Travancore Devaswom Board-TDB has published Devaswom Board College-Thalayolaparambu Constructing Ladies Hostel Devaswom Board Collegethalayolaparambu-Constructing Ladies Hostel. Submission Date for this Tender is 10-03-2020. Building Work Tenders in Kottayam Kerala. Bidders can get complete Tender details and download the document.
Name of Work:Devaswom Board College Thalayolaparambu- Constructing ladies hostel | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Appendix A Ground Floor | BI01010001010000000000000515BI0100001112 | ||
2 | 1.01 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | BI01010001010000000000000515BI0100001113 | 1120 | m2 |
3 | 1.02 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil | BI01010001010000000000000515BI0100001114 | 1120 | m2 |
4 | 1.03 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. | BI01010001010000000000000515BI0100001115 | 390 | m3 |
5 | 1.04 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | BI01010001010000000000000515BI0100001116 | 45 | m3 |
6 | 1.05 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | BI01010001010000000000000515BI0100001117 | 122 | m3 |
7 | 1.06 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :\n 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size\n | BI01010001010000000000000515BI0100001118 | 95 | m3 |
8 | 1.07 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001119 | 14 | m3 |
9 | 1.08 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001120 | 74 | m3 |
10 | 1.09 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts | BI01010001010000000000000515BI0100001121 | 162 | m2 |
11 | 1.1 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers | BI01010001010000000000000515BI0100001122 | 292 | m2 |
12 | 1.11 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001123 | 400 | m2 |
13 | 1.12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. | BI01010001010000000000000515BI0100001124 | 27450 | kg |
14 | 1.13 | Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete | BI01010001010000000000000515BI0100001125 | 96 | m3 |
15 | 1.14 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete | BI01010001010000000000000515BI0100001126 | 8 | m3 |
16 | 1.15 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood | BI01010001010000000000000515BI0100001127 | 3 | m3 |
17 | 1.16 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood/ jack wood 35 mm thick shutters. | BI01010001010000000000000515BI0100001128 | 50 | m2 |
18 | 1.17 | Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood | BI01010001010000000000000515BI0100001129 | 30 | m2 |
19 | 1.18 | Supplying and providing PVC door with frame | BI01010001010000000000000515BI0100001130 | 20 | m2 |
20 | 1.19 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc. | BI01010001010000000000000515BI0100001131 | 630 | kg |
21 | 1.2 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete | BI01010001010000000000000515BI0100001132 | 80 | kg |
22 | 1.21 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) | BI01010001010000000000000515BI0100001133 | 1856 | m2 |
23 | 1.22 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm | BI01010001010000000000000515BI0100001134 | 326 | m2 |
24 | 1.23 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. | BI01010001010000000000000515BI0100001136 | 25 | m2 |
25 | 1.24 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | BI01010001010000000000000515BI0100001137 | 72 | m2 |
26 | 1.25 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer | BI01010001010000000000000515BI0100001138 | 1856 | m2 |
27 | 1.26 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work | BI01010001010000000000000515BI0100001139 | 1856 | m2 |
28 | 1.27 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre | BI01010001010000000000000515BI0100001140 | 120 | m2 |
29 | 1.28 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work | BI01010001010000000000000515BI0100001141 | 185 | m2 |
30 | 1.29 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid | BI01010001010000000000000515BI0100001142 | 10 | Nos |
31 | 1.3 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 10Kgf/cm2 External work- Exposed on wall | BI01010001010000000000000515BI0100001143 | 75 | m |
32 | 1.31 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall | BI01010001010000000000000515BI0100001144 | 50 | m |
33 | 1.32 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall | BI01010001010000000000000515BI0100001145 | 50 | m |
34 | 1.33 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall | BI01010001010000000000000515BI0100001146 | 50 | m |
35 | 1.34 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore | BI01010001010000000000000515BI0100001147 | 13 | nos |
36 | 1.35 | Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 gms | BI01010001010000000000000515BI0100001148 | 33 | Nos |
37 | 1.36 | Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms | BI01010001010000000000000515BI0100001149 | 2 | Nos |
38 | 1.37 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. | BI01010001010000000000000515BI0100001150 | 10 | Nos |
39 | 2 | Appendix B First Floor | BI01010001010000000000000515BI0100001151 | ||
40 | 2.01 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001152 | 14 | m3 |
41 | 2.02 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001153 | 74 | m3 |
42 | 2.03 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts | BI01010001010000000000000515BI0100001154 | 162 | m2 |
43 | 2.04 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers | BI01010001010000000000000515BI0100001155 | 294 | m2 |
44 | 2.05 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001156 | 400 | m2 |
45 | 2.06 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. | BI01010001010000000000000515BI0100001157 | 13200 | kg |
46 | 2.07 | Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete | BI01010001010000000000000515BI0100001158 | 108 | m3 |
47 | 2.08 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete | BI01010001010000000000000515BI0100001159 | 7 | m3 |
48 | 2.09 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood | BI01010001010000000000000515BI0100001160 | 2.5 | m3 |
49 | 2.1 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood/ jack wood 35 mm thick shutters. | BI01010001010000000000000515BI0100001161 | 46 | m2 |
50 | 2.11 | Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood | BI01010001010000000000000515BI0100001162 | 28 | m2 |
51 | 2.12 | Supplying and providing PVC door with frame | BI01010001010000000000000515BI0100001163 | 15 | m2 |
52 | 2.13 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc. | BI01010001010000000000000515BI0100001164 | 585 | kg |
53 | 2.14 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete | BI01010001010000000000000515BI0100001165 | 180 | kg |
54 | 2.15 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) | BI01010001010000000000000515BI0100001166 | 1776 | m2 |
55 | 2.16 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm | BI01010001010000000000000515BI0100001167 | 320 | m2 |
56 | 2.17 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. | BI01010001010000000000000515BI0100001168 | 25 | m2 |
57 | 2.18 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | BI01010001010000000000000515BI0100001169 | 55 | m2 |
58 | 2.19 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer | BI01010001010000000000000515BI0100001170 | 1725 | m2 |
59 | 2.2 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work | BI01010001010000000000000515BI0100001171 | 1725 | m2 |
60 | 2.21 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre | BI01010001010000000000000515BI0100001172 | 145 | m2 |
61 | 2.22 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work | BI01010001010000000000000515BI0100001173 | 175 | m2 |
62 | 2.23 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid | BI01010001010000000000000515BI0100001174 | 8 | Nos |
63 | 2.24 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 10Kgf/cm2 External work- Exposed on wall | BI01010001010000000000000515BI0100001175 | 75 | m |
64 | 2.25 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall | BI01010001010000000000000515BI0100001176 | 50 | m |
65 | 2.26 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall | BI01010001010000000000000515BI0100001177 | 50 | m |
66 | 2.27 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall | BI01010001010000000000000515BI0100001178 | 50 | m |
67 | 2.28 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore | BI01010001010000000000000515BI0100001179 | 12 | Nos |
68 | 2.29 | Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 gms | BI01010001010000000000000515BI0100001180 | 8 | Nos |
69 | 2.3 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. | BI01010001010000000000000515BI0100001181 | 8 | Nos |
70 | 3 | Appendix C Terrace floor | BI01010001010000000000000515BI0100001182 | ||
71 | 3.01 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001183 | 1 | m3 |
72 | 3.02 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001184 | 6 | m3 |
73 | 3.03 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts | BI01010001010000000000000515BI0100001185 | 15 | m2 |
74 | 3.04 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers | BI01010001010000000000000515BI0100001186 | 15 | m2 |
75 | 3.05 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001187 | 30 | m2 |
76 | 3.06 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. | BI01010001010000000000000515BI0100001188 | 1050 | Kg |
77 | 3.07 | Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete | BI01010001010000000000000515BI0100001189 | 6 | m3 |
78 | 3.08 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete | BI01010001010000000000000515BI0100001190 | 7 | m3 |
79 | 3.09 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood | BI01010001010000000000000515BI0100001191 | 0.07 | m3 |
80 | 3.1 | Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood | BI01010001010000000000000515BI0100001192 | 3 | m2 |
81 | 3.11 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) | BI01010001010000000000000515BI0100001193 | 560 | m2 |
82 | 3.12 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer | BI01010001010000000000000515BI0100001194 | 560 | m2 |
83 | 3.13 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work | BI01010001010000000000000515BI0100001195 | 250 | m2 |
84 | 3.14 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre | BI01010001010000000000000515BI0100001196 | 6 | m2 |
85 | 3.15 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work | BI01010001010000000000000515BI0100001197 | 6 | m2 |
86 | 3.16 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | BI01010001010000000000000515BI0100001198 | 15000 | L |
87 | 4 | Appendix D Roof truss | BI01010001010000000000000515BI0100001199 | ||
88 | 4.01 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001200 | 1592 | kg |
89 | 4.02 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes, having minimum wall thickness of 1.45mm. | BI01010001010000000000000515BI0100001201 | 1795 | kg |
90 | 4.03 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | BI01010001010000000000000515BI0100001202 | 500 | m2 |
91 | 4.04 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 1518 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) | BI01010001010000000000000515BI0100001203 | 60 | m |
92 | 4.05 | Providing and fixing 6" PVC square rain gutter including fixing the gutter with clamps/ clips/ at 1.00 m spacing . This includes jointing of gutter with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge | BI01010001010000000000000515BI0100001204 | 90 | m |
93 | 5 | Appendix E Compound wall | BI01010001010000000000000515BI0100001205 | ||
94 | 5.01 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. | BI01010001010000000000000515BI0100001206 | 40 | m3 |
95 | 5.02 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | BI01010001010000000000000515BI0100001207 | 10 | m3 |
96 | 5.03 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001208 | 32 | m3 |
97 | 5.04 | Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete | BI01010001010000000000000515BI0100001209 | 65 | m3 |
98 | 5.05 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) | BI01010001010000000000000515BI0100001210 | 710 | m2 |
99 | 5.06 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | BI01010001010000000000000515BI0100001211 | 300 | kg |
100 | 5.07 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer | BI01010001010000000000000515BI0100001212 | 710 | m2 |
101 | 5.08 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work | BI01010001010000000000000515BI0100001213 | 710 | m2 |
102 | 5.09 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work | BI01010001010000000000000515BI0100001214 | 55 | m2 |