}

Repairs Maintenance Of Summer Appliances Such As Window Ac Split Ac Water Cooler Refrigerator Deep Freezer Voltage Stabilizers And Other Allied Works Under Ge Chennai, GE Chennai-Tamil Nadu

Military Engineer Services-MES has published Repairs Maintenance Of Summer Appliances Such As Window Ac Split Ac Water Cooler Refrigerator Deep Freezer Voltage Stabilizers And Other Allied Works Under Ge Chennai. Submission Date for this Tender is 22-04-2020. Voltage Stabiliser Tenders in GE Chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

23987439
Corrigendum : Repairs Maintenance Of Summer Appliances Such As Window Ac Split Ac Water Cooler Refrigerator Deep Freezer Voltage Stabilizers And Other Allied Works Under Ge Chennai
Open Tender
Indian
Tamil Nadu
GE Chennai
22-04-2020

Tender Details

Repairs Maintenance Of Summer Appliances Such As Window Ac Split Ac Water Cooler Refrigerator Deep Freezer Voltage Stabilizers And Other Allied Works Under Ge Chennai

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Apr-2020 corrigendum3 Date 22-04-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 10 Lakhs /-

BOQ Items

Name of Work: REPAIRS/ MAINTENANCE OF SUMMER APPLIANCES SUCH AS WINDOW AC, SPLIT AC, WATER COOLER, REFRIGERATOR, DEEP FREEZER AND OTHER ALLIED WORKS UNDER GE CHENNAI
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down carefully, dismantling and opening the water coolers/ deep Freezers of any capacity/ any make after disconnecting the electric connection for attending repairs, reassembling, refixing and re-connecting the Water coolers/ Deep Freezers to power point/ connector after necessary servicing and replacing the spare parts etc., complete all as specified and directed.\nNote: (i)Servicing and replacing the spare parts shall be measured and paid separetely. \n(ii) In specific cases involving shifting to workshop and returning to work site, the same will be measured and paid separetely. BI01010001010000000000000515BI0100001208 15 JOB
2 2 Rewinding the blower fan motor of water coolers of any Make with super enamelled copper wire of same existing (original) size to get design speed for the particular make of fan motor including insulating varnishing, providing sleeves to copper wire ends all as specified and directed for the capacity of fan motor 1/5 HP (for 150 litres water cooler). 4 JOB
3 3 All as per item No.2 above but, fan motor 1/16 HP (for 120 litres water cooler) 2 JOB
4 4 All as per item No.2 above but, fan motor 1/32 HP (for 80 litres water cooler) 2 JOB
5 5 Flushing the complete condensing unit, cooling coil unit and replacement of liquid lines, strainer/ drier capillary tubes etc. and rectification of leakage from the system, vacumising, dehydrating oil and gas charging including testing and commissioning complete and all as specified and directed for the water cooler of capacity 150 litres.\nMake of Water Cooler: USHA SHRIRAM/ BLUE STAR.\nNote: Freon Gas for charging shall be measured and paid separately. 4 JOB
6 6 All as per item No. 5 above but, water cooler of capacity 120 Litres 2 JOB
7 7 All as per item No. 5 above but, water cooler of capacity 80 Litres 2 JOB
8 8 All as per item No. 5 above but, Deep freezer of capacity 200/ 585 Litres\n 2 JOB
9 9 M&L for scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint over a coat of red oxide primer to water cooler complete and all as directed for the water cooler of capacity 150 litres. \nMAKE: USHA SHRIRAM/ BLUE STAR/ VOLTAS/ SIDWAL BI01010001010000000000000515BI0100001117 3 JOB
10 10 All as per item No. 9 above but, water cooler 120 Litres capacity. BI01010001010000000000000515BI0100001148 2 JOB
11 11 All as per item No. 9 above but, water cooler 80 Litres capacity. 2 JOB
12 12 M&L for removal of entire portion of corroded base plate complete and welding with new base plate of same original gauge of MS Sheet, angle iron legs and painting with two coats of synthetic enamel paint over a coat of red oxide primer to match with existing surface for water coolers of any capacity complete all as directed. 2 JOB
13 13 Repairs to the corroded portion of the water cooler side, front and rear panels, drip tray, top lid and making good by welding with MS sheet of 20 guage and painting with two coats of synthetic enamel paint over a coat of red oxide primer to match with existing surface complete all as directed. 2 JOB
14 14 Supply only top lid hinges (set of two Nos counted as one unit) BI01010001010000000000000515BI0100001195 3 SET OF TWO
15 15 Supply only top lid gasket 4 EACH
16 16 Supply only ball brass valve with polythene float and fly nut 1/2" (15mm) size . 5 EACH
17 17 Supply only brass chromium plated 15mm dia push tap. Make: Waterman / Metro / Parryware. 8 EACH
18 18 Supply only fan motor blades suitable for 1/5 HP/ 1/6 HP/ 1/32 HP fan motors for water coolers. \nMake of fan motor: Usha Shriram/ Blue star/ Voltas/ Sidwal 3 EACH
19 19 Supply only compressor unit mounting rubber bush complete with spring plate (02 Nos counted as one unit) for water coolers. 2 SET OF TWO
20 20 Supply only fan motor capacitor 4 mFd for water coolers. \n Make: USHA/ KELTRON/ RENUTROL/ EPCOS. 8 EACH
21 21 Supply only Thermostat switch for water coolers. \n Make: Danfoss/ Infoss 3 EACH
22 22 Supply only Terminal cover with clamps for water coolers. 3 EACH
23 23 Supply only Three core 4 Sqmm PVC insulated copper wire. Make: Finolex/ Havells/ Polycab/ Gloster/ Universal. 20 RUNNING METRE
24 24 Supply only Over load protector for SR 522/ SR 1022 for water coolers of capacity 150/ 120/ 80 litres.\nMake: Usha Sriram/ Renutrol/ Keltron BI01010001010000000000000515BI0100001149 3 EACH
25 25 Supply only Starting capacitor 40-80 mFd for water coolers of capacity 150/120/80 litres.\nMake: USHA/ KELTRON/ RENUTROL/ EPCOS. BI01010001010000000000000515BI0100001207 6 EACH
26 26 Supply only running capacitor 15-30 mFd for water coolers of capacity 150/ 120/ 80 litres.\nMake: USHA/ KELTRON/ RENUTROL/ EPCOS. 6 EACH
27 27 Supply only Starting relay for compressor for water coolers of capacity 150/ 120/ 80 litres.\nMake: Usha sriram/ Renutrol/ Keltron 5 EACH
28 28 Taking out the existing unserviceable compressor unit and supply & fix new compressor unit of same make of water cooler suitable for the capacity of water cooler 80 litres including testing and commissioning etc. complete all as directed. Make of Water cooler: Usha shriram/ Bluestar/ Voltas/ Sidwal.\nNote : Freon Gas shall be measured and paid separately. 2 EACH
29 29 All as per item No. 28 above, but for Water cooler 120 Litre capacity. 2 EACH
30 30 All as per item No. 28 above, but for Water cooler 150 Litre capacity. 2 EACH
31 31 Taking down unserviceable fan motor from water cooler and supply & fix new fan motor factory made for the capacity 1/16 HP (for 150 litres water cooler/ deep freezers) conforming to IS specification and bearing ISI mark all as specified and directed. Make: AUE/ GEC. 2 EACH
32 32 All as per item No. 31 above but for Fan motor 1/32 HP (for 120/ 80 litrs water coolers). 2 JOB
33 33 All as per item No. 31 above but for Fan motor 1/32 HP (for deep freezer). 2 JOB
34 34 Taking down water cooler from site and shifting to workshop for repairs and brought back to same site and re-fixing the same in position all as directed.\nNote: Repair will be measured and paid separately. 2 JOB
35 35 Dismantling the fan motor from the refrigerator, taking out the burnt out winding and Rewinding the blower fan motor of Refrigerator of capacity 286/ 300 litres of any make with super enamelled copper wire of same existing (original) size to get design speed for the particular make of fan motor including insulating varnishing, providing sleeves to copper wire ends and refixing the same in its original position, testing and commissioning all as specified and directed. 3 JOB
36 36 Flushing the complete condensing unit, cooling coil unit and replacement of liquid lines, strainer/ drier capillary tubes etc, of refrigerators and rectification of leakage from the system, vacumising dehydrating oil and gas charging including testing and commissioning complete and all as directed for the refrigerators capacity 315/ 165 Litres. \nNote: Freon Gas for charging shall be measured and paid separately. 4 JOB
37 37 M&L for renewal of entire portion of corroded base plate complete and welding with new base plate of same original existing gauge of MS Sheet and painting with two coats of synthetic enamel paint over a coat of red oxide primer to match with existing surface for refrigerators of capacity 165/ 200 litres of any make. 4 EACH
38 38 All as per item No. 37 above but, for 286/ 315 litres capacity of any make. \n 2 EACH
39 39 Scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint over a coat of red oxide primer for capacity of the refrigerators 165/ 200 litres capacity of any make. 2 EACH
40 40 All as per item No. 39 above but, for 286/ 315 litres capacity of any make. \n 2 EACH
41 41 M&L for replacement of cabinet light switch for refrigerators of any make and capacity. 4 EACH
42 42 M&L for replacement of cabinet light bulbs for refrigerators of any make and capacity. 5 EACH
43 43 M&L for replacement of mounting rubber bush for compressor (3 Nos counted as one unit) 4 SET OF THREE
44 44 M&L for replacement of auto defrost type thermostat switch for refrigerator of any capacity. 4 EACH
45 45 M&L for replacement of starting relay pin type 4 EACH
46 46 M&L for replacement of overload protector 1/8 HP/ 1/6 HP 3 EACH
47 47 M&L for replacement of BI metal relay for refrigerator of any capacity. 2 EACH
48 48 M&L for replacement of timer switch for refrigerator of any capacity. 4 EACH
49 49 M&L for replacement of leg pin/ screw type for refrigerators (4 Nos one set).\nMake for item Nos. 41 to 49: Suitable make of exisiting refrigerator. 3 SET OF FOUR
50 50 M&L PVC insulated and sheathed multistranded three core cable with copper conductor of 48 strands fixed in replacement all as specified and directed.\nMake: Finolex/ Havells/ Plaza/ Standard. 20 RUNNING METRE
51 51 M&L for replacement of magnetic door gasket for refrigerators of capacity 165/ 200 litres of make Kelvinator/ LG/ Whirlpool/ Samsung/ Voltas all as directed. 2 EACH
52 52 M&L for replacement of shelves set for refrigerators of capacity 165/ 200 litres of make Kelvinator/ LG/ Whirlpool/ Samsung/ Voltas all as directed. 3 SET
53 53 M&L for replacement of vegetable tray with glass cover for refrigerators of capacity 165/ 200 litres of make Kelvinator/ LG/ Whirlpool/ Samsung/ Voltas all as directed. 2 EACH
54 54 M&L for replacement of freezer door for refrigerators of capacity 165/ 200 litres of make Kelvinator/ LG/ Whirlpool/ Samsung/ Voltas all as directed. 2 EACH
55 55 M&L for replacement of ice tray for refrigerators of capacity 165/ 200 litres of make Kelvinator/ LG/ Whirlpool/ Samsung/ Voltas all as directed.\nNote for item No. 51 to 55: Spare shall be of same make of refrigerator and shall conforming to IS specification. 2 EACH
56 56 M&L for replacement of magnetic door gasket for refrigerators of capacity 286/ 315 litrs of make Kelvinator/ LG/ Wirlpool/ Samsung/ Voltas all as directed. 2 EACH
57 57 M&L for replacement of shelves set for refrigerators of capacity 286/ 315 litrs of make Kelvinator/ LG/ Wirlpool/ Samsung/ Voltas all as directed. 2 SET
58 58 M&L for replacement of ice tray for refrigerators of capacity 286/ 315 litrs of make Kelvinator/ LG/ Wirlpool/ Samsung/ Voltas all as directed. 3 EACH
59 59 M&L for replacement of vegetable tray with glass cover for refrigerators of capacity 286/ 315 litrs of make Kelvinator/ LG/ Wirlpool/ Samsung/ Voltas all as directed. 2 EACH
60 60 M&L for replacement of freezer door for refrigerators of capacity 286/ 315 litrs of make Kelvinator/ LG/ Wirlpool/ Samsung/ Voltas all as directed.\nNote for item No. 56 to 60: Spare shall be of same make of refrigerator and shall conforming to IS specification. 2 EACH
61 61 Taking out the existing unserviceable compressor unit and supply & fix new compressor unit of same make as that of refrigerator suitable for 165/ 200 litrs refrigerators including testing and commisioning etc. complete all as directed. \nNote: Supply only of Freon gas charging shall be measured and paid for separately. 2 EACH
62 62 Taking out the existing unserviceable compressor unit and supply & fix new compressor unit of same make as that of refrigerator suitable for 285/ 315 litrs refrigerators including testing and commisioning etc. complete all as directed. \nNote: Supply only of Freon gas charging shall be measured and paid for separately. 2 EACH
63 63 Supply only Freon Gas R-134A for charging to refrigerator/ water cooler/ deep freezers. 15 KILO GRAM
64 64 Dismantling the fan motor from the window type AC of capacity 1.5 Ton of any make, taking out the burnt out winding and rewinding the motor with super enamelled copper wire of existing gauge to get designed speed including insulating, varnishing, providing sleeves to copper wire ends and refixing the same on its original position, testing and commissioning all as specified and directed. 3 JOB
65 65 Flushing the complete condensing unit, evaporator coil unit, compressor suction and delivery tubes and replacement of charging lines, strainers capillary tube etc., of window type AC and rectification of the leakage from the system, vaccumising, dehydrating, oil and gas charging including testing and commissioning of system all as directed.\nNote: Supply only of Freon gas for charging shall be measured and paid separately. 3 JOB
66 66 M&L for replacement of condensing coil and housing of the unit of any make of window type AC all as sapecified and directed. 2 EACH
67 67 M&L for replacement of cooling coil unit and housing the unit of any make of window type AC all as specified and directed. 3 EACH
68 68 M&L for renewal of corroded base plate by welding new MS sheet of gauge as existing (original) and painting with two coats of synthetic enamel paint over a coat of red oxide primer to match with existing surface for window type AC complete all as specified and directed. 3 EACH
69 69 All as per item No. 68 above but Cooling coil housing, side and top plate. 2 EACH
70 70 All as per item No. 68 above but Fan motor base. 2 EACH
71 71 All as per item No. 68 above but Condensor coil housing side and top plate. 2 EACH
72 72 M&L for replacement of evaporator coil for the 1.5 ton capacity window type air conditioners of any make all as directed.\nNote: The spares shall be of same make as that of AC (or) of existing spare and shall conforming to IS specification 2 EACH
73 73 All as per item No. 72 above but Condensor coil 2 EACH
74 74 All as per item No. 72 above but Standard outer cover. 2 EACH
75 75 All as per item No. 72 above but Front grill. BI01010001010000000000000515BI0100001192 3 EACH
76 76 All as per item No. 72 above but Fan blade with squirel 3 EACH
77 77 All as per item No. 72 above but Fan motor 1/5 HP 3 EACH
78 78 All as per item No. 72 above but Rubber bush and MS clamp with bolts & nuts for motor 2 EACH
79 79 All as per item No. 72 above but Starting relay 1622. 2 EACH
80 80 All as per item No. 72 above but Starting capacitor 80-100 mFd. 3 EACH
81 81 All as per item No. 72 above but running capacitor suitable mfd for the driven machine. 3 EACH
82 82 All as per item No. 72 above but fan motor capacitor 4/6 mFd. 3 EACH
83 83 All as per item No. 72 above but Thermostat switch 2 EACH
84 84 M&L multi stranded 4 sqmm three core wire PVC insulated sheathed with copper conductor for window type AC all as specified and directed. \nMake: Finolex/ Havells/ Plaza/ Standard 25 RUNNING METRE
85 85 M&L for replacement of compressor terminal cover with clamp for window type AC all as directed. 3 EACH
86 86 M&L for replacement of compressor mounting rubber bush for window type AC all as directed.\n(set of 3 Nos counted as one unit). BI01010001010000000000000515BI0100001112 5 SET OF THREE
87 87 M&L for replacement of remote control with PCB for window type AC all as directed. BI01010001010000000000000515BI0100001113 4 EACH
88 88 S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 30 Amps for incoming and out going control complete all as specified and directed.\nMake: Standard/ Havells/ Seimens/ L&T. BI01010001010000000000000515BI0100001114 5 EACH
89 89 M&L for cleaning the evaporator and condenser unit assembly of window type air conditioners with castic soda wash including scraping, removal of rust and complete removal of existing painting and applying spray painting with two coats of synthetic enamel paint over a coat of red oxide primer completev all as directed. BI01010001010000000000000515BI0100001146 4 JOB
90 90 Taking out the existing unserviceable compressor unit from window type AC and supply & fix new hermetically sealed rotary/ piston type compressor unit of capacity 1.5 ton and of same make as that of window type AC suitable to operate in AC single phase 50 HZ 230 volts including testing and commisioning etc., complete all as specified and directed. \nNote: Freon gas for charging shall be measured and paid for separately. BI01010001010000000000000515BI0100001150 5 JOB
91 91 Taking out the existing unserviceable compressor unit from Split type AC and supply & fix new hermetically sealed rotary/ piston type compressor unit of capacity 1.5 & 2.0 ton of same make as that of Split type AC suitable to operate in AC single phase 50 HZ 230 volts for split type AC including testing and commisioning etc. complete all as specified and directed. \nNote: Freon Gas for charging shall be measured and paid separately. 23 EACH
92 92 Flushing the complete condensing unit, evaporator coil unit, compressor suction and delivery tubes and replacement of charging lines, strainers capillary tube etc. of split type AC and rectification of the leakage from the system, vaccumising. dehydrating as per standard practice and gas charging including testing and commissioning of system complete all as directed.\nNote: Freon gas for charging shall be measured and paid separately. 20 EACH
93 93 M&L for replacement of fan motor of 1/6 HP RPM 950 AC single phase 50 HZ evaporator coil for the split type air conditioners of any make complete all as directed.\nNote: The spares shall be of same make of AC (or) of existing spare and shall conforming to IS specifications. 10 EACH
94 94 All as per item No. 93 above but Freon gas outlet control regulator. 10 EACH
95 95 All as per item No. 93 above but Freon gas inlet control regulator. 10 EACH
96 96 All as per item No. 93 above but compressor base plate. 10 EACH
97 97 All as per item No.93 above but Condensor coil/ Evaparator coil (or) cooling coil. 10 EACH
98 98 All as per item No. 93 above but Hand smart remote control with PCB. 10 EACH
99 99 All as per item No. 93 above but Fan motor for condensing unit (outdoor unit). 10 EACH
100 100 Dismantling Voltage stablizer of any make and of capacity 5 KVA and transporting to workshop to detect/ identify the nature of defects/ repairs and reassembling and refixing after repairs/ servicing including testing and commissioning etc. complete all as specified and directed. 3 EACH
101 101 All as per item No. 100 above but 4 KVA. 3 EACH
102 102 Dismantling/ taking down transformer from 5 KVA stablizer, removing the burnt out winding and rewinding the transformer with super enameled copper wire of size as per existing (original) including insulating, varnishing and providing sleeves etc. and refixing in the stablizers in original position complete all as specified and directed. 3 EACH
103 103 All as per item No. 102 above but 4 KVA. 3 EACH
104 104 Removing the transformer from stablizer of capacity 5 KVA, cleaning varnishing with shellac including replacement of insulating sleeves etc. and refixing in the stablizer in original position complete all as specified and directed.\nNote: Replacement of insulating parts /defective items will be measured and paid separately. 3 EACH
105 105 All as per item No. 104 above but 4 KVA. 5 EACH
106 106 Supply only Relay set (set of two) for voltage stabilizer of capacity upto 5 KVA all as directed.\n 3 SET OF TWO
107 107 Supply only PCB (Printed circuit board) for voltage stabilizer of capacity upto 5 KVA all as directed.\n 2 EACH
108 108 Supply only Three core wire for voltage stabilizer of capacity upto 5 KVA all as directed.\n 20 RUNNING METRE
109 109 Supply only Indicating lamp for voltage stabilizer of capacity upto 5 KVA all as directed.\n 3 EACH
110 110 Supply only Fuse unit for voltage stabilizer of capacity upto 5 KVA all as directed.\n 2 EACH
111 111 Replacement of unserviceable Indoor unit of split type AC 1.5 Ton capacity all as directed.\nMake: BLUESTAR/ LG/ CARRIER/ VOLTAS/ SIDWAL/ Hitachi 13 EACH
112 112 Supply only freon gas R-404A for charging to window/ split type AC's. 75 KILO GRAM
113 113 Taking down window type AC of any capacity by carefully disconnecting the electric connection and carrying out water washing, cleaning the filter and cooling coil and refixing the same in position including testing and commissioning complete all as specified and directed. 6 JOB
114 114 Taking down split type AC of any capacity by carefully disconnecting the electric connection and carrying out water washing, cleaning the filter and cooling coil and refixing the same in position including testing and commissioning complete all as specified and directed. 15 JOB
115 115 Removing from existing location and shifting of split type AC of any capacity and fix factory made fabricated support suitable to mount outdoor unit (one pair per AC including drilling holes in walls for insertion of copper pipe, drain pipe and three core cable and making good the surfaces complete all as specified and directed. 15 JOB
116 116 Removing from existing location and shifting of window type AC of any capacity and fix with suitable wooden frame with second class hardwood in new location including providing three core cable and making good the surfaces complete all as specified and directed. 3 JOB
117 117 S&F in replacement 1/4 inch dia copper pipe with insulation tubular form for split type AC all as specified and directed. 20 RUNNING METRE
118 118 S&F in replacement 1/2 inch dia copper pipe with insulation tubular form for split type AC all as specified and directed. 20 RUNNING METRE
119 119 S&F in replacement 3/8 inch dia copper pipe with insulation tubular form for split type AC all as specified and directed. 20 RUNNING METRE
120 120 S&F in replacement 5/8 inch dia copper pipe with insulation tubular form for split type AC all as specified and directed. 20 RUNNING METRE
121 121 S&F in replacement angle set for outdoor unit of split type AC all as specified and directed. 5 EACH SET
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail