Military Engineer Services-MES has published Provision Of Certain Works At Cdu And Nsry Under Ge Haddo. Submission Date for this Tender is 02-06-2020. Civil Work Tenders in GE Haddo Port Blair Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 24-Mar-2020 | 8440DatePostponed2 | Date | 07-04-2020 |
2 | 06-Apr-2020 | DATE CORRIGENDUM | Date | 18-04-2020 |
3 | 16-Apr-2020 | 8440 Date | Date | 11-05-2020 |
4 | 05-May-2020 | 8440DateCorrigendum | Date | 26-05-2020 |
5 | 26-May-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 02-06-2020 |
Name of Work: PROVISION OF CERTAIN WORKS AT CDU AND NSRY UNDER GE HADDO | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. | 1110 | SQM | |
2 | 2 | Dismantling ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. | 240 | SQM | |
3 | 3 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. | 40 | CUM | |
4 | 4 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. | 6.75 | CUM | |
5 | 5 | Demolition of PCC block masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. | 3 | CUM | |
6 | 6 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed. | 1 | CUM | |
7 | 7 | Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removal of debris to outside MD land complete all as specified and as directed. | 70 | SQM | |
8 | 8 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete all as specified and as directed. | 1 | EACH | |
9 | 9 | Excavation in trenches not exceeding 1.5 metres wide and not exceeding 1.5 metres in depth, for foundation etc., or for shafts, wells, cess pits, manholes, pier holes etc not exc. 10 Sqm on plan and n.exc. 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. | 6 | CUM | |
10 | 10 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed. | 4 | CUM | |
11 | 11 | Removing excavated material (soils) to a distance exceeding 50 metres but not exceeding 100 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. | 2 | CUM | |
12 | 12 | M&L for hardcore using broken stone or boulders of gauge exceeding 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. | 60 | CUM | |
13 | 13 | M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. | 1 | CUM | |
14 | 14 | M&L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills and other similar bands, plinth courses, string courses, lacing courses, parapets and\nrailings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs including weathering, slightly rounded or chamfered angles and throating including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed. | 2.5 | CUM | |
15 | 15 | M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed. | 5 | CUM | |
16 | 16 | M&L for reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., and mass concrete complete all as specified and as directed. | 1 | CUM | |
17 | 17 | M&L for reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed. | 2 | CUM | |
18 | 18 | M&L for reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. | 1.5 | CUM | |
19 | 19 | M&L for reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as walls, retaining walls, basement walls, ballast walls and the like, any thickness, above top of footings, including attached pilaster and buttresses complete all as specified and as directed. | 2.5 | CUM | |
20 | 20 | M&L for reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, cooking platforms and in shelves and the like complete all as specified and as directed. | 0.5 | CUM | |
21 | 21 | M&L for reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in chullah hoods, stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., any section straight or winding complete all as specified and as directed. | 1 | CUM | |
22 | 22 | M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed. | 15 | SQM | |
23 | 23 | M&L for use and waste of formwork to sides of sides of pillars, posts, struts, piers, columns and stanchions (square/rectangular/polygonal) for rough finished surfaces of concrete flat complete all as specified and as directed. | 15 | SQM | |
24 | 24 | M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc., also splays between floors and beams etc., for rough finished surfaces of concrete flat complete all as specified and as directed. | 15 | SQM | |
25 | 25 | M&L for use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc., vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed. | 25 | SQM | |
26 | 26 | M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed. | 12 | SQM | |
27 | 27 | M&L for use and waste of formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing) for rough finished surfaces of concrete flat complete all as specified and as directed. | 10 | SQM | |
28 | 28 | M&L for use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete flat complete all as specified and as directed. | 10 | RM | |
29 | 29 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. | 850 | KG | |
30 | 30 | M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. | 450 | KG | |
31 | 31 | M&L for mild steel structural grade E-250 (Fe-410W Quality A) conforming to IS:2062 as in compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc., complete all as specified and as directed. | 280 | KG | |
32 | 32 | M&L for mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde E-250) Quality 'A' complete all as specified and as directed. | 450 | KG | |
33 | 33 | M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde-E-250) Quality 'A' complete all as specified and as directed. | 100 | KG | |
34 | 34 | M&L for mild steel hold fasts, bands, straps, supports or stays for rainwater, brackets/clamps for eaves/barge boards and valley gutter and similar articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. | 20 | KG | |
35 | 35 | S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based trapezoidal profile steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. \nNOTES: \nThe self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.\n | 20 | SQM | |
36 | 36 | S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/valley gutters, fixed with self tapping screws including scoffolding for a height upto 12.0 metres complete all as specified and as directed. \nNOTES: \nThe self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.\n | 8 | SQM | |
37 | 37 | S&F aluminum flat iron wind ties of any size and thickness fixed with self tapping screws for fixing roofing sheets complete all as specified and as directed. \nNOTES: \nThe self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. | 10 | KG | |
38 | 38 | M&L for 25mm thick PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in levelling course, sub base of floors and pavings complete all as specified and as directed. | 450 | SQM | |
39 | 39 | M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base of floors complete all as specified and as directed. | 400 | SQM | |
40 | 40 | M&L for sand (river sand) filling under floors or in foundations including watering and consolidation complete all as specified and as directed.\n\n | 20 | CUM | |
41 | 41 | M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. | 680 | SQM | |
42 | 42 | M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, for work on vertical surfaces such as skirting, dados and risers to steps etc., including 10mm thick backing coat in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. | 30 | SQM | |
43 | 43 | M&L for machine pressed precast concrete interlocking paver block, glossy finished, any shape and size conforming to IS 15658-2006 of 80 mm thickness, M-40 grade, made of grey cement and pigments, any pattern, laid in floors, laid dry including filleting to edges in CM (1:4) complete all as specified and as directed. | 400 | SQM | |
44 | 44 | M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in sub base of floors complete all as specified and as directed. | 90 | SQM | |
45 | 45 | M&L for glossy finished chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed.\n | 20 | SQM | |
46 | 46 | M&L for glossy finished chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 20mm thick screed bed in CM (1:6) complete all as specified and as directed.\n | 90 | SQM | |
47 | 47 | M&L for glossy finished chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in vertical surfaces such as risers to steps, set, jointed and pointed in neat cement slurry etc., including 10mm thick backing coat in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.\n | 6 | SQM | |
48 | 48 | M&L for rendering 15mm thick in two coats 5mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement over 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed.\nNOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule. | 45 | SQM | |
49 | 49 | Supply only integral water proofing compound. | 7 | KG | |
50 | 50 | M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished even and smooth without using extra cement complete all as specified and as directed.\n | 190 | SQM | |
51 | 51 | M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed. | 55 | SQM | |
52 | 52 | M&L for preparation of newly plastered surfaces of walls of any description and applying 3mm thick wall care putty in two coats (primary coat and finishing coat) for smooth surface by grinding/sanding etc., over which applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.\n | 70 | SQM | |
53 | 53 | M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by scraping, washing, cleaning etc., and applying 2mm thick wall care putty for smooth surface by grinding/sanding etc., over which applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.\n | 120 | SQM | |
54 | 54 | M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of cement based paint over a coat of primer complete all as specified and as directed.\n | 45 | SQM | |
55 | 55 | M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of distemper oil emulsion over a coat of primer after levelling the undulations if any with cement putty complete all as specified and as directed.\n | 120 | SQM | |
56 | 56 | M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by scraping, washing, cleaning etc., and applying two coats of distemper oil emulsion over a coat of primer after filling the cracks with filler and levelling the undulations if any with cement putty complete all as specified and as directed.\n | 80 | SQM | |
57 | 57 | M&L for anodised aluminium partition, window and door/ventilator with frame and shutters and grill fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed.\nNOTES:\n(i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh will be measured and paid separately under relevant items of this BOQ. \n(ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc.\n(iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose. | 25 | KG | |
58 | 58 | Supply only 4.8 mm thick sheet glass, ordinary quality and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.\n | 1.5 | SQM | |
59 | 59 | M&L for seamless gypsum board false ceiling 12 mm thick including for any sunk or raised moulding with 25mm long self drilling/tapping screws having Philips head with joining compound and 48 mm wide fibre tape to provide seam less finish and including GI frame work of seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flange of 20mm and 30 mm, web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm c/c / intermediate channel 0.9 mm thick having two equal flanges of 15 mm suspended from soffit at approx 900 mm c/c with GI cleats and steel expansion fasteners with and including ceiling section (not exceeding 1.2 m length) of 0.55 mm thick having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting across the intermediate channel at 457 mm c/c including hangers 6 mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size, 60 mm long & expansion hold fasteners 12.5 mm dia, 40 mm long and finally applying two coats of oil bound distemper with roller finish over a coat of primer complete all as specified and as directed. | 240 | SQM | |
60 | 60 | S&F 110mm bore UPVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints, laid in trenches/fixed to walls/placed in weep holes using synthetic rubber adhesive cement solvent complete all as specified and as directed.\n | 10 | RM | |
61 | 61 | S&F PVC (SWR) bends any radius, diameter of outlet 110 mm complete all as specified and as directed.\n | 4 | EACH | |
62 | 62 | Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, light fittings, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed. | 46 | POINT | |
63 | 63 | Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. | 185 | RM | |
64 | 64 | Taking down existing unserviceable main switches/ distribution boards of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. | 3 | EACH | |
65 | 65 | Taking down carefully old unserviceable light fittings only and removing from site complete all as specified and as directed. | 22 | EACH | |
66 | 66 | M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE LIGHT/FAN point controlled by one, one way 6 Amps modular switch. | 20 | POINT | |
67 | 67 | M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE LIGHT/FAN point controlled by two, two way 6 Amps modular switches. | 6 | POINT | |
68 | 68 | M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on independent board. | 10 | POINT | |
69 | 69 | M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on same board with other switches. | 2 | POINT | |
70 | 70 | M&L for Point wiring complete with 4.0 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps modular switch on independent board. | 8 | POINT | |
71 | 71 | M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed.\nNOTE: Two runs of 6.0 Sqm copper conductor, One run of 6.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length. | 75 | RM | |
72 | 72 | M&L for Sub main wiring complete with two runs (1P+1N) of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed.\nNOTE: Two runs of 4.0 Sqm copper conductor, One run of 4.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length. | 110 | RM | |
73 | 73 | S&F modular switch, one way, one module, single pole, 6 Amps complete all as specified and as directed. \n\n\n | 38 | EACH | |
74 | 74 | S&F modular socket, multipurpose, 2/3 pin combined, 2 module, single pole, 6 Amps complete all as specified and as directed.\n | 12 | EACH | |
75 | 75 | S&F modular socket, multipurpose, 2/3 pin, 6/16 Amps combined, 2 module, single pole, complete all as specified and as directed.\n | 8 | EACH | |
76 | 76 | S&F modular switch, one way, one module, single pole, 16 Amps complete all as specified and as directed. \n | 8 | EACH | |
77 | 77 | S&F modular electronic fan regulator for ceiling fan, step type, 5 speed, AC, 2 module, 120 watts, 230 volts complete all as specified and as directed. \n | 10 | EACH | |
78 | 78 | M&L for ceiling rose, three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 6A, 240 volts complete all as specified and as directed.\n | 20 | EACH | |
79 | 79 | S&F MCCB DB sheet steel enclosure, VTPN, 4-way, double door, 415 Volts with 200 Amps rated bus bar, IP-43 protection suitable for incoming MCCB 160/200 Amps and outgoing MCB TP, cement spill protector concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed.\nMAKE: L&T/ LEGRAND/ SIEMENS/ INDO ASIAN/ HAVELLS | 1 | EACH | |
80 | 80 | S&F MCB DB, SPN, 8-way, vertical type, double door, 240 Volts with 200 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed.\nMAKE: L&T/ LEGRAND/ SIEMENS/ INDO ASIAN/ HAVELLS | 2 | EACH | |
81 | 81 | S&F MCCB, 4 pole, 100 Amps, 50Hz, 16KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release complete all as specified and as directed.\nMAKE: L&T/ LEGRAND/ SIEMENS/ INDO ASIAN/ HAVELLS\n | 1 | EACH | |
82 | 82 | S&F MCB, DP, "C" series, 230 volts, 40 Amps, 10 KA rupturing capacity complete all as specified and as directed. \n | 2 | EACH | |
83 | 83 | S&F MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed. | 12 | EACH | |
84 | 84 | S&F LED light fitting 600x600mm size, new generation ceiling fitting, high efficiency, PMMA diffuser covers, recess mounted downlighter with system, 50 watts, 230 volts, IP-20 Class 1 with 4100 Lumens colour, temperature 5700K, CRCA, with built-in electronic driver, connector block etc., and all accessories pre-wired, and connecting up with and including twin core twisted flexible copper conductor of suitable size complete all as specified and as directed.\nMAKE:CROMPTON Cat Part No. LCTLRN-50-FO-CDL or equivalent in HAVELLS/BAJAJ | 12 | EACH | |
85 | 85 | S&F wall mounting ebony decorative LED light fixture having stainless steel finish with textured glass diffuser suitable for and including 9 Watts LED lamp, 230 Volts, 50 Hz AC supply and testing complete all as specified and as directed.\nMAKE: HAVELLS Cat part No. LHJE 01106499 or equivalent in PHILIPS/CROMPTON GREAVES | 10 | EACH | |
86 | 86 | M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed.\nNOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. \n2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. | 1 | EACH JOB | |
87 | 87 | Taking down carefully ceiling fan of any sweep from ceiling hook at any height after disconnecting from electricity, dismantling blades, opening up for carrying out servicing/over hauling, examining for damaged worn out parts like shaft, ball bearings etc., and applying grease to bearings, assembling back, preparing painted surfaces by cleaning dust, grease etc., and by filling cavities with filler to receive spray paint using synthetic enamel paint of existing shade and writing MES No. in synthetic enamel paint, fixing up blades and hanging back in position and providing and connecting up with 1.0 sqmm twin core twisted flexible copper conductor of suitable length from connector of fan to ceiling rose and testing complete all as specified and as directed.\nNOTE: Spare parts like ball bearings, shafts, fan blades, copper winding shall be replaced only if found damaged and certified by Engineer-in-charge. If spares are replaced, they shall be measured and paid separately as SUPPLY ONLY. A book shall be maintained for record of servicing and replacement of spares with MES Nos. of fans. | 10 | JOB | |
88 | 88 | Rewinding of ceiling fan stator by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary PVC sleeves. lead wires and testing after assembling in position in ceiling fan complete all as specified and as directed. | 5 | EACH | |
89 | 89 | SUPPLY ONLY sealed ball bearing suitable for ceiling fan with bearing No. 6201/6202 complete all as specified and as directed. | 5 | EACH | |
90 | 90 | SUPPLY ONLY shaft suitable for ceiling fan 1200mm/1400mm sweep complete all as specified and as directed. | 5 | EACH | |
91 | 91 | S&F exhaust fan blade set of 300/380mm sweep complete all as specified and as directed. | 4 | EACH SET |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail