Military Engineer Services-MES has published Special Repair To External Electric Power Supply Line At Shillong Cantt Under Ge Shillong. Submission Date for this Tender is 11-05-2020. Electrification Work Tenders in GE SHILLONG Meghalaya. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 27-Mar-2020 | Revised date | Date | 20-04-2020 |
2 | 20-Apr-2020 | revised date2 | Date | 28-04-2020 |
3 | 29-Apr-2020 | Revised date3 | Date | 11-05-2020 |
Name of Work: SPECIAL REPAIR TO EXTERNAL ELECTRIC POWER SUPPLY LINE AT SHILLONG CANTT UNDER GE SHILLONG | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Dismantling and removing existing OH line, ACSR conductor any size or any type from poles/structures etc complete all as specified and directed by Engr-in-Charge. | 3 | Qtl | |
2 | 2 | Dismantling and removing cross-arms of M.S. channel or angle sections etc. complete any size or any type complete all as specified and directed by Engr-in-Charge. | 2 | Qtl | |
3 | 3 | Dismantling and removing insulators of any size or any type complete all as specified and directed by Engr-in-Charge. | 52 | Each | |
4 | 4 | Excavation in trenches not exceeding 1.50 m wide and not exceeding. 1.5 m in depth for foundation, etc, or for shaft, wells, cesspits, manholes, pier holes, etc. not exceeding. 10 sqm on plan and getting out in hard/dense soil complete all as specified and as directed. | 900 | Cum | |
5 | 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and directed | 220 | Cum | |
6 | 6 | Removing surplus excavated materials (soils) up to a distance not exc. 50m and depositing where directed at a level not exceeding. 1.5m above the starting point complete all as specified and directed. | 680 | Cum | |
7 | 7 | Supply and spread sand in trenches as sand cushioning to underground cable for protection with fine river sand and provide required cover after punning down complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.) | 220 | Cum | |
8 | 8 | M & L for brick protection cover to LT underground cables with sub class ‘B’ over burnt brick, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and directed. | 23.3 | Per 1000 | |
9 | 9 | S&F XLPE insulated screened PVC bedded, galvanized steel strip of wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core complete all as specified and directed. | 141 | RM | |
10 | 10 | S&F XLPE insulated screened PVC bedded, galvanized steel strip of wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core complete all as specified and directed. | 300 | RM | |
11 | 11 | S&F XLPE insulated screened PVC bedded, galvanized steel strip of wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed. | 320 | RM | |
12 | 12 | S&F XLPE insulated screened PVC bedded, galvanized steel strip of wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed. | 170 | RM | |
13 | 13 | S&F XLPE insulated screened PVC bedded, galvanized steel strip of wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed. | 350 | RM | |
14 | 14 | S&F XLPE insulated screened PVC bedded, galvanized steel strip of wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed. | 604 | RM | |
15 | 15 | S&F XLPE insulated screened PVC bedded, galvanized steel strip of wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed. | 950 | RM | |
16 | 16 | S&F XLPE insulated screened PVC bedded, galvanized steel strip of wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and directed. | 390 | RM | |
17 | 17 | M & L for cutting existing bituminous road surfaces ( minimum width 20 cm and depth 30 cm) for laying of pipe/cable and making good with 150 mm thick PCC 1:3:6 any type C1 20 mm graded aggregate over 100 mm thick hardcore/moorum and match with the adjacent surface after laying of pipe/cable complete all as directed and specified. | 24 | RM | |
18 | 18 | Supply, laying and connecting GI tubing, light grade,100mm bore with all fittings for protection of cable /on pole including necessary clamps nut bolts etc complete all as specified and directed. | 24 | RM | |
19 | 19 | Supply, laying and connecting GI tubing, light grade,50mm bore with all fittings for protection of cable /on pole including necessary clamps nut bolts etc complete all as specified and directed. | 18 | RM | |
20 | 20 | Supply, laying and connecting GI tubing, light grade,40mm bore with all fittings for protection of cable /on pole including necessary clamps nut bolts etc complete all as specified and directed. | 64 | RM | |
21 | 21 | M&L for PCC 1:2:4 type B-1 (Using 20 mm graded stone aggregate) as in coping/benching including weathering slightly chamfered on edge and finishing exposed surfaces even and smooth without using extra cement including necessary formwork and dismantling of old coping complete all as specified and directed . | 1 | Cum | |
22 | 22 | Supply, install , testing and commissioning of outdoor LT distribution feeder pillar IP-65 , CPRI approved of suitable size factory made totally enclosed, dust and vermin proof , double leaf shutter in front and single leaf shutter in rear made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and painted and aluminium bus bar 200 amps, 415 volts, 50 Hz 3 phase and 4 wire system with the following items connected as under including supplying and fixing on MS chanel 75mmx40mmx5mm and fixing the feeder pillar in necessary earthwork and PCC (1:2:4) foundation including PCC (1:2:4) work around the panel board within 60CM from panel all around- (Near Cottage no - 3 & 6) :- INCOMING (a) MCCB 4 pole 250 Amps, 415 V, 35 KA-01 No \n(b) LCD multifunctioning meter-01 No\n(c) Phase indicator Lamps (RYB phases)-01 Set (Set of Three) LED Cluster type\n(d) CTs 100/5 amps-set of three \n(e) Aluminium bus bar 300 Amps-03 Nos and 150 Amps -01 No\n(f) Internal Wiring for panel including insulators, sleeves etc\nOUTGOING\n(a) MCCB 4 pole 63 Amps, 415 V, 25 KA-06 Nos\n(b) MCCB 4 Pole 100 Amps, 415 V, 25 KA-02 Nos\n\n | 2 | Each Job | |
23 | 23 | Supply, install , testing and commissioning of outdoor LT distribution feeder pillar IP-65 , CPRI approved of suitable size factory made totally enclosed, dust and vermin proof , double leaf shutter in front and single leaf shutter in rear made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and painted and aluminium bus bar 200 amps, 415 volts, 50 Hz 3 phase and 4 wire system with the following items connected as under including supplying and fixing on MS chanel 75mmx40mmx5mm and fixing the feeder pillar in necessary earthwork and PCC (1:2:4) foundation including PCC (1:2:4) work around the panel board within 60CM from panel all around (Near Cottage no - NCC Officer mess & Stn Cell)\nINCOMING (a) MCCB 4 pole 200 Amps, 415 V, 35 KA-01 No \n(b) LCD multifunctioning meter-01 No\n(c) Phase indicator Lamps (RYB phases)-01 Set (Set of Three) LED Cluster type\n(d) CTs 100/5 amps-set of three \n(e) Aluminium bus bar 300 Amps-03 Nos and 150 Amps -01 No\n(f) Internal Wiring for panel including insulators, sleeves etc\nOUTGOING\n(a) MCCB 4 pole 160 Amps, 415 V, 25 KA-03 Nos\n(b) Space for MCCB 4 Pole 100 Amps, 415 V, 25 KA-03 Nos | 2 | Each Job | |
24 | 24 | Supply, install , testing and commissioning of outdoor LT distribution feeder pillar IP-65 , CPRI approved of suitable size factory made totally enclosed, dust and vermin proof , double leaf shutter in front and single leaf shutter in rear made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and painted and aluminium bus bar 200 amps, 415 volts, 50 Hz 3 phase and 4 wire system with the following items connected as under including supplying and fixing on MS chanel 75mmx40mmx5mm and fixing the feeder pillar in necessary earthwork and PCC (1:2:4) foundation including PCC (1:2:4) work around the panel board within 60 cm from panel all around (Near Cottage no -RTG) INCOMING (a) MCCB 4 pole 160 Amps, 415 V, 35 KA-01 No \n(b) LCD multifunctioning meter-01 No\n(c) Phase indicator Lamps (RYB phases)-01 Set (Set of Three) LED Cluster type\n(d) CTs 100/5 amps-set of three \n(e) Aluminium bus bar 300 Amps-03 Nos and 150 Amps -01 No\n(f) Internal Wiring for panel including insulators, sleeves etc\nOUTGOING\n(a) MCCB 4 pole 100 Amps, 415 V, 25 KA-03 Nos\n(b) MCCB 4 Pole 63 Amps, 415 V, 25 KA-03 Nos\n | 1 | Each Job | |
25 | 25 | Supply and fix new Sheet Metal enclosers of 90cm x60cmx35 cm size for housing including high conductivity aluminium bus bars of capacity 200 Amps - 04 Nos mounted on epoxy insulator ,fabricated from 3 mm thick CRCA sheet with front hinged type door and locking arrangement and , fixed with four nos lugs angle iron of size 25 mmX 25 mm X 3 mm thick , 100 CM long embedded in PCC 1:2:4 , type B1 in ground complete ,including applying two coats of synthetic enamel paint over one coat of red oxide primer and fixed including connecting cables of suitable size lugs and testing suitable for three phase energy meter and DB VT TPN 4 Way complete all as specified and as directed. NOTE :- Rate quoted shall be deemed to be inclusive of PCC, excavation and earth work.. | 5 | Each Job | |
26 | 26 | Supply & fixing factory made IP-65 (Dust and power jet proof according to IEC60529) transparent street light junction box of size 167 X 125 x 82mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant , fire retardant having high impact (IK 08) totally insulated, UV resistant ) having high grade gasket made of polyurethane with two cable gland for cable size 10 sqmm etc and fixing on pole with MS flat iron of size 20X3mm with necessary nut & bolts complete including taking down old one all as specified and directed Make:Hensel Cat No K9105 or equivalent in Sintex | 50 | Each | |
27 | 27 | Supply and fix in repairs MCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with and including one No MCCB 100 Amps 4 Pole 25 KA as incomer and copper thimble for connection of cable complete all as specified. . | 5 | Each | |
28 | 28 | Supply & fix AC single phase static energy meter of accuracy class 1.0, 240 V 50 Hz with Backlit LCD display of rating 10 - 60 A (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box complete all as specified and directed. Make : L & T, HPL, Schneider, BCH | 5 | Each | |
29 | 29 | Supply and fixing Timer DB 40 Amps with astronomical digital time switch and connector , IP 54 degree protection 440 Volts complete all as specified and directed. Make- Indo Asian cat no TL032DB0 or equivalent make of L & T /Havells | 1 | Each | |
30 | 30 | Supply and fixing three single core multi stranded copper conductor cable of size 2.5 sqmm FRLSH for phase neutral and earth continually drawn through minimum 20 mm dia medium grade PVC conduit pipe including clamp etc and connection complete including taking down old one all as specified & directed . Note: Three runs of cable will be measured and paid as one run. | 100 | RM | |
31 | 31 | Supply and fix/erect/cable route indicator marked with HT or LT CABLE , made out of GI plate 3 mm thick and 6 inches dia duly marked with working voltage , size of cable and route , fixed with angle iron of size 25 mmX 25 mm X 3 mm thick , 50 CM long embedded in PCC 1:2:4 , type B1 of size 30 CM X 30 CM X 30 CM in ground complete all as specified and as directed. NOTE :- Rate quoted shall be deemed to be inclusive of PCC, excavation and earth work. | 20 | Each | |
32 | 32 | Supply, install , testing and commissioning of outdoor LT distribution feeder pillar IP-65 , CPRI approved of suitable size factory made totally enclosed, dust and vermin proof , double leaf shutter in front and single leaf shutter in rear made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and painted and aluminium bus bar 200 amps, 415 volts, 50 Hz 3 phase and 4 wire system with the following items connected as under including supplying and fixing on MS chanel 75mmx40mmx5mm and fixing the feeder pillar in necessary earthwork and PCC (1:2:4) foundation including PCC (1:2:4) work around the panel board within 60CM from panel all around (Near Sub stn 4):- \nINCOMING (a) MCCB 4 pole 400 Amps, 415 V, 35 KA-01 No \n(b) LCD multifunctioning meter-01 No\n(c) Phase indicator Lamps (RYB phases)-01 Set (Set of Three) LED Cluster type\n(d) CTs 100/5 amps-set of three \n(e) Aluminium bus bar 300 Amps-03 Nos and 150 Amps -01 No\n(f) Internal Wiring for panel including insulators, sleeves etc\nOUTGOING\n(a) MCCB 4 pole 200Amps, 415 V, 25 KA-04 Nos\n | 1 | Each Job | |
33 | 33 | M & L for earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to GI earth strip of 25 mm x 4 mm size by means of bolts, nuts and washers protected by GI tubing light grade 32 mm dia uptoTest point 20 mm dia watering pipe with funnel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates, 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus soil and providing charcoal dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by engr in charge ( NOTE:- Up to 7.5 Mtr length of pipe of 32 mm dia and GI strip shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI strip beyond 7.5 Mtr will be measured separately under respective item). | 5 | Each |