Military Engineer Services-MES has published Repair Maintenance Of Window Split air conditioner Refrigerator Water Cooler Ros And Other Connected Works Under Ge Army Dhar Road. Submission Date for this Tender is 15-04-2020. Air Conditioner Tenders in Dhar Road Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 26-Mar-2020 | Corr for postponement of date due to outbreak of COVID-19 | Date | 15-04-2020 |
Name of Work: Repair and maint of window/split ACs Refrigerator , Water cooler, ROs and other connected work under GE Army Dhar Road Udhampur | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Disconnection of suction and discharge line connection of sealed unit and taking out the defective sealed unit compressor from window type AC/split AC of any make replacing the defective compressor with any repaired old serviceable compressor , refixing the compressor in the original position of window/split type AC making all existing connection complete all as directed for 1.5/2.0 ton Air conditioners. ( Note :- Charging of Gas R-22 shall be measured & paid separately under relevent item) | BI01010001010000000000000515BI0100001113 | 5 | Each Job |
2 | 2 | Supply and fixing in replacement of compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection and shall confirm to IS 10617, making all existing connection complete all as directed for 1.5/2.0 ton Window type/split type Air conditioners all as directed . | 8 | Each Job | |
3 | 3 | Charging of refrigerant Gas F 22/ R-134A in the sealed system of of Window type Air conditioners/split type ACs 1.5 /2Ton capacity after checking leakage /pressure vacumising flushing the sealed unit in satisfactory working condition all as specified. | 15 | Kilogram | |
4 | 4 | Taking down for servicing of window/Split AC 1.5 ton/2.0 Ton capacity and cleaning /serviceing of AC, overhauling of cooling coil, air filters/plasma filters etc (indoor ) condenssors , fan motors etc (outdoor unit) with vacum cleaner or other cleaning solution incl checking the servicivelty for other components working condition all as specified and directed Note : Replacement of defective parts/ spares will be measured and paid seperatly under relevent items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted. | 20 | Each | |
5 | 5 | Supply only the following defective spares parts of split /window AC unit of 1.5/2.00 TR against above item ;- | |||
6 | 6 | (a) Blower motor 1/6 HP with base/ rubber bush complete Make AUE/GE | 8 | Each | |
7 | 7 | (b). Condensor fan motor 1/5 HP make AUE/GE as per sample. | 5 | Each | |
8 | 8 | (c Condensor fan blade. | 4 | Each | |
9 | 9 | (d). Drum type blower fan PVC type | 2 | Each | |
10 | 10 | (e). Running capacitor 36 mfd make EPCOS. | 4 | Each | |
11 | 11 | (f). Running capacitor 45 mfd make EPCOS. | 4 | Each | |
12 | 12 | (g). Starting capacitor 100 to 120 mf Make : "TESLA" | 4 | Each | |
13 | 13 | (h). Selector switch. | 4 | Each | |
14 | 14 | (j). Thermostate make Indfoss. | 4 | Each | |
15 | 15 | (k). Starting relay make Ranutrol. | 4 | Each | |
16 | 16 | (l). Cooling coil assembly. | 5 | Each | |
17 | 17 | (m). Condensor coil assembly. | 5 | Each | |
18 | 18 | (n). Wiring kit. | 3 | Each | |
19 | 19 | (o). Capacitor 6 mfd | 3 | Each | |
20 | 20 | (p). Blower motor 1/30 HP for in door unit split type AC. | 2 | Each | |
21 | 21 | q) Main printing circuit board (PCB) with electric accessores and sensors suitable for split AC cap 1.5/2 TR | 7 | Each | |
22 | 22 | M&L for detecting the leakage of gas of split/window type AC 1.5/2 TR from any location and rectified /stoped the leakage by gas weilding or any other materials and made it functioning as directed . | 8 | Each job | |
23 | 23 | WATER COOLERS | |||
24 | 24 | Disconnection of the compressor from suction and discharge line and taking out the sealed unit compressor from water cooler of any make ,replacing the defective compressor with repaired old serviceable compressor from any of the authorised repair workshop /manufacturer, refixing the repaired compressor in the original position of the water cooler making all existing connection for for any capacitiesas directed | 8 | Each Job | |
25 | 25 | Supply and fix in replacement of new compressor hermetically sealed type with suitable rated capacity electric motor and shall be equipped with over load protection, 230 volt, 50 HZ, single phase suitable for water cooler any capacity incl warrenty as per menufacturers | 10 | Each Job | |
26 | 26 | M&L for gas refrigent F-22/R-134A in the sealed system of water cooler any make and capacity after checking the leakage / pressure vacuminising flushing the sealed system including replacement of capilary Tube, Gas filter all as directed. | 10 | Kilogram | |
27 | 27 | Dismantling and supply and fixing the blower moter of water cooler 1/32 HP, 1250 RPM capacity, 230 volts single phase and taking out burnt out copper winding wire from moter and M&L for rewinding the electric motor with super enameled copper winding wire of same size and gauge including insulation material, varnish and reassemble and refixing the motor complete including replacement of unserviceable spares all as directed. | 5 | Each Job | |
28 | 28 | Disconnection from mains for servicing of water cooler of cap upto 180 Ltrs and cleaning /serviceing , overhauling of cooling coil with vacum cleaner or other cleaning solution incl checking the servicivelty for other components working condition all as specified and directed Note : Replacement of defective parts/ spares will be measured and paid seperatly under relevent items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted. | 20 | Each Job | |
29 | 29 | Supply only the following defective spares parts of water cooler any cap against above item ;- | |||
30 | 30 | Supply of thermostat switch for water cooler. | 7 | Each | |
31 | 31 | Supply of starting relay for water cooler. | 5 | Each | |
32 | 32 | Supply of starting capacitor 40-60 mfd ,230 volt ,50Hz, confirming to IS 2993 for water cooler. | 4 | Each | |
33 | 33 | Supply of starting capacitor capacity 60-80 MFD. | 4 | Each | |
34 | 34 | Supply of Running capacitor 15 Mfd , 415volt,50Hz . | 10 | Each | |
35 | 35 | Supply of Running capacitor 10 Mfd , 415volt,50Hz . | 4 | Each | |
36 | 36 | Supply of Running capacitor 6 Mfd , 415volt,50Hz . | 4 | Each | |
37 | 37 | Supply of Running capacitor 36 Mfd , 415volt,50Hz . | 10 | Each | |
38 | 38 | Supply PVC float valve with rod and plastic ball suitable for 1/2" bore of watercooler for blue star fittings | 4 | Each | |
39 | 39 | Supply of over load protector (OLP) for water cooler of any capacity complete all as specified and directed. | 5 | Each | |
40 | 40 | Supply of self closing Push cock 15mm bore chromium plated brass heavy duty longthread ( As per sample). | 5 | Each | |
41 | 41 | Supply of aluminium blade for blower motor of water cooler 40/60/120 Ltrs | 5 | Each | |
42 | 42 | Supply blower motor 1/32 HP 230 volt suitable for water cooler complete with base frame/and rubber bush make AUE/GE. | 5 | Each | |
43 | 43 | Supply of water tank gasket for water cooler 40/80 ltr cap. | 2 | Each | |
44 | 44 | Supply of wiring kit complete for water cooler. | 5 | Each | |
45 | 45 | Supply of PVC pipe low density 25 mm dia flexible pipe with two clamp complete & all as specified. | 4 | RM | |
46 | 46 | Supply and fixing in replacement PVC connection pipe with brass union of 15 mm bore in both end suitable for water cooler connection of length not less than 600 mm long. | 10 | Each | |
47 | 47 | Supply and fixing PVC pipe flexible type 40 mm dia for drain system and connection all as directed. | 30 | Running Metre | |
48 | 48 | Refrigerator /Deep Freezer | |||
49 | 49 | Disconnection from mains for servicing of Refrigerator/Deep freezer of cap 165 to 310 Ltrs and cleaning /serviceing , overhauling of cooling coil with vacum cleaner or other cleaning solution incl checking the servicivelty for other components working condition all as specified and directed Note : Replacement of defective parts/ spares will be measured and paid seperatly under relevent items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted. Supply only the following defective spares parts of Refrigerator/ Deep freezer any cap against above item ;- | 15 | Each Job | |
50 | 50 | Supply of thermostat switch | 7 | Each | |
51 | 51 | Supply of starting relay | 8 | Each | |
52 | 52 | Supply of starting capacitor 40-60 mfd ,230 volt ,50Hz, confirming to IS 2993 for water cooler. | 4 | Each | |
53 | 53 | Supply of Running capacitor 15 Mfd , 415volt,50Hz . | 10 | Each | |
54 | 54 | Copper filter single capillary pencile type | 8 | Each | |
55 | 55 | Disconnection of the compressor from suction and discharge line and taking out the sealed unit compressor from water cooler of any make ,replacing the defective compressor with repaired old serviceable compressor from any of the authorised repair workshop /manufacturer, refixing the repaired compressor in the original position of the Refrigerator /Deep freezer making all existing connection for any capacities. | 5 | Each Job | |
56 | 56 | Supply and fix in replacement of new compressor hermetically sealed type with suitable rated capacity refrigerator of any make and type and providing and fixing new compressor suitable for 165 to 310 ltr refrigerator and testing the same with gurantee as per manufacturers incl charging of the refrigent gas F-12m R-134 A and all other copper tubes capillary and filter and put in working condition all as directed | 8 | Each Job | |
57 | 57 | M&L for gas refrigent F-22/R-134A in the sealed system of Refrigerator / Deep frezeer any make and capacity after checking the leakage / pressure vacuminising flushing the sealed system including replacement of capilary Tube, Gas filter all as directed. | 5 | Kilogram | |
58 | 58 | RO water purification | |||
59 | 59 | Repair and maint of RO water purification system of any make complete with replacement of unserviceable parts and making the system serviceablr as per manufacturers accessories Note :- New parts will be measured and paid seperatly under respective item under supply only . labour charge will be deemed in quoted rate . | 8 | Each Job | |
60 | 60 | Supply only micro spun 20 Make Renuka RWI 107 | 6 | Each | |
61 | 61 | supply only CTO 20 Make Renuka RWI 109 | 6 | Each | |
62 | 62 | Supply only membrane housing 50 Make Renuka RWI 125 | 6 | Each | |
63 | 63 | Supply only UV system 100 Make Renuka RWI 137 | 6 | Each | |
64 | 64 | Supply only flow restrictor adjuster Make Renuka RWI 134 | 6 | Each | |
65 | 65 | Supply only micronic membrane 50 Make Renuka RWI 127 | 6 | Each | |
66 | 66 | Supply only connecting pipe PVC | 40 | Running Metre | |
67 | 67 | Supply only sedimentation filter | 6 | Each | |
68 | 68 | Supply only Motor and pump for RO | 6 | Each | |
69 | 69 | Geyser | |||
70 | 70 | Supply and fixed heating element 1500 watt push/screw/ triangular type suitable for 25 ltrs capacity geysers ISI marked complete all as directed by Engr-in-Charge. | 30 | Each | |
71 | 71 | Supply and fixed heating element 2000 watt push/screw/ triangular type suitable for 25 ltrs capacity geysers ISI marked complete all as directed by Engr-in-Charge. | 60 | Each | |
72 | 72 | Supply and fixed thermostat switch suitable for 25/50 Ltrs capacity geyser of any make/ type with temperature range adjustable from 25 to 90 degree centigrade superior quality 20 Amp rating 220 volt AC supply complete. | 60 | Each | |
73 | 73 | Supply and fixed PVC flexible connection with two brass adopter as per existing samples/ suitable of carrying hot water fixed one end at geyser inlet / outlet water supply point complete . | 60 | Each | |
74 | 74 | Supply and fixing indicator lamp suitable for 220 volts AC supply circular/ rectangular (green/ red) as per sample with neon lamp of superior quality complete . | 30 | Each | |
75 | 75 | Painting of Geyser of any size 25/50 Ltrs with existing colour enameled approved spray paints one coat after cleaning dust etc all as directed | 60 | Each | |
76 | 76 | Supply and fixing geyser 25 Ltrs inner tank copper moulded alongwith all connection complete all as specified and directed | 10 | Each | |
77 | 77 | Supply and fixing geyser 50 Ltrs inner tank copper moulded alongwith all connection complete all as specified and directed | 5 | Each | |
78 | 78 | Supply and fixing geyser assembly any type including packing and gasket materials as per existing any type 25/50 Ltrs Geyser all as specified and directed. | 30 | Each | |
79 | 79 | Ceiling & Exhaust Fan | |||
80 | 80 | Taking down and refixing after recify the defects carefully of ceiling fan any size and any sweep including dismantling of blades, down rods fan for recognize defects at site or deposit to store complete all as directed by Engineer-in-Charge. | 800 | Each | |
81 | 81 | Taking down and refixing after recify the defects carefully of exhaust fan any size and any sweep including dismantling of blades, for recognize defects at site or deposit to store complete all as directed by Engineer-in-Charge. | 60 | Each | |
82 | 82 | Labour work for overhauling of ceiling fan any Make and sweep including dismantling, cleaning internally and externally, oiling, greasing, checking of electric connections, replacement of worn out check nuts, split pins, nuts, bolts and washers, sockets rebber real, clamps and minor repairing works and items etc. reassembling and testing on completion all as directed. Note :- Winding works will be taken seperatly . Other items will be measured and paid seperatly. | 800 | Each | |
83 | 83 | All as specified in item No.31 here-in-before but for exhaust fan/wall fan/fresh air fan etc of any Make and any size. | 60 | Each | |
84 | 84 | Painting of ceiling fan of any size sweep including blades and canopies with white enameled approved spray paints one coat after cleaning dust etc and Marking of MES No ceiling fan such as MES No, and height of letter 2.5 cm in figures including sign writing with black enameled paints all as directed | 500 | Each | |
85 | 85 | Painting of Exhaust fan of any size sweep including blades and canopies with white enameled approved spray paints one coat after cleaning dust etc and Marking of MES No Exhaust fan such as MES No, and height of letter 2.5 cm in figures including sign writing with black enameled paints all as directed | 60 | Each | |
86 | 86 | Removing the burnt copper winding of ceiling fan ,cleaning to cores and rewinding of ceiling fans with copper enameled wire of suitable size including film paper, sleaving and varnishing , 56” (1400mm) complete any make any type as directed by Engr-in- Charge . | 150 | Each | |
87 | 87 | All as per item No 7 above but 48”(1200 mm) sweep any make and any size | 500 | Each | |
88 | 88 | All as per item No 7 above but exhaust fan 18” sweep 450mm complete any make all as directed by Engr-in- Charge | 50 | Each | |
89 | 89 | All as per item No 7 but exhaust fan 12” sweep(300 mm) dia complete | 40 | Each | |
90 | 90 | All as per item No 7 but exhaust fan/ fresh air fan 9" (250mm) dia complete. | 10 | Each | |
91 | 91 | All as per item No but Wall fan 12'' /15" (300 mm/350 mm) dia complete | 40 | Each | |
92 | 92 | supply of ball bearing suitable size where required and as directed Make SKF/NBC :- | |||
93 | 93 | (a) 6201ZZ \n\n | 250 | Each | |
94 | 94 | (b) 6202ZZ | 200 | Each | |
95 | 95 | (c) 6203ZZ | 120 | Each | |
96 | 96 | supply of condensor 2.5 MFD where required and directed for ceiling fan | 500 | Each | |
97 | 97 | Supply of condensor 4.00 MFD for exhaust fan where reqd and directed | 80 | Each | |
98 | 98 | Supply of Gun metal bush where required as directed for ceiling fan or exhaust fan all as directed. | 80 | Each | |
99 | 99 | Renewal of shaft suitable for any make of ceiling fans and exhaust fans all as directed. | 20 | Each | |
100 | 100 | Replacement of existing ceiling fan down rod with medium grade galvanized iron/ stove enameled pipe 20mm / 15 mm dia including threading both side or MS conduit heavy duty including both end hole with clamp with rubber real and split pin cable entry hole and check nuts including 3 core copper conductor 23/76, PVC insulated wire complete all as specified and directed | 50 | Running Metre | |
101 | 101 | Supply & Fixing medium step type fan regulator 80 Watt, 240 Volt AC, Gold series "Gold medium step" ISI marked complete in replacement of old unserviceable resistance type regulator all as specified and directed. \nCode No.3111 of make Cona or equivalent in Anchor/SSK/Crabtree as approved by GE. | 50 | Each | |
102 | 102 | M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. \n | 50 | Each \nSet | |
103 | 103 | Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground (Earth pit not less than 2.25 metre below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanised earth strip 32 x 6.00 mm by means of bolts nuts check nuts and protection with 40 mm dia GI Medium grade pipe and washers of galvanised iron or steel, GI strip 7.5 mtr long and plate surrounded with salt charcoal dust etc and 20 mm bore GI light grade pipe for watering, excavation and earth wire including PCC pit in cement concrete 1:3:6 type CI and 40mm thick pit cover of RCC 1:2:4 type 30 reinforced width 8mm dia MS bar @ 150 C/C both ways, furnel wiremesh and testing after completion complete all as specified and directed. | 40 | Each Job | |
104 | 104 | Supply and fixing GI strip 32 x 6 mm for extension of earth and connected to equipment or panel fixed to wall on batten or recess or chases or buried in\nground or drawn in conduit/pipe complete all as specified and directed by Engineer-in-Charge. | 150 | Running Metre | |
105 | 105 | Supply and fixing GI wire 4 mm dia for extension of earth and connected to equipment or DBs incl light grade GI pipe 15 mm fixed to wall on batten\nor recess or chases or buried in ground or drawn in conduit/pipe complete all as specified and directed by Engineer-in-Charge. | 200 | Running Metre | |
106 | 106 | VOLATAGE STABLIZER | |||
107 | 107 | Dismantling of voltage stabilizer 5/4 KVA capacity for repairs and re-fixing back to its original position after repair, cleaning, testing, complete all as directed ( Parts to be replaced will be measured and paid separately under relevant items ). Supply only the following parts for voltage stabilizer 4/5 KVA capacity :- | 10 | Each job | |
108 | 108 | (a) Main printed circuit board | 10 | Each | |
109 | 109 | (b) Auxilary printed board | 10 | Each | |
110 | 110 | (c ) Main transformer | 10 | Each | |
111 | 111 | (d) Auxilary transformer | 8 | Each | |
112 | 112 | (e) High/low cut off relay | 10 | Each | |
113 | 113 | (f) Time delay relay | 7 | Each | |
114 | 114 | (g) Volt meter 0-300 volt range AC round/square shape, | 8 | Each | |
115 | 115 | (h) push button/switch for volt meter. | 9 | Each | |
116 | 116 | (j) Indicator lamp. | 15 | Each | |
117 | 117 | DESERT COOLER :- | |||
118 | 118 | Supply and fixing in replacement of PVC flexible pipe15 mm dia suitable for water distribution system of desert cooler of any size/capacity including elbow and water distributer 3 way as required . | 30 | Running Metre | |
119 | 119 | Supply and fixing of submersible pumps 230 volts, single phase for lifting of water as required head and as directed at site in replacement of old worn out unserviceable vertical pump /submerseable pump. | 10 | Each | |
120 | 120 | Supply and fixing in replacement selector switch suitable for pump and moter control for desert cooler. | 10 | Each | |
121 | 121 | Supply and fixing Kit fan 450 mm sweep, 1400 RPM , 230 Volt AC in replacement of old unserviceable ,worn out Kit fan complete and fixing in desert cooler as directed. Make :- CG, Bajaj, Havells,Usha | 5 | Each | |
122 | 122 | Supply and fixing in replacement of front grill plastic of the desert cooler with necessary nut, bolts, and washer etc, all as directed at site | 5 | Each | |
123 | 123 | Supply and fixing in replacement of loose wood wool padding of desert cooler side shutters in wire net all as directed. | 12 | Kilogram | |
124 | 124 | supply and fixing in replacement side shutter for desert cooler of 22 gauge PGI sheets grill type all as directed. | 15 | Each | |
125 | 125 | Supply and fixing the voltage corrector of 4 KVA with over load and time delay relay with correction from 170 to 250 with out put voltage 230 volts all as rquired and directed suitable for fixing on wall all as directed Make Voline ,logicstat, blue bird or as approved | 4 | Each | |
126 | 126 | M&L for making water tank and body (Except side shutters)for desert cooler with 22 gauge PGI sheet of suitable size including side supports of deert cooler , front panel for fixing of Exhaust/ Kit fan and top cover as per sample and directed including dismantling of old unserviceable water tank and body fitted with old desert cooler. | 5 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail