - 5 Set\n2.2 KW - 2 Set\n(n) Micro-processor based Room temperature + humidity sensor and remote adjuster package within a MS housing on wall having a stainless steel cover plate having temperature and humidity display - red color 2" high LED character for operation rooms.Sensor adjuster (snap acting humidistat/proportional thermostat, microprocessor-based) and displayer package, as described above suitable for CHW, Monsoon reheat & humidifire connection - 6 Set\n(o) chilled / hot water piping of 125mm,100mm,80mm,65mm,50mm ? inside the building (with necessary clamps, vibration isolators and fittings but including valves, strainers, gauges etc.) duly insulated with closed cell Class 'O' Nitrile Rubber Elastomeric Insulation of density 40 - 60 kg/m3, Thermal Conductivity of 0.035 W/mK at 0 deg. Celsius Mean Temp. and µ=7000 (without any additional Vapour Barrier) and factory laminated 7 mil Glass Cloth (GC) covering applied on pipes using rubber-based adhesive in a blend of solvents etc including butterfly valve,ball valve,balancing valve,NRV,Y type strainer,3 way motorised valve, flow switch (100mm to 25mm ),thermometer,pressor guage,auto purge valve,flexible connecter,expansino tank 500x500x500mm,,makeup water tank 500 Ltr,drain pipe 40mm -1 Lot
232 232 Item No 224 contd./-\n(p) Condenser water pipes of 150mm,125mm ? sizes along with necessary clamps, vibration-isolators and fittings such as bends, tees etc. but including strainer and gauges etc. adequately supported on rigid supports / including painting valves including minor holes & works making of good the damage done welded black steel pipe as IS:3589 walls etc as required including butterfly valve,ball valve,balancing valve,NRV,Y type strainer,auto purge valve,flow switch (150mm to 125mm ),thermometer,pressor guage,flexible connecter etc. -1 Lot\n (q) On-line, non-chemical water treatment scale preventer system (suitable for 150 mm dia. pipe) having flow rate 500 USGPM - 1 No\n( r ) HDPE Make-up water tank of capacity 10000 ltr including over flow, drain, make up connection & float valve, drain valve, incoming line valves and fittings etc - 1 No.\n
233 233 Item No 224 contd/-\n(s) BMS COMPUTER WORKSTATION/SERVER SOFTWARE comprising of PC Server machine, INTEL® XEON® Processor E5 series: 3.0 - 3.8 GHz, 4 Cores, 16 GB RAM & 1 TB HDD, 10 MB cache, 1 Gbps Ethernet LAN; OS: Windows10, integrated graphics, USB 3.0 ports & internal modem, PCIe expansion slots, optical drive (DVD + RW), Web server software, 1 Gbps Network Interface card for network connection, Ethernet switch and network rack , in-built anti-virus software.\nAccessories:\n1. Monitor: 27" colour graphics monitor, IPS with LED backlight, 1920x1080 FHD resolution, 16:9 aspect ratio with 7 ms response time\n2. Optical Mouse\n3. Keyboard\n4. Printer: Laser-jet colour A4 multi-function system-compatible printer\nMulti-user, having web-based Server Building Automation solution with energy management module for energy efficiency and maintainability, with dynamic graphics. The system architecture have open industry standards including BACnet, MODBUS, OPC. The system ought to have secure remote access to each data point, and easy network extension through plug-n-play I/O modules.Software works with standard web-browsers such as Microsoft Internet Explorer, Google Chrome, etc., as well as proprietary web-browsers, with e-mail / SMS option available and capable of High Availability Mode and Multiple Screen Approach (displays information on screen), navigation between pages, real-time pop-up alarms - (the software automatically highlights issues / deviations - based on set rules and data analytics), display of logs including comparisons, trends and correlations,provide reports in customized format, as and when required, possess configurable robust password protection for the Building Management System, with military-grade encryption.
234 234 Item No 224 Contd/-\n(t) DDCs Programmable and Application specific - 32 bit, UL Listed BACnet (BTL certified) Real-Time controllers with programmable memory, field mounted, configured as per given Data Point summary for respective building services, and as per given distributions. The controllers have multi-protocol supporting open industry standards, including BACnet IP & can stand-alone Direct Digital Controllers (DDCs) / Automation Servers, with I/O modules. DDCs for chilled water plant & AHUs having built-in Ethernet ports & have alarming/trending and scheduling feature with storage capacity to store graphical pages/data. The networkable BACnet DDCs is capable of peer-to-peer chain-in communication with lockable MS mounting cabinets, duly powder-coated connector strip, internal wiring and with space to house controller and relays. Each DDC have 20% spare I/O points. Each controller have jog-dial and an integrated graphical display (128 x 64) with backlight and response time down to 10 ms.-1 lot\n(u)Input sensor transmitters/transducers comprising the following:\nAir-differential Pressure Switch -24 No\nWater-differential Pressure Switch -15 No\nImmersion-type Temperature Sensor with Thermowell-4 No\nWater-differential Pressure Transmitter-1 No\nDuct Temperature and Humidity Sensor-8 No\nDuct Static Pressure Sensor-8 No\nWater Bi-Level Switch-3 No\nOutside Temperature + Humidity Sensor-1 No\nDigital Energy Meters with RS-485 port, LCD display type, suitable for 3P, 4W LT application, for 5A CT secondary and CT primary selected from 5A to 6000A in steps of 5A; the meter shall operate on RS-485 MODBUS RTU communication protocol and record parameters like kWh, V, A, PF, kW and frequency; class accuracy 1.0-15 No
235 235 Item No 224 Contd/-\n(v) WIRING & CABLING for BMS COMPUTER WORKSTATION \nSignal cable (2 core x 1 mm2), flexible, PVC sheathed, tinned copper conductor cable unarmoured for DI & DO ,AI & AO-1 lot\nPower cable (2 core x 1.5 mm2), flexible, PVC sheathed, XLPE insulated, tinned copper power cable armoured for DDC panels- 1 lot\nFlexible CAT-6 LAN cable for computer networking with solid annealed bare electrolytic grade copper conductor and overall FR PVC jacketing, colour blue, shielded twisted pair- 1 lot\n(w) Wall-mounted front operated LT panel(AC plant Room) for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design with CRCA sheet steel of 2mm thickness for frame work and covers, 3mm thickness for gland plates i/c cleaning & surface treatment with 9 tank process before powder coating in approved shade, having specified below Amp. capacity extensible type TPN Aluminium Alloy bus bars 800 Amp rating: neutral to high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35kA for 1 sec and also including UG XLPE power copper cable of size 70 Sqmm to 4 Sqmm 3.5 core feeding various equpment in plant room & various AHUs.\nIncoming-1 no. 630A 4P MCCB (35 kA) Icu=Ics micro-processor based having earth fault protection with 600A 4P ASTS(T) with bridging bars and as per IS/IEC-60947.\nOutgoing-Following Outgoings with thermal magnetic-based releases (except specified anywhere) with Volt Meter & required CTs, indications, operating handle with door interlock, spreader links and phase barrier, solid neutral link and accessories as required. (Ics=Icu=35kA) for each.\n4 nos. 125A TP MCCB 25 kA (3 Chiller, 1 spare) microprocessor-based having earth fault\n4 nos. 16A TP MCB 10 KA (3 Primary CHWP, 1 spare) \n4 nos. 16A TP MCB 10 KA (3 Secondary CHWP, 1 spare) \n4 nos. 25A TP MCB 10 KA (3 CDWP, 1 spare) \n3 nos. 16A TP MCB 10 KA (2 CT Fan , 1 spare ) \n2 nos. 200A TP MCCB 25 KA (1 HWG for OTs, 1 spare) \n2 nos. 125A TP MCCB 25 KA (1 HWG for Common area, 1 spare) \n5 nos. 16A TP MCB 10 KA (4 HWP, 1 spare) \n10 nos. 25A TPN/SPN MCB c curve 10 KA\n\n\n
236 236 Item N0 224 Contd/-\n(x) Wall-mounted front operated LT Panel (GF Other area AHU) for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design with CRCA sheet steel of 2mm thickness for frame work and covers, 3mm thickness for gland plates & 63 Amp rated Aluminium bus bar and suitable VFD fitted.\nIncoming-1 no. 40A 4P MCCB isolator (25 kA) Icu=Ics with front operating rotary handle and as per IS/IEC-60947 c\nOutgoing-\n2 nos. 25A TP MCB (1 AHU, 1 Spare)\n2 nos. 25A TP MCB c curve 10 KA (1 Humidifier, 1 Spare)\n5 nos. 16A SPN MCB c curve 10 KA\n(y) Wall-mounted front operated LT Panel (FF Other area AHU) for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design with CRCA sheet steel of 2mm thickness for frame work and covers, 3mm thickness for gland plates & 63 Amp rated Aluminium bus bar and suitable VFD fitted.\nIncoming-1 no. 40A 4P MCCB isolator (25 kA) Icu=Ics with front operating rotary handle and as per IS/IEC-60947 c\nOutgoing-\n2 nos. 16A TP MCB (1 AHU, 1 Spare)\n2 nos. 16A TP MCB c curve 10 KA (1 Humidifier, 1 Spare)\n5 nos. 16A SPN MCB c curve 10 KA\n(z) Wall-mounted front operated LT Panel (Burn OT-1,2 AHU-2 Nos) for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design with CRCA sheet steel of 2mm thickness for frame work and covers, 3mm thickness for gland plates & 63 Amp rated Aluminium bus bar and suitable VFD fitted.\nIncoming-1 no. 40A 4P MCCB isolator (25 kA) Icu=Ics with front operating rotary handle and as per IS/IEC-60947 c\n
237 237 Item No 224 Contd/-\nOutgoing-\n2 nos. 16A TP MCB (1 AHU, 1 Spare)\n2 nos. 25A TP MCB c curve 10 KA (1 Humidifier, 1 Spare)\n5 nos. 16A SPN MCB c curve 10 KA\n(aa) Wall-mounted front operated LT Panel ( OT-1,2,4 AHU-3 Nos) for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design with CRCA sheet steel of 2mm thickness for frame work and covers, 3mm thickness for gland plates & 63 Amp rated Aluminium bus bar and suitable VFD fitted.\nIncoming-1 no. 40A 4P MCCB isolator (25 kA) Icu=Ics with front operating rotary handle and as per IS/IEC-60947 c\nOutgoing-\n2 nos. 16A TP MCB (1 AHU, 1 Spare)\n2 nos. 25A TP MCB c curve 10 KA (1 Humidifier, 1 Spare)\n5 nos. 16A SPN MCB c curve 10 KA\n(ab) Wall-mounted front operated LT Panel ( OT-3 AHU) for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design with CRCA sheet steel of 2mm thickness for frame work and covers, 3mm thickness for gland plates & 40 Amp rated Aluminium bus bar and suitable VFD fitted.\nIncoming-1 no. 25A 4P MCCB isolator (25 kA) Icu=Ics with front operating rotary handle and as per IS/IEC-60947 c\nOutgoing-\n2 nos. 16A TP MCB (1 AHU, 1 Spare)\n2 nos. 16A TP MCB c curve 10 KA (1 Humidifier, 1 Spare)\n5 nos. 16A SPN MCB c curve 10 KA
238 238 Ditto all per Srl No item No 224 here-in-before but for next 11 calendar months after completion of 2nd 11 calender months. 1002 Shifts
239 239 Ditto all per Srl No item No 224 here-in-before but for next 02 calendar months after completion of 2nd 11 calender months. 183 Shifts