Military Engineer Services-MES has published Tender For Special Repair/Replacement Of Ber Refrigerator Water Cooler Deep Freezer Of Various Capacity At Wecors Bldg No 42 , Other Bldg/Work Shop Area Provn Of 03 No 1 . 5 Tr Split Ac Qad Bldg No P 43A , Provn Of Solar Heater In Bldg No 48 , Bldg No. Submission Date for this Tender is 30-03-2020. Freezer Tenders in NAVAL DOCKYARD VISAKHAPATNAM Andhra Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: SPECIAL REPAIR/REPLACEMENT OF BER REFRIGERATOR, WATER COOLER, DEEP FREEZER OF VARIOUS CAPACITY AT WECORS (BLDG NO 42) AND OTHER BUILDINGS/WORK SHOP AREA, PROVISION OF 03 NOS 1.5 TR SPLIT AC'S QUALITY ASSURANCE DEPTT, BUILDING NO P-43A AND PROVISION OF SOLAR HEATER IN BLDG NO 48 & BLDG NO 49 AT NAVAL DOCKYARD VISAKHAPATNAM | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking out unserviceable wiring and M&L for wiring with 2 x 1.0 core PVC insulated standard copper conductor FRLS grade 6 sqmm for phase & neutral and 1 x 1.0 core PVC insulated standard copper conductor FRLS grade 6sq mm wire green colour for earth contunity in medium grade PVC conduit with all accessories complete all as specified and as directed\n | 1180 | RM | |
2 | 2 | Taking out unserviceable wiring and M&L for wiring with 2 x 1.0 core PVC insulated standard copper conductor FRLS grade 2.5 sqmm for phase & neutral and 1 x 1.0 core PVC insulated standard copper conductor FRLS grade 2.5 sq mm wire green colour for earth contunity in medium grade PVC conduit with all accessories complete all as specified and as directed\n | 750 | RM | |
3 | 3 | Taking out all electric connetion, water connection of Refrigerator, Water Cooler and Deep freezer of any capacity, transportation and deposite to MES store complete all as specified and as directed. | 48 | Each | |
4 | 4 | Supply,installation and commissioning of Refrigerator electric driven (single phase) 240 V, 50 Hz of capacity 170 Ltrs complete all as specified and as directed. \nMake :- LG/Haier/Whilpool/Sumsung | 2 | Each | |
5 | 5 | Supply,installation and commissioning of Water cooler fully stainless steel, electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 litres per hour complete all as specified and as directed.\nMake:- Blue Star/Voltas. | 18 | Each | |
6 | 6 | Supply, installation and commissioning of Water cooler fully stainless steel, electric driven (single phase), having approx storage capacity of 120 litre and nominal cooling capacity of 60 litres per hour complete all as specified and as directed. \nMake:- Blue Star/Voltas. | 7 | Each | |
7 | 7 | Supply, installation and commissioning of Water cooler fully stainless steel, electric driven (single phase), having approx storage capacity of 150 litre and nominal cooling capacity of 150 litres per hour complete all as specified and as directed. \nMake:- Blue Star/LG/Haier/Voltas. | 17 | Each | |
8 | 8 | Supply, installation and commissioning of Deep freezer hard top 500 litres capacity having single door Electric driven (single phase) complete all as specified and as directed. \nMake:- Blue Star/Voltas. | 2 | Each | |
9 | 9 | Supply, installation and commissioning of Deep freezer hard top 210 litres capacity having single door Electric driven (single phase) complete all as specified and as directed.\n Make:- Blue Star/Voltas. | 2 | Each | |
10 | 10 | Taking out unserviceable 15 A switch socket combination, Supply and fix 15 A switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and as directed. | 48 | Each | |
11 | 11 | Supply & fix 15mm dia GI Pipe medium grade including fittings such as tee, bend, nipple, etc., and fixed complete to walls or laid in floors including taking down the corroded pipes complete all as specified and as directed. \n | 150 | RM | |
12 | 12 | Taking out defective PVC flexible connector, supply & fix heavy duty PVC flexible connector ISI marked 15mm dia and 450mm long union, nuts & washers on either end complete all as specified and as directed. \nMake :- Panna | 45 | Each | |
13 | 13 | Supply & fix stop valve of fancy type chromium plated copper alloy 15mm bore with one GI union and GI nipple on the in-let connection of water cooler complete all as specified and as directed.\n\n | 45 | Each | |
14 | 14 | Supply, fix and install Hi wall split units indoor/outdoor, copper condenser coil & copper evaporator coil complete, electric driven, single phase, with cordless remote control unit and with in build air ioniser and plasma filter for better indoor air quality of capacity 1.5 TR minimum with 3 star all copper tubes complete all as specified and as directed. \nMake:- Voltas/Carrier/LG. | 3 | Each | |
15 | 15 | Supply and fix Voltage stabilizer for automatic operation, single Phase, naturally air cooled, split type and designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 4 KVA complete all as specified and as directed. \nMake:- V-Guard or equivalent. | 3 | Each | |
16 | 16 | Material & labour for 2 Runs 6 sqmm FRLS grade copper wiring for phase & neutral and 6 Sq mm copper wire green for earth contunity in 25 mm heavy grade PVC conduit with all accessories complete all as specified and as directed. \n | 63 | RM | |
17 | 17 | Supply and fix sheet metal enclosures with socket plug top and 20 Amp Single pole MCB complete all as specified and as directed.\nMake:- Indoasian/Schneider/Havells . | 3 | Each | |
18 | 18 | Supply & Install of Solar water heating system,flat plate collector type with heat exchanger of 500 litre per day capacity with electrical heating backup comprising solar tubular plate, Hot water tank, Mounting steel structure for plate & hot water tank complete all as specified and as directed | 2 | Each | |
19 | 19 | Supply and laying of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified for the size 32mm outer dia complete all as specified and as directed | 20 | RM | |
20 | 20 | Supply and laying of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified for the size 25mm outer dia | 10 | RM | |
21 | 21 | Supply and laying of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified for the size 20 mm outer dia | 60 | RM | |
22 | 22 | Supply and hoist Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of size 675 ltr capacity complete all as specified and as directed | 2 | Each | |
23 | 23 | Supply and fix structural steel work of staging for water tanks and the like including caps, bases, splices etc, built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc using Fe 410-W (Gde E-250) quality A grade steel complete all as specified and as directed | 300 | Each | |
24 | 24 | Supply and fix CPVC Ball Valve 32 mm outer dia complete all as specified and as directed | 4 | Each | |
25 | 25 | Supply and fix CPVC Ball Valve 25 mm outer dia complete all as specified and as directed | 4 | Each | |
26 | 26 | Supply and fix CPVC Ball Valve 20 mm outer dia complete all as specified and as directed | 4 | Each | |
27 | 27 | Supply and fix Bib tap standard or PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm 90gms/20mm-125gms) complete all as specified and as directed | 6 | Each | |
28 | 28 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium, conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. 2 core mm nominal cross section in service connections complete all as specified and as directed | 100 | RM | |
29 | 29 | Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB of 16 amps capacity complete all as specified and as directed | 2 | Each | |
30 | 30 | Supply and fix sheet metal enclosures for DB's when MCBs to be used for 2 way complete all as specified and as directed | 2 | Each | |
31 | 31 | Supply and fix RCCBs for earth leakage, overload & short circuit protection double pole 30 MA, 16 Amps complete all as specified and as directed | 2 | Each | |
32 | 32 | Material & labour for wiring for submain wiring alongwith earth wire with the 2 x10.0 sqmm + 1 x 6.0 sqmm earth wire sizes of FRLS PVC insulated multistranded copper conductor, single core cable in surface/recessed as required in and including PVC conduit complete all as specified and as directed | 10 | RM | |
33 | 33 | Material & labour for Earthing complete with Cast iron pipe electrode, 100 mm bore, Class LA, 2.5 mtr long buried directly and vertically in ground with top edge at ground level after making manual bore hole of size not less than 400 mm dia and 2.5 Mtr long near the specified bldg, connected with galvanised steel strip earthing lead of size 32mm x 6mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with RCC precast pit cover slab 80mm thick with handle for lifting made out of 8mm dia MS rod, wiremesh, charcoal and salt in alternate 150mm thick layers around CI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion after dismantling taking out unserviceable one complete all as specified and as directed | 2 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy