Military Engineer Services-MES has published Provision Of Central Sewage System (With Mbbr Technology) (Pocket-I) At Leimakhong Mil Stn Under Ge 869 Ews. Submission Date for this Tender is 18-05-2020. Sewerage Construction Tenders in Leimakhong Manipur. Bidders can get complete Tender details and download the document.




Tender Notice

23850709
Corrigendum : Provision Of Central Sewage System (With Mbbr Technology) (Pocket-I) At Leimakhong Mil Stn Under Ge 869 Ews
Open Tender
Indian
Manipur
Leimakhong
18-05-2020

Tender Details

Provision Of Central Sewage System ( With Mbbr Technology ) ( Pocket-I ) At Leimakhong Mil Stn Under Ge 869 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Mar-2020 Corrigendum No 02 Date 25-04-2020
2 18-Apr-2020 Corrigendum No 03 Date 11-05-2020
3 29-Apr-2020 Corrigendum No 04 Financial Bid 11-05-2020
4 11-May-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-05-2020

Key Value

Document Fees
INR 3000 /-
EMD
INR 693000.0 /-
Tender Value
INR 7.36 Crore /-

BOQ Items

NAME OF WORK: PROVN OF CENTRAL SEWAGE SYSTEM (WITH MBBR TECHNOLOGY) (POCKET-I) AT LEIMAKHONG MIL STN UNDER GE 869 EWS
Sl. No. Description of Parts/ Item Item Code / Make No. or Qty. Unit
1 1 Note:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender documents, all drawings & all corrigendum/ amendments and General conditions of contracts before entering / quoting the rates.\n\nLumpsum price worked out by the tenderer for SEWAGE TREATMENT PLANT (B/R WORKS) AND MISC BUILDING WORKS as listed in Schedule ‘A’ Part-I BI01010001010000000000000515BI0100001115 1 Lump-sum
2 2 Lumpsum price workedout by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II. BI01010001010000000000000515BI0100001116 1 Lump-sum
3 3 Lumpsum price workedout by the tenderer for INTERNAL WATER SUPPLY (OPERATOR ROOM) as listed in Schedule ‘A’ Part-III. BI01010001010000000000000515BI0100001117 1 Lump-sum
4 4 Lumpsum price workedout by the tenderer for INTERNAL ELECTRIFICATION (OPERATOR ROOM) as listed in Schedule ‘A’ Part-IV. BI01010001010000000000000515BI0100001118 1 Lump-sum
5 5 Lumpsum price workedout by the tenderer for ROADS & HARDSTANDING as listed in Schedule ‘A’ Part-V. BI01010001010000000000000515BI0100001119 1 Lump-sum
6 6 Lumpsum price workedout by the tenderer for SEWAGE DISPOSAL NETWORK & PROPERTY CONNECTION as listed in Schedule ‘A’ Part-VI. BI01010001010000000000000515BI0100001120 1 Lump-sum
7 7 Lumpsum price workedout by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII. BI01010001010000000000000515BI0100001121 1 Lump-sum
8 8 Lumpsum price workedout by the tenderer for CHAIN LINK FENCING & GATE as listed in Schedule ‘A’ Part-VIII. BI01010001010000000000000515BI0100001122 1 Lump-sum
9 9 Lumpsum price workedout by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX. BI01010001010000000000000515BI0100001123 1 Lump-sum
10 10 Lumpsum price workedout by the tenderer for EXTERNAL ELECTRIFICATION, DG SET & SEWAGE TREATMENT PLANT (E/M WORKS) as listed in Schedule ‘A’ Part-X. BI01010001010000000000000515BI0100001124 1 Lump-sum
11 11 Lumpsum price workedout by the tenderer for SHIFTING / DEMOLITION OF EXISTING UTILITIES (B/R & E/M) & DECOMMISSIONING OF EXISTING SEWERAGE as listed in Schedule ‘A’ Part-XI. BI01010001010000000000000515BI0100001125 1 Lump-sum
12 11.01 SCHEDULE 'A' PART-XII {SEWAGE TREATMENT PLANT (E/M WORKS)} \nNote : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only. BI01010001010000000000000515BI0100001126
13 12 Supply, installation, testing and comissioning of Sewage Treatment Plant of 500 Cum/ day based on principle of aerobic attached growth non cloging randomly Moving Bed Bio Reactor (MBBR) technology for sewage inlet characteristics with parameters given in particular specifications to bring down the clear water at outlet with parameters given in articular specifications. Sludge generation should not exceed more that 04% of the total design flow and should be in digested form so that no further treatment is required. The STP plants and equipment shall be as under: -\n(The work will carried out as per Hydraulic Flow Diagram Drawing and Layout Diagram Drawing , Electrical Schematic Diagram and Hydraulic Schematic Diagram and as per instructions of the manufacturer's :-\n\n(a) Non clog submersible pumps with having flow capacity of 28 Cum / hour at 13 meter head comprising cast iron casing, stainless steel impeller and stainless steel shaft complete directly coupled with electric motor 415 volts, 3 phase, 50 Hz, 3 HP 960 RPM of suitable capacity, IP protection 68 complete all as specified and as directed (for Sewage transfer from Sewage Sump to Bar Screen Chamber) :- 3 working + 01 standby.\n\n(b) Pipe line (from sewage sump to Pump / Bar Screen Chamber) of 100 mm GI medium Class with fittings and control valve / NRV valves as shown in Drawings No. Shillong/SWG/LEI-08 :- 01 Set\n\nContd... BI01010001010000000000000515BI0100001127 1 Each Job
14 12.01 (c) Non clog submersible pumps with having flow capacity of 25 Cum / Hour at 10 M Head, comprising cast iron casing, stainless steel impeller and stainless steel shaft complete directly coupled with Electric motor 415 volts, 3 phase, 50 HZ, 3 HP, 2900 RPM, IP protection 55 alongwith GI (8 Guage sheet) enclosure completely surrounding the pump for protection against rain complete all as specified and as directed (for Sewage transfer from Equilisation tank to Aeration Tank) Quantity : 02 Sets ( 01 Working+ 01 Standby).\n\n(d) Pipe line of 100 mm dia GI medium class at pump suction and 150 mm dia GI medium class at common discharge header from equisation tank upto Aeration Tank 01 & Aeration Tank 2 with and including all fittings and Control Valve / NRV as shown in the drawings -Shillong/SWG/LEI-08 :- 01 Set.\n\n(e) Air Blowers for MBBR having capacity 600 Cum / Hour @ 0.55 Kg / Sqcm coupled with electric motor 3 phase 415 volts, 10 HP, 1000 RPM, IP protection 55 (100 M3/hour for Equilisation Tank Compartment No. 01, 100 m3/hour for Equilisation Tank Compartment No. 02, 200 M3/hour for Aeration Tank Compartment No.01 & 200 M3/hour for Aeration Tank Compartment No. 02) alongwith GI (8 Guage sheet) enclosure completely surrounding the blowers for protection against rain complete all as specified and as directed.\nQunatity : 02 Sets (01 working + 01 Standby)\n\nContd...\n BI01010001010000000000000515BI0100001128
15 12.02 (f) Aeration grid comprising of pipe line 100 mm SS 304 nominal bore with fittings from Air Blower to Aeration Grid in Equilisation Tank No - 01 & Equilisation Tank No 02 (2 Nos) and Aeration Tank No -01 & Aeration Tank No -02 (2 Nos ) with diffusers 100 mm dia as shown in the Drawings No. Shillong/SWG/LEI-08\nQuantity : 01 Lot each.\n\n(g) Moving Bed Bio Reactor (s) with floating plastic media of appropriate density, size and quantity to keep very high MLSS>15000 Mg/Ltr complete all as specified and as directed.\nQuantity : 01 lot\n\n(h) Non Clog Positive Suction Sludge Feed Pumps with self priming centrifugal pump set having flow capacity of 37.5 M3/Hour at 8 meter head, comprising cast iron casing, stainless steel impeller and stainless steel shaft complete directly coupled with electric motor 415 volts, 3 phase, 50 Hz with motor 3 HP, 2900 RPM, 55 IP protection alongwith GI (8 Guage sheet) enclosure completely surrounding the pump for protection against rain complete all as specified and as directed (for sludge transfer from Clarifier Tank to Sludge Holding Tank).\nQuantity : 02 Nos ( 01 Working + 01 Standby)\n\nContd... BI01010001010000000000000515BI0100001129
16 12.03 (j) Pipe line ( from Clarifer tank to Sludge holding Tank ) of 80 mm GI Medium Class with fittings and Control Valves / NRV as shown in the Drawing from Clarifier Tank to Pump and 80 mm GI Medium Class with fittings from Pump to Sludge Holding Tank with Control Valves / NRV as shown in the Drawings No. Shillong/SWG/LEI-08\n\n(k) Pipe line (from Suction Sludge feed pumps to Aeration Tank) of 80 mm GI medium class with fittings and Control Valves / NRV for recirculation of sludge as shown in the Drawings No. Shillong/SWG/LEI-08.\n\n(l) Non clog positive suction Sludge feed pumps with self priming centrifugal pump set having flow capacity of 6 M3 / Hour at 10 meter head, comprising cast iron casing, stainless steel impeller and stainless steel shaft complete directly coupled with electric motor 415 volts, 3 phase, 50 HZ with motor 3 HP, 2900 RPM, 55 IP protection alongwith GI (8 guage sheet) enclosure sorrounding the pump for protection against rain complete all as specified and as directed (for Sludge transfer from Sludge holding tank to Centrifuge). \nQuantity : 02 Nos (01 Working+ 01 Standby)\n\n(m) Pipe line (from Sludge holding Tank to Centrifuge) of 80 mm GI medium class with fittings and Control Valves / NRV from Sludge holding tank to pump and 80 mm GI medium class with fittings from pump to centrifuge with Control Valves / NRV as shown in the Drawings No. Shillong/SWG/LEI-08.\n\nContd...\n BI01010001010000000000000515BI0100001130
17 12.04 (n) Pipe line of 150 mm dia GI medium class from chlorine contact tank to drain out the clear water up to 40 meter complete with Contol Valves all as shown in the Drawings No. Shillong/SWG/LEI-08.\n\n(o) Supply and installation, commissiong and testing of Coagulant Dosing System - 01 Set consisting of the following :-\n(i) Dosing pump electronic with single phase electric motor 19 LPM, 3.5 Kg/Sqcm (01 Working + 01 Standby)\n(ii) Dosing Tank FRP 200 Ltr - 01 No\n(iii) Aggitator with single phase motor -01 No mounted on Dosing Tank.\n(iv) Inlet UPVC of pressure ratiing 10 kgf / m3 of size 15 mm pipe with fittings and control valves from the service tank of operator room and out let pipe line with control valve from dozing system to entry of Clarifier tank - 01 Set.\n(v) Dosing system shall be suitable for comercial alum/polymer.\n(vi) Concentration of chemical in dosing tank to be mentioned.\n\nContd... BI01010001010000000000000515BI0100001131
18 12.05 (p) Supply and installation, commissiong and testing of Chlorine Dosing System - 01 Set. (Sodium hypo Chloride ) consisting of the following :-\n(i) Dosing pump electronic with single phase electric motor 19 LPM, 3.5 Kg/Sqcm (01 Working + 01 Standby)\n(ii) Dosing Tank FRP 200 Ltr - 01 No\n(iii) Aggitator with single phase motor - 01 No mounted on Dosing Tank.\n(iv) Inlet pipe line UPVC 15 mm with fittings and control valves from the service tank of operator room and out let pipe line with control valve from dozing system to entry of Chlorine Contact Tank - 01 Set\n(v) Dosing system suitable for sodium hypo chloride in granular form\n(vi) Concentration of chemical in dosing tank to be mentioned.\nNote :-(aa) Consumption of Sodium Hypo Chloride per/Hour to be mentioned.\n\n(q) Supply, installation, testing and commissioning of Decanter Centrifuge, Screw Type with motor Bowl Dia 23" and Bowl material AISI 316 with 3 Phase motor of capacity 7.5 kW, 10 HP with all other parts in contact with sludge made of AISI 316 material complete all as per manufacturers instruction, with and including supply and laying/fixing of pipe line of 150mm dia GI medium class with fittings and Contol Valves/NRV from Dewatering Centrifuge to Equilisation tank complete with all as shown in drawings and as directed.\nQuantity of Centrifuge - 01 No.\n\nContd... BI01010001010000000000000515BI0100001132
19 12.06 (r) Supply, installation, testing and commissioning of factory made powder coated (CPRI approved) indoor type, dust & vermin proof, IP-44 LT feeder pillar box made out of 2 mm CRCA steel sheet of suitable size and angle iron 40 mm x 40mm x 6 mm , powder coated over one coat of red oxide primer suitably grouted in PCC (1:3:6) using 20 mm graded stone aggregate including bus bar, internal wiring with PVC insulated single core cables of copper conductor of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type locking arrangement and slanted roof. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 4 wire system, 50 Hz supply system. The panel board shall comprise of following items & all specified in SSR Part-I clause no 19.21 and all as shown on drawing .\n(A) INCOMING:-\n(i) MCCB 100 amps, 4 pole, breaking capacity 25 KA suitable for operation of 415 volts AC 50 HZ - 01 No\n(ii) 4 strip aluminum coated copper bus bar of rating 1.5 times current carrying capacity of incoming switch gear.\n(iii) Digital voltmeter, three phase, Cl-1, 0-500V with selector switch - 01 No \n(iv) Digital ammeter, three phase, Cl-1, 0-100A with CTs & selector switch - 01 No\n(v) Phase indicator lamp R-Y-B, neon type (Set of Three)- 01 Set \n\nContd... BI01010001010000000000000515BI0100001133
20 12.07 (B) OUTGOING :-\n(i) MCCB 3 pole 16 Amps , 16 KA ,415 Volts - 04 No (for Sewage transfer pump of Sewage Sump to Bar screen Chamber)\n(ii) DOL starter with push button arrangement of capcity 3 HP - 04 Nos (for Sewage transfer pump of Sewage Sump to Bar screen Chamber)\n(iii) Digital Ammeter, three phase, Cl-1, 0-30 Amps with CTs and selector switch - 04 Nos (for Sewage transfer pump of Sewage Sump to Bar screen Chamber)\n(iv) MCCB 3 pole 16 Amps, 16 KA, 415 Volts - 02 No (for Sewage transfer from Equilisation tank to Aeration Tank)\n(v) DOL starter with push button arrangement of capacity 3 HP with level sensor and level switch - 02 Nos (for Sewage transfer from Equilisation tank to Aeration Tank)\n(vi) Digital Ammeter three phase, Cl-1, 0-30 Amps with CTs and selector switch - 02 Nos (for Sewage transfer from Equilisation tank to Aeration Tank)\n(vii) MCCB 3 pole 16 Amps , 16 KA ,415 Volts - 02 Nos (for Sludge transfer pump From Clarifier tank to Sludge holding tank)\n(viii) DOL starter with push button arangement of capacity 3 HP with level sensor and level switch - 02 Nos (for Sludge transfer pump From Clarifier tank to Sludge holding tank)\n(ix) Digital Ammeter, three phase, Cl-1, 0-30 Amps with CTs and selector switch - 02 Nos (for Sludge transfer pump From Clarifier tank to Sludge holding tank)\n\nContd... BI01010001010000000000000515BI0100001134
21 12.08 (x) MCCB 3 pole 16 Amps, 16 KA ,415 Volts - 02 Nos (for Sludge transfer pump From Sludge holding tank to Centrifuge)\n(xi) DOL starter with push button arangement of capacity 3 HP with level sensor and level switch - 02 Nos (for Sludge transfer pump From Sludge holding tank to Centrifuge)\n(xii) Digital Ammeter, three phase, Cl-1, 0-30 Amps with CTs and selector switch - 02 Nos (for Sludge transfer pump From Sludge holding tank to Centrifuge)\n(xiii) MCCB 3 pole 16 Amps , 16 KA , 415 Volts -01 No (for Centrifuge)\n(xiv) FASD starter 01 No of capacity 10 HP (for Centrifuge) \n(xv) Digital Ammeter, three phase, Cl-1, 0-30 Amps with CTs and selector switch - 01 No (for Centrifuge)\n(xvi) MCCB 3 pole 16 Amps , 16 KA ,415 Volts -02 No (for Blower Pump )\n(xvii) Soft Starter 02 Nos of capacity 10 HP with push button arrangement (for air blower)\n(xviii) Digital Ammeter, three phase, Cl-1, 0-30 Amps with CTs and selector switch - 02 Nos (for for Blower Pump)\n(xix) MCB DP 10 Amps, 10 KA, 230 Volts - 04 Nos (for Alum Dozer)\n(xx) MCB DP 10 Amps, 10 KA, 230 Volts - 04 Nos (for Chlorine Dozer)\n(xxi) MCB DP 10 Amps, 10 KA, 230 Volts -04 Nos (spare)\nNote :-\n(aa) All starter shall have provn of overload protection, under voltage relay, time delay and single phase protection. \n\nContd... BI01010001010000000000000515BI0100001135
22 12.09 (s) Flow measuring devices/ instrumentation for operation and proper process of Sewage Treatment, protection of the equipments with necessary sensors and control wiring linked with starters shall be provided as per manufacturer recommendation and cost of the same deemed to be included in the quoted rate by the contractor. \n\n(t) Supplying, laying & testing of LT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, heavy duty electric power cable, 1100 volt grade, ISI marked with multi-stranded copper conductor of cross sectional area 10 Sqmm x 3 core from master control panel to various equipment of STP complete all as specified and as directed.\n\n(u) Supplying, laying & testing of LT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, heavy duty electric power cable, 1100 volt grade, ISI marked with multi-stranded copper conductor of cross sectional area 4 Sqmm x 2 core from master control panel to various equipment of STP complete all as specified and as directed.\n\n(v) PCC 1:3:6, Tyep C-2 in foundation and mounting arrangement for pumps, blowers and other equipments as recommended by OEM of STP - 01 Set. BI01010001010000000000000515BI0100001136
23 12.1 Subtotal of Schedule "A' Part-XII BI01010001010000000000000515BI0100001137
24 12.11 SCHEDULE 'A' PART-XIII (ONSITE SANITATION FOR MH & BUTCHERY)\nNote : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only. BI01010001010000000000000515BI0100001138
25 13 Construction of RCC SEPTIC TANK 150 USERS CAPACITY with all fittings and fixtures complete all as specified and shown on Drawings No. CESZ/2019/STD-03, Sheet No. 1/1.\n\n BI01010001010000000000000515BI0100001139 1 Each Job
26 14 Construction of Brick Masonry SOAK WELL, 3.00 meter Dia x 3.00 meter effective Depth with all fittings and fixtures complete all as specified and shown on Drawings No. TD/SZ/502, Sheet No. 1/1. BI01010001010000000000000515BI0100001140 2 Each Job
27 15 Construction of Oil & Grease Trap at the inlet chamber at Military Hospital and Military Transport complete all as specified and shown on Drawing No. CESZ/2019/STD-04, Sheet No 1/1. BI01010001010000000000000515BI0100001141 2 Each Job
28 15.01 Subtotal of Schedule "A' Part-XIII BI01010001010000000000000515BI0100001142
29 15.02 SCHEDULE 'A' PART-XIV (MISC B/R, E/M SERVICES) \nNote : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only. BI01010001010000000000000515BI0100001143
30 16 Supply, laying and testing of 150 mm inner diameter of double wall corrugated (DWC) high density polyethylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked (with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS-16098 (Part-2) : 2013 and as per manufacturer's instructions complete all as specified and as directed.\nMake :- Rex Polyextrusion Pvt Ltd/Jain Irriogation Systems Ltd/ Alom Poly Extrusions Limited / The Supreme Industries Ltd.\nNote:- Bedding of pipe shall not be provide in normal condition and CONSTRUCTION METHODS shall be strictly compiled as per clause no A-4 of ANNEX 'A' of IS 16098 (Part-2) : 2013. BI01010001010000000000000515BI0100001144 4300 RM
31 17 Supply, laying and testing of 200 mm inner diameter of double wall corrugated (DWC) high density polyethylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked (with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS-16098 (Part-2) : 2013 and as per manufacturer's instructions complete all as specified and as directed.\nMake :- Rex Polyextrusion Pvt Ltd/Jain Irriogation Systems Ltd/ Alom Poly Extrusions Limited / The Supreme Industries Ltd.\nNote:- Bedding of pipe shall not be provide in normal condition and CONSTRUCTION METHODS shall be strictly compiled as per clause no A-4 of ANNEX 'A' of IS 16098 (Part-2) : 2013. BI01010001010000000000000515BI0100001145 810 RM
32 18 Supply, laying and testing of 250 mm inner diameter of double wall corrugated (DWC) high density polyethylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked (with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS-16098 (Part-2) : 2013 and as per manufacturer's instructions complete all as specified and as directed.\nMake :- Rex Polyextrusion Pvt Ltd/Jain Irriogation Systems Ltd/ Alom Poly Extrusions Limited / The Supreme Industries Ltd.\nNote:- Bedding of pipe shall not be provide in normal condition and CONSTRUCTION METHODS shall be strictly compiled as per clause no A-4 of ANNEX 'A' of IS 16098 (Part-2) : 2013. BI01010001010000000000000515BI0100001146 210 RM
33 19 Supply, laying and testing of 300 mm inner diameter of double wall corrugated (DWC) high density polyethylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked (with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS-16098 (Part-2) : 2013 and as per manufacturer's instructions complete all as specified and as directed.\nMake :- Rex Polyextrusion Pvt Ltd/Jain Irriogation Systems Ltd/ Alom Poly Extrusions Limited / The Supreme Industries Ltd.\nNote:- Bedding of pipe shall not be provide in normal condition and CONSTRUCTION METHODS shall be strictly compiled as per clause no A-4 of ANNEX 'A' of IS 16098 (Part-2) : 2013. BI01010001010000000000000515BI0100001147 45 RM
34 20 Supply, laying and jointing of ductile iron pipes with spigot and socket ends suitable for push on rubber joint centrifugally cast, class (K-9) , inner side cement lining and outer side black bitumen coating and any length, laid in trenches of 100 mm bore pipe and including push on rubber (EPDM) ring with ISI marked complete all as specified and as directed. BI01010001010000000000000515BI0100001148 100 RM
35 21 Supply, laying and jointing of ductile iron pipes with spigot and socket ends suitable for push on rubber joint centrifugally cast, class (K-9) , inner side cement lining and outer side black bitumen coating and any length, laid in trenches of 150 mm bore pipe and including push on rubber (EPDM) ring with ISI marked complete all as specified and as directed. BI01010001010000000000000515BI0100001149 100 RM
36 22 Supply, laying and jointing of ductile iron pipes with spigot and socket ends suitable for push on rubber joint centrifugally cast, class (K-9) , inner side cement lining and outer side black bitumen coating and any length, laid in trenches of 200 mm bore pipe and including push on rubber (EPDM) ring with ISI marked complete all as specified and as directed. BI01010001010000000000000515BI0100001150 75 RM
37 23 Supply & fixing of ductile iron pipe fittings / special sutable for flange, spigot & socket ductile pipe class (K-9) upto 200 mm dia complete all as specified and directed.\n BI01010001010000000000000515BI0100001151 185 Kg
38 24 Joint (push on) with rubber or fibre board gasket having two different hardness for DI pipe spigot and socket ends and fittings of size varies from 100 mm to 200 bore pipe complete all as specified and as directed. BI01010001010000000000000515BI0100001152 22 Each
39 25 Run lead joints to DI pipes and fittings for 100 mm to 200 mm bore DI pipe complete all as directed. BI01010001010000000000000515BI0100001153 3 Each
40 26 Dismantling and taking out old steel poles/struts, any size and any location including all accessories, etc. complete all as directed. BI01010001010000000000000515BI0100001154 5 Each
41 27 Dismantling and taking up unserviceable cable from trenches of any size and grade complete as directed.\nNote:-\n(i) Earthwork will be measured and paid under respective items.\n BI01010001010000000000000515BI0100001155 150 RM
42 28 Suppling & Fixing Pre-cast RCC post HT cable route indicator made up of RCC (1:1.5:3), Type A-1 of size 1200 mm long, 150 mm x 150 mm cross section at bottom tapered to cross section 100 mm x 100 mm at top duly reinforced with 4 nos 10 mm dia TMT bar on vertical and 8 mm TMT stirrups at 150c/c incl binding wire and embossing "MES HT CABLE" on all four sides and fixed at cable trench during returning filling of soil keeping 400mm above ground complete all as specified and as directed. BI01010001010000000000000515BI0100001156 18 Each
43 29 Supply and fixing SMC pole mounted right hinged looping box of size 300 mm x 200 mm x 105 mm with MCB 6 amps to 10 amps capacity, aluminium bus bar - 04 Nos fixed on ebonite insulator suitable capacity for 3 phase and neutral complete with necessary MS clamp made of 25 mm x 3 mm MS flat, bolts, nuts, washers, etc. for fixing on pole complete all as directed. BI01010001010000000000000515BI0100001157 10 Each Job
44 30 Supply and fixing FRP Junction Box (weather proof) of size 240 mm x 130 mm x 110 mm, three phase and neutral alongwith suitable clamps including MCB 25 Amps 10 KA rating fixing with flat iron clamps of size 25 mm x 3 mm, nuts, bolts, washers, etc. complete all as directed. BI01010001010000000000000515BI0100001158 4 Each Job
45 31 Supply and fixing weather proof flat twin core cable with aluminium stranded conductor 2.5 Sqmm 1100 volts grade from pole junction box to street light fitting including PVC conduit 20 mm dia medium grade for protedtion of cable from junction box to bracket fixed with suitable size GI clamps at 1 meter spacing including connection complete all as directed. BI01010001010000000000000515BI0100001159 120 RM
46 32 Supply and fixing ceiling fan energy saving and fancy type 1200 mm(minimum) sweep three blade, 5 star BEE rating without regulator including clamp set, hanging rod and necessary connecting PVC insulated Flexible cable of size 0.75 sqmm copper conductor for connection from ceiling rose to fan and connecting complete all as specified and as directed.\nMake: Model- ES-50 Premium of Havells or equivalent make as per Appendix 'B'. BI01010001010000000000000515BI0100001160 2 Each
47 33 S & F Blanking plate for MCB DBs of suitable size complete all as specified complete all as specified and as directed. BI01010001010000000000000515BI0100001161 2 Each
48 34 S&F LED New Adore 10W B22 WW lamp complete all as specified. BI01010001010000000000000515BI0100001162 18 Each
49 35 Supply and fixing of LED batten surface/ceiling mounting box type light fitting 22 Watt, drive and made of epoxy powder coated extruded aluminium channel housing with high quality polycarbonate opal diffuser cover including & high power LED’s as light source with LED fitting system lumen efficiency not less than 95% Lumen per watt and electronic driver( >80% efficiency level & THD< 10%) , power factor shall be >0.95 complete and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up with twin core 0.75 sq. mm copper conductor flexible wire/cable complete all as specified.\n BI01010001010000000000000515BI0100001163 7 Each
50 36 Supply and fixing of Energy saving LED light fitting 20 Watt, 230 volts, surface/ceiling mounting(suspended from ceiling) with electronic driver and made of integrated sleek extruded polycarbonate channel with white acrylic cover & high power LED’s as light source with LED fitting system lumen not less than 95% Lumen per watt and electronic driver( >80% efficiency level & THD< 10%) , power factor shall be >0.95 complete and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up with twin core 0.75 sq. mm copper conductor flexible wire/cable complete all as specified. BI01010001010000000000000515BI0100001164 7 Each
51 37 Supply , Fixing & testing of LED street light fitting (Building Security light) of 25 Watt, driver and made of pressure die-cast aluminum housing with epoxy power coated dark graphite grey colour finish and prismatic polycarbonate cover with individual lenses IP 65 & high power LED’s as light source with LED fitting system lumen efficiency not less than 95% Lumen per watt and electronic driver with efficiency > 85% with inbuilt protection against lightning, over voltage, short circuit and surge/spike protection upto 5 KV ensuring longer life (THD <10%, PF shall be > 0.95, colour temperature 5700±300 K), Life expectancy of LED's minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than three years. The fitting shall be tested LM 79 & 80 and test certificate shall be submitted from original manufacture. The light fitting shall be fixed on pole with and including 25 mm dia( or higher size as per manufacturers recommendation) light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket 1.5 mtr long complete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed. BI01010001010000000000000515BI0100001165 4 Each
52 38 Supply , Fixing & testing of LED street light fitting of 45 Watt, driver and made of pressure die-cast aluminum housing with epoxy power coated dark graphite grey colour finish and prismatic polycarbonate cover with individual lenses IP 65 & high power LED’s as light source with LED fitting system lumen efficiency not less than 95% Lumen per watt and electronic driver with efficiency > 85% with inbuilt protection against lightning, over voltage, short circuit and surge/spike protection upto 5 KV ensuring longer life (THD <10%, PF shall be > 0.95, colour temperature 5700±300 K), Life expectancy of LED's minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than three years. The fitting shall be tested LM 79 & 80 and test certificate shall be submitted from original manufacture. The light fitting shall be fixed on pole with and including 40 mm dia( or higher size as per manufacturers recommendation) light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket 1.5 mtr long complete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed.\n BI01010001010000000000000515BI0100001166 10 Each
53 39 Supply , Fixing & testing of LED street light fitting of 70-72 Watt, driver and made of pressure die-cast aluminum housing with epoxy power coated dark graphite grey colour finish and prismatic polycarbonate cover with individual lenses IP 65 & high power LED’s as light source with LED fitting system lumen efficiency not less than 95% Lumen per watt and electronic driver with efficiency > 85% with inbuilt protection against lightning, over voltage, short circuit and surge/spike protection upto 5 KV ensuring longer life (THD <10%, PF shall be > 0.95, colour temperature 5700±300 K), Life expectancy of LED's minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than three years. The fitting shall be tested LM 79 & 80 and test certificate shall be submitted from original manufacture. The light fitting shall be fixed on pole with and including 40 mm dia( or higher size as per manufacturers recommendation) light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket 1.5 mtr long complete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed.\nMake : Model No 169698 BRTFG 72W LED I of BAJAJ / LHETBXU7PA6J070 of Havells / LSRT01S072XC of Jaquar or equivalent model of make list as given in Appdix "B".\n\nNote :- For items No. 35.00 to 39.00 : Warranty of complete LED luminaries fitting shall not less than three years and Life expectancy of LED's minimum 50,000 burning hrs.\n BI01010001010000000000000515BI0100001167 4 Each
54 40 Supply, installation, testing and commissioning of silent type Diesel Engine driven Generating set (engine as per IS: 10001/10002 and alternator as per IS: 13364) of capacity 40 KVA, 415 volts +/- 5% AC, 3 phase 4 wire, 50 Hz at 0.8 PF (lagging) at 1500 RPM complete with RCC foundation, Control panel with necessary protection & meters including sound proof canopy , including the following: -\n(A) ENGINE:-Engine shall be multicylinder four stroke (40 KVA), Radiator water / coolant turbo charged with electronic governor with the following: - (i) Fuel level indicator, (ii) Fuel tank of capacity as per manufacturers' recommendation, (iii) Fuel inlet arrangement from outside the acoustic enclosure with locking arrangement, (iv) Exhaust manifold and residential type silencer, (v) Continuous 10% overload capacity in every 12 Hrs running, (vi) Self starting with and including 24 V maintenance free battery including charging circuit, (vii) Radiator with first fill of coolant, (viii) Turbocharger with continuous duty rating, (ix) First fill of lub oil, (x) Coolant temp gauge, Lub oil, pressure gauge,Tacho-cum-hour meter, (xi) Engine spare parts list and maintenance manual- 03 copies\n(B) ALTERNATOR:-40 KVA / 32 KW at 0.8 PF(Iag), 415 volt, 3 phase, 4 wire, 50 Hz, 1500 RPM copper wound with (i) self regulated brushless self excitation & (ii) automatic voltage regulator with band of voltage regulation + 2.5% of rated voltage.\n(C) BASE FRAME: -(i) Sturdy robust MS frame duly bolted, coupled, aligned, tested and housed within acoustic enclosure with anti-vibration pad.\n BI01010001010000000000000515BI0100001168 1 Each Job
55 40.01 (D) ACOUSTIC ENCLOSURE:-It should be compact, modular construction and approved by ARAI (nodal agency of CPCB) with the following:-\n(i) Overall noise level less than 75 dB measured at 1 mtr distance in free field condition, \n(ii) Inside illumination shall be suitable light as per manufacturers' design. \n(E) CONTROL PANEL :- Factory fabricated free standing of suitable size copper bus bar with and including (i) MCCB 4 pole, 415 Volt, 16 KA, 3 phase of suitable capacity as per OEM, (ii) internal wiring with suitable size copper conductor, (iii) Start and Stop push button, (iv) Digital voltmeter with selector switch, (v) Digital frequency meter, (vi) Digital ammeter with 3 Nos CT and selector switch, (vii) Digital power factor meter, (viii) Three phase energy meter, (ix) Tripping arrangement with hooter for 'High engine temp', 'Low lub oil pressure', 'High lub oil temp', Low and high engine speed' etc as per manufacturers' design.\nNote: - 1. Necessary foundation for installing the DG Set and any other accessories shall be provide as per manufacturers' recommendation and cost of the same deemed to be included in the quoted rate\n2. Cost of testing including arrangement of artificial load upto 125% of rated capacity, temporary arrangement of connecting cables, decibel meter and cost of fuel & testing material shall deemed to be included in the quoted rate. BI01010001010000000000000515BI0100001169
56 40.02 Subtotal of Schedule "A' Part-XIV BI01010001010000000000000515BI0100001170
57 41 Lumpsum price worked out by the tenderer for Provisional sum of ` 87,600/- for following items including of earth work, concrete work, steel section etc. complete all as directed.\n(i) Steel gate 5.50 m wide & 2.10 m height with RCC pillar : 02 Nos\n\nNote:- \n(i) Contactor shall quote, contractors percentage (amount) plus/minus the pre-prices amount.\n(ii) The works under provisionl sum shall be executed wholly or in part and to the extent and specifications as order by the GE in writting. The work shall be measured and paid as applicable rates in MES Schedule Part-II (2010) adjusted by the contractor's percentage quoted by the tenderer for provisional sum. The items not available in MES Schedule shall be priced in terms of condition 62(G) of IAFW - 2249 and in that case percentage quoted by the contractor shall not be applicable for that particular items.\n\n\n BI01010001010000000000000515BI0100001171 1 Pro-visional Lumpsum
58 42 SCHEDULE 'A' PART-XV {MANNING & OPERATIONS FOR STP OF CAPACITY 0.50 MLD (MBBR)} (PHASE-II)\n\nNote : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only. BI01010001010000000000000515BI0100001172
59 42.01 Comprehensive Maintenance and Operation of Sewage Treatment Plant of Capacity 0.50 MLD using MBBR technology & DG Set installed under this project during the first year including all connected consumables materials round the clock (24 Hrs in 3 shifts of 08 Hrs Each) complete all as required & directed by Engr-in-Charge commencing from the next date of completion of Phase-I providing requisite manpower all as per OEM's recommendation each shift as under:- \n(i) Operator (category w.r.t. minimum wages - skilled labour) - One No\n(ii) Helper (category w.r.t. minimum wages - un-skilled labour) - One No\n\nNote:- \n(a) The scope of work shall include day to day running maintenance, cleaning of the plant and repairing if any, complaints from the concerned plant and cost of the same shall deemed to be included in the quoted rate. \n(b) Necessary reliever shall have to be provided during "week off day" of the regular Operator/Helper without any extra cost. Duty register shall be maintained accordingly duly approved by Engr-in-Charge. \n(c) Water and Electricity required for operation of STP plant shall be provided free of cost by the department.\n(d) Timings of shifts of 08 hrs each shall be decided by GE & this aspect shall be deemed to be included in the rates quoted by the bidders. \n(e) Contractor shall also be responsible for the discipline & integrity of staff deployed & shall be responsible for any lapse. \n(f) Plant shall be handed over in fully serviceable state after completion of contract.\n(g) Comprehensive maint of all the items shall be done as per manufacturer's instruction/manual.\n(h) Sufficient consumables materials shall be kept at site by the contractor to avoid disruption of services and the cost for the same shall be borne by the contractor..\n(j) Maintenance of bldgs is not under the scope of this item.\n(k) The defect liability of Phase-I is 24 Months. Hence the rates are deemed to be quoted for repairs within & beyond the period of defect liability accordingly.\n BI01010001010000000000000515BI0100001173 11 Each Month
60 42.02 Ditto all as per Sl Item No 42.01 here-in-before but for the period commencing from the next day after completion of Item No. 42.01 above. BI01010001010000000000000515BI0100001174 11 Each Month
61 42.03 Ditto all as per Sl Item No 42.01 here-in-before but for the period commencing from the next day after completion of Item No. 42.02 above. BI01010001010000000000000515BI0100001175 11 Each Month
62 42.04 Ditto all as per Sl Item No 42.01 here-in-before but for the period commencing from the next day after completion of Item No. 42.03 above. BI01010001010000000000000515BI0100001176 11 Each Month
63 42.05 Ditto all as per Sl Item No 42.01 here-in-before but for the period commencing from the next day after completion of Item No. 42.04 above. BI01010001010000000000000515BI0100001177 11 Each Month
64 42.06 Subtotal of Schedule "A' Part-XV BI01010001010000000000000515BI0100001178
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail